FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Amimon Ltd./
  3. VQSAMN36254

VQSAMN36254HD-SDI wireless receiver module

Amimon Ltd.
HD-SDI wireless receiver module - FCC ID VQSAMN36254 - Amimon Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Mar 12, 2013
Application Purpose
Original Equipment
Date of Application
Mar 12, 2013
Equipment Note
HD-SDI wireless receiver module
Frequency Range
5745.00000000 - 5805.00000000
Company
Amimon Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

AMN36254 (Receiver) Label:

RF Exposure Info

5.4 GHz Wideband AntennaP/N 5400AT18A1000 Detail Specification: 01/27/2011 Page 1 of 3 General Specifications Part NumberOperating Temperature Frequency RangeReel Quanity Peak Gain Average Gain Return Loss Input PowerNo.FunctionTerminal Configuration Impedance1Feeding Point 2NC Mechanical Dimensions Inmm L±± W±± T a±± Mounting Considerations Mount these devices with brown mark facing up. Units: mm *Line width should be designed to provide 50Ω impedance matching characteristics. a) Without Matching Circuits b) With Matching Circuits Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2011 Johanson Technology, Inc. All Rights Reserved Storage Temperature +5 to +35°C, Humidity:45- 75%RH, 18 mos. Max 500mW max. 50 Ω 5400AT18A1000 3,000 -40 to +85°C 8.5 dB min. -2.5 dBi typ. (XZ-V) 2.0 dBi typ. (XZ-V) 4900 - 5900 Mhz 0.20 0.500.30 +0.1/-0.2 0.063 0.051 1.60 +.004/-.008 0.008 "High Frequency Ceramic Solutions" 0.0080.1263.200.20 1.30 0.0200.012 12 L W a T * 2.6 4.2 1.6 1.9 0.4 6.8 pF 1.0 nH 2.2nH JTI P/N for Matching Circuit: Cap (6.8pF): 500R07S6R8BV4T Inductor (1.0nH): L-07C1N0SV6T Inductor (2.2nH): L-07C2N2SV6T * 2.6 4.2 1.6 1.90.4 0.8 0.8 0.8 1.7 0Ω 0Ω 5.4 GHz Wideband AntennaP/N 5400AT18A1000 Detail Specification: 01/27/2011 Page 2 of 3 Typical Electrical Characteristics (T=25 o C) Test Board: Return Loss a) Without Matching Circuitsb) With Matching Circuits Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2011 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" ) ) ) ) ) ) ) 33.5mm 6.5 19mm Matching Circuit Antenna No Ground Ground 50Ω Feed Line 39.5mm 6.5mm 6.5 4.0 5.4 GHz Wideband AntennaP/N 5400AT18A1000 Detail Specification: 01/27/2011 Page 3 of 3 Typical Radiation Patterns Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2011 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" ) ) ) ) ) ) ) ) ) XY-V/XY-H 180° 270° 0° 90° X Z Y XY-cut scanning direction XY cut @5.5GHz Vertical Horizontal XZ-V/XZ-H YZ-V/YZ-H 180° 270° 0° 90° X Z Y XZ-cut scanning direction 180° 270° 0° 90° X Z Y YZ-cut scanning direction XZ cut @5.5GHz Vertical Horizontal YZ cut @5.5GHz Vertical Horizontal

RF Exposure Info

SPECIFICATION 1. Description :WSS002 Dual Band Antenna with RP-SMA(M)(Black) 2. Model No. :WSS002 3. Standard :IEEE 802.11a+b/g Wireless LAN 4. Antenna Profile :108.5 mm (see Drawing) 5. Color :Black 6. Electrical Characteristics Operating Frequency :2.4~2.5 & 5.15~5.35 & 5.725~5.85GHz Antenna Type :Dipole Polarization Type :Linear Type of Radiation :Toroidal Peak Gain :2.0 dBi Typical Impedance :50 Ohm nominal V.S.W.R. :2.0:1 Max. 7. Mechanical Characteristics Action :Swivel Type Connector :RP-SMA(M) Core :N/A 8. Raw Material Coaxial Cable :RG-178 Housing :TPU Hinge :PC+ALLOY

RF Exposure Info

RD2458-5 RD2458-5 Electrical Data RD2458-5 VSWR Elevation Pattern 2450MHz RD2458-5 Elevation Pattern 5150MHz RD2458-5 Elevation Pattern 5725MHz RD2458-5

RF Exposure Info

global solutions : local support TM TriBand 2.4, 5.3, 5.8GHz Antenna 2400 to 5800 MHz Operation The TriBand RD2458-5 series antennas are high gain (3dB @ 2.4GHz and 5dBi@5GHz) omnidirectional antennas designed for indoor use. They are rugged and reliable. The heavy duty knuckle gives angular detents at 0, 45 and 90 degrees. The antenna features a 360 degree horizontal transmission pattern and a 90 degree vertical transmission pattern. These antennas offer a choice of connector options for maximum design flexibility (SMA, RPSMA, RPTNC and N male). Features and Benefits: • Tri-Band operation: 2.4GHz, 5.3GHz, 5.8GHz • 0, 45 and 90 degrees knuckle detents (N male not applicable) • Extends range of wireless access points or wireless bridges • Available in SMA, RPSMA, RPTNC and N male connector versions Applications • 802.11a/b/g wireless equipment • OEM equipment RD2458 www.pacwireless.com or visit: www.pacwireless.com For sales information: Telephone 801-572-3024 E-Mail [email protected] jljljlj global solutions : local support TM ANT-SPEC-RD2458-0408 Any information furnished by Laird Technologies and its agents is believed to be accurate and reliable. Responsibility for the use and application of Laird Technologies materials rests with the end user since Laird Technologies and its agents cannot be aware of all potential uses. Laird Technologies makes no warranties as to the fitness, merchantability, or suitability of any Laird Technologies materials or products for any specific or general uses. Laird Technologies shall not be liable for incidental or consequential damages of any kind. All Laird Technologies products are sold pursuant to the Laird Technologies domestic terms and conditions of sale in effect from time to time, a copy of which will be furnished upon request. Specifications subject to change without notice. Specifications Notes: • All shipments F.O.B. Schaumburg, IL 60173 • All antennas carry a 2 Year Warranty Antenna Patterns System Ordering: RD2458-5-SMA TriBand 2.4/5.3/5.8GHz Omndirectional – SMA male connector RD2458-5-RSMA TriBand 2.4/5.3/5.8GHz Omndirectional – RPSMA male connector RD2458-5-RTNC TriBand 2.4/5.3/5.8GHzOmndirectional – RPTNC male connector RD2458-5-NM TriBand 2.4/5.3/5.8GHz Omndirectional – N male connector ParameterMinTypMaxUnits Frequency Range24002483MHz Gain (RD2458-5)2400 MHz 5150 MHz 5400 MHz 5725 Mhz 3 5 5 5 dBi Gain (RD2458-5-NM)2400 MHz 5150 MHz 5725 Mhz 2.2 4 5 dBi VSWR1.5:1 Impedance50 ΩOHM Input Power10W Operating Temperature-10+70Deg C Weight (RD2458-5).8 (22.7)oz (g) Weight (RD2458-5-NM)1.6 (45.4)oz (g) Dimension (Dia x Height) - RD2458-56.1 x 0.5D (155 x 12.7D)In (mm) Dimension (Dia x Height) - RD2458-5-NM7.6 x 0.5D (193 x 12.7D)In (mm) RD2458 2450MHz Elevation Pattern5150MHz Elevation Pattern 5750MHz Elevation Pattern

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5180-5240MHz; highest conducted power = 16.92 dBm (Avg) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (<1 mW/cm 2 ) P = Power Input to antenna (49.20 mW) G = Antenna Gain (3.16) R = Minimum Distance between User and Antenna (20 cm) S = (49.20 * 3.16 )/(4*3.14*20 2 ) = 0.03 mW/cm 2 Since S < 1 mW/cm 2 , the minimum distance (R) is 20cm

RF Exposure Info

Electromagnetic Compatibility Criteria for Intentional Radiators § 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5745-5805MHz; highest conducted power = 16.63 dBm (Avg) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (<1 mW/cm 2 ) P = Power Input to antenna (46.03 mW) G = Antenna Gain (3.16) R = Minimum Distance between User and Antenna (20 cm) S = (46.03 * 3.16 )/(4*3.14*20 2 ) = 0.029 mW/cm 2 Since S < 1 mW/cm 2 , the minimum distance (R) is 20cm

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory March 11, 2013 Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, Irsael 46733 Dear Guy Dar, Enclosed is the EMC Wireless test report for compliance testing of the Amimon, Falcon RX, Amimon P/N- AMN36254 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Part 15.407 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Amimon\EMC37062B-FCC407 UNII 1 Rev. 2) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 MET Report: EMCS37062A-FCC407 © 2013, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the Amimon Model Falcon RX, Amimon P/N-AMN36254 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators MET Report: EMC37062B-FCC407 Rev. 2 March 11, 2013 Prepared For: Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, 46733 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 2 © 2013, MET Laboratories, Inc. Page i of vii Electromagnetic Compatibility Criteria Test Report for the Amimon Model Falcon RX, Amimon P/N-AMN36254 the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators Jeffrey Pratt, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules under normal use and maintenance. Asad Bajwa, Director Electromagnetic Compatibility Lab Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 2 © 2013, MET Laboratories, Inc. Page ii of vii Report Status Sheet Revision Report Date Reason for Revision  February 18, 2013 Initial Issue. 1 March 8, 2013 Revised to reflect engineer corrections. 2 March 11, 2013 Revised to reflect customer corrections. Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 2 © 2013, MET Laboratories, Inc. Page iii of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................6 E. Equipment Configuration ....................................................................................................................................6 F. Support Equipment .............................................................................................................................................7 G. Ports and Cabling Information .............................................................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory February 18, 2013 Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, Israel 46733 Dear Guy Dar, Enclosed is the EMC Wireless test report for compliance testing of the Amimon, Falcon RX, Amimon P/N- AMN36254 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Part 15.407 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Amimon\EMC37062B-FCC407 UNII 3) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 MET Report: EMCS37062A-FCC407 © 2013, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the Amimon Model Falcon RX, Amimon P/N-AMN36254 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators MET Report: EMC37062B-FCC407 February 18, 2013 Prepared For: Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, 46733 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 1 © 2013, MET Laboratories, Inc. Page i of vii Electromagnetic Compatibility Criteria Test Report for the Amimon Model Falcon RX, Amimon P/N-AMN36254 the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators Jeffrey Pratt, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules under normal use and maintenance. Asad Bajwa, Director Electromagnetic Compatibility Lab Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 1 © 2013, MET Laboratories, Inc. Page ii of vii Report Status Sheet Revision Report Date Reason for Revision  February 18, 2013 Initial Issue. 1 March 8, 2013 Revised to reflect engineer corrections. Electromagnetic Compatibility Amimon Equipment Configuration Falcon RX, Amimon P/N-AMN36254 CFR Title 47, Part 15, Subpart E MET Report: EMC37062B-FCC407 Rev. 1 © 2013, MET Laboratories, Inc. Page iii of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................6 E. Equipment Configuration ....................................................................................................................................6 F. Support Equipment .............................................................................................................................................7 G. Ports and Cabling Information ............................................................................................................................7 H. Mode of Operat…

Text truncated - open the document above for the full version.

Test Setup Photos

Photograph 1. Conducted Emissions, Test Setup Photograph 2. Radiated Emission, Test Setup Photograph 3. Conducted Emissions, Test Setup Photograph 4. Radiated Spurious Emissions, Test Setup

Contact Information

Applicant

Gabi Nocham
[email protected]972-53-2334456Fax: 972-9-956-5467

Technical Contact

Amimon Ltd.Osnat Goren-Peyser
[email protected]+972-9-9629295

2 Maskit St. · Herzlia · Israel

Non-Technical Contact

Amimon Ltd.Moshe Meyassed
[email protected]+972-9-9629298

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.80 GHz46.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power listed is conducted. Modular Approval. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Amimon Ltd.

Wireless Video Transmission Module - FCC ID VQSAMN41012 - Amimon Ltd.
VQSAMN41012

Wireless Video Transmission Module

Jan 27, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Connex TX - FCC ID VQSAMNBZT1 - Amimon Ltd.
VQSAMNBZT1

Connex TX

May 13, 2015

Equipment Class

NII - Unlicensed National Information Infrastructure TX
wireless video receiver module - FCC ID VQSAMNMGIN01 - Amimon Ltd.
VQSAMNMGIN01

wireless video receiver module

Sep 30, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD-SDI wireless transmitter module - FCC ID VQSAMNKHIN1 - Amimon Ltd.
VQSAMNKHIN1

HD-SDI wireless transmitter module

Mar 26, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD-SDI wireless transmitter module - FCC ID VQSAMN35254 - Amimon Ltd.
VQSAMN35254

HD-SDI wireless transmitter module

Mar 11, 2013

Equipment Class

NII - Unlicensed National Information Infrastructure TX