FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN TENDA TECHNOLOGY CO., LTD./
  3. V7TCP3V32

V7TCP3V323MP Security Pan/Tilt Camera

SHENZHEN TENDA TECHNOLOGY CO., LTD.
3MP Security Pan/Tilt Camera - FCC ID V7TCP3V32 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 29, 2026
Application Purpose
Original Equipment
Equipment Note
3MP Security Pan/Tilt Camera
Frequency Range
2402.00000000 - 2480.00000000
Company
SHENZHEN TENDA TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Ver:X.X MAC: XXXXXXXXXX S/N: XXXXXXXXXXXXXXX UUID: XXXXXXXXXX 3MP Security Pan/Tilt Camera Model: CP3 Power: 5V 1A Spec: 4mm FCC ID: V7TCP3V3 Shenzhen Tenda Technology Co., Ltd. 6-8 Floor, Tower E3, No.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Made in China For more FAQs, please scan the QR code in the Video and More Info section. Q1. What should I do if I failed to add the camera to the TDSEE App Quick Installation Guide 3MP Security Pan/Tilt Camera CP3/CP3V3 Video and More Info Scan the QR code or visit www.tendacn.com for installation videos, technical specifications, user guides, Symbols on Products and Materials, and more information. You can see the product name and model on the product label. The label can be found on the device body. https://www.tendacn.com/product/help/cp3-v32 1× 2×2× 1×1×1× 1× Tips − Before adding the camera, make sure the router is successfully connected to the internet and that internet access filtering and authentication functions are disabled. − When adding the camera, ensure your phone is connected to the router's 2.4 GHz Wi-Fi. Tips − Make sure the ceiling is strong enough to withstand three times the weight of the camera. − Install the camera where the router has good Wi-Fi signal. Note: For initial setup or after a reset, set new login password for privacy and security (The longer the password, the stronger the protection). The character limit and composition rules for passwords are subject to software user interface prompts. Router Internet Router Internet Power outlet Power outlet Manage the Camera Appearance Safety Precautions CE Mark Warning Operating Frequency/Max Output Power FCC Statement RECYCLING Australia Cyber Security SoC Australia Cyber Security SoC V1.0 Keep for future reference. FAQ After the camera works properly, you can manage the camera through TDSEE App or web UI. (Scan the QR code of Video and More Info in this guide to obtain the related user guide.) To log in to the web UI: 1. After the camera connects to the router via Wi-Fi, connect your computer to the router with an Ethernet cable or via Wi-Fi. 2. Set the computer's IP address to the same subnet as the camera (but not identical). Usually, the computer is set to Obtain an IP address automatically, which allows it to acquire an IP address in the same subnet without manual configuration. After adding the camera to the TDSEE App, tap the top-right settings icon ( ) of the App, and go to Device Info > IP Address to view its IP. You can also download the Tenda Security Search Tool from www.tendacn.com, and use it to discover the device and obtain the camera’s IP address. 3. Start a browser and enter the camera's IP address in the address bar to access the login page. The default username is admin, and the default password is printed on the label; if not available, the universal default password is admin123456. Micro SD Reset       Indicator Solid red: Initializing and starting. Blinking red slowly: Disconnected from the network. Blinking red quickly: Connecting to the network. Solid blue: Connected to the network. Blinking blue slowly: Upgrading. Blinking blue quickly: Waiting to connect to the network. Micro SD card slot Insert the Micro SD card to store the monitoring videos. Reset button Reset method: Hold down the reset button for about 5 seconds and release it after the indicator blinks blue quickly or you hear a prompt tone. The camera is reset to factory settings successfully. Type C power jack Used to connect to the included power adapter and power cord. Microphone Speaker − Ensure that the router is connected to the internet. − The camera supports 2.4 GHz Wi-Fi only. Connect your phone to a 2.4 GHz Wi-Fi when adding the camera. − Do not hide the router’s Wi-Fi when adding the camera (You may hide it after the camera is added.). − Before adding the camera, make sure the indicator is blinking blue quickly. If not, reset the camera and try again. Q2. What should I do when the video preview is not smooth − Ensure that the router’s Wi-Fi is smooth. − Take the router closer to the camera. − When previewing video over cellular data, ensure the smartphone has a stable internet connection. − Video preview supports Fluent and HD. Adjust the video quality based on network conditions: open the TDSEE App, select the camera, and tap the image-quality switch in the upper-right corner of the live view. Q3. How to store the videos Method 1: Install a Micro SD card in the camera. Recording modes include Alarm Recording and All-Day Recording (default: Alarm Recording). You can change the mode as required. When installing a Micro SD card for the first time, format it as prompted by the app. Method 2: Subscribe to the Cloud Storage Service in TDSEE App. Open the app, select the camera on the homepage, and tap Cloud Storage in the lower-left corner. Method 3: Connect the camera to an NVR for recording. The camera supports ONVIF and can be added to the NVR via a wired or wireless connection. The default username is admin, and the default password is printed on the label; if not available, the universal default password is admin123456. Before operating, read and follow these precautions to prevent accidents. − For desktop mounting, the camera must be horizontally mounted for safe use. − For ceiling mounting, the camera is suitable for mounting at heights >2m. − Do not use the device in a place where wireless devices are not allowed. − Use the included power adapter and power cord. − The mains plug is used as the disconnect device, and shall remain readily operable. − The power socket shall be installed near the device and easily accessible. − Operating temperature: -10°C- +45°C (14°F to 113°F). Power adapter operating temperature: 0°C - 40°C (32°F - 104°F). − Keep the device away from water, fire, high electric field, high magnetic field, and inflammable and explosive items. − Keep this device out of reach of children to prevent children from using it as a toy an…

Text truncated - open the document above for the full version.

Attestation Statements

       !"# $%# &## "# '"(')( *  ' # ++, -++,-+-.#/-++,-+-- 0#')(1( #)   23345363789:4334;  #(,,  &  <<=> >  << >>  %('*#(' # ?#%#(' '?'"'  -@+ #A# <'"&# %0B'#<,@  #'<##0  %C%)(<D)%'($D# E'( #0#0 D >F- DF, G0#A(' !C%C"('"C%)( $"%CC("H <E,<E,+AE+A,@ I'' J,@,,@,<*,BE!E ,E @E#/,E#/@0"K,#/0 $"%CC("G%&=#  " L("%CC (C#('#&=(G% )(' "B# "# 0"#"'"#B(%" B$0# %G#)(%' ("G(#( %"#" )#C#B''($(#)('?#('(  ' )$  D' (#0  % '( !'  

Attestation Statements

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

Cover Letter(s)

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

Cover Letter(s)

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

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 1 of 6 EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 2 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 3 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 4 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 5 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-EXP Page 6 of 6

ID Label/Location Info

Ver:X.X MAC: XXXXXXXXXX S/N: XXXXXXXXXXXXXXX UUID: XXXXXXXXXX 3MP Security Pan/Tilt Camera Model: CP3 Power: 5V 1A Spec: 4mm FCC ID: V7TCP3V32 Shenzhen Tenda Technology Co., Ltd. 6-8 Floor, Tower E3, No.1001, Zhongshanyuan Road,Nanshan District, Shenzhen, China. 518052 Made in China Scan to add device

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 1 of 7 EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 2 of 7 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 3 of 7 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 4 of 7 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 5 of 7 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 6 of 7 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-INP Page 7 of 7 ANT

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 24 of 138 Version 4.1 RF EXPOSURE EVALUATION MPE-Based Exemption Applicable Standard According to subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 v01 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. R is the minimum separation distance in meters f = frequency in MHz For multiple RF sources: Multiple RF sources are exempt if: in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 25 of 138 Version 4.1 Result Antenna Gain # ERP Mode Frequency (MHz) Tune up conducted power # (dBm) (dBi)(dBd)(dBm)(mW) Evaluation Distance (m) ERP Limit (mW) BLE2402-24809.5 2.710.56 10.06 10.14 0.2768 2.4G Wi-Fi 2412-246225.02.710.56 25.56 359.75 0.2768 Note 1: The tune up conducted power and antenna gain was declared by the applicant. Note 2: The BLE and 2.4G Wi-Fi cannot transmit at same time. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant

Test Report

SHENZHEN TENDA TECHNOLOGY CO.,LTD. Measurement of Antenna for CP3 Project Manufacture:SHENZHEN TENDA TECHNOLOGY CO.,LTD. 6-8 Floor, Tower E3, No.1001,Zhongshanyuan Road, Nanshan District, Shenzhen, China.518052 Model:CP3 PCB Antenna 1. Antenna Appearance: 2. Electrical performance test results at normal temperature SHENZHEN TENDA TECHNOLOGY CO.,LTD. a)2.4G Antenna No Test Item Unit Demand PerformanceTest Result Judgement 1 Frequency Range MHz 2400-2483 2400-2483 OK 2 Gain dBi 2.71 2410 2.53 OK 2450 2.62 OK 2483 2.66 OK 3 Return loss dB ≤-10 2412 -27 OK 2450 -25 OK 2483 -26 OK Directional diagram for 2.4GHz EUT Remark Frequency E Total. dBi(dB) Efficiency( ) 2400MHz 2.5457% 2410MHz 2.5355% 2420MHz 2.6254% 2430MHz 2.6554% 2440MHz 2.5854% 2450MHz 2.6259% 2460MHz 2.7160% 2470MHz 2.4955% 2480MHz 2.6660% 2490MHz 2.5755% H PLANE V PLANE 2D Radiation patterns Frequency:2460MHz 2.4G Return loss test SHENZHEN TENDA TECHNOLOGY CO.,LTD.

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF003 Page 1 of 131 Version 4.1 TEST REPORT Applicant Name:SHENZHEN TENDA TECHNOLOGY CO., LTD. Address:6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Report Number:2601S26098E-RF-00A FCC ID:V7TCP3V32 Test Standard (s) FCC PART 15.247 Sample Description Product Type:3MP Security Pan/Tilt Camera Model No.:CP3 Multiple Model(s) No.:N/A Trade Mark:Tenda Date Received:2026-04-22 Issue Date:2026-06-16 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Wills YuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00A TR-EM-RF003 Page 2 of 131 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ................................................................................................................................9 TEST EQUIPMENT LIST ..........................................................................................................................................10 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................12 AC LINE CONDUCTED EMISSIONS...............................................................................................................................12 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................14 6 DB EMISSION BANDWIDTH & 99% OCCUPIED BANDWIDTH....................................................................................17 PEAK OUTPUT POWER MEASUREMENT .......................................................................................................................19 POWER SPECTRAL DENSITY ........................................................................................................................................20 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................21 CONDUCTED SPURIOUS EMISSION...............................................................................................................................22 DUTY CYCLE ...............................................................................................................................................................23 RF EXPOSURE EVALUATION ................................................................................................................................24 ANTENNA REQUIREMENT .....................................................................................................................................26 TEST DATA AND RESULTS .....................................................................................................................................27 AC LINE CONDUCTED EMISSIONS...............................................................................................................................27 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................30 6DB EMISSION BANDWIDTH......................................................................................................................................105 99% OCCUPIED BANDWIDTH ....................................................................................................................................109 MAXIMUM CONDUCTED OUTPUT POWER .........................................................................................…

Text truncated - open the document above for the full version.

