Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RP-600 PG+ Repeater The reference to RP-600 PG+ throughout this document includes the model RP-600 P9M0. EN To download the full manual for this product, go to https://www.visonic.com/download-center or scan the QR code. ES Para descargar el manual completo de este producto, vaya a https://www.visonic.com/download-center o escanee el código QR. FR Pour télécharger les manuels complets,veuillez visiter https://www.visonic.com/download-center ou scanner le code QR. FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To comply with FCC Section 1.1310 for human exposure to radio frequency electromagnetic fields, implement the following instruction: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Product Certification RP-600 PG+ complies with the following standards: RP-600 P9M0 FCC (915 MHz): 47CFR part 15.427 Safety Instructions Read the safety information before you install the equipment. The repeater shall be installed and used within an environment that provides the pollution degree max 2 and over voltages category II in non-hazardous locations, indoor only. The equipment is designed to be installed by SERVICE PERSONS only; (SERVICE PERSON is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). The repeater is to be installed in an indoor dry location. Exposure to weather or corrosive conditions may damage the unit. The RP-600 PG+ is direct plug in powered from the mains. The enclosure must be secured to the building structure before operation. Use only the power supply supplied with this equipment or defined by manufacturer. Use of unauthorized power supplies may damage the repeater! Disclaimer: Please be advised that the RP-600 PG+ may be sold without a power supply due to some standardization rules. To allow for the proper functioning of the product, you must purchase a power supply with the following specifications: Input: 100 to 240 AC, Output: 6V/1A DC The AC socket or outlet powering the equipment should be easily accessible. WARNING: This equipment has no mains on/off switch. The plug of the direct plug-in power supply is intended to serve as the disconnecting device if the equipment must be quickly disconnected. It is imperative that access to the mains plug and associated mains socket/outlet, is never obstructed. Ensure that cables are positioned so that accidents cannot occur. Connected cables must not be subject to excessive mechanical strain. Backup battery type is Q-LITE. CAUTION: Risk of explosion if the battery is replaced with an incorrect type. Dispose of used battery according to the manufacturer's instructions. WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer. This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other reason, according to the Manufacturers discretion, such as improper installation, failure to follow recommended installation and operational instructions, neglect, wilful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not covered by this Warranty. There is absolutely no warranty on software, and all software products are sold as a user license under the terms of the software license agreement included with such Product. The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the Product will prevent any death and/or personal injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product, properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur. Conditions to Void Warranty: This warranty applies only to defects in parts and workma…
Text truncated - open the document above for the full version.
Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 02-05-2023 Certification Application Attestation Statements Visonic Ltd. 13 Zarhin street 4366241 Raanana, Israel Subject: FCC ID: WP3RP600PGP To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Visonic Ltd. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Visonic Ltd. (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 01-May-23 City: Tel Aviv Name (2) : Zuri Rubin Function: Certification Manager Telephone number: +972 3645 6832 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_02 02-05-2023 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : __-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : __-02-2023
Visonic Ltd. 13 Zarhin Street P.O.Box 4228 Raanana, 4366241, Israel Tele: +972 3 645 6789 Fax: +972 3 645 6788 www.visonic.com U .S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands AT TENTION: FCC Certification – Section 2.911(d)(7) Information D esignated U.S. Agent Company name: Qolsys Inc. FRN: 0022572226 Contact person name: Mark Skeen Street address: 1919 S. Bascom Ave. ZIP/City/State Campbell, CA 95008, USA Telephone number: Email address: [email protected] Signature: Date: 2023 0316 Thi s letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The A pplicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. A pplicant Company name: Visonic Ltd. Grantee Code: WP3 Contact person name: Zuri Rubin Street address: 13 Zarhin street ZIP/City/State 4366241, Raanana, Israel Telephone number: +972 3 6456832 Email address: [email protected] Signature: Date: 20.3.2023 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvdM 02 1 15-05-2023 Added FRN to Agent details RvdM Issued/modified by : Richard van der Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : __-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : __-02-2023 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM Issued/modified by : Richard van der Meer Function : Certification assessor Revision 01 Date :07-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 09-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 09-02-2023
May 09, 2023 Telefication B.V. Attn: Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Application for certification for a Wireless Repeater for PowerG Communications, FCC ID: WP3RP600PGP Dear Gentlemen, Please find attached our application for certification for a Wireless Repeater for PowerG Communications, FCC ID: WP3RP600PGP, prepared in accordance with FCC Rules, parts 2 and 15, section 15.247(FHSS). The product testing and this application for certification were performed by Hermon Laboratories, which is recognized and accredited by FCC, Test Firm Registration Number is 927748, Designation Number is IL1001. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. We hope this application satisfies your requirements. Please send an invoice to Hermon Labs. Dan Nita, Approvals Manager Tyco Safety Products Canada Ltd.
Johnson Controls 24 Habarzel Street P.O.Box 22020 Tel-Aviv 69710, Israel Tele: +972 3 645 6789 Fax: +972 3 645 6788 1 Declaration Letter FCC ID: WP3RP600PGP Product Name: RP-600 P9M0 A Part 15 repeater is a device that is intended to re-radiate an input signal by demodulating, re-shaping or re-timing the signal; and/or perform a combination of any of these functions, on a radio frequency input signal. A Part 15 repeater is a device intended for re-transmission of information that ensures the elimination of re- transmissions of any input noise or any other unwanted signals. These devices can be approved under the following conditions: 1. A Part 15 repeater must be certified with a unique FCC ID, and used with transmitters that operate compliant to a specific Part 15 rule, or set of rules (as a composite device). The repeater must only re-transmit signals that are uniquely identified as originating from a transmitter, or set of transmitters, with which the repeater is authorized to operate Answer: This product is certified with FCC ID: WP3RP600PGP Operated with Transmitter/products based on unique PG2 protocol. The repeater re-transmits signals that are uniquely identified as originating from a transmitter, or set of transmitters, with which the repeater is authorized to operate 2. The Grant of Equipment Authorization for a Part 15 repeater must list the FCC IDs for all transmitters with which the repeater is authorized to operate. Additional transmitters can be added through a Class II permissive change, provided that test data is submitted for each new transmitter. A Grant of Authorization will then be issued approving the additional transmitter(s) with the listed FCC IDs. Answer: The Repeater is authorization to operate with PG2 device that submitted to FCC and have FCC ID 3. Part 15 repeaters designed to be inter- operable with open source or industry standard transmitters, must provide test data demonstrating compliance with a certified transmitter. The Grant of Equipment Authorization must note the FCC ID of the transmitter used for the inter-operable test. Answer: This product is not designed to operate with open-source industry standard transmitter Johnson Controls 24 Habarzel Street P.O.Box 22020 Tel-Aviv 69710, Israel Tele: +972 3 645 6789 Fax: +972 3 645 6788 2 4. A Part 15 repeater must comply with all requirements in the rule part under which the Grant of Equipment Authorization is requested, including technical, operational and all other limitations set forth in the applicable rules, regardless of the input signal conditions. For example, a Part 15 repeater Frequency Hopping Spread Spectrum (FHSS) system operating under Section 15.247 must meet the receiver requirements in Section 15.247(a)(1) with the input bandwidths that match the FHSS transmit bandwidth, and must hop in synch with the FHSS transmitter Answer: This product complies with all requirements of part 15 subpart C 15.247(FHSS) and sections 15.247(a)1 15.247(b) 15.247(d) 15.247(i)5 5. Tests must show compliance with maximum input levels, for each transmitter with which the repeater is authorized to operate. Answer: Please refer to test report 5.1 A standalone Part 15 amplifier or device that does not uniquely identify the specific signals from transmitters with which it is authorized to operate can only be authorized as a complete transmission system per Section 15.204. Such a device can only be operated in the configuration in which it was authorized, and an equipment authorization for the device will not be issued with a unique FCC ID. Answer: The Repeater is authorization to operate with PG2 products with unique protocol and FCC certified
Visonic Ltd. 13 Zarhin Street P.O.Box 4228 Raanana, 4366241, Israel Tele: +972 3 645 6789 Fax: +972 3 645 6788 www.visonic.com Declaration of Authorization We Name: Visonic Ltd. Address: 13 Zarhin street City: Raanana 4366241 Country: Israel Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 3055001 Country Israel is authorized to apply for Certification of the following product(s): Product description: Wireless Repeater for PowerG Communications Type designation: RP-600 P9M0 Trademark: Johnson Controls, Visonic Validity/expiry date: May 02, 2024 on our behalf. Date: May 02, 2023 City: Tel Aviv Name: Zuri Rubin Function: Certification Manager Signature : Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 Company Name: Visonic Ltd. Address : 13 Zarhin street City: Raanana 4366241 Country: Israel To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: WP3RP600PGP Reference number: 47092 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: in order to avoid exposed of the technology to the competitors Planned Release Date STC: 180 days from the grant date (notes 2, 3, 4, 5) Date: May 02, 2023 Name and signature of applicant: Zuri Rubin Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Visonic Ltd. FCC ID: WP3RP600PGP Page 1 of 4 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Visonic Ltd. FCC ID: WP3RP600PGP Page 2 of 4 Photograph No.1 Wireless Repeater for PowerG Communications Front view Visonic Ltd. FCC ID: WP3RP600PGP Page 3 of 4 Photograph No.2 Wireless Repeater for PowerG Communications Rear side view Visonic Ltd. FCC ID: WP3RP600PGP Page 4 of 4 Photograph No.4 Door/Window Outdoor Contact Rear side view
ECM Title: JCI LABEL DRAWING TBD RAMATEL/ FCC Product Name: LABEL PG+ REPEATER 915 Product Date Name Document No: 4017678 26.06.2022 ALBERT F. Created Document Rev: Draft01 02.05.2023 ALBERT F. Updated Sheet 1 of 1 02.05.2023 SHAY A. Approved MATERIAL: Polyester S-305987 SIZE: 40 x 14 mm. A B A B A A B B B
Visonic Ltd. FCC ID: WP3RP600PGP Page 1 of 4 INTERNAL PHOTOGRAPHS This document contains 4 photographs Visonic Ltd. FCC ID: WP3RP600PGP Page 2 of 4 Photograph No.1 Wireless Repeater for PowerG Communications Internal view Visonic Ltd. FCC ID: WP3RP600PGP Page 3 of 4 Photograph No.2 Wireless Repeater for PowerG Communications Print side of the main PCB Visonic Ltd. FCC ID: WP3RP600PGP Page 4 of 4 Photograph No.3 Wireless Repeater for PowerG Communications Antenna assembly
Visonic Ltd. FCC ID: WP3RP600PGP Exposure limit according to §15.247(i) The magnet contact is classified as a mobile device. The FCC limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 912.75/1500 = 0.61 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4π r 2 P T i s the transmitted power, which is equal to the peak transmitter output power 13.7 dBm plus maximum antenna gain 5 dBi, the maximum equivalent isotropically radiated power EIRP is P T = 13.7 dBm + 5 dBi = 18.7 dBm = 74.13 mW. The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: Compliance with FCC limit: 74.13 mW / 4π (20 cm) 2 = 0.015 mW/cm 2 << 0.61 mW/cm 2 General public cannot be exposed to dangerous RF level.
Johnson Controls 13 Zarhin Street P.O.Box 4228 Raanana 4366241, Israel Tele: +972 3 645 6789 Fax: +972 3 645 6788 Antenna Specification PGP9920, RP-600 PG Plus Diversity antenna with 2 inverted F antennas made of two parts: printed part and through hole wire. The RP-600 PG+ Antenna Diversity solution helps to resolve devices signal strength issues related to range or interference in indoor environment.
Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 61 Report ID: VISRAD_FCC.47092_30824_Rev1.docx Date of Issue: 21-Mar-23 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 15 subpart C §15.247 (FHSS) and subpart B, RSS-247 Issue 2:2017, RSS-Gen Issue 5, ICES-003 Issue 7:2020 FOR: Visonic Ltd. Wireless Repeater for PowerG Communications Model: RP-600 P9M0 FCC ID: WP3RP600PGP This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC.47092_30824_Rev1.docx Date of Issue: 21-Mar-23 Page 2 of 61 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 6 6.1 General information ....................................................................................................................................................... 6 6.2 Test configuration .......................................................................................................................................................... 6 6.3 Changes made in EUT .................................................................................................................................................. 6 6.4 Transmitter characteristics ............................................................................................................................................ 7 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-247 requirements .................................................. 8 7.1 20 dB bandwidth ........................................................................................................................................................... 8 7.2 Carrier frequency separation ....................................................................................................................................... 11 7.3 Number of hopping frequencies .................................................................................................................................. 13 7.4 Average time of occupancy ......................................................................................................................................... 15 7.5 Peak output power ...................................................................................................................................................... 18 7.6 Field strength of spurious emissions ........................................................................................................................... 22 7.7 Band edge radiated emissions .................................................................................................................................... 37 7.8 Conducted emissions .................................................................................................................................................. 41 7.9 Antenna requirements ................................................................................................................................................. 45 8 Unintentional emissions according to 47CFR part 15 subpart B and ICES-003 .......................................................... 46 8.1 Conducted emissions .................................................................................................................................................. 46 8.2 Radiated emission measurements .............................................................................................................................. 51 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 55 10 APPENDIX B Test equipment correction factors ......................................................................................................... 56 11 APPENDIX C Measurement uncertainties .................................................................................................................. 59 12 APPENDIX D Test laboratory description ................................................................................................................... 60 13 APPENDIX E Specification references........................................................................................................................ 60 14 APPENDIX F Abbreviations and acronyms ................................................................................................................. 61 Report ID: VISRAD_FCC.47092_30824_Rev1.docx Date of Issue: 21-Mar-23 Page 3 of 61 1 Applicant information Client name: Visonic Ltd. Address: 24 Habarzel street, Tel Aviv 69…
Text truncated - open the document above for the full version.
Visonic Ltd. FCC ID: WP3RP600PGP Page 1 of 5 SETUP PHOTOGRAPHS This document contains 4 photographs Visonic Ltd. FCC ID: WP3RP600PGP Page 2 of 5 Photograph No.2 Setup for carrier and spurious emissions measurements in anechoic chamber from 30 MHz to 1 GHz Visonic Ltd. FCC ID: WP3RP600PGP Page 3 of 5 Photograph No.3 Setup for field strength measurements in anechoic chamber above 1 GHz Visonic Ltd. FCC ID: WP3RP600PGP Page 4 of 5 Photograph No.4 Setup for carrier field strength measurements, EUT cabling Visonic Ltd. FCC ID: WP3RP600PGP Page 5 of 5 Photograph No.5 Setup for 20 dB bandwidth measurements
Harakevet Industrial zone, P.O.Box 23 · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912.75 MHz - 919.106 MHz | 23.00 mW |

Wireless Motion detector with integrated camera
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Power-G Modem iQ Remote
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
PowerG Wireless Shock Detector
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
PIR detector ZigBee
Equipment Class
DTS - Digital Transmission System
Zigbee Door / Window Contact
Equipment Class
DTS - Digital Transmission System