FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RONDISH CO. LTD/
  3. WNG-NEC-05M

WNG-NEC-05MWireless Handset

RONDISH CO. LTD
Wireless Handset - FCC ID WNG-NEC-05M - RONDISH CO. LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 01, 2023
Application Purpose
Original Equipment
Date of Application
May 01, 2023
Equipment Note
Wireless Handset
Frequency Range
433.92000000 - 433.92000000
Company
RONDISH CO. LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Designs in Security / Healthcare / Communication Rondish Company Limited Unit G & H, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong Tel.: (852) 25431955 Fax: (852) 25417411 DATE: 2-Mar-2023 RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com Wireless Handset (NEC-05M): RF Technical Operation NEC-05M is a wireless handset for emergency use to work with a monitor or a receiver or a system. It uses the OOK modulation with a carrier frequency at 433.92MHz for signalling. It simply operates as below: 1. Pressing the “CALL” button to send a RF signal to a receiver or a monitor to make an alarm for normal help. 2. When the normal call is served, a “Cancel” RF signal can be used to reset the alarm by pressing the “R” button. 3. When the emergency call is activated by sliding the side switch down, an emergency signal is sent to the receiver or the monitor. 4. By pushing the slide switch up, it sends a reset signal. Designs in Security / Healthcare / Communication Rondish Company Limited Unit G & H, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong Tel.: (852) 25431955 Fax: (852) 25417411 DATE: 31-Mar-2023 RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.

Attestation Statements

Designs in Security / Healthcare / Communication RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com Covered Equipment Certification Attestation Letter 3/31/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: WNG-NEC-05M Rondish Company Limited (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Rondish Company Limited (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Terrence Ying Title: Senior QA Engineer Company Name: Rondish Company Limited Date: 3/31/2023

Cover Letter(s)

Designs in Security / Healthcare / Communication RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com DATE : 31-Mar-2023 Nemko North America, Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint Sunny Lu from Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China, (Name and address,person) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America,Inc, still resides with Rondish Company Limited, Unit G & H, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong ( applicant name and address) Agency agreement expiration date: 31-Dec-2023 By: Terrence Ying Signature Printed Title: Senior QA Engineer On behalf of : (Rondish Company Ltd) Telephone: +852-25431955

Cover Letter(s)

Designs in Security / Healthcare / Communication March 31, 2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: WNG-NEC-05M Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☐Permanent ☒Short Term Parts List & Placement/BOM ☐Permanent ☐Short Term Tune-Up Procedure ☐ Permanent ☐Short Term Schematic Diagrams ☒ Permanent ☐Short Term Test Setup Photos ------------------ ☒Short Term User’s Manual ☐ Permanent* ☒Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Terrence Ying Title: Senior QA Engineer Company Name: Rondish Company Limited RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com

External Photos

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 23 of 30 12. PHOTOGRAPH OF EUT Figure 1 General Appearance of the EUT Figure 2 General Appearance of the EUT AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 24 of 30 Figure 3 General Appearance of the EUT Figure 4 General Appearance of the EUT AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 25 of 30 Figure 5 General Appearance of the EUT Figure 6 General Appearance of the EUT AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 26 of 30 Figure 7 General Appearance of the EUT Figure 8 General Appearance of the EUT

ID Label/Location Info

Customer: Date: Model: Type: Art Ver.: Size: Rondish 2022-11-28 NEC-05M Lable Art_NEC-05M_LB (20221128) 35 x 50mm Wireless Handset Model No.: NEC-05M FCC ID: WNG-NEC-05M This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made In China Manufactured by Rondish Company Ltd Unit G & GH, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong www.rondish.com Rondish 50mm 35mm Wireless Handset Model No.: NEC-05M FCC ID: WNG-NEC-05M This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made In China Manufactured by Rondish Company Ltd Unit G & GH, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong www.rondish.com Rondish Label Location

Internal Photos

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 27 of 30 Figure 9 Inside of the EUT Figure 10 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 28 of 30 Figure 11 Inside of the EUT Figure 12 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 29 of 30 Figure 13 Inside of the EUT Figure 14 Inside of the EUT Antenna AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 30 of 30 Figure 15 Inside of the EUT Figure 16 Inside of the EUT THE END

Operational Description

Designs in Security / Healthcare / Communication Rondish Company Limited Unit G & H, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong Tel.: (852) 25431955 Fax: (852) 25417411 DATE: 2-Mar-2023 RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com Wireless Handset (NEC-05M): RF Technical Operation NEC-05M is a wireless handset for emergency use to work with a monitor or a receiver or a system. It uses the OOK modulation with a carrier frequency at 433.92MHz for signalling. It simply operates as below: 1. Pressing the “CALL” button to send a RF signal to a receiver or a monitor to make an alarm for normal help. 2. When the normal call is served, a “Cancel” RF signal can be used to reset the alarm by pressing the “R” button. 3. When the emergency call is activated by sliding the side switch down, an emergency signal is sent to the receiver or the monitor. 4. By pushing the slide switch up, it sends a reset signal. Designs in Security / Healthcare / Communication Rondish Company Limited Unit G & H, 4/F, Block 1, Kwai Tak Ind. Ctr, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong Tel.: (852) 25431955 Fax: (852) 25417411 DATE: 31-Mar-2023 RONDISH COMPANY LIMITED Unit G/H, 4/F, Block 1, Kwai Tak Industrial Centre, 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong. Tel.: (852) 2541 6685 Fax: (852) 2541 7411 Email: [email protected] Website: www.rondish.com Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.

RF Exposure Info

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 1 of 30 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of RONDISH CO. LTD Wireless Handset NEC-05M FCC ID: WNG-NEC-05M Prepared for : RONDISH CO. LTD UNIT G&H, 4/F, Block 1, KWAI TAKIND, CTR, 15-33 K Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F23053 Date of Test : Mar.08~10, 2023 Date of Report : Apr.15, 2023 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 2 of 30 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 4 1.1. Description of Standards and Results ...................................................................................... 4 2. GENERAL INFORMATION ............................................................................................ 5 2.1. Description of Device (EUT) .................................................................................................. 5 2.1. EUT Configuration and operation conditions for test ............................................................. 6 2.2. Test Facility ............................................................................................................................. 6 2.3. Measurement Uncertainty (95% confidence levels, k=2) ....................................................... 6 3. POWER LINE CONDUCTED EMISSION TEST .......................................................... 7 4. RADIATED EMISSION TEST ......................................................................................... 8 4.1. Test Equipments ...................................................................................................................... 8 4.2. Block Diagram of Test Setup .................................................................................................. 9 4.3. Radiated Emission Limit ....................................................................................................... 10 4.4. EUT Configuration on Test ................................................................................................... 10 4.5. Operating Condition of EUT ................................................................................................. 10 4.6. Test Procedure ....................................................................................................................... 10 4.7. Radiated Emission Test Results ............................................................................................ 10 5. STOP TRANSMITTING TIME TEST ........................................................................... 15 5.1. Test Equipments .................................................................................................................... 15 5.2. Limit ...................................................................................................................................... 15 5.3. Test Results ........................................................................................................................... 15 6. CEASE TIME AFTER ACTIVATION TEST ............................................................... 16 6.1. Test Equipments .................................................................................................................... 16 6.2. Limit ...................................................................................................................................... 16 6.3. Test Result ............................................................................................................................. 16 7. 20 DB BANDWIDTH TEST ............................................................................................ 17 7.1. Test Equipments .................................................................................................................... 17 7.2. Limit ...................................................................................................................................... 17 The bandwidth of the emission shall be no wider than 0.25% of the center frequency................... 17 7.3. Test Results ........................................................................................................................... 17 8. ANTENNA REQUIREMENT ......................................................................................... 18 9. RADIO FRREQUENCY EXPOSURE COMPLIANCE ............................................... 19 10. DEVIATION TO TEST SPECIFICATIONS ................................................................. 20 11. PHOTOGRAPH OF TEST .............................................................................................. 21 11.1. Photos of Radiated Emission Test ......................................................................................... 21 12. PHOTOGRAPH OF EUT ................................................................................................ 23 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 3 of 30 TEST REPORT CERTIFICATION Applicant : RONDISH CO. LTD Manufacturer : RONDISH CO. LTD Product : Wireless Handset FCC ID : WNG-NEC-05M (A)Model No. : NEC-05M (B)Power Supply : DC 3V (C)Test Voltage : DC 3V Tested for comply with: FCC CFR47 Part 15 Subpart C Test procedure used: ANSI C63.10: 2020 The device described above is tested by udix Technology (Shenzhen) Co., Ltd. to confirm comply with all the FCC Part 15 Subpart C requirements. The test results are contained in this test report and udix Technology (Shenzhen) Co., Ltd. is assumed full responsibility for the accuracy and completeness of these tests. This report contains data that are not co…

Text truncated - open the document above for the full version.

Test Report

Manufacture: Shenzhen Dafei Electronic Technology Co., Ltd Address: 101, Building A, Xiangdeyi Industrial Park, No. 180 Changxing Road, Zhangkengjing Community, Guanhu Street, Longhua District, Shenzhen Model: NEC-05M NEC-05M PCB Antenna Peak Gain: 0dBi Antenna dimension: 57mm x 0.7mm x 1oz copper Antenna

Test Report

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 1 of 30 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Rondish Company Limited Wireless Handset NEC-05M FCC ID: WNG-NEC-05M Prepared for : Rondish Company Limited Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai Tak St., Kwai Chung, N.T., Hong Kong Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F23053 Date of Test : Mar.08~10, 2023 Date of Report : Apr.15, 2023 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 2 of 30 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 4 1.1. Description of Standards and Results ...................................................................................... 4 2. GENERAL INFORMATION ............................................................................................ 5 2.1. Description of Device (EUT) .................................................................................................. 5 2.1. EUT Configuration and operation conditions for test ............................................................. 6 2.2. Test Facility ............................................................................................................................. 6 2.3. Measurement Uncertainty (95% confidence levels, k=2) ....................................................... 6 3. POWER LINE CONDUCTED EMISSION TEST .......................................................... 7 4. RADIATED EMISSION TEST ......................................................................................... 8 4.1. Test Equipments ...................................................................................................................... 8 4.2. Block Diagram of Test Setup .................................................................................................. 9 4.3. Radiated Emission Limit ....................................................................................................... 10 4.4. EUT Configuration on Test ................................................................................................... 10 4.5. Operating Condition of EUT ................................................................................................. 10 4.6. Test Procedure ....................................................................................................................... 10 4.7. Radiated Emission Test Results ............................................................................................ 10 5. STOP TRANSMITTING TIME TEST ........................................................................... 15 5.1. Test Equipments .................................................................................................................... 15 5.2. Limit ...................................................................................................................................... 15 5.3. Test Results ........................................................................................................................... 15 6. CEASE TIME AFTER ACTIVATION TEST ............................................................... 16 6.1. Test Equipments .................................................................................................................... 16 6.2. Limit ...................................................................................................................................... 16 6.3. Test Result ............................................................................................................................. 16 7. 20 DB BANDWIDTH TEST ............................................................................................ 17 7.1. Test Equipments .................................................................................................................... 17 7.2. Limit ...................................................................................................................................... 17 The bandwidth of the emission shall be no wider than 0.25% of the center frequency................... 17 7.3. Test Results ........................................................................................................................... 17 8. ANTENNA REQUIREMENT ......................................................................................... 18 9. RADIO FRREQUENCY EXPOSURE COMPLIANCE ............................................... 19 10. DEVIATION TO TEST SPECIFICATIONS ................................................................. 20 11. PHOTOGRAPH OF TEST .............................................................................................. 21 11.1. Photos of Radiated Emission Test ......................................................................................... 21 12. PHOTOGRAPH OF EUT ................................................................................................ 23 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 3 of 30 TEST REPORT CERTIFICATION Applicant : Rondish Company Limited Manufacturer : Rondish Company Limited Product : Wireless Handset FCC ID : WNG-NEC-05M (A)Model No. : NEC-05M (B)Power Supply : DC 3V (C)Test Voltage : DC 3V Tested for comply with: FCC CFR47 Part 15 Subpart C Test procedure used: ANSI C63.10: 2020 The device described above is tested by udix Technology (Shenzhen) Co., Ltd. to confirm comply with all the FCC Part 15 Subpart C requirements. The test results are contained in this test report and udix Technology (Shenzhen) Co., Ltd. is assumed full responsibility for the accuracy a…

Text truncated - open the document above for the full version.

Test Setup Photos

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 21 of 30 11. PHOTOGRAPH OF TEST 11.1.Photos of Radiated Emission Test 30-1000MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:WNG-NEC-05M Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F23053 page 22 of 30 Above 1000MHz

Contact Information

Applicant

TERRENCE YING(SENIOR PROJECT ENGINEER)
[email protected]852-25431955Fax: 852-25417411

Test Firm

AUDIX Technology (Shenzhen) Co., Ltd.Amelia Peng
[email protected]86-755266394957Fax: 86-75526632877

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from RONDISH CO. LTD

Pad Transmitter - FCC ID WNG-PT-11 - RONDISH CO. LTD
WNG-PT-11

Pad Transmitter

Oct 30, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Indication Light, Wireless Extender - FCC ID WNG-ILB-21-FSK - RONDISH CO. LTD
WNG-ILB-21-FSK

Wireless Indication Light, Wireless Extender

Jan 29, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Receiver Dongle - FCC ID WNG-DON-30-FSK - RONDISH CO. LTD
WNG-DON-30-FSK

Receiver Dongle

Jan 29, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Door Alert Strip Receiver - FCC ID WNG-DMS-21 - RONDISH CO. LTD
WNG-DMS-21

Door Alert Strip Receiver

Nov 22, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Handset - FCC ID WNG-NEC-05 - RONDISH CO. LTD
WNG-NEC-05

Wireless Handset

Mar 20, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter