VVJ-T306R340Remote Controller

Beijing Jia An Electronic Technology Co,. Ltd
Remote Controller - FCC ID VVJ-T306R340 - Beijing Jia An Electronic Technology Co,. Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 27, 2007
Application Purpose
Original Equipment
Date of Application
Dec 27, 2007
Equipment Note
Remote Controller
Frequency Range
340.00000000 - 340.00000000
Company
Beijing Jia An Electronic Technology Co,. Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HAND HELD DIGITAL TRANSMITTER 1 Description The T306 Series Transmitter is ideal for the opening, closing the garage door and control the winch of hoist machine. The Transmitter is available in hand-held and transmits a unique code each time the switch is closed to provide a secure control. The transmitter is powered by a 12-volt battery and a blue indicator light when the transmitter is activated. 2 Specifications DESCRIPTION SPECIFICATION FREQUENCY 340MHz EMITTED RADIO POWER <8dBm POWER CONSUMPTION Max 12mA OPERATING TEMPERATURE -10 ̊C~+55 ̊C DIMENSIONS 75mmx38mmx13mm CERTIFICATION FCC 3 Battery Replacement 1.Remove screw from back of transmitter. 2.Separate housing and install a fresh 12-Volt/23A ALKALINE battery making sure to observe properly polarity. 3.Reassemble housing and replace screw. CANSEC T306 / T206 TRANSMITTERS RF MODULE & SECURIT Y PRODUCTS USER’S GUIDE T306 T206 T306 T206 1 4 FCC Compliance The Digital Transmitter complies with part 15 of the FCC rules. Operation is subject to the following two condition: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inference in a residential installation.This equipment generates, use and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on , the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. --The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that change or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device is tested and found compliance with the FCC Part 15.231 for the periodic operation. In order to maintain the compliance, and under the definition of periodic operation, NO continuous operation is allowed. User MUST take caution of the operation NOT MORE THAN 5 SECOND, otherwise could void the user's authority to operate this product and must take responsible for this violation. changes or modifications not expressly approved by Beijing Jia An Electronic Technology Co,.Ltd. fo r compliance could void the user's authority to operate the equipment. 5 Company Contact Beijing Jia An Electronic Technology Co,.Ltd. Add: No.19 Gu Cheng west street, Shi Jing Shan District, Beijing 100043, CHINA TEL: +86-10-6888 9971 / 6888 9972 / 6888 9973 FAX: +86-10-6888 9905

Cover Letter(s)

December 19,2007 Difference Declaration We,Beijing Jia An Electonic Technology Co,.Ltd., hereby would like to confirm that the alternate models: T206 is identical to the basic model T306, except for the number of activation buttons (2 and 3).The T206 is a two button device,the T306 is a three button device.We declare that the circuit diagrams of the two models are accordant. Sincerely yours, Helen Ban CANSEC RF MODULE & SECURITY PRODUCTS Beijing Jia An Electronic Technology Co,.Ltd. TEL: +86-10-6888 9971 / 6888 9972 / 6888 9973 FAX. +86-10-6888 9905 Add.: No.19 Gu Chen g west street, Shi Jing Shan District, Beijing 100043, CHINA

External Photos

T306 External Photo T206 External Photo

ID Label/Location Info

T306 FCC LABEL: Prod.: Remote controller FCC ID: VVJ-T306R340 Model #: T306,T206 21mm 7mm ACTUAL SIZE OF LABEL LABEL LOCATION

Internal Photos

T306 Internal Photo T206 Internal Photo

Test Report

TEST REPORT N°: BJA-07-DE-H1543-ETZFB BUREAU VERITAS HONG KONG LIMITED – KWAI CHUNG OFFICE LCIE ELECTRICAL DIVISION Unit 1611, 1614 & 1615, 16/F, VANTA INDUSTRIAL CENTRE 21-33, TAI LIN PAI ROAD, KWAI CHUNG, N.T. HONG KONG Tel: +852 2494 4676 Fax: +852 2426 0613 Email: [email protected] This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://cps.bureauveritas.com and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents . Page 1 of 18 TEST REPORT To: BEIJING JIA AN ELECTRONIC TECHNOLOGY CO., LTD To: - Attn: Helen BAN Attn: - Address: No.19, Gu Cheng West Street, Shi Jing Shan District, Beijing 100043, China Address: - Fax: 86 10-68889905 Fax: - E-mail: [email protected] E-mail: - This document includes: 18 pages Factory name: Unidentified Offer: BJA07DE03-01ETZHFP Location: Unidentified Sample No: -- Start date: December 03, 2007 Finish date: December 10, 2007 Test Requested: FCC Part 15.231 Certification Procedure Test Method: 47 CFR Part 15 (10-1-05 Edition) ANSI C63.4 – 2003 Re-testing: NONE REMOTE CONTROLER MODEL T206 & T306 (FCC ID: VVJ-T306R340) Test Result: SEE PAGE 2 TO 4 The results given in this report are related to the tested specimen of the described electrical apparatus. (T206 & T306 are pre-scanned and found that T306 is the worst case, this report is based on the result of T306) CONCLUSION: The submitted sample was found to comply with requirement of FCC Part 15.231 Subpart C. Authorized Signature: Director of Operation: Patrick Wong Date: December 15, 2007 TEST REPORT N°: BJA-07-DE-H1543-ETZFB BUREAU VERITAS HONG KONG LIMITED – KWAI CHUNG OFFICE LCIE ELECTRICAL DIVISION Unit 1611, 1614 & 1615, 16/F, VANTA INDUSTRIAL CENTRE 21-33, TAI LIN PAI ROAD, KWAI CHUNG, N.T. HONG KONG Tel: +852 2494 4676 Fax: +852 2426 0613 Email: [email protected] This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://cps.bureauveritas.com and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents . Page 2 of 18 Location of the test site Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2003 (FCC Registration No.: 597719). A Semi-Anechoic Chamber Testing Site is set up for investigation and located at : CGEL (a.k.a. GUANGDONG ELECTRONIC & ELECTRICAL PRODUCTS INSPECTION AND SUPERVISION INSTITUTE) No.45 South St., Shayongnan Village, Sanyuanli Guangzhou City, Guangdong Province, China 51400 Conducted emissions measurements are investigated and also taken pursuant to the procedures of ANSI C63.4 – 2003 (FCC Registration No.: 597719). A shielded room is located at : CGEL (a.k.a. GUANGDONG ELECTRONIC & ELECTRICAL PRODUCTS INSPECTION AND SUPERVISION INSTITUTE) No.45 South St., Shayongnan Village, Sanyuanli Guangzhou City, Guangdong Province, China 51400 The performed tests have been conducted by the above EMC testing locations and under supervision of a BVLCIE’s engineer. List of measuring equipment For test frequency range: 30MHz to 1000MHz Equipment Manufacturer Model No. Serial No. Cal. Due date EMI Receiver R&S ESIB7 100192 2008/03/29 Antenna R&S HL-562 100172 2008/08/14 RF Cable R&S / / 2008/08/14 RF Cable R&S / / 2008/08/14 RF Cable R&S / / 2008/08/14 3m anechoic chamber ETS RFD-F-100 / 2008/05/24 Shielding Room ETS RFD-100 / 2008/05/24 TEST REPORT N°: BJA-07-DE-H1543-ETZFB BUREAU VERITAS HONG KONG LIMITED – KWAI CHUNG OFFICE LCIE ELECTRICAL DIVISION Unit 1611, 1614 & 1615, 16/F, VANTA INDUSTRIAL CENTRE 21-33, TAI LIN PAI ROAD, KWAI CHUNG, N.T. HONG KONG Tel: +852 2494 4676 Fax: +852 2426 0613 Email: [email protected] This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at htt…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST REPORT N°: BJA-07-DE-H1543-ETZFB BUREAU VERITAS HONG KONG LIMITED – KWAI CHUNG OFFICE LCIE ELECTRICAL DIVISION Unit 1611, 1614 & 1615, 16/F, VANTA INDUSTRIAL CENTRE 21-33, TAI LIN PAI ROAD, KWAI CHUNG, N.T. HONG KONG Tel: +852 2494 4676 Fax: +852 2426 0613 Email: [email protected] This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://cps.bureauveritas.com and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents . Page 19 of 19 Appendix I Photographs of the test setup for the highest emission ***** End of Report *****

Contact Information

Applicant

Helen BAN(General Manager)
[email protected]+86-10-68889971Fax: +86-10-68889905

Test Firm

CGELYAO Dao
[email protected]862036378205Fax: 862036377049

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231340 MHz - 340 MHz-
Confidentiality
Long Term

Other Applications from Beijing Jia An Electronic Technology Co,. Ltd

Transceiver Module - FCC ID VVJ-LR68-NA-C-915 - Beijing Jia An Electronic Technology Co,. Ltd
VVJ-LR68-NA-C-915

Transceiver Module

Apr 17, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLE module - FCC ID VVJ-AN2640SA-B - Beijing Jia An Electronic Technology Co,. Ltd
VVJ-AN2640SA-B

BLE module

Dec 05, 2015

Equipment Class

DTS - Digital Transmission System
VVJ-T306R434

Transmitter

Aug 30, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
VVJ-TA3200R1D-SA

Wifi Module

May 06, 2015

Equipment Class

DTS - Digital Transmission System
Smart Key Finder - FCC ID VVJ-KF4A - Beijing Jia An Electronic Technology Co,. Ltd
VVJ-KF4A

Smart Key Finder

Sep 29, 2013

Equipment Class

DTS - Digital Transmission System