Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
May 24, 2011
Application Purpose
Original Equipment
Date of Application
May 24, 2011
Equipment Note
In-Building Repeater
Frequency Range
1930.00000000 - 1995.00000000
Company
GS Instech Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SpeedCell Repeater INSTALLATION GUIDE Ver. 1.0 SpeedCellRepeater Installation Guide Ver. 1.0 Contents of Box ContentsPictureQuantityContentsPictureQuantity SpeedCell Repeater System PSU Unit 4.3”(W) x 16.9”(H) x 10.7”(D) , 15 lbs DFM Unit 2.8”(W) x 16.9”(H) x 10.7”(D), 9.9 lbs 1900 AMP Unit 3.9”(W) x 16.9”(H) x 10.7”(D), 15.2 lbs 1EA Ground Cable 6.6ft (2m) 1EA Power Cord 5.9ft (1.8m) 1EA Ethernet Cable 6.6ft (2m) 1EA Mounting Bracket 23.2”(W) x 18.5”(H) x 2.75”(D), 23.5 lbs 1EA Lag Screw 1/2” x 2” 4EA CD which contains - User Manual - Installation Guide 1EA Ground Sems Screw M4 x 8mm 4EA RF Cable Set Front RF Cable 2EA, Top RF Cable 4EA, Reference Cable 3EA 1EA Mounting Sems Screw M6 x 10mm 8EA 3 UL/FCC: This equipment complies with UL and FCC This publication provides instruction for installing the SpeedCell repeaters. The images for the User Interface in this publication may vary from the repeater’s depending on its S/W Version. Copyright © 2011, GS Teletech, Inc. All Rights Reserved Printed in Republic of Korea Revision History Certification DateVersionChanges 03/2011version1.0 4 WARNING! EXPOSURE TO RF Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at http://www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic fields. Warnings and Hazards WARNING! ELECTRIC SHOCK Opening the BDA (bi-directional amplifier) could result in electric shock and may cause severe injury. WARNING! DAMAGE TO EQUIPMENT Operating the BDA with antennas in very close proximity facing each other could lead to severe damage to the repeater. RF EXPOSURE & ANTENNA PLACEMENT Actual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 8inch while operating near the donor and the server antennas. Also, the donor antenna needs to be mounted outdoors on a permanent structure. WARRANTY Opening or tampering the BDA will void all warranties. CAUTION: REPEATER SHOULD BE INSTALLED AS CLOSE AS POSSIBLE TO POWER SOURCE. CAUTION: THIS REPEATER IS FOR INDOOR USE ONLY AND SHOULD BE LOCATED INSIDE OF BUILDING. CAUTION: RISK OF EXPLOSION IF BATTERY ON CONTROLLER BOARD IS REPLACED WITH AN INCORRECT TYPE. CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 5 <Picture 1> Mounting the Bracket on a Wood-Framed Wall. Mounting Repeater Wood-Framed Wall • It is recommended to first attach a sheet of plywood to the wall. The sheet of plywood should be anchored to the studs in the wall. • Using a pencil, mark the location for each of the mounting bracket's four mounting holes on the plywood. • Place the mounting bracket over the four lag screws heads. • Thread a lag screw at the positions marked in step 2. Mounting Bracket Lag Screw 1/2” x 2” Wood-Framed Wall 6 Hang and Grounding <Picture 2> Hanging the PSU Unit. • Hang the PSU unit to the mounting bracket. • Locate the two Mounting Sems Screws (M6 x10mm) underneath the PSU unit. Tighten bolts until secure. Mounting Sems Screw M6 x 10mm 7 Hang and Grounding • Hang the rest of the units in the following order: 1900 AMP, DFM, 800/900 AMP. • Locate the two Mounting Sems Screws (M6 x10mm) underneath each unit. Tighten bolts until secure. <Picture 3> Hanging the Rest of Units. CAUTION Units must be hung in the following order only: PSU -> 1900 AMP -> DFM -> 800/900 AMP. 8 Hang and Grounding Ground Cable • Connect ground cables of each unit to the bracket using Ground Sems Screws (M4 x 8mm) as displayed at the picture below. CAUTION Ground cables must be properly grounded to provide both EMI and voltage surge protection for the repeater. <Picture 3> Grounding of the PSU, 1900 AMP, DFM, 800/900 AMP Units. 9 Hang and Grounding <Picture 4> Grounding the Bracket. • Locate the ground lug on the underside (or side) of the bracket. • Crimp the ground cable to the ground lug. • Route the free end of the ground cable to an approved (per local code or practice) ground source. CAUTION Ground cable must be properly grounded to provide both EMI and voltage surge protection for the repeater. 10 Position Antenna • After installing 800/900MHz and 1900MHz antennas the installer should make line of site. • Customer specifications should be followed for positioning the antennas properly. Warning: In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 20cm during normal operation. The gain of the antenna is 12 dBi. <Picture 5> An installer is directing Donor Antenna to nearby BTS to receive strong input signal. 11 RF Cable Connections: Top of The Repeater CAUTION Do not connect or disconnect cable from ANT port when power is ON. • Connect the 800/900 and 1900 Donor Antennas to their corresponding ports. • Plug in four N(M) to N(M) type RF cables as demonstrated in the picture below. AB CD AB C D <Picture 6> Top View of the Repeater. 12 RF Cable Connections: Front Side A B • Take out two SMA (M) to SMA (M) type RF cables. • Please, pay attention to cable‟s corresponding number and its color while connecting. • Connect 1900 AMP and DFM via Band 1, and 800/900 AMP and DFM via Band 2. <Picture 7> Front View of the Repeater. 13 AB RF Cable Connections: Bottom of The Repeater • Take out three SMA (M) to SMA (M) type RF cables. • While connecting the PSU and the DFM units underneath, use referenced cable and pay attention to the labels. Plug them into their corresponding outlets. • User may choose either of the two SMA ports on the bottom of the PSU to connect to the DFM. • User may choose any two of the four SMA ports on the bottom of the PSU to connect to amplifiers. CAUTION Please, pay attention while connecting PSU and DFM, PSU and 800/900 AMP, 1900 AMP units. The repeater will not work if connection is inappropriate. <Picture 8> Bottom View of the Repeater. 14 10M REF. 13 12 11 10 9 7 6 5 4 3 2 1 1415161718192…

