Installation Guide for SecureMesh ® WAN Extender 2 (XTEN-2000) Document Number:PL-0072A Revision:Preliminary 1.0 Date:September 18, 2020 Trilliant Holdings Inc. 401HarrisonOaks Blvd., Suite300 Cary, NorthCarolina27513 TOC Chapter 1. Safety and compliance6 Safety information6 Compliance notices7 Modification statement8 Interference statement8 FCC Class B digital device notice9 Wireless notice9 WEEE: Waste Electrical and Electronic Equipment Directive9 European Union and European Free Trade Association (EU & EFTA) compliance notices10 Chapter 2. Overview11 Ethernet cable11 Kits and accessories12 Supplies13 Spare/replacement parts13 Chapter 3. Prepare for installation14 Tools14 Location requirements14 Grounding requirements15 Grounding guidelines 15 Grounding checklist17 Extender components18 Preparing the extender19 Optional steps for using a short mounting pipe22 Preparing the Device Side Cable (DSC)22 Steps to Prepare the DSC23 Preparing the surge suppressor26 Ethernet surge suppressor (CMJ8-PoE-A-C5E)26 Setting the configuration37 Extender parameters38 Chapter 4. Mount the extender39 Attach the extender to a pole or tower39 Chapter 5. Commission the extender43 LED indicators43 Startup in cold conditions44 Accessing the CLI using WiFi47 Steps48 Chapter 6. Specifications53 Pinouts53 Proprietary Notice Copyright © Trilliant Holdings Inc. 2020. All rights reserved. This document describes products, software and services (“Products”) of Trilliant Holdings Inc., its subsidiaries, affiliates (collectively, "Trilliant"), and/or its licensors. This document is licensed, not sold. Except as set out in the License or other written agreement between Trilliant and your company: (1) the purchase or use of a Product from Trilliant does not convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of Trilliant or third parties; (2) Trilliant does not assume any responsibility or liability arising out of the use of this document or any Product it describes; and (3) no part of the document may be disclosed in any form to any third party. Trilliant reserves the right to make changes to this document or to any Products it describes at any time with or without notice. Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227- 14 (g) (2) (6/87) and FAR 52.227-19 (6/87), or DFAR 252.227-7015 (b) (6/95) and DFAR 227.7202-3 (a). Trilliant ® , SecureMesh ® , UnitySuite ® , and Trilliant SecureReach ® are registered trademarks of Trilliant. Any third-party name or mark in this document may be a trademark of its owners. Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. InstallationGuideforSecureMesh ® WAN Extender2-PL-0073A How to Contact Trilliant Use the following methods to contact Trilliant: General Company and Solution Information:https://trilliant.com/ Trilliant Headquarters: Tel:+1 919.495.6111 Solution and Customer Support Portal:https://trilliant.com/support/ Note: Make all requests for Solution support or RMA processing through the web portal. If you do not have a Support Portal login and password, or need your credentials reset, contact Trilliant Support using the email address below. E-mail:[email protected] Use this email address primarily for requesting access to the Support Portal, or for resetting access credentials. This email address is not a primary means of communicating with Customer Support. Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. InstallationGuideforSecureMesh ® WAN Extender2-PL-0073A Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. 6 InstallationGuideforSecureMesh ® WAN Extender2-PL-0072A Chapter 1. Safety and compliance This chapter provides safety and compliance information for installers. Before installing the SecureMesh ® Extender-2000 (XTEN-2000), read the instructions in this document. Safetyinformation The caution statements, warning conventions, and warning messages in this section apply to this product and manual. Trilliant strongly urges that you always follow all locally-approved safety procedures and safety instructions when working around high voltage lines and equipment. The instructions in this manual are not intended as a substitute for proper training in or adequate experience with safely operating the described equipment. Only competent technicians who are familiar with this equipment should install or service it. A competent technician: lIs thoroughly familiar with these instructions lIs trained in industry-accepted high- and low-voltage safe operating practices and procedures lIs trained and authorized to energize, de-energize, clear, and ground power distribution equipment lIs trained in the care and use of protective equipment such as flash clothing, safety glasses, face shields, hardhats, rubber gloves, hot sticks, etc. The following are important safety instructions. To safely install and operate this equipment, be sure to read, understand, and follow all caution and warning notices and instructions marked on the product or…
Text truncated - open the document above for the full version.
Installation Guide for SecureMesh ® WAN Gateway 2 (GATE-2000) Document Number:PL-0073A Revision:Preliminary 1.0 Date:September 18, 2020 Trilliant Holdings Inc. 401HarrisonOaks Blvd., Suite300 Cary, NorthCarolina27513 TOC Chapter 1. Safety and compliance6 Safety information6 Compliance notices7 Modification statement8 Interference statement8 FCC Class B digital device notice9 Wireless notice9 WEEE: Waste Electrical and Electronic Equipment Directive9 European Union and European Free Trade Association (EU & EFTA) compliance notices10 Chapter 2. Overview11 Ethernet cable11 Kits and accessories12 Supplies13 Spare/replacement parts13 Chapter 3. Prepare for installation14 Tools14 Location requirements14 Grounding requirements15 Grounding guidelines 15 Grounding checklist17 Gateway components18 Preparing the gateway19 Optional steps for using a short mounting pipe22 Preparing the Device Side Cable (DSC)22 Steps to Prepare the DSC23 Preparing the surge suppressor26 Ethernet surge suppressor (CMJ8-PoE-A-C5E)26 Setting the configuration37 Gateway parameters38 Chapter 4. Mount the gateway39 Attach the gateway to a pole or tower39 Chapter 5. Commission the gateway43 LED indicators43 Startup in cold conditions44 Accessing the CLI using WiFi47 Steps48 Chapter 6. Specifications53 Pinouts53 Proprietary Notice Copyright © Trilliant Holdings Inc. 2020. All rights reserved. This document describes products, software and services (“Products”) of Trilliant Holdings Inc., its subsidiaries, affiliates (collectively, "Trilliant"), and/or its licensors. This document is licensed, not sold. Except as set out in the License or other written agreement between Trilliant and your company: (1) the purchase or use of a Product from Trilliant does not convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of Trilliant or third parties; (2) Trilliant does not assume any responsibility or liability arising out of the use of this document or any Product it describes; and (3) no part of the document may be disclosed in any form to any third party. Trilliant reserves the right to make changes to this document or to any Products it describes at any time with or without notice. Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227- 14 (g) (2) (6/87) and FAR 52.227-19 (6/87), or DFAR 252.227-7015 (b) (6/95) and DFAR 227.7202-3 (a). Trilliant ® , SecureMesh ® , UnitySuite ® , and Trilliant SecureReach ® are registered trademarks of Trilliant. Any third-party name or mark in this document may be a trademark of its owners. Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. InstallationGuideforSecureMesh ® WAN Gateway 2-PL-0073A How to Contact Trilliant Use the following methods to contact Trilliant: General Company and Solution Information:https://trilliant.com/ Trilliant Headquarters: Tel:+1 919.495.6111 Solution and Customer Support Portal:https://trilliant.com/support/ Note: Make all requests for Solution support or RMA processing through the web portal. If you do not have a Support Portal login and password, or need your credentials reset, contact Trilliant Support using the email address below. E-mail:[email protected] Use this email address primarily for requesting access to the Support Portal, or for resetting access credentials. This email address is not a primary means of communicating with Customer Support. Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. InstallationGuideforSecureMesh ® WAN Gateway 2-PL-0073A Notice: Thecontents of this document areproprietary andconfidentialandtheproperty of Trilliant Holdings Inc., its subsidiaries, affiliates, and/or licensors. This document is providedsubject totheconfidentiality obligations set forthintheagreement betweenyourcompany andTrilliant. Thecontents may not beusedordisclosedwithout theexpress writtenconsent of Trilliant. 6 InstallationGuideforSecureMeshWAN ® Gateway 2-PL-0073A Chapter 1. Safety and compliance This chapter provides safety and compliance information for installers. Before installing the SecureMesh ® Gateway-2000 (GATE-2000), read the instructions in this document. Safetyinformation The caution statements, warning conventions, and warning messages in this section apply to this product and manual. Trilliant strongly urges that you always follow all locally-approved safety procedures and safety instructions when working around high voltage lines and equipment. The instructions in this manual are not intended as a substitute for proper training in or adequate experience with safely operating the described equipment. Only competent technicians who are familiar with this equipment should install or service it. A competent technician: lIs thoroughly familiar with these instructions lIs trained in industry-accepted high- and low-voltage safe operating practices and procedures lIs trained and authorized to energize, de-energize, clear, and ground power distribution equipment lIs trained in the care and use of protective equipment such as flash clothing, safety glasses, face shields, hardhats, rubber gloves, hot sticks, etc. The following are important safety instructions. To safely install and operate this equipment, be sure to read, understand, and follow all caution and warning notices and instructions marked on the product or included…
Text truncated - open the document above for the full version.
401 Harrison Oaks Boulevard, Suite 300 • Cary, NC 27513 • 919.495.6111 www.trilliant.com 9/22/2020 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC ID: TMB-WAN2000 Model: SecureMesh WAN Series 2 Request for Permanent Confidentiality Pursuant to Sections 0.457(d) and 0.459 of the Commission’s rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Bill of Materials • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated: 9/22/2020 Signed: Printed name: Daniel Tousignant Title: Certification & Compliance Eng. On behalf of: Trilliant Networks Inc.
401 Harrison Oaks Boulevard, Suite 300 • Cary, NC 27513 • 919.495.6111 www.trilliant.com September 22, 2020 FCC ID: TMB-WAN2000 Product Name: SecureMesh WAN Series 2 Applicant: Trilliant Networks Inc. Model Differences Dear Examiner, This is to explain the differences between the two models of the SecureMesh WAN Series 2: the gateway GATE-2000 and the extender XTEN-2 000. Except for the labels, both models are identical in hardware. Most of the firmware is also identical including all RF functions. The differences are in the network’s behavior as the GATE-2000 is the root node interface between the wireless SecureMesh WAN Network and the customer wired backhaul. The GATE-2 000 is also the master of the SecureMesh WAN Network defining the network’s parameters. The XTEN-2000 is a relay node to extend the range of the wireless SecureMesh WAN network. It can also, along with other devices not part of this certification, act as the end node of the this network by providing an Ethernet connectivity for WAN client devices in direct support of Internet of Things (IoT) monitoring, video surveillance, or work-force management applications. Sincerely, Daniel Tousignant, ing. Certification & Compliance Eng.
401 Harrison Oaks Boulevard, Suite 300 • Cary, NC 27513 • 919.495.6111 www.trilliant.com Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent FCC On our behalf, I appoint Jenny Gibbs of Nemko USA, Inc. 2650 FM 407, Suite 255P, Bartonville, TX 76226, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti- Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides to Trilliant Networks Inc. 401 Harrison Oaks Boulevard, Suite 300, Cary, NC 27513. Date: September 22, 2020 Agency agreement expiration date: September 22, 2021 By: Daniel Tousignant Certification & Compliance Eng. On behalf of: Trilliant Networks Inc. Telephone: (450) 915-1631
WAN-2000 External photos Page 1 of 3 This device is round thus, front, back and sides are all identical WAN-2000 External photos Page 2 of 3 Bottom WAN-2000 External photos Page 3 of 3 Top
WAN-2000 Labels & Placement Page 1 of 3 GATE-2000 Label XTEN-2000 Label WAN-2000 Labels & Placement Page 2 of 3 GATE-2000 Label Placement WAN-2000 Labels & Placement Page 3 of 3 XTEN-2000 Label Placement
WAN-2000 Internal photos Page 1 of 15 Cover removed WAN-2000 Internal photos Page 2 of 15 Some antennas removed WAN-2000 Internal photos Page 3 of 15 Base with top section removed showing LED/WIFI board (top) and Ethernet I/O board (bottom) WAN-2000 Internal photos Page 4 of 15 Antenna top and bottom WAN-2000 Internal photos Page 5 of 15 UCC board Top WAN-2000 Internal photos Page 6 of 15 UCC board top without Mikrotik radio WAN-2000 Internal photos Page 7 of 15 UCC board bottom WAN-2000 Internal photos Page 8 of 15 MikroTik radio Top and Bottom WAN-2000 Internal photos Page 9 of 15 MikroTik radio Top without heat sink MikroTik radio bottom without shield WAN-2000 Internal photos Page 10 of 15 Switchboard Top WAN-2000 Internal photos Page 11 of 15 Switchboard Bottom WAN-2000 Internal photos Page 12 of 15 LED/WIFI board Top LED/WIFI board Bottom WAN-2000 Internal photos Page 13 of 15 WIFI Module ESP-WROOM-02 Top and Bottom WIFI Module ESP-WROOM-02 without shield WAN-2000 Internal photos Page 14 of 15 Ethernet I/O board Top Ethernet I/O baord Bottom WAN-2000 Internal photos Page 15 of 15 Ethernet Protection Module board Top Ethernet Protection Module board Bottom
Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna 5G Tx :TMB-WAN2000 Fundamental transmit (prediction) frequency:5735MHz Maximum measured conducted peak output power:29.30dBm Cable and/or jumper loss:0.0dB Maximum peak power at antenna input terminal:29.30dBm Tx On time:1.000ms Tx period time:1.000ms Average factor:100% Maximum calculated average power at antenna input terminal:851.138mW Single Antenna gain (typical):16.5dBi Number of antennae:1 Total system gain (typical):16.500dBi MPE limit for uncontrolled exposure at prediction frequency:1mW/cm 2 10W/m 2 Minimum calculated prediction distance for compliance:55cm Typical (declared) distance:60cm Average power density at prediction frequency:0.840403 mW/cm 2 8.40403 W/m 2 Margin of Compliance:0.75512dB Maximum allowable antenna gain:17.25512dBi % to limit:84.04030797% 2 4R PG S Choose Scandinavian trust
www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation FCC 15.407, RSS-247 UNII-3; Date: August 2020 SCC Accredited LAB LAB Accrédité CCN TM Choose Scandinavian trust RADIO TEST REPORT – 389104-1TRFWL Type of assessment: Final product testing Applicant: Product: Trilliant Networks Inc. WAN-2000 Model: Model variant(s): SecureMesh WAN Series 2 GATE-2000 XTEN-2000 FCC ID: TMB-WAN2000 Specifications: FCC 47 CFR Part 15 Subpart E, §15.407 RSS-247, Issue 2, Feb 2017, Section 6 Date of issue: October 7, 2020 Yong Huang, Wireless/EMC Specialist Tested by Signature Mark Libbrecht, EMC/RF Specialist Reviewed by Signature Report reference ID: 389104-1TRFWL Page 2 of 59 Lab locations Company name Nemko Canada Inc. Facilities Ottawa site: 303 River Road Ottawa, Ontario Canada K1V 1H2 Tel: +1 613 737 9680 Fax: +1 613 737 9691 Montréal site: 292 Labrosse Avenue Pointe-Claire, Québec Canada H9R 5L8 Tel: +1 514 694 2684 Fax: +1 514 694 3528 Cambridge site: 1-130 Saltsman Drive Cambridge, Ontario Canada N3E 0B2 Tel: +1 519 650 4811 Almonte site: 1500 Peter Robinson Road West Carleton, Ontario Canada K0A 1L0 Tel: +1 613 256-9117 Test site identifier Organization Ottawa/Almonte Montreal Cambridge FCC: CA2040 CA2041 CA0101 ISED: 2040A-4 2040G-5 24676 Website www.nemko.com Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada’s ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: 389104-1TRFWL Page 3 of 59 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Measurement uncertainty .................................................................................................................................................................. 7 4.1 Uncertainty of measurement ................................................................................................................................................................................... 7 Information provided by the applicant ................................................................................................................................................ 8 5.1 Disclaimer ........................................…
Text truncated - open the document above for the full version.
www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation setup photos.docx; Date: May 2013 ONE WORLDOURAPPROVAL Setup photos 389104-1RADWL Date of issue: October 16, 2020 Applicant: Trilliant Networks Inc. Product: WAN-2000 Model: Model variant(s): SecureMesh WAN Series 2 GATE-2000 XTEN-2000 FCC ID: TMB-WAN2000 Section 1: setup photos Report reference ID: -389104-1RADWL Page 2 of 5 Section 1. Setup photos 1.1 Radiated Front view Section 1: setup photos Report reference ID: -389104-1RADWL Page 3 of 5 1.2 Radiated back view Section 1: setup photos Report reference ID: -389104-1RADWL Page 4 of 5 1.3 Power line conducted test view Section 1: setup photos Report reference ID: -389104-1RADWL Page 5 of 5 1.4 Antenna conducted test view
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 455.00 mW |

NETWORK ACCESS POINT
Equipment Class
DTS - Digital Transmission System
Transceiver Module
Equipment Class
DTS - Digital Transmission System
Utility Meter
Equipment Class
DTS - Digital Transmission System
Wireless Electric Meter
Equipment Class
DTS - Digital Transmission System
802.15.4 Transceiver Module
Equipment Class
DTS - Digital Transmission System