Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL T106 REMOTE TRANSMITTER INSTALLATION INSTRUCTION This option controls the engine run time for remote start. SPECIFICATION 1. Power Supply: 6V ( CR2016*2Battery ) 2. Current Consumption: Standby Consumption < 3uA Operating Consumption: <25mA 3. Frequency: 433.92MHz 4. Frequency Tolerance: 300KHz 5. Modulation: OOK (On Off Key / ASK) 6. OSC With SAW Resonator: SAW oscillator plus antenna buffer 7. Hopping code MCU Encoder: Highly security private hopping code by MCU CS616 FCC COMPLIANCE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Remote Start class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. **This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. COMPANY CONTACT Beijing Jia An Electronic Technology Co,.Ltd. Add: No.19 Gu Cheng west street, Shi Jing Shan District, Beijing 100043, CHINA TEL: +86-10-6888 9971 / 6888 9972 / 6888 9973 FAX: +86-10-6888 9905
Beijing Jia An Electronic Technology Co,.Ltd. Tel:+86-10-6888 9971/6888 9972/6888 9973 Fax:+86-10-6888 9905 Add:No.19 Gu Cheng west street,Shi Jing Shan District,Beijing 100043,CHINA Revision: 080408A Request of Confidentiality Oct.20,2010 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: VVJ-T106S434 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Parts List Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Best Regards Oct.20,2010 ------------------------------------------------------------------- Name Helen Ban Title General Manager Tel.: +86 10-68889971 Fax: +86 10-68889905 Mail: [email protected]
Beijing Jia An Electronic Technology Co,.Ltd. Tel:+86-10-6888 9971/6888 9972/6888 9973 Fax:+86-10-6888 9905 Add:No.19 Gu Cheng west street,Shi Jing Shan District,Beijing 100043,CHINA Revision: 080314A Power of Attorney Oct.20,2010 To whom it may concern: We, the undersigned, Beijing Jia An Electronic Technology Co,.Ltd., hereby authorize Bureau Veritas (Hong Kong) Limited to act on our behalf in all matters relating to all processes required in the FCC part 15 approval and any communication needed with the national authority. Any and all acts carried out by Bureau Veritas (Hong Kong) Limited on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please do not hesitate to contact us. Thank you! Sincerely yours, Oct.20,2010 ------------------------------------------------------------------- Name Helen Ban Title General Manager Tel.: +86 10-68889971 Fax: +86 10-68889905 Mail: [email protected]
External Photo Front View of the product Rear View of the product Battery Cover Battery Compartment
Internal Photo Inner View of the Product Inner View of the Product Inner Circuit Top View Inner Circuit Bottom View Antenna
TEST REPORT No.: (5210)174-0373 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Page 2 of 18 Location of the test laboratory Radiated and Conducted emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2003. An Open Area Test Site and Full Anechoic Chamber (FCC Listed Site, Registration No. 642151) are set up for investigation and located at : BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE No. 2106-2107, 21/F., Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong List of measuring equipment Radiated Emission EQUIPMENT MANUFACTURER MODEL NO. SERIAL NO. CALIBRATION DUE EMI TEST RECEIVER R&S ESCI 100379 06-SEP-2011 LOOP ANTENNA ETS-LINDGREN 6502 00102266 17-MAY-2011 BILOG ANTENNA SCHAFFNER CBL6112D 25229 02-AUG-2011 OPEN AREA TEST SITE BVCPS N/A N/A 05-JULY-2011 ANECHOIC CHAMBER ALBATROSS M-CDC 80374004499B 06-JULY-2011 COAXIAL CABLE SUHNER N/A N/A 07-DEC-2010 Remarks:- N/A : Not Applicable or Not Available The measurement instrumentation uncertainty would be taking into consideration on each of the test result TEST REPORT No.: (5210)174-0373 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Page 3 of 18 Equipment Under Test [EUT] Description of Sample: Model Name: Remote Transmitter Model Number: T106 Rating: 6Vd.c. (“CR2016” size battery x 2) Remark: -- Description of EUT Operation: The Equipment Under Test (EUT) is a BEIJING JIA AN ELECTRONIC TECHNOLOGY CO., LTD. of RF Remote Transmitter. It is a 1-button transmitter and operating at 433.87MHz. The EUT transmit while button is being pressed. Modulation by IC, and type is OOK modulation. The transmitter has different control: 1. Remote start button – Transmission on (push-to-operate) Antenna Requirement (Section 15.203) The EUT is use of a permanently antenna. It is soldered on the PCB. The antenna consists of 18mm long metal spring antenna. The antenna is not replaceable or user serviceable. The requirements of S15.203 are met. There are no deviations or exceptions to the specifications. Photo of Antenna TEST REPORT No.: (5210)174-0373 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Page 4 of 18 Test Results Radiated Emissions (Fundamental) Test Requirement: FCC Part 15 Section 15.231(a) Test Method: ANSI C63.4 Test Date(s): 2010-09-20 Temperature: 25.0 o C Humi…
Text truncated - open the document above for the full version.
Test Set Up Photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.87 MHz - 433.87 MHz | - |

Transceiver Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BLE module
Equipment Class
DTS - Digital Transmission SystemTransmitter
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterWifi Module
Equipment Class
DTS - Digital Transmission System
Smart Key Finder
Equipment Class
DTS - Digital Transmission System