Text truncated - open the document above for the full version.

Attestation Statements

GS Instruments Co., Ltd. #1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200 Korea TEL : +82 32 870 5621, FAX : +82 32 876 3495, Date : May 23, 2011 Federal Communication Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 SUBJECT : FCC Application for FCC ID : U88-SC-1924AMP To Whom It may Concern: We, GS Instruments Co., Ltd., hereby attest to the fact that we will apply the Declaration of Conformity procedure to the class A In-Building RF Repeater of this composite filing. Sincerely yours, Yong-il You

Cover Letter(s)

2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 GS Instruments Co., Ltd. May 20, 2011 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, GS Instruments Co.,Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): In-Building RF Repeater, GMS-1924AMP/DFU-SPR (FCC ID: U88-SC-1924AMP) We affirm that between SIEMIC and GS Instruments Co.,Ltd. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Applicant’s Company : GS Instruments Co.,Ltd. Address : 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea FCC ID : U88-SC-1924AMP

Cover Letter(s)

Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 GS Instruments Co.,Ltd.. To: Federal Communications Commiss ion Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID U88-SC-1924AMP Date: May 20,2011 We hereby request confidential treatment of information accompanying this application as outlined below: COMNFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Schematics 3 Operational Description 4 Part List & Tune Up procedure CONFIDENTIAL 5 Internal Photos 6 External Photos 7 Test-Setup Photos SHORT-TERM CONFIDENTIAL 8 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Applicant’s Company : GS Instruments Co.,Ltd. Address : 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea

ID Label/Location Info

FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1105FR09 1/2 1.1 ID Label Information Following is a copy of the label that will be placed on the rear side of the cabinet. Both the FCC ID and compliance statement are included in the product label Figure 1.1 PRODUCT LABEL Model Name : GMS-1924AMP/DFU-SPR FCC ID : U88-SC-1924AMP EUT Type : In-Building RF Repeater Serial No : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference , and (2) this device must accept any interference received, Includin g interference that may cause undesired operation. GS Instruments Co.,Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200 South Korea MADE IN KOREA FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1105FR09 2/2 1.2 Label Location Photos The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Figure 1.2 LABEL LOCATION LABEL LOCATION

Internal Photos

FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10M REF TOP 1/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10M REF BOTTOM 2/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 800_1900 IO BOARD_ TOP 3/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 800_1900 IO BOARD_ BOTTOM 4/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900_2600 LED BOARD TOP 5/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900_2600 LED BOARD BOTTOM 6/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900_CAVITY 7/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900 DNC TOP 8/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900 DNC BOTTOM 9/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900 UPC_TOP 10/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1900 UPC_BOTTOM 11/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr SCA-1902S PCB 12/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr AMP Controller _TOP 13/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr AMP Controller _BOTTOM 14/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM_DIGITAL_TOP . 15/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM_DIGITAL_BOTTOM 16/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM_LED BOARD_TOP 17/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM_LED BOARD_BOTTOM 18/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM RF MODULE _TOP 19/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr DFM RF MODULE _BOTTOM 20/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr FEU 21/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr SNMP_MAIN_TOP 22/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr SNMP_MAIN_BOTTOM 23/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr SNMP_SUB_TOP 24/25 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 25/25 SNMP_SUB_BOTTOM

RF Exposure Info

Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 35 /36- 10. RF EXPOSURE STATEMENT 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 36 /36- 2-1. PCS Downlink Max Peak output Power at antenna input terminal 23.96000 dBm Max Peak output Power at antenna input terminal 248.88573 mW Prediction distance 20.00000 cm Prediction frequency 1931.25000 MHz Antenna Gain(typical) 12.00000 dBi Antenna Gain(numeric) 15.84893 - Power density at prediction frequency (S) 0.78475 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.0 0000 mW/cm 2 2-2. PCS Uplink Max Peak output Power at antenna input terminal 24.07000 dBm Max Peak output Power at antenna input terminal 255.27013 mW Prediction distance 20.00000 cm Prediction frequency 1851.25000 MHz Antenna Gain(typical) 12.00000 dBi Antenna Gain(numeric) 15.84893 - Power density at prediction frequency (S) 0.80488 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.0 0000 mW/cm 2 3. RESULTS The power density level at 20 cm is 0.78475 mW/cm²(DownLink), 0.80488 mW/cm²(UpLink), which is below the uncontrolled exposure limit for PCS Band. Warning: In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, it must also have a minimum distance of 20 cm from the body during normal operation.

Test Report

HCT. CO., LTD. CERTIFICATION DIVISION 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO, KOREA TEL : +82 31 645 6300 FAX : +82 31 645 6401 CERTIFICATE OF COMPLIANCE (ERM EVALUATION) Manufacture: GS Instruments Co., Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea Date of Issue : May 20, 2011 Test Report No.: HCTR1105FR09 Test Site: HCT CO., LTD. FCC ID: APPLICANT: EUT Type: In-Building RF Repeater Model: GMS-1924AMP/DFU-SPR Uplink: 1930 MHz – 1995 MHz Frequency Ranges: Downlink: 1850 MHz – 1915 MHz Uplink: 24.0 dBm RF Output Power: Downlink: 24.0 dBm FCC Rules Part(s): CFR 47, Part 24 Subpart E GS Instruments Co., Ltd. U88-SC-1924AMP Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 24 Subpart E of the FCC Rules under normal use and maintenance. Report prepared by :Chang Seok Choi Test engineer of RF Team Approved by : Sang Jun Lee Manager of RF Team ▷▷▷ HCT CO., LTD. ◁◁◁ Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 2 /36- CONTENTS 1. CLIENT INFORMATION............................................................................................................................................ 3 2. TEST SPECIFICATIONS...........................................................................................................................................4 3. ST ANDARDS ENVIRONMENTA L TEST CONDITIONS...................................................................................... 5 4. TEST EQUIPMENT.....................................................................................................................................................5 5. RF OUTP UT POWER.................................................................................................................................................6 6. OC CUPIED BANDWIDTH.......................................................................................................................................1 1 7. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL........................................................... 19 8. FIELD STRENGTH OF SPURIOUS RADIATION................................................................................................ 31 9. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS...................................... 33 10. RF EXPOSURE STATEMENT.............................................................................................................................. 35 Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 3 /36- 1. CLIENT INFORMATION The EUT has been tested by request of Company GS Instruments Co., Ltd Contact Point 1385-14, Juan-Dong, Nam-Ku, Incheon,,402-200 Korea ■ FCC ID: U88-SC-1924AMP ■ APPLICANT: GS Instruments Co., Ltd. ■ EUT Type: In-Building RF Repeater ■ Model: GMS-1924AMP/DFU-SPR Uplink: 1930 MHz – 1995 MHz ■ Frequency Ranges: Downlink: 1850 MHz – 1915 MHz Uplink: 24.0 dBm ■ RF Output Power: Downlink: 24.0 dBm ■ FCC Rules Part(s): CFR 47, Part 24 Subpart E ■ Emission Designators: F9W Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 4 /36- 2. TEST SPECIFICATIONS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance With Part 24. Reference Description Results §2.1046, §24.232 RF Power Output Compliant §2.1047 Modulation Characteristics N/A §2.1049 Occupied Bandwidth Compliant §2.1051, §24.238 Spurious Emissions at Antenna Terminals Compliant §2.1053, §24.238 Radiated Spurious Emissions Compliant §2.1055 Frequency Stability Compliant Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 5 /36- 3. STANDARDS ENVIRONMENTAL TEST CONDITIONS Temperature : + 15 °C to + 35 °C Relative humidity: 30 % to 60 % Air pressure 860 mbar to 1060 mbar 4. TEST EQUIPMENT Manufacturer Model / Equipment Cal Interval Calibration Due Serial No. Agilent E4438C /Signal Generator Annual 11/11/2011 MY42082646 Agilent E4416A /Power Meter Annual 01/04/2012 GB41291412 Agilent E9327A/ Power Sensor Annual 07/23/2011 MY4442009 Korea Eng KR-1005L/ Temperature and Humidity Chamber Annual 12/28/2011 KRAC05063-3CH Agilent N9020A /Signal Analyzer Annual 03/03/2012 US46220219 WEINSCHEL 67-30-33/ATTENUATOR Annual 12/29/2011 BR0530 HD MA240/ Antenna Position Tower N/A N/A 556 EMCO 1050/ Turn Table N/A N/A 114 HD GmbH HD 100/ Controller N/A N/A 13 HD GmbH KMS 560/ SlideBar N/A N/A 12 MITEQ AMF-6D-001180-35-20P/AMP Annual 05/20/2011 990893 Schwarzbeck BBHA 9120D/ Horn Antenna Biennial 04/13/2012 147 Schwarzbeck BBHA 9120D/ Horn Antenna Biennial 09/23/2011 296 Schwarzbeck VULB 9168/TRILOG Antenna Biennial 02/09/2013 9168-200 Schwarzbeck VULB 9160/TRILOG Antenna Biennial 07/15/2012 9160-3150 Report No.: HCTR1105FR09 FCC ID: U88-SC-1924AMP DATE : May 20, 2011 HCT Co., Ltd. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL : +82 31 645 6300 FAX : +82 31 645 6401 www.hct.co.kr - 6 /36- 5. RF OUTPUT POWER 5.1 Test Procedure Test Requirements: § 2.1046 Measurements required: RF power output: §…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr (Test Setup) Report No. : HCTR1105FR09 1/2 FCC ID : U88-SC-1924AMP HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1105FR09 2/2

Contact Information

Applicant

Guanyong Jung
[email protected]+82328705525Fax: +82328705640

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.93 GHz - 2.00 GHz255.00 mWF9WAmp
Confidentiality
Long Term
Grant Notes
CDMA RF Repeater. Power Output is maximum single channel conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Approval is for maximum gain 12.0 dBi antennas as shown in this filing. Installations with higher gain or co-located antennas require RF exposure to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3).

Other Applications from GS Instech Co., Ltd.

Cell Phone Signal Booster - FCC ID U88-HOME7500 - GS Instech Co., Ltd.
U88-HOME7500

Cell Phone Signal Booster

Feb 09, 2020

Equipment Class

B2W - Part 20 Wideband Consumer Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-D - GS Instech Co., Ltd.
U88-SMR-IP10-D

In-Building RF Repeater

May 12, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-S - GS Instech Co., Ltd.
U88-SMR-IP10-S

In-Building RF Repeater

May 12, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
In-Building RF Repeater - FCC ID U88-SMT-I33 - GS Instech Co., Ltd.
U88-SMT-I33

In-Building RF Repeater

May 04, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
CDMA In-Building RF Repeater - FCC ID U88-SMT-C33 - GS Instech Co., Ltd.
U88-SMT-C33

CDMA In-Building RF Repeater

Nov 21, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter