Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ACRIVA 9 ACRIVA 7 Nano BTE Nano RITE Behind-the-ear hearing instruments INSTRUCTIONS FOR USE 2 3 TABLE OF CONTENTS General Warnings and Safety Guidelines 7 Introduction 13 Acriva Nano BTE with Spira Flex Thin Tube System 14 Acriva Nano BTE with Earhook 15 Ear Piece Overview for Nano BTE 16 Acriva Nano RITE with Speaker Unit 17 Ear Piece Overview for Nano RITE 18 Placement 20 Operating Your Instruments 26 Changing the Volume Level 27 Changing Programs 29 Muting 30 Telecoil Function (for Nano RITE only) 31 Telephone Use (for Nano RITE only) 32 Changing the Battery 34 Data Logging and Learning 36 Operating the Hearing Instruments with the Optional RC-P Remote Control 37 4 5 Operating the Hearing Instruments with the Optional SoundGate Communication Device 38 Instrument Care 40 Using Your Hearing Instruments 58 Tips for Communicating with Hearing Impaired People 62 Your Hearing Instrument Configuration 64 Accessories 67 Environmental Protection 68 Product Approval, Markings and Compliance 69 Cell Phone and Hearing Instrument Compatibility 71 International Warranty 73 Common Problems and Solutions 74 Information for the Hearing Care Professional 80 Compliance with Requirements for Europe 82 Compliance with Radio Communications Requirements for the USA and Canada 84 Information and Explanation of Symbols 86 Service 90 6 Congratulations on the purchase of your new Bernafon hearing instruments. The amplification of sound provided by your hearing instruments was adjusted by your hearing care professional to the needs of your individual hearing loss. With a little practice, you will soon be on your way to better hearing. Please read the entire contents of this booklet before using your hearing instruments. It contains instructions and important information about the use and handling of your hearing instruments and batteries. 7 General Warnings and Safety Guidelines Hearing instruments and batteries can be dangerous if swallowed or improperly used. Such actions can result in severe injury, permanent hearing loss or even fatality. Familiarize yourself completely with the following general warnings before using your hearing instru- ments. Hazard Warnings Never allow others to wear your hearing instruments, because they are adjusted for your hearing requirements and may permanently damage another person’s hearing. A slap to your ear while wearing the instrument could be harmful. Avoid wear- ing your hearing instrument while playing contact sports (e.g. rugby, football, etc.). 8 Hearing instruments, their parts and batteries should be kept out of reach of infants, children and anyone who might swallow these items or otherwise cause themselves injury. Discard batteries and keep them out of sight of infants, small children, persons of mental incapacity or pets. Clean your hearing instruments and their parts on a regular basis as recommended. Micro-organ isms from unclean instruments may cause skin irritations. Be careful with leaking battery liquid, as it is a hazardous substance. Never try to recharge non-rechargeable batteries. Never change the battery or adjust the controls of the hearing instrument in front of infants, small children and persons of mental incapacity. 9 Be aware of the possibility that your instruments may stop functioning without notice. Keep this in mind while you circulate in traffic or otherwise depend on warning sounds. Traffic or other warning sounds may also be reduced in level by a directional microphone when these sounds are coming from behind you. Remove your instruments before applying aftershave, hairspray, oils, perfume, mosquito repellent, lotions, etc. Allow the product to dry before wearing your instruments. 10 Warning to Hearing Care Professional and User Special care should be taken when fitting and using a hearing instrument with maximum sound pressure capability in excess of a maximum of 132 dB SPL (IEC 60318-4) since there may be a risk of impairing the remaining hearing of the hearing instrument user. 11 Safety Information ·Hearing instruments should be used only as directed and adjusted by your trained hearing care professional. Misuse or improper adjust- ments can result in sudden and permanent hearing loss. ·Hearing instruments will not restore normal hearing or prevent hearing loss resulting from organic conditions. ·Never put your hearing instrument or batteries in your mouth, they could easily be swallowed. ·Keep batteries away from medications. Batteries are easily mistaken for pills. ·In case a battery or hearing instrument is swallowed, see a doctor immediately. ·Be aware that use of a hearing instrument may cause excess ear wax to build up in the ear canal which may require removal by a trained medical professional. ·In rare cases, a hearing instrument or earmold may cause a discharge from the ear or allergic reaction. See a physician immediately if these conditions occur. ·An earmold is a custom-made product. If you experience discomfort or irritation of your ear, please see your hearing care professional immediately for modification of the earmold. 12 ·Never insert cleaning tools into the sound outlet or microphone inlet. This could damage the hearing instruments. ·Do not expose hearing instruments to extreme heat by leaving them in the car, near a radiator, etc. ·Do not wear your hearing instrument while swim- ming, snorkeling or diving, as it is not designed for such activities. ·Do not immerse your hearing instrument in water or other liquids. ·It is recommended to remove your hearing instruments before sleeping. ·Protect your instruments by keeping them in the case when you are not wearing them. 13 The following instruments are covered in these instructions: Acriva Nano BTE Acriva Nano RITE AR9 N AR9 NR AR7 N AR7 NR Introduction Acriva Nano BTE instruments are available either with earhooks or Spira Flex thin tubes. CN_ILLU_NR_InstrumentwithSpeaker_BW_HI Acriva Nano RITE instruments are available either with M- or P-Speaker. Bernafon nano BTE IFU …
Text truncated - open the document above for the full version.
Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 24 of 32 Annex B External photographs of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 25 of 32 Photo 3: Photo 4: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 26 of 32 Photo 5:
A4 RevisionCategory 6 X Y unless otherwise specified. All dimensions in millimetres. it nor copied or otherwise made use of by such person without our author ity This drawing must not be passed on t o any person not authorized by us to receive Scale Sheet description Sheet No. shts.of Drawing No Designation 888 83 013 ABCD 1 2 3 4 5 5:1 - Initials Shell basis assy, RITE marked 1 1 Originated by: brn_ai Revised by: brn_msp DOC-00011398A1 Marking origin Manufacturer and model name Tampon printed according to K-specification. A4 RevisionCategory 6 (7.19) 1.35 0.20 1.15 0.05 5.300.30 unless otherwise specified. All dimensions in millimetres. it nor copied or otherwise made use of by such person without our author ity This drawing must not be passed on t o any person not authorized by us to receive Scale Sheet description Sheet No. shts.of Drawing No Designation 888 83 013 ABCD 1 2 3 4 5 10:1 InitialsDate Cliché "Bernafon AR9 NR" 1 1 Originated by: MZU 13-07-2012 Revised by: Ver. 4 DOC-00021629K0 Marking origin Marking according to .dxf file Model name font: Arial or equivalent A4 RevisionCategory 6 (7.19) 1.35 0.20 1.15 0.05 5.300.30 unless otherwise specified. All dimensions in millimetres. it nor copied or otherwise made use of by such person without our author ity This drawing must not be passed on t o any person not authorized by us to receive Scale Sheet description Sheet No. shts.of Drawing No Designation 888 83 013 ABCD 1 2 3 4 5 10:1 InitialsDate Cliché "Bernafon AR7 NR" 1 1 Originated by: MZU 13-07-2012 Revised by: Ver. 3 DOC-00021630K0 Marking origin Marking according to .dxf file Model name font: Arial or equivalent A4 RevisionCategory 6 5.300.30 0.80 0.10 1.35 0.20 X Y unless otherwise specified. All dimensions in millimetres. it nor copied or otherwise made use of by such person without our author ity This drawing must not be passed on t o any person not authorized by us to receive Scale Sheet description Sheet No. shts.of Drawing No Designation 888 83 013 ABCD 1 2 3 4 5 10:1 InitialsDate Cliché "PC9 NR" 1 1 Originated by: MSP 30-08-2012 Revised by: Ver. 1 DOC-00022507K0 Marking origin Font and Logo according to electronical .eps file A4 RevisionCategory 6 5.300.30 0.80 0.10 1.35 0.20 X Y unless otherwise specified. All dimensions in millimetres. it nor copied or otherwise made use of by such person without our author ity This drawing must not be passed on t o any person not authorized by us to receive Scale Sheet description Sheet No. shts.of Drawing No Designation 888 83 013 ABCD 1 2 3 4 5 10:1 InitialsDate Cliché "PC7 NR" 1 1 Originated by: MSP 30-08-2012 Revised by: Ver. 1 DOC-00022508K0 Marking origin Font and Logo according to electronical .eps file
Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 27 of 32 Annex C Internal photographs of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 28 of 32 Photo 3: Photo 4: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 29 of 32 Photo 5: Photo 6: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 30 of 32 Photo 7:
2012-12-20 Page 1 of 32 TEST REPORT Test report no.: 1-5178/12-01-06-C Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio/Satellite Communications Bernafon AG Morgenstraße 131 3018 Bern / SWITZERLAND Phone: +41 31 9 98 15 15 Contact: Thomas Leuzinger e-mail: [email protected] Phone: +41 31 998 16 92 Manufacturer Bernafon AG Morgenstraße 131 3018 Bern / SWITZERLAND Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I Part 15 - Radio frequency devices RSS - 210 Issue 8 Spectrum Management and Telecommunications - Radio Standards Specification Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Air Conduction Hearing Aid with Wireless Functionality Model name: AR9 NR, PC9 NR, AR7 NR, PC7 NR FCC ID: U6XF2RITE2 IC: 7031A-F2RITE2 Frequency: 3.84 MHz Technology tested: Magnetic coupling Antenna: Integrated coil antenna Power Supply: 1.4 V DC by Zinc Air Cell (312) Temperature Range: 0°C to +40 °C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: p.o. Stefan Bös Andreas Luckenbill Senior Testing Manager Expert Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 2 of 32 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 2.1 Notes and disclaimer .......................................................................................................................... 3 2.2 Application details ............................................................................................................................... 3 3 Test standard/s ............................................................................................................................................... 3 4 Test environment ............................................................................................................................................ 4 5 Test item .......................................................................................................................................................... 4 6 Test laboratories sub-contracted ................................................................................................................. 4 7 Summary of measurement results ............................................................................................................... 5 8 RF measurements .......................................................................................................................................... 6 8.1 Description of test setup .................................................................................................................... 6 8.1.1 Radiated measurements............................................................................................................. 6 8.1.2 Conducted measurements.......................................................................................................... 7 8.2 Additional comments .......................................................................................................................... 7 8.3 RSP100 test report cover sheet / performance test data ................................................................ 8 9 Measurement results ...................................................................................................................................... 9 9.1 Timing of the transmitter .................................................................................................................... 9 9.2 Bandwidth of the modulated carrier .................................................................................................. 9 9.3 Field strength of the fundamental ................................................................................................... 10 9.4 Field strength of the harmonics and spurious ............................................................................... 11 9.5 Receiver spurious emissions ........................................................................................................... 15 9.6 Conducted limits ............................................................................................................................... 18 10 Test equipment and ancillaries used for tests ................................................................................... 19 11 Observations ......................................................................................................................................... 19 Annex A Photographs of the test setup ...................................................................................................... 20 Annex B External photographs of the EUT ................................................................................................. 24 Annex C Internal photographs of the EUT .................................................................................................…
Text truncated - open the document above for the full version.
Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 20 of 32 Annex A Photographs of the test setup Photo documentation: Photo 1: Photo 2: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 21 of 32 Photo 3: Photo 4: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 22 of 32 Photo 5: Photo 6: Test report no.: 1-5178/12-01-06-C 2012-12-20 Page 23 of 32 Photo 7:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 3.84 MHz - 3.84 MHz | - |

Hearing Aid
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Audio Streaming Device
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Hearing Aid (in the ear)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Hearing Aid (behind the ear)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Hearing Instrument
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter