FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Continental Conair Limited/
  3. U43WIH400

U43WIH400Commercial Induction Range

Continental Conair Limited
Commercial Induction Range - FCC ID U43WIH400 - Continental Conair Limited
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Dec 26, 2012
Application Purpose
Original Equipment
Date of Application
Dec 26, 2012
Equipment Note
Commercial Induction Range
Frequency Range
0.01800000 - 0.06500000
Company
Continental Conair Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

COMMERCIAL INDUCTION RANGE PLACA DE INDUCCIÓN COMERCIAL PLAQUE À INDUCTION COMMERCIALE WIH400, WIH400C For your safety and continued enjoyment of this product, always read the instruction book carefully before using. Para su seguridad y para disfrutar plenamente de este producto, siempre lea las instrucciones cuidadosamente antes de usarlo. A!n que cet appareil vous procure en toute sécurité beaucoup de satisfaction, lire attentivement le mode d’emploi avant de l’utiliser. 2 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. READ ALL INSTRUCTIONS. 2. Unplug from outlet when not in use, before putting on or taking off parts and before cleaning. 3. To protect against risk of electric shock, do not put appliance in water or other liquids. 4. Do not touch surfaces that may be hot. 5. Avoid contact with moving parts. 6. Do not operate the Waring ™ Commercial Induction Range or any other electrical equipment with a damaged cord or plug, or after the unit malfunctions or is dropped or damaged in any manner. Return it to the nearest Waring Authorized Service Center for examination, repair, and/or adjustment. 7. The use of attachments not recommended or sold by Waring may cause !re, electric shock, or injury. 8. Do not use outdoors. 9. Do not let cord hang over edge of table or counter, or touch hot surfaces. 10. The Waring ™ Commercial Induction Range should always be on a stable countertop or table. 11. Do not use appliance for other than intended use. 12. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 13. Children should be supervised to ensure that they do not play with the appliance. 14. Do no cook on broken cooktop – If the glass cooktop should break, cleaning solutions and spillovers may penetrate the broken surface and create a risk of electrical shock. 3 15. Clean cooktop with caution – If a wet sponge or cloth is used to wipe spills on a hot cooking area, be careful to avoid steam burn; some cleaners can produce noxious fumes if applied to a hot surface. 16. Do not place metal objects such as knives, forks, spoons and lids on the glass surface since they can get hot. SAVE THESE INSTRUCTIONS APPROVED FOR COMMERCIAL USE GROUNDING INSTRUCTIONS: r'PSZPVSQSPUFDUJPO UIF8BSJOH ™ Commercial Induction Range is equipped with a 3-conductor cord set. rWPMUVOJUTBSFTVQQMJFEXJUIBNPMEFEQSPOHHSPVOEJOH type plug and should be used in combination with a properly connected grounding-type outlet, as shown in Figure 1. If a grounding-type outlet is not available, an adapter, shown in Figure 2, may be obtained to enable a 2-slot wall outlet to be used with a 3-prong plug. As shown in Figure 3, the adapter must be grounded by attaching its grounding lug under the screw of the outlet cover plate. CAUTION: Before using an adapter, it must be determined that the outlet cover plate screw is properly grounded. If in doubt, consult a licensed electrician. Never use an adapter unless you are sure it is properly grounded. NOTE: Use of an adapter is not permitted in Canada. 4 SPECIAL CORD SET INSTRUCTIONS A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord. Extension cords may be used if care is exercised in their use. If an extension cord is used, the marked electrical rating of the extension cord must be at least as great as the electrical rating of the appliance. If the appliance is of the grounded type, the extension cord should be a grounding-type 3-wire cord, and the longer cord should be arranged so that it will not drape over the counter top or table top where it can be pulled by children or tripped over. SPECIFICATIONS MODELELECTRICALPLUG TYPEDIMENSIONS (inches)LISTING WIH400 120V, 15 AMP 1800 W NEMA 5-15 P16.5" (D) x 4" (H) ETLus NSF WIH400C 120V, 12 AMP 1440 W NEMA 5-15 P16.5” (D) x 4” (H) cETLus NSF NOTE: Your Waring ™ Commercial Induction Range defaults to Fahrenheit setting. Every time the unit is plugged in it will default to Fahrenheit. To change to Celsius follow directions on page 5. * Schott is a trademark of the Schott Corporation. PARTS 1. Heat Mode Setting 2. Temperature Mode Setting 3. Timer Mode Setting 4. LCD Display 5. Adjustment Control for Temper atu re/Heat / Timer 6. On/Off Power Button 7. Stainless Steel Housing 8. Schott ® * Ceramic Glass Cooking Surface 1. 2. 3. 4. 5. 7. 8. 6. 5 OPERATION NOTE: The Induction Range requires induction-ready cookware. If the pan is not induction ready, it will not register on the induction range. The LCD display will show “-----” and “STANDBY” will "ash (as seen in !gure 1) when attempting to select a heat mode without an induction-ready pan on the glass cooking surface. The unit will automatically shut off after 60 seconds of not having an induction-ready pot/pan. 1. Before turning on the power, make sure the cookware is on the ceramic cooking surface. Your Waring ™ Commercial Induction Range is equipped with small-object detection which will prevent it from operating unless you have an appropriate sized induction-ready pan in place. 2. To turn the power on, press the ON/OFF button and choose a cooking mode by pressing HEAT or TEMP button. NOTE: The unit will automatically shut off after 30 seconds if you do not choose a cooking mode. a) The HEAT button allows you to choose how many watts of power to cook with. b) The TEMP button allows you to choose the temperature at which you cook. 3. Once you’ve chosen a cooking mode, use the + and – buttons to set the desired wattage or temperature. EMPTY-PAN DETECTION After extended periods of time with an empty pan, your Waring ™ Commercial Induction Range will automatically shut off. CHOOSING F…

Text truncated - open the document above for the full version.

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPH EUT – Top View EUT - Bottom View EUT - Front View EUT - Rear View EUT – Left Side View EUT – Right Side View

ID Label/Location Info

EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Specifications : Text is Black or white in color and is left justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Label Here

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View EUT – Main Board Top View 1 EUT – Main Board Top View 2 EUT – Main Board Bottom View EUT – Keyboard Top View EUT – Keyboard Bottom View EUT – Excitation Coil Top View EUT – Excitation Coil Bottom View EUT – Electric Fan Top View EUT – Electric Fan Bottom View

Test Report

Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” FCC PART 18 TEST REPORT For Continental Conair Limited 35/F, Standard Chartered Tower, Millennium City 1, 388 Kwun Tong Road, Kwun Tong, Kowloon, Hong Kong. FCC ID: U43WIH400 Report Type: Original Report Product Name: Commercial Induction Range Test Engineer: Andrew Shu Report Number: RSZ121127550-00 Report Date: 2012-12-04 Reviewed By: Dick Zhang EMC Leader Test Laboratory: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ121127550-00 FCC Part 18 Page 2 of 16 TABLE OF CONTENTS GENERAL INFORMATION ...................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3 OBJECTIVE................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................ 3 TEST METHODOLOGY.................................................................................................................................................. 3 TEST FACILITY............................................................................................................................................................ 3 SYSTEM TEST CONFIGURATION ......................................................................................................................... 5 JUSTIFICATION............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE.......................................................................................................................................... 5 SPECIAL ACCESSORIES................................................................................................................................................ 5 EQUIPMENT MODIFICATIONS....................................................................................................................................... 5 EXTERNAL CABLE....................................................................................................................................................... 5 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................6 SUMMARY OF TEST RESULT................................................................................................................................. 7 FCC §18.307 - AC LINE CONDUCTED EMISSIONS ............................................................................................. 8 APPLICABLE STANDARD.............................................................................................................................................. 8 EUT SETUP................................................................................................................................................................. 8 EMI TEST RECEIVER SETUP........................................................................................................................................ 9 TEST PROCEDURE........................................................................................................................................................ 9 TEST EQUIPMENT LIST AND DETAILS.......................................................................................................................... 9 TEST RESULTS SUMMARY......................................................................................................................................... 10 TEST DATA................................................................................................................................................................ 10 FCC §18.305 – FIELD STRENGTH ......................................................................................................................... 13 APPLICABLE STANDARD............................................................................................................................................ 13 EUT SETUP............................................................................................................................................................... 13 EMI TEST RECEIVER SETUP AND SPECTRUM ANALYZER SETUP............................................................................... 13 TEST PROCEDURE...................................................................................................................................................... 14 CORRECTED AMPLITUDE CALCULATION................................................................................................................... 14 TEST EQUIPMENT LIST AND DETAILS........................................................................................................................ 14 TEST DATA..............................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS AC Line Conducted Emissions – Front View AC Line Conducted Emissions – Side View Field Strength – Front View Field Strength – Rear View

Contact Information

Applicant

Wesley Chiu(Engineering Director)
[email protected]852-27514688Fax: 852-27518920

Test Firm

Bay Area Compliance Laboratory Corp. (Shenzhen)John Chan
[email protected]08675533320018Fax: 08675533320008

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.018 MHz - 0.065 MHz-

Other Applications from Continental Conair Limited

Commercial Induction Range - FCC ID U43WIH400B - Continental Conair Limited
U43WIH400B

Commercial Induction Range

Sep 16, 2014

Equipment Class

8CC - Part 18 Consumer Device
Commercial Induction Range - FCC ID U43WIH400CND - Continental Conair Limited
U43WIH400CND

Commercial Induction Range

Jan 10, 2013

Equipment Class

8CC - Part 18 Consumer Device
Double Induction Cooktop - FCC ID U43ICT400 - Continental Conair Limited
U43ICT400

Double Induction Cooktop

Jul 27, 2012

Equipment Class

8CC - Part 18 Consumer Device
Induction Cooker - FCC ID U43ICT100 - Continental Conair Limited
U43ICT100

Induction Cooker

Mar 20, 2007

Equipment Class

8CC - Part 18 Consumer Device