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF004 Page 1 of 138 Version 4.1 TEST REPORT Applicant Name:SHENZHEN TENDA TECHNOLOGY CO., LTD. Address:6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Report Number:2601S26098E-RF-00B FCC ID:V7TCP3V32 Test Standard (s) FCC PART 15.247 Sample Description Product Type:3MP Security Pan/Tilt Camera Model No.:CP3 Multiple Model(s) No.:N/A Trade Mark:Tenda Date Received:2026-04-22 Issue Date:2026-06-16 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Wills YuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 2 of 138 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ................................................................................................................................9 TEST EQUIPMENT LIST ..........................................................................................................................................10 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................12 AC LINE CONDUCTED EMISSIONS...............................................................................................................................12 SPURIOUS EMISSIONS ..................................................................................................................................................14 6 DB EMISSION BANDWIDTH & 99% OCCUPIED BANDWIDTH ....................................................................................17 MAXIMUM CONDUCTED OUTPUT POWER ...................................................................................................................19 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................20 CONDUCTED SPURIOUS EMISSION...............................................................................................................................21 POWER SPECTRAL DENSITY ........................................................................................................................................22 DUTY CYCLE ...............................................................................................................................................................23 RF EXPOSURE EVALUATION ................................................................................................................................24 ANTENNA REQUIREMENT .....................................................................................................................................26 TEST DATA AND RESULTS .....................................................................................................................................27 AC LINE CONDUCTED EMISSIONS...............................................................................................................................27 SPURIOUS EMISSIONS ..................................................................................................................................................30 6DB EMISSION BANDWIDTH......................................................................................................................................110 99% OCCUPIED BANDWIDTH ....................................................................................................................................115 MAXIMUM CONDUCTED OUTPUT POWER .........................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 101 of 138 Version 4.1 Right Band edge_Vertical_802.11ax-HE20 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 102 of 138 Version 4.1 Left Band edge_Horizontal_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 103 of 138 Version 4.1 Left Band edge_Horizontal_Average_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 104 of 138 Version 4.1 Left Band edge_Vertical_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 105 of 138 Version 4.1 Left Band edge_Vertical_Average_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 106 of 138 Version 4.1 Right Band edge_Horizontal_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 107 of 138 Version 4.1 Right Band edge_Horizontal_Average_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 108 of 138 Version 4.1 Right Band edge_Vertical_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 109 of 138 Version 4.1 Right Band edge_Vertical_Average_802.11ax-HE40 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 110 of 138 Version 4.1 6dB Emission Bandwidth Test Information: Sample No.:3KL9-2Test Date:2026/05/15~2026/06/03 Test Site:RFTest Mode:Transmitting Tester:Barry FengTest Result:Pass Environmental Conditions: Temperature: (°C) 24 Relative Humidity: (%) 45 ATM Pressure: (kPa) 100.8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 111 of 138 Version 4.1 Mode Test Frequency (MHz) Result (MHz) Limit (MHz) Verdict 241210.170≥0.5Pass 243710.170≥0.5Pass 802.11b 246210.130≥0.5Pass 241216.056≥0.5Pass 243716.096≥0.5Pass 802.11g 246216.056≥0.5Pass 241217.257≥0.5Pass 243717.297≥0.5Pass 802.11n20 246217.417≥0.5Pass 242236.436≥0.5Pass 243736.597≥0.5Pass 802.11n40 245236.517≥0.5Pass 241218.859≥0.5Pass 243718.739≥0.5Pass 802.11ax20_RU_FULL 246218.579≥0.5Pass 242237.878≥0.5Pass 243737.878≥0.5Pass 802.11ax40_RU_FULL 245237.638≥0.5Pass Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 112 of 138 Version 4.1 802.11b_2412MHz 802.11b_2437MHz 802.11b_2462MHz 802.11g_2412MHz 802.11g_2437MHz 802.11g_2462MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 113 of 138 Version 4.1 802.11n20_2412MHz 802.11n20_2437MHz 802.11n20_2462MHz 802.11n40_2422MHz 802.11n40_2437MHz 802.11n40_2452MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 114 of 138 Version 4.1 802.11ax20_2412MHz_RU_FULL 802.11ax20_2437MHz_RU_FULL 802.11ax20_2462MHz_RU_FULL 802.11ax40_2422MHz_RU_FULL 802.11ax40_2437MHz_RU_FULL 802.11ax40_2452MHz_RU_FULL Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601S26098E-RF-00B TR-EM-RF004 Page 115 of 138 Version 4.1 99% Occupied Bandwidth Test Information: Sample No.:3KL9-2Test Date:2026/05/15~2026/06/03 Test Site:RFTest Mode:Transmitting Tester:Barry FengTest Result:N/A Environmental Conditions: Temperature…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shen Yue(Engineer)
[email protected]Fax: 866-755-27657178

Technical Contact

Tenda Technology, IncSunny Chang
[email protected]

530 Technology Drive suite100 · Irvine, California, 92618 · United States

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Nana Liu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz9.00 mW
215C2.41 GHz - 2.46 GHz265.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Other Applications from SHENZHEN TENDA TECHNOLOGY CO., LTD.

6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera - FCC ID V7TCH9V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH9V2

6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
3MP Wi-Fi Pan/Tilt Camera - FCC ID V7TCH3V21 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH3V21

3MP Wi-Fi Pan/Tilt Camera

Jul 14, 2026

Equipment Class

DTS - Digital Transmission System
3MP Security Pan/Tilt Camera - FCC ID V7TCP3P1 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP3P1

3MP Security Pan/Tilt Camera

Jun 30, 2026

Equipment Class

DTS - Digital Transmission System
5MP Security Pan/Tilt Camera - FCC ID V7TCP7V21 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP7V21

5MP Security Pan/Tilt Camera

May 28, 2026

Equipment Class

DTS - Digital Transmission System
AX3000 Wi-Fi 6 Ceiling Access Point - FCC ID V7TI27V3 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TI27V3

AX3000 Wi-Fi 6 Ceiling Access Point

Apr 23, 2026

Equipment Class

DTS - Digital Transmission System