Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PRODUCT INFORMATION 02-00083-104 Specifications Subject to Change Without Notice. © 2013 Guard RFID Solutions, Inc. Guard RFID Solutions Inc. #140 – 766 Cliveden Place Delta, BC Canada V6M 6C7 Tel: 866.785.7343 Fax: 604.524.4018 guardRFID.com Article Tag – Acive Label AT-4BLF FE A T U R E S: Small, lightweight and only 0.23” (5.95mm) in height Can be applied to most surfaces including on metal Up to 24 months operation Integrated motion and temperature sensors Waterproof and easy-to-clean DE S C R I P T I O N: The AT-4BLF Article Tag is an active RFID tag for tracking, locating, and protecting equipment and other assets that require an ultra-low profile tag with a small footprint. The tag can be placed on almost any surface, including metal surfaces, without significant degradation in performance. The Tag has an integrated motion sensor that can be used to alarm on movement, and which increases the Beacon rate when the tag is in motion. A temperature sensor allows monitoring of ambient temperature between -10º to +60º Celcius. The tags have Ultra-High Frequency (UHF) Beacon message capability for presence- detection and long-range location using GuardRFID’s Tag Readers. They also include a Low Frequency (LF) Receiver that instantly detects entry into critical security zones or other locations of interest that are equipped with GuardRFID’s Tag Exciters. This proximity location technology can instantly secure doors to protect a tagged article from leaving the perimeter, and can support numerous applications where better granularity of tag location is required. GuardRFID’s industry-leading tag communication protocol allows hundreds of tags to be detected simultaneously at security or detection points and enables a high density of tags within the system coverage. The Article Tag can be directly applied to an object using an extremely strong peel-and- stick adhesive label at the back of the tag. SP E C I F I C A T I O N S: AT-4 B L F Part Number 61-10500 Transmit Frequency 433 MHz Receive Frequency 125 KHz Battery Life 12 months nominal based on 60% motion 24 months nominal based on 5% motion Beacon Interval 10 minutes static, 12 seconds while in motion Sensors Motion, Temperature - 14° to 140° F (-10° to +60° C) Dimensions 1.56” x 1.26” x 0.23” (40mm x 32 mm x 5.95mm) Weight 6 gm Operating Temperature -4° F to 122°F (-20°C to 50°C) Tag Replacement Warranty – Prorated up to a maximum term of 12 months This device complies with part 15 of the FCC Rules and with Industry Canada license‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. FCC ID: VZKAT4 IC: 9937A-AT4
#140 – 760 Cliveden Place Delta, BC Canada V3M 6C7 T: 604.998.4018 F: 604.524.4018 www.guardrfid.com December 03, 2013 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: VZKAT4. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematic Theory of Operation Block Diagram AT_Schem.pdf AT_OpDes.pdf AT_BlkDia.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Dalibor Pokrajac VP of Engineering Guard RFID Solutions Inc. 604-282-7584
Article Tag 4 - Photos Guard RFID Solutions Dec 3, 2013 PHOTOS-AT-4BLF - External Photo: Top - External Photo: Bottom
Article Tag 4 - Label Guard RFID Solutions – Confidential Dec 3, 2013 - Label Sample of AT-4BLF - Label Location of AT-4BLF: on Top of EUT
Article Tag 4 - Photos Guard RFID Solutions Dec 3, 2013 - Internal Photo: Top, Battery & Antenna Side - Internal Photo: Bottom, Components Side
TEST REPORT For Guard RFID Solutions Inc. #140 – 766 Cliveden Place Delta, British Columbia V3M 6C7, Canada Date: November 27, 2013 Report No.: 11765-1E Revision No.: 0 Project No.: 11765 Equipment: RFID TAG Model No.: AT-4BLF FCC ID: VZKAT4 IC ID: 9937A-AT4 ONE STOP GLOBAL CERTIFICATION SOLUTIONS 3133-20800 Westminster Hwy, Richmond, BC V6V 2W3, Canada Phone: 604-247-0444 Fax: 604-247-0442 www.labtestcert.com Prepared by: LabTest Certification Inc. Client: Guard RFID Solutions Inc. Date Issued: November 27, 2013 Report No.:11765-1E Project No: 11765 Revision No.: 0 Page 2 of 41 This document shall not be reproduced or utilized in any form or by any means, except in full, without the written approval of LabTest Certification Inc. DCN: 1034, Rev 4 TABLE OF CONTENTS TEST REPORT ................................................................................................................................................ 3 General product information: ............................................................................................................................ 5 Frequencies ...................................................................................................................................................... 6 List of auxiliary and/or support equipment provided by the applicant .............................................................. 6 Software and Firmware .................................................................................................................................... 6 Worst-case configuration and mode of operation during testing ...................................................................... 6 Modifications Required for Compliance............................................................................................................ 6 Test Equipment Verified for function ................................................................................................................ 6 Measurement Uncertainty ................................................................................................................................ 7 Markings ........................................................................................................................................................... 7 Test Summary .................................................................................................................................................. 8 AC Power Line Conducted Emission ............................................................................................................... 9 Test Limits ..................................................................................................................................................... 9 Test Results .................................................................................................................................................. 9 Summary of the operation of RF Transmission .............................................................................................. 10 Test Limits ................................................................................................................................................... 10 Reviewed Results: ...................................................................................................................................... 10 Field Strength of Fundamental ....................................................................................................................... 13 Test Limits ................................................................................................................................................... 13 Test Setup ................................................................................................................................................... 14 Setup Block Diagram .................................................................................................................................. 14 Test Setup in Chamber ............................................................................................................................... 14 Test Results: ............................................................................................................................................... 15 Field Strength of Spurious Emissions ............................................................................................................ 17 Test Limits ................................................................................................................................................... 17 Test Setup ................................................................................................................................................... 18 Test Results: ............................................................................................................................................... 18 Radiated Emission; Intentional Radiators ...................................................................................................... 25 Test Limits ................................................................................................................................................... 25 Test Results: ............................................................................................................................................... 25 The Bandwidth of the emission ...................................................................................................................... 29 Test Limits ................................................................................................................................................... 29 Test Setup ................................................................................................................................................... 29 Test Results: ..........................................................…
Text truncated - open the document above for the full version.
Prepared by: LabTest Certification Inc. Client: Guard RFID Solutions Inc. Date Issued: November 27, 2013 Report No.:11765-1E Project No: 11765 Revision No.: 0 Page 33 of 41 This document shall not be reproduced or utilized in any form or by any means, except in full, without the written approval of LabTest Certification Inc. DCN: 1034, Rev 4 APPENDIX C: Test setup photos - Test configuration for Field Strength measurement Prepared by: LabTest Certification Inc. Client: Guard RFID Solutions Inc. Date Issued: November 27, 2013 Report No.:11765-1E Project No: 11765 Revision No.: 0 Page 34 of 41 This document shall not be reproduced or utilized in any form or by any means, except in full, without the written approval of LabTest Certification Inc. DCN: 1034, Rev 4 - Test configuration for Harmonic measurement Prepared by: LabTest Certification Inc. Client: Guard RFID Solutions Inc. Date Issued: November 27, 2013 Report No.:11765-1E Project No: 11765 Revision No.: 0 Page 35 of 41 This document shall not be reproduced or utilized in any form or by any means, except in full, without the written approval of LabTest Certification Inc. DCN: 1034, Rev 4 - Test configuration for Unintentional measurement below 30MHz Prepared by: LabTest Certification Inc. Client: Guard RFID Solutions Inc. Date Issued: November 27, 2013 Report No.:11765-1E Project No: 11765 Revision No.: 0 Page 36 of 41 This document shall not be reproduced or utilized in any form or by any means, except in full, without the written approval of LabTest Certification Inc. DCN: 1034, Rev 4 - Set-up for Orthogonal X - Set-up for Orthogonal Y - Set-up for Orthogonal Z
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Guard RFID WiFi staff/employee tag
Equipment Class
DTS - Digital Transmission System
ACTIVE RFID TAG USED FOR LOCATION AND PERIMETER PROTECTION OF PEOPLE
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
GENERATOR OF LOW FREQUENCY FILED USED FOR DETECTION OF ACTIVE TAGS AT THE PORTAL
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
ACTIVE RFID TAG USED FOR LOCATION AND PERIMETER PROTECTION OF PEOPLE AND ASSETS
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
ACTIVE RFID TAG USED FOR LOCATION AND PERIMETER PROTECTION OF ASSETS
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver