FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Amimon Ltd./
  3. VQSAMNBZT1

VQSAMNBZT1Connex TX

Amimon Ltd.
Connex TX - FCC ID VQSAMNBZT1 - Amimon Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
May 13, 2015
Application Purpose
Original Equipment
Date of Application
May 11, 2015
Equipment Note
Connex TX
Frequency Range
5745.00000000 - 5825.00000000
Company
Amimon Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CONNEX TM User Guide 1 333 CONNEX TM User Guide Version 1.0.81 www.amimon.com Simply Plug-and- Fly! CONNEX TM User Guide 2 About This Guide This user guide describes how to setup and use the CONNEX TM wireless video link in order to transmit video from an aircraft. This user guide consists of the following chapters:  Chapter 1, Introducing CONNEX, page 9, introduces the CONNEX system, its components, its connectors, buttons and cables.  Chapter 2, Setting Up CONNEX, page 18, describes how to setup and connect the CONNEX Air Unit and Ground Unit.  Chapter 3, Using CONNEX, page 28, describes how to get started using the Air Unit and the Ground Unit. This chapter also describes the Ground Unit’s On Screen Display (OSD), how to set up multicasting and how to set up control of the aircraft’s camera gimbal from a gimbal remote control.  Chapter 4, CONNEX Management Application, page 36, describes how to configure and upgrade the CONNEX Air Unit and Ground Unit. For a quick summary of the essential steps for setting up quickly, you may refer to the CONNEX Quick Start Guide. Support and Contacting Information Support: www.AMIMON.com/support When contacting a support representative, make sure to have the Air Unit’s and Ground Unit’s serial number available. This number appears on the label on the bottom of each device. CONNEX TM User Guide 3 Important Notice Copyright © 2015 AMIMON. All rights reserved. All intellectual property rights are owned by AMIMON and protected by applicable copyright laws and international treaty provisions. All software/hardware is furnished under a license agreement. All other trademarks are the property of their respective owners. AMIMON reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to AMIMON’s terms and conditions of sale supplied at the time of order acknowledgment. AMIMON warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with AMIMON’s standard warranty. Testing and other quality control techniques are used to the extent AMIMON deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. AMIMON assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using AMIMON components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. AMIMON does not warrant or represent that any license, either express or implied, is granted under any AMIMON patent right, copyright, mask work right, or other AMIMON intellectual property right relating to any combination, machine, or process in which AMIMON products or services are used. Information published by AMIMON regarding third-party products or services does not constitute a license from AMIMON to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from AMIMON under the patents or other intellectual property of AMIMON. Reproduction of information in AMIMON data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. AMIMON is not responsible or liable for such altered documentation. Resale of AMIMON products or services with statements different from or beyond the parameters stated by AMIMON for that product or service voids all express and any implied warranties for the associated AMIMON product or service and is an unfair and deceptive business practice. AMIMON is not responsible or liable for any such statements. All company and brand products and service names are trademarks or registered trademarks of their respective holders. Revision History Version Date Description 1.0 March 2015 Initial Release Safety Instructions and Maintenance All the instructions in this user guide must be adhered to when operating this equipment. Keep these instructions in a safe and accessible place for future use. Safety Symbols High Voltage Sign: Warns the user of the presence of uninsulated dangerous voltage within the product enclosure, which may be of sufficient magnitude to constitute a risk. General Warning Sign: Warns the user of the presence of important operating and maintenance (servicing) instructions in the product manual. CONNEX TM User Guide 4 Safety Instructions  Do not open the Air Unit or Ground Unit enclosures. There are no user-serviceable parts inside. Refer servicing to qualified service personnel only. The use of controls, adjustments or procedures other than those specified in this user guide may result in exposure to shock and/or electrical or mechanical hazards.  Do not immerse the units in water.  Do not block the air ventilation openings.  Always disconnect a unit’s power by pulling the mains plug.  Only clean with a dry cloth.  Keep powered on units at least 20 cm from your body.  Do not expose the units to moisture or excessive heat. Unit operating temperature is 14–122⁰F (or -10−50⁰C).  Do not operate the device at outdoors when in rainy weather conditions or snow and icing conditions.  Do not operate or store the device in excessive dust conditions, or high humidity conditions.  Unplug the units during lightning storms or when not using them for long periods of time.  Only use the originally ap…

Text truncated - open the document above for the full version.

Users Manual

CONNEX TM User Guide 1 333 CONNEX TM User Guide Version 1.0.81 www.amimon.com Simply Plug-and- Fly! CONNEX TM User Guide 2 About This Guide This user guide describes how to setup and use the CONNEX TM wireless video link in order to transmit video from an aircraft. This user guide consists of the following chapters:  Chapter 1, Introducing CONNEX, page 9, introduces the CONNEX system, its components, its connectors, buttons and cables.  Chapter 2, Setting Up CONNEX, page 18, describes how to setup and connect the CONNEX Air Unit and Ground Unit.  Chapter 3, Using CONNEX, page 28, describes how to get started using the Air Unit and the Ground Unit. This chapter also describes the Ground Unit’s On Screen Display (OSD), how to set up multicasting and how to set up control of the aircraft’s camera gimbal from a gimbal remote control.  Chapter 4, CONNEX Management Application, page 36, describes how to configure and upgrade the CONNEX Air Unit and Ground Unit. For a quick summary of the essential steps for setting up quickly, you may refer to the CONNEX Quick Start Guide. Support and Contacting Information Support: www.AMIMON.com/support When contacting a support representative, make sure to have the Air Unit’s and Ground Unit’s serial number available. This number appears on the label on the bottom of each device. CONNEX TM User Guide 3 Important Notice Copyright © 2015 AMIMON. All rights reserved. All intellectual property rights are owned by AMIMON and protected by applicable copyright laws and international treaty provisions. All software/hardware is furnished under a license agreement. All other trademarks are the property of their respective owners. AMIMON reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to AMIMON’s terms and conditions of sale supplied at the time of order acknowledgment. AMIMON warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with AMIMON’s standard warranty. Testing and other quality control techniques are used to the extent AMIMON deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. AMIMON assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using AMIMON components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. AMIMON does not warrant or represent that any license, either express or implied, is granted under any AMIMON patent right, copyright, mask work right, or other AMIMON intellectual property right relating to any combination, machine, or process in which AMIMON products or services are used. Information published by AMIMON regarding third-party products or services does not constitute a license from AMIMON to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from AMIMON under the patents or other intellectual property of AMIMON. Reproduction of information in AMIMON data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. AMIMON is not responsible or liable for such altered documentation. Resale of AMIMON products or services with statements different from or beyond the parameters stated by AMIMON for that product or service voids all express and any implied warranties for the associated AMIMON product or service and is an unfair and deceptive business practice. AMIMON is not responsible or liable for any such statements. All company and brand products and service names are trademarks or registered trademarks of their respective holders. Revision History Version Date Description 1.0 March 2015 Initial Release Safety Instructions and Maintenance All the instructions in this user guide must be adhered to when operating this equipment. Keep these instructions in a safe and accessible place for future use. Safety Symbols High Voltage Sign: Warns the user of the presence of uninsulated dangerous voltage within the product enclosure, which may be of sufficient magnitude to constitute a risk. General Warning Sign: Warns the user of the presence of important operating and maintenance (servicing) instructions in the product manual. CONNEX TM User Guide 4 Safety Instructions  Do not open the Air Unit or Ground Unit enclosures. There are no user-serviceable parts inside. Refer servicing to qualified service personnel only. The use of controls, adjustments or procedures other than those specified in this user guide may result in exposure to shock and/or electrical or mechanical hazards.  Do not immerse the units in water.  Do not block the air ventilation openings.  Always disconnect a unit’s power by pulling the mains plug.  Only clean with a dry cloth.  Keep powered on units at least 20 cm from your body.  Do not expose the units to moisture or excessive heat. Unit operating temperature is 14–122⁰F (or -10−50⁰C).  Do not operate the device at outdoors when in rainy weather conditions or snow and icing conditions.  Do not operate or store the device in excessive dust conditions, or high humidity conditions.  Unplug the units during lightning storms or when not using them for long periods of time.  Only use the originally ap…

Text truncated - open the document above for the full version.

Cover Letter(s)

30 April, 2015 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: LONG TERM CONFIDENTIALITY REQUEST FOR FCC ID VQSAMNBZT1 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the following items required to be submitted with this application be permanently withheld from public review:  Detailed circuit schematics of EUT --- long term  Block diagram --- long term  Technical/Operational description --- long term  Bill Of Material --- long term The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grand for this application. Please contact me if there is any information you may need. Sincerely, Signature: ______________________ Tal Keren-Zvi VP R&D

Cover Letter(s)

30 April, 2015 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: LONG TERM CONFIDENTIALITY REQUEST FOR FCC ID VQSAMNBZT1 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the following items required to be submitted with this application be permanently withheld from public review:  Detailed circuit schematics of EUT --- long term  Block diagram --- long term  Technical/Operational description --- long term  Bill Of Material --- long term The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grand for this application. Please contact me if there is any information you may need. Sincerely, Signature: ______________________ Tal Keren-Zvi VP R&D

Cover Letter(s)

30 April, 2015 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: SHORT TERM CONFIDENTIALITY REQUEST FOR FCC ID VQSAMNBZT1 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the following items required to be submitted with this application be withheld from public review for 180 day from date of Grant, assumed to be effective till October 2015:  Internal Pictures of device --- Short term The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grand for this application. Please contact me if there is any information you may need. Sincerely, Signature: ______________________ Tal Keren-Zvi VP R&D

External Photos

Confidential 1 www.amimon.com Figure 1: Connex TX - External View - Top Figure 2: Connex TX - External View - Bottom Confidential 2 www.amimon.com Figure 3: Connex TX – External side view #1 Figure 4: Connex TX - External side view #2 Confidential 3 www.amimon.com Figure 5: Connex TX - External view - rear

External Photos

Confidential 1 www.amimon.com Figure 1: Connex TX - External View - Top Figure 2: Connex TX - External View - Bottom Confidential 2 www.amimon.com Figure 3: Connex TX – External side view #1 Figure 4: Connex TX - External side view #2 Confidential 3 www.amimon.com Figure 5: Connex TX - External view - rear

ID Label/Location Info

1 www.amimon.com LABEL 63mm 102mm

Internal Photos

Confidential 1 www.amimon.com Figure 1: Connex TX - Internal View - Top Figure 2: Connex TX - Internal View - Bottom

Internal Photos

Confidential 1 www.amimon.com Figure 1: Connex TX - Internal View - Top Figure 2: Connex TX - Internal View - Bottom

RF Exposure Info

Electromagnetic Compatibility Criteria for Intentional Radiators § 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5150-5250 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4πR2 or R = √PG / 4πS where, S = Power Density P = Power Input to antenna=23.078 dBm (203.142 mW) G = Antenna Gain 2 dBi, 1.58 linear) R = Minimum Distance between User and Antenna (20cm) S = (1.58*203.142 )/(4*3.14*400 ) = 0.063 mW/cm2 Since S < 1 mW/cm2, the minimum distance (R) is 20cm

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5.25-5.35 GHz and 5.47-5.725 GHz; highest conducted power = 22.863dBm (Avg) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (<1 mW/cm 2 ) P = Power Input to antenna (193.33 mW) G = Antenna Gain (1.58numeric) R = Minimum Distance between User and Antenna (20 cm) S = (19.33*158)/ (4*3.14*20 2 ) = 0.061 mW/cm 2 Since S < 1 mW/cm 2 , the minimum distance (R) is 20cm

RF Exposure Info

Electromagnetic Compatibility Criteria for Intentional Radiators § 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5150-5250 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4πR2 or R = √PG / 4πS where, S = Power Density P = Power Input to antenna=23.078 dBm (203.142 mW) G = Antenna Gain 2 dBi, 1.58 linear) R = Minimum Distance between User and Antenna (20cm) S = (1.58*203.142 )/(4*3.14*400 ) = 0.063 mW/cm2 Since S < 1 mW/cm2, the minimum distance (R) is 20cm

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4πR2 or R = √PG / 4πS where, S = Power Density P = Power Input to antenna =22.605 dBm = 182.2 mW G = Antenna Gain 2 dBi (1.58 inear) R = Minimum Distance between User and Antenna (20 cm) S = (182.2*1.58)/(4*3.14*400 ) = 0.06 mW/cm2 Therefore the uncontrolled exposure limit is achieved at 20 cm.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory May 8, 2015 Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, Israel 46733 Dear Arik Israel, Enclosed is the EMC Wireless test report for compliance testing of the Amimon, Connex Air-Unit as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15, Subpart B and ICES- 003, Issue 5, August 2012 for Unintentional Radiators and Part 15.407 and RSS-210, Issue 8, December 2010 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Amimon\EMC85243A-FCC407 RSS-210 UNII 2 Rev. 4) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13301 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMCS37062A-FCC407 © 2015, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the Amimon Connex Air-Unit Tested under the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B & ICES-003 for Unintentional Radiators and Title 47 of the CFR, Part 15.407 & RSS-210 for Intentional Radiators MET Report: EMC85243A-FCC407 RSS-210 UNII 2 Rev. 4 May 8, 2015 Prepared For: Amimon 2 Maskit St. Building D, 2 nd Floor Herzelia, Israel 46733 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility Amimon Equipment Configuration Connex Air-Unit CFR Title 47, Part 15E; RSS-210 MET Report: EMC85243A-FCC407 RSS-210 UNII 2 Rev. 4 © 2015, MET Laboratories, Inc. Page ii of xi Electromagnetic Compatibility Criteria Test Report for the Amimon Connex Air-Unit the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B & ICES-003 for Unintentional Radiators and Title 47 of the CFR, Part 15.407 & RSS-210 for Intentional Radiators Djed Mouada, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules and Industry Canada standards ICES-003, Issue 5, August 2012 and RSS-210, Issue 8, December 2010 under normal use and maintenance. Asad Bajwa, Director Electromagnetic Compatibility Lab Electromagnetic Compatibility Amimon Equipment Configuration Connex Air-Unit CFR Title 47, Part 15E; RSS-210 MET Report: EMC85243A-FCC407 RSS-210 UNII 2 Rev. 4 © 2015, MET Laboratories, Inc. Page iii of xi Report Status Sheet Revision Report Date Reason for Revision  April 6, 2015 Initial Issue. 1 April 13, 2015 Revised to reflect engineer corrections. 2 April 20, 2015 Editorial Corrections. 3 April 30, 2015 Revised to reflect engineer corrections. 4 May 8, 2015 Editorial corrections. Electromagnetic Compatibility Amimon Equipment Configuration Connex Air-Unit CFR Title 47, Part 15E; RSS-210 MET Report: EMC85243A-FCC407 RSS-210 UNII 2 Rev. 4 © 2015, MET Laboratories, Inc. Page iv of xi Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................5 E. Equipment Configuration ....................................................................................................................................7 F. Support Equipment ....…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory May 6, 2015 Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, Israel 46733 Dear Arik Israel, Enclosed is the EMC Wireless test report for compliance testing of the Amimon, Connex Air-Unit as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407, Subpart E (UNII 1) for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Amimon\ EMC85243-FCC407 UNII 1 Rev. 3) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMC85243-FCC407 UNII 1 © 2015, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the Amimon Model Connex Air-Unit Tested under The FCC Certification Rules contained in Title 47 of the CFR, Part 15.407 for Intentional Radiators MET Report: EMC85243-FCC407 UNII 1 Rev. 3 May 6, 2015 Prepared For: Amimon 2 Maskit St. Building D, 2nd Floor Herzelia, Israel 46733 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 Electromagnetic Compatibility Amimon Introduction Connex Air-Unit CFR Title 47, Part 15.407 Subpart E (UNII 1) MET Report: EMC85243-FCC407 UNII 1 Rev. 3 © 2015, MET Laboratories, Inc. Page ii of v Electromagnetic Compatibility Criteria Test Report for the Amimon Model Connex Air-Unit Tested under The FCC Certification Rules contained in Title 47 of the CFR, Part 15.407 for Intentional Radiators Djed Mouada, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this eq…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gabi Nocham
[email protected]972-53-2334456Fax: 972-9-956-5467

Technical Contact

Amimon Ltd.Tal Keren-Zvi
[email protected]972-9-9629298

2 Maskit St. · Herzlia · Israel

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
515E5.75 GHz - 5.83 GHz182.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is aggregate conducted output power. This device has 20 and 40 MHz bandwidth modes. Device is a 2 x 2 MIMO configuration, enabled for 5 GHz band operations as described in this filing. � The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Amimon Ltd.

Wireless Video Transmission Module - FCC ID VQSAMN41012 - Amimon Ltd.
VQSAMN41012

Wireless Video Transmission Module

Jan 27, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
wireless video receiver module - FCC ID VQSAMNMGIN01 - Amimon Ltd.
VQSAMNMGIN01

wireless video receiver module

Sep 30, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD-SDI wireless transmitter module - FCC ID VQSAMNKHIN1 - Amimon Ltd.
VQSAMNKHIN1

HD-SDI wireless transmitter module

Mar 26, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD-SDI wireless receiver module - FCC ID VQSAMN36254 - Amimon Ltd.
VQSAMN36254

HD-SDI wireless receiver module

Mar 12, 2013

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD-SDI wireless transmitter module - FCC ID VQSAMN35254 - Amimon Ltd.
VQSAMN35254

HD-SDI wireless transmitter module

Mar 11, 2013

Equipment Class

NII - Unlicensed National Information Infrastructure TX