FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GS Instech Co., Ltd./
  3. U88-GRS-1924R-SPR

U88-GRS-1924R-SPRRF Repeater

GS Instech Co., Ltd.
RF Repeater - FCC ID U88-GRS-1924R-SPR - GS Instech Co., Ltd.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Aug 10, 2010
Application Purpose
Original Equipment
Date of Application
Aug 10, 2010
Equipment Note
RF Repeater
Frequency Range
1850.00000000 - 1915.00000000
Company
GS Instech Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 1/1 ATTACHMENT E. - USER MANUAL - Sprint User Manual 3G Indoor Repeater 1/20 3G Indoor Repeater GRS-1924R-SPR User Manual May, 2010 Version 0.1 Sprint User Manual 3G Indoor Repeater 2/20 - INDEX - 1. SUMMARY................................................................................... 3 2. SYSTEM CONFIGURATION ......................................................... 3 2.1 GRS-1924R-SPR Service Organization....................................................... 3 2.2 System Design and Operation.................................................................... 3 3. SPECIFICATIONS ....................................................................... 3 3.1 System Specifications(Applicable to both Uplink & Downlink).................. 3 3.2 Electrical and Environmental Specifications .............................................. 3 3.3 Functions ................................................................................................... 3 4. SET UP ........................................................................................ 3 4.1 System Set up ............................................................................................ 3 4.2 Troubleshooting......................................................................................... 3 Sprint User Manual 3G Indoor Repeater 3/20 1. SUMMARY GRS-1924R-SPR is an Digital RF repeater, which improves PCS network. GRS-1924R-SPR receives RF signal from BTS and transmits it to the blanked and shadowed area, thus providing and improving voice and image data services. GRS-1924R-SPR’s goal is to support BTS’s functions proportionately. GRS-1924R-SPR communicates with BTS wirelessly, thus saving additional costs for its maintenance. GRS-1924R-SPR consists of RF/IF part module, Digital Filter module, and I/O & Control module divisions, which are supplied with Alarm LED, thus providing quick and easy maintenance and troubleshooting of the repeater. This manual describes in general structure of GRS-1924R-SPR, its application, maintenance and troubleshooting, installation and operation etc. Abbreviation PCS : Personal Communication System RF: Radio Frequency BTS: Base Transceiver Station IF: Intermediate Frequency I/O : Input/Output Sprint User Manual 3G Indoor Repeater 4/20 2. System Configuration 2.1 GRS-1924R-SPR Service Organization GRS-1924R-SPR decreases blanked and shadowed areas and extends cell coverage by re-trans mitting signal. The signal is received from BTS via Antenna directly, thus excluding additional ex penses for signal transmission (like cabling). Service organization of CDMA In-building RF repeat er is shown at the picture below. Donor Antenna is directed to BTS, and being divided at Servic e Antennas are installed in the building and parking place. Pass Loss should be taken into consi deration while dividing and cabling. <Pic.1> US PCS 1900 Service Organization Sprint User Manual 3G Indoor Repeater 5/20 2.2 System Design and Operation 2.2.1 System Design <Pic.2> GRS-1924R-SPR Repeater Sprint User Manual 3G Indoor Repeater 6/20 <Pic.3> Internal Design NO DESCRIPTION ① CAVITY FILTER - (Frequency Filtering) ② CONVERTER MODULE - (Frequency Conversion) ③ PSU MODULE(RS-100-9) - (Converter, LED, NMS Power Supply) ④ PSU MODULE(RS-35-12) - (EMB Power Supply) ⑤ I/O BOARD - (Input/Output Board) ⑥ NMS BOARD - (System Control Board) ⑦ DIGITAL FILTER - (Digital Filtering) ⑧ ETHERNET BOARD - (Web UI Board) Sprint User Manual 3G Indoor Repeater 7/20 ⑦ ①② ③ ④ ⑤ ⑥ ⑦ ①② ③ ④ ⑤ ⑥ <Pic.4> Outside Port Design NO DESCRIPTION ① DONOR ANT PORT ② SERVER ANT PORT ③ POWER SWITCH PORT ④ AC POWER PORT ⑤ CLI MONITOR PORT ⑥ ETHERNET PORT ⑦ DC POWER PORT Sprint User Manual 3G Indoor Repeater 8/20 2.2.2 Downlink Path Downlink and Uplink Gain Budgets have similar structure. In case of Downlink Path, RF signal is received from Donor Antenna, and through FWD division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through FWD PAM, after that the signal is transmitted to User through Server Antenna. Two attenuators use for AGC compensation. AGC attenuation range is 40dB. <Pic.5> Downlink Block Diagram Sprint User Manual 3G Indoor Repeater 9/20 2.2.3 Uplink Path Uplink Path is similar in structure to Downlink Path. In case of Uplink Path, RF signal is received from Server Antenna, and through RVS division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through RVS PAM, after that the signal is transmitted to BTS through Donor Antenna. Two attenuators use for ALC compensation. ALC attenuation range is 40dB. <Pic.6> Uplink Block Diagram Sprint User Manual 3G Indoor Repeater 10/20 2.2.4 US PCS Frequency Selection 1930 ABCDEFG 194519501965 1970 1975 1990 1995 < Forward Band Structure > f (MHz) 1930 ABCDEFG 194519501965 1970 1975 1990 1995 < Forward Band Structure > f (MHz) 1850 ABCDEFG 1865 18701885 1890 1895 1910 1915 f (MHz) < Reverse Band Structure > 1850 ABCDEFG 1865 18701885 1890 1895 1910 1915 f (MHz) < Reverse Band Structure > <Pic.7> 1900MHz PCS Band Structure GRS-1924R-SPR has 5MHz, 10MHz, 15MHz, 20MHz Paths in IF division, so any of these bandwid ths can be chosen for providing service. ITEM BANDWIDTH NOTE 5MHz 10MHz 15MHz 20MHz 5MHz + 5MHz 5MHz + 5MHz + 5MHz 10MHz + 5MHz Band Select 15MHz + 5MHz Any of these bandwidths from A to G can be chosen Also, by adding Channel Select Function, it enables users to select bands sophisticatedly. Each b and has 1.25MHz Bandwidth and if users select all the 15 bands, GRS-1924R-SPR can serve 18. 75MHz bandwidth to users. Sprint User Manual 3G Indoor Repeater 11/20 3. SPECIFICATIONS 3.1 System Specifica…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 GS Instruments Co., Ltd. August 6, 2010 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, GS Instruments Co.,Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): RF Repeater, GRS-1924R-SPR (FCC ID U88-GRS-1924R-SPR) We af firm that between SIEMIC and GS Instruments Co.,Ltd. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Applicant’s Company : GS Instruments Co.,Ltd. Address : 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea FCC ID: U88-GRS-1924R-SPR

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 GS Instruments Co.,Ltd.. To: Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID U88-GRS-1924R-SPR We hereby request confidential treatment of information accompanying this application as outlined below: COMNFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Schematics 3 Operational Description 4 Part List CONFIDENTIAL 5 Internal Photos 6 External Photos 7 Test-Setup Photos SHORT-TERM CONFIDENTIAL 8 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Applicant’s Company : GS Instruments Co.,Ltd. Address : 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea

External Photos

FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 1/7 ATTACHMENT B. -EXTERNAL PHOTOS - FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 2/7 (Front) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 3/7 (Back) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 4/7 (Left) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 5/7 (Right) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 6/7 (Lower Side) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 7/7 (Upper Side)

ID Label/Location Info

FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 1/3 ATTACHMENT A. - ID LABEL INFORMATION AND LOCATION PHOTOS - FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 2/3 1.1 ID Label Information Following is a copy of the label that will be placed on the rear side of the cabinet. Both the FCC ID and compliance statement are included in the product label Figure 1.1 PRODUCT LABEL Model No : GRS-1924R-SPR FCC ID : U88-GRS-1924R-SPR EUT Type : RF Repeater Serial No : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference , and (2) this device must accept any interference received, Includin g interference that may cause undesired operation. GS Instruments Co., Ltd.. 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea MADE IN KOREA FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 3/3 1.2 Label Location Photos The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Figure 1.2 LABEL LOCATION LABEL

Internal Photos

FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 1/20 ATTACHMENT F. - INTERNAL PHOTOS - FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 2/20 (Cavity Filter_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 3/20 (Cavity Filter_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 4/20 (Cavity Filter_3) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 5/20 (Cavity Filter_4) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 6/20 (NMS BOARD_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 7/20 (NMS BOARD_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 8/20 (Converter Module RX_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 9/20 (Converter Module RX_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 10/20 (Converter Module TX_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 11/20 (Converter Module TX_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 12/20 (Digital Filter) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 13/20 (Ethernet Board_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 14/20 (Ethernet Board_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 15/20 (IO Board_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 16/20 (IO Board_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 17/20 (LED_1) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 18/20 (LED_2) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 19/20 (PAM Module) FCC ID : U88-GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1007FR29 20/20 (PSU)

RF Exposure Info

HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 1 /2- RF EXPOSURE STATEMENT 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 2 /2- Max Peak output Power at antenna input terminal 24.04 dBm Max Peak output Power at antenna input terminal 253.51286 mW Prediction distance 20.00000 cm Prediction frequency 1872.5 MHz Antenna Gain(typical) 12.00000 dBi Antenna Gain(numeric) 15.84893 - Power density at prediction frequency (S) 0.79934 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.00000 mW/cm 2 3. RESULTS The power density level at 20 cm is 0.79934 mW/cm², which is below the uncontrolled exposure limit of 1.0 mW/cm² at 1872.5 MHz for PCS band. Warning: In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, it must also have a minimum distance of 20 cm from the body during normal operation.

Test Report

Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 1 /34- CONTENTS 1. CLIENT INFORMATION ............................................................................................................................................ 2 2. TEST SPECIFICATIONS ........................................................................................................................................... 3 3. STANDARDS ENVIRONMENTAL TEST CONDITIONS ...................................................................................... 4 4. TEST EQUIPMENT ..................................................................................................................................................... 5 5. RF OUTPUT POWER ................................................................................................................................................. 6 6. OCCUPIED BANDWIDTH ....................................................................................................................................... 11 7. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL ........................................................... 18 8. FIELD STRENGTH OF SPURIOUS RADIATION ................................................................................................ 30 9. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ...................................... 32 Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 2 /34- 1. CLIENT INFORMATION The EUT has been tested by request of Company GS Instruments Co., Ltd Contact Point 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea  EUT Type: RF Repeater  FCC ID: U88-GRS-1924R-SPR  Frequency Ranges: Downlink : 1930 - 1995 MHz Uplink : 1850 - 1915 MHz  RF Output Power: Downlink : 24.0 dBm Uplink : 24.0 dBm  FCC Rules Part(s): CFR Title 47 Part 24 Sub Part E  Emission Designators: 1M26F9W Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 3 /34- 2. TEST SPECIFICATIONS 2.1 Standards The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance With Part 27 Subpart C. Reference Description Results §2.1046, §24.232 RF Power Output Compliant §2.1047 Modulation Characteristics N/A §2.1049 Occupied Bandwidth Compliant §2.1051, §24.238 Spurious Emissions at Antenna Terminals Compliant §2.1053, §24.238 Radiated Spurious Emissions Compliant §2.1055, §24.235 Frequency Stability Compliant Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 4 /34- 3. STANDARDS ENVIRONMENTAL TEST CONDITIONS Temperature : + 15 °C to + 35 °C Relative humidity: 30 % to 60 % Air pressure 860 mbar to 1060 mbar Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 5 /34- 4. TEST EQUIPMENT Manufacturer Model / Equipment Cal Interval Calibration Due Serial No. Agilent E4438C /Signal Generator Annual 12/15/2010 MY42082646 Agilent E4416A /Power Meter Annual 01/14/2011 GB41291412 WEINSCHEL 67-30-33/ATTENUATOR Annual 01/14/2011 BR0530 Korea Eng KR-1005L/ Temperature and Humidity Chamber Annual 12/28/2010 KRAC05063-3CH Agilent N9020AA /Signal Analyzer Annual 03/03/2011 US46220219 Schwarzbeck VULB 9168/BI-LOG Antenna Biennial 01/06/2011 9168-200 HD MA240/ Antenna Position Tower N/A N/A 556 EMCO 1050/ Turn Table N/A N/A 114 HD GmbH HD 100/ Controller N/A N/A 13 HD GmbH KMS 560/ SlideBar N/A N/A 12 MITEQ AFS44-00102650-42-10P44-PS Annual 04/05/2011 1532439 Schwarzbeck BBHA 9120D/ Horn Antenna Biennial 04/13/2011 147 Schwarzbeck BBHA 9120D/ Horn Antenna Biennial 09/23/2010 296 EMCO 6502/Loop Antenna Biennial 01/13/2012 9009-2536 Agilent E4438C /Signal Generator Annual 12/15/2010 MY42082646 Report No.: HCTR1007FR29 FCC ID: U88-GRS-1924R-SPR DATE : July 30, 2010 HCT Co., Ltd. San 136-1, Ami-ri , Bubal-eup, Icheon-si, Kyounki-do, 467-701,Korea TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr - 6 /34- 5. RF OUTPUT POWER 5.1 Test Procedure Test Requirements: § 2.1046 Measurements required: RF power output: § 2.1046 (a) For transmitters other than single sideband, independent sideband and controlled carrier radiotelephone, power output shall be measured at the RF output terminals when the transmitter is adjusted in accordance with the tune-up procedure to give the values of current and voltage on the circuit elements specified in § 2.1033(c)(8).The electrical characteristics of the radio frequency load attached to the output terminals when this test is made shall be stated. § 2.1046 (b) For single sideband, independent sideband, and single channel, controlled carrier radiotelephone transmitters, the procedure specified in paragraph (a) of this section shall be employed and, in addition, the transmitter shall be modulated during the test as specified and as applicable in § 2.1046 (b) (1-5). In all tests, the input level of the modulating signal shall be such as to develop rated peak envelope power or carrier power, as appropriate, for the transmitter. § 2.1046 (c) For measurements conducted pursuant to paragraphs (a) and (b) of this section, all calculations and methods used by the applicant for determining carrier power or peak envelope power, as appropriate, on the basis of measured power in the radio frequency load attached to the transmit…

Text truncated - open the document above for the full version.

Test Report

MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 2/22 TABLE OF CONTENTS PAGE REPORT COVER 1 TABLE OF CONTENTS 2 1. SCOPE 3 2. INTRODUCTION (SITE DESCRIPTION ) 4 3. PRODUCTION INFORMATION 3.1 Equipment Description 5 4. DESCRIPTION OF TESTS (CONDUCTED) 6 5. DESCRIPTION OF TESTS (RADIATED) 7 6. LIST OF PERIPHERAL EQUIPMENT 6.1 Cable Description 6.2 Noise Suppression Parts on Cable. (I/O CABLE) 8 – 9 7. CONDUCTED MEASUREMENT PHOTO 10 8. RADIATED MEASUREMENT PHOTO 11 9. PRELIMENARY TEST 12 10. TEST DATA (CONDUCTED) 13 – 17 11. TEST DATA (RADIATED) 18 12. SAMPLE CALCULATIONS 12.1 Example 1 12.2 Example 2 19 13. TEST EQUIPMENT 20 14. TEST SOFTWARE USED 21 15. CONCLUSION 22 MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 3/22 MEASUREMENT REPORT 1. Scope Measurement and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission. • MODEL : GRS-1924R-SPR • Equipment Class: All other Devices • EUT Type: RF Repeater • Rule Part(s): FCC Part 15 Subpart B • Test Procedure(s): ANSI C63.4 (2003) • Dates of Tests: July,29, 2010 • Place of Tests: 254-1,MAEKOK-RI,HOBUP-MYUN,ICHON-SI,KYOUNGKI-DO,467-701,KOREA Applicant Name: Address: GS Instruments Co., Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200 Korea MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 4/22 2. Introduction The measurement procedure described in American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 ㎑ to 40 ㎓(ANSI C63.4-2003) was used in determining radiated and conducted emissions emanating from RF Repeater, manufactured by GS Instruments Co., Ltd., MODEL: GRS-1924R-SPR The open area test site and conducted measurement facility used to collect the radiated data are located at the 254-1, MAEKOK-RI, HOBUP-MYUN, ICHON-SI, KYOUNGKI-DO, 467-701, KOREA. The site is constructed in conformance with the requirements of ANSI C63.4and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated June 10, 2009 (Confirmation Number: 90661) MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 5/22 3. Product Information 3.1 Equipment Description Equipment Under Test (EUT) is RF Repeater, manufactured by GS Instruments Co., Ltd. (MODEL: GRS-1924-SPR) ITEM SPECIFICATION Power & Consumption 100 ~ 240 VAC, 60 Hz Connector Type N-type female Size 289 X 385 X 180 Weight max 40 lbs Reliability, MTBF 100,000 h Enclosure NEMA4 Operating Temperature -10 °C ~ +50 °C Rel. Humidity 0 % ~ 90 % Industry Standards TIA-97, TIA-98, IS-98D, IS-2000 Regulatory Approvals FCC, Part24 CDN-IC Safety Approvals UL1950 or Equiv MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 6/22 4. Description of Tests(Conducted) Conducted Emissions The line-conducted facility is located inside a 3.6 m(W) × 4.6 m(L) × 2.2 m(H) shielded enclosure and meets the requirements of ANSI C63.4 The EUT was placed on a non-conducting a 1 m × 1.6 m table which is placed 40 ㎝ away from the vertical wall and 1.5 m away from the sidewall of the shielded room. The EUT is powered from a Rohde & Schwarz 50Ω/50μH Line-impedance Stabilization Networks (LISNs) and the peripheral equipment is powered from the Rohde & Schwarz LISN. All interconnecting cables more than 1 meter were shortened to 40 ㎝ length by non-inductive bundling (figure eight fashion). Sufficient time for the EUT, the peripheral equipments and test equipment were allowed in order for them to warm up to their normal operating condition. The RF output of the LISN was connected to the spectrum analyzer to determine the frequency producing the maximum electromagnetic emission from the EUT. The EUT, peripheral equipment and interconnecting cables were arranged and manipulated to maximize each electromagnetic emission. Each emission was maximized by: switching power lines varying the mode of operation or resolution; scrolling H pattern to the EUT and/or peripheral equipment; whichever determined the worst-case emission. Each electromagnetic emission was listed on Table 1. Conducted FCC Class A. EMI CONDUCTED EMISSIONS CISPR 22 CLASS A Limits dB㎶ Freq. Range CISPR 22 Quasi-Peak CISPR 22 Average 150 ㎑ - 0.5 ㎒ 79 66 5 ㎒ – 30 ㎒ 66 56 Table 1. EMI Conducted Limits MODEL: GRS-1924R-SPR HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL: +82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.: HCTE1008FE01 7/22 5. Description of Tests (Radiated) Radiated Emissions Preliminary measurements were made indoors at 3-meter using broadband antennas, broadband amplifiers, and spectrum analyzers to determine the frequency producing the maximum electromagnetic emission. Appropriate precaution was taken to ensure that all electromagnetic emission from the EUT were maximized and investigated. The spectrum was scanned from 30 to 1000 ㎒ using a Tri-log antenna and above 1 ㎓ linearly polarized horn antennas were used. Final measurements were made outdoors at 3-meter or 10-meter test range using Tri-log antenna. The test equipment was placed on a wooden table situated on a 1.5 m × 2 m area adjacent to the measurement area. Sufficie…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Guanyong Jung
[email protected]+82328705525Fax: +82328705640

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.92 GHz250.00 mWF9WAmp
Confidentiality
Long Term
Grant Notes
CDMA RF Repeater. Power Output is maximum single channel conducted. Professional Installation is required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from GS Instech Co., Ltd.

Cell Phone Signal Booster - FCC ID U88-HOME7500 - GS Instech Co., Ltd.
U88-HOME7500

Cell Phone Signal Booster

Feb 09, 2020

Equipment Class

B2W - Part 20 Wideband Consumer Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-D - GS Instech Co., Ltd.
U88-SMR-IP10-D

In-Building RF Repeater

May 12, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-S - GS Instech Co., Ltd.
U88-SMR-IP10-S

In-Building RF Repeater

May 12, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
In-Building RF Repeater - FCC ID U88-SMT-I33 - GS Instech Co., Ltd.
U88-SMT-I33

In-Building RF Repeater

May 04, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
CDMA In-Building RF Repeater - FCC ID U88-SMT-C33 - GS Instech Co., Ltd.
U88-SMT-C33

CDMA In-Building RF Repeater

Nov 21, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter