FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Visonic Ltd./
  3. WP3SMD426-SMD427N

WP3SMD426-SMD427NWireless smoke detector

Visonic Ltd.
Wireless smoke detector - FCC ID WP3SMD426-SMD427N - Visonic Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 29, 2014
Application Purpose
Original Equipment
Date of Application
Sep 28, 2014
Equipment Note
Wireless smoke detector
Frequency Range
912.75000000 - 919.10600000
Company
Visonic Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

D-302894 SMD-426 PG2, SMD-427 PG2 Installation Instructions 1 SMD-426/427 PG2 Supervised Wireless PowerG Smoke Detector / Heat and Smoke Detector Installation Instructions 1. INTRODUCTION SMD-426 PG2 (photoelectric smoke detector) and SMD-427 PG2 (heat and photoelectric smoke detector) are automatic fire detectors with integral audible signal for open area protection, designed to sense heat or smoke (not flame) and fitted with a PowerG type transceiver. SMD-426 PG2 / SMD-427 PG2 provides early warning of developing fire by sounding an alarm with its built-in alarm horn, and by transmitting a coded alarm signal to a PowerG receiver or to a compatible wireless alarm control panel. SMD-427 PG2 will activate a fire alarm upon either smoke or heat condition. With two fire sensors (heat and smoke), the SMD-427 PG2 detector may shorten the time to fire alarm activation. It must be borne in mind, though that effective pre-warning of fire accidents is only possible if the detector is located, installed and maintained as described here. In alarm condition, the buzzer sound can be stopped for 8 minutes (UL) and 10 minutes (EN) by pressing the TEST/MUTE switch. It will not restore the alarm condition, but will temporarily silence the buzzer while you correct the condition. After 8 minutes (UL) and 10 minutes (EN), the detector restarts the alarm buzzer sound. Note: The TEST/MUTE switch functions as TEST switch (in normal operation) or as MUTE switch (in alarm condition). The detector can also operate as a siren to indicate a fire alarm in other areas covered by the alarm system, or to indicate burglar alarm events, as configured through the control panel (see the PowerMaster Installer Guide). The tamper switch actuator (Figures 9a and 9b) is pressed against the bracket when the unit is attached to the bracket. Removal of the unit from the bracket causes the switch contacts to open, creating a tamper event, which is reported by the transceiver to the alarm system control panel. Note: When the tamper switch is opened the detector becomes not ready for operation. A. Buzzer hole B. Test / Mute button & LEDs Figure 1. General View (SMD-427 PG2) 2. INSTALLATION 2.1 Disassembly Separate the unit from its mounting bracket as shown in Figure 2. 1. Hold the bracket with one hand 2. Rotate the detector anticlockwise and pull it from the bracket A. BRACKET B. DETECTOR Figure 2. Separating the Detector from Its Bracket 2.2 Where to Install Smoke Detectors WARNING! To comply with FCC and IC RF exposure compliance requirements, the smoke detector should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. Le dispositif doit être placé à une distance d'au moins 20 cm à partir detoutes les personnes au cours de son fonctionnement normal. Les antennesutilisées pour ce produit ne doivent pas être situés ou exploitésconjointement avec une autre antenne ou transmetteur. Smoke detectors should be installed in accordance with the NFPA Standard 74 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02169). For complete coverage in residential units, smoke detectors should be installed in all rooms, halls, storage areas, basements and attics in each family living unit. Minimum coverage is one detector on each floor and one in each sleeping area and attics in each family living unit. For maximum protection, a smoke detector should be located outside primary sleeping areas or on each level of your home. Here are a few useful tips for you:  Install a smoke detector in the hallway outside every separate bedroom area, as in Figure 3. Two detectors are required in homes with two bedroom areas, as in Figure 4.  Install a smoke detector on every floor of a multi-floor home or apartment, as shown in Figure 5.  Install a minimum of two detectors in any household.  Install a smoke detector inside every bedroom.  Install smoke detectors at both ends of a bedroom hallway if the hallway is more than 12 meters (40 feet) long. A. DINING ROOM B. KITCHEN C. BEDROOM D. LIVING ROOM E. SMOKE DETECTORS FOR MINIMUM PROTECTION F. SMOKE DETECTORS FOR MORE PROTECTION 2 D-302894 SMD-426 PG2, SMD-427 PG2 Installation Instructions Figure 3. Locations for Placing Smoke Detectors in a Single Residence with only One Sleeping Area  Install a smoke detector inside every room where one sleeps with the door partly or completely closed, since smoke could be blocked by the closed door and a hallway alarm may not wake up the sleeper if the door is closed. A. FAMILY ROOM B. KITCHEN C. DINING ROOM D. BEDROOM E. LIVING ROOM F. SMOKE DETECTORS FOR MINIMUM PROTECTION G. SMOKE DETECTORS FOR MORE PROTECTION Figure 4. Locations for Placing Smoke Detectors in Single-Floor Residence with More than One Sleeping Area. A. BEDROOM B. LIVING ROOM C. KITCHEN D. BASEMENT E. GARAGE F. SMOKE DETECTORS FOR MINIMUM PROTECTION G. SMOKE DETECTORS FOR MORE PROTECTION Figure 5. Placing Smoke Detectors in a Multi-Floor Residence  Install basement detectors at the bottom of the basement stairwell.  Install second-floor detectors at the top of the first-to-second floor stairwell.  Be sure no door or other obstruction blocks the path of smoke to the detector.  Install additional detectors in your living room, dining room, family room, attic, utility and storage rooms.  Install smoke detectors as close to the center of the ceiling as possible. If this is not practical, put the detector on the ceiling, at least 10 cm (4 inches) away from any wall or corner, as shown in Figure 6.  If ceiling mounting is not possible and wall mounting is permitted by your local and state codes, locate the detectors between 10 - 15 cm (4 - 6 inches) from the ceiling, also see Figure 6.  If some of your rooms have sloped, peaked, or gabled ceilings, try to mount detectors 0.9 meter (3 feet) measured horizontally from the highest p…

Text truncated - open the document above for the full version.

Cover Letter(s)

September 16, 2014 Telefication B.V. Attn: Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Application for certification of a wireless PowerG smoke detector, FCC ID:WP3SMD426-SMD427N Dear Gentlemen, Please find attached our application for certification of a wireless PowerG smoke detector, FCC ID:WP3SMD426-SMD427N, prepared in accordance with FCC Rules, parts 2 and 15, section 15.247. The product testing and this application for certification were performed by Hermon Laboratories, which is listed by FCC, Registration Numbers 90623, 90624. The FCC Designation Number is US1003. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. We hope this application satisfies your requirements. Please send an invoice to Hermon Labs. Arick Elshtein, International Standards Department Manager Visonic Ltd.

Cover Letter(s)

RF_160, Issue 03 Declaration of Authorization We Name: Visonic Ltd. Address: 24 Habarzel street City: Tel Aviv 61920....................................................... Country: Israel................................................................ Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. ............. Address: Harakevet Industrial Zone .............. City: Binyamina 30500 .............. Country Israel ............. is authorized to apply for Certification of the following product(s): Product description: Wireless smoke detector ................ Type designation: 1) SMD-426 PG2; 1) SMD-427 PG2.... Trademark: Visonic .................................................... on our behalf. Date: July 30, 2014 ................................ City: Tel Aviv................................ Name: Arick Elshtein ................................ (2) Function: International Standards Department ............................... Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Visonic Ltd. Address : Habarzel street 24 City: Tel Aviv 69710 Country: Israel To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: WP3SMD426-SMD427N Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: July 30, 2014 Name and signature of applicant: Mr. Arick Elshtein Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 2 of 3 Photograph No.1 Smoke detector front view Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 3 of 3 Photograph No.2 Smoke detector rear side view

ID Label/Location Info

Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 1 of 3 Label location on the SMD-426 PG2/SMD-427 PG2 smoke detector Label with FCC ID:WP3SMD426-SMD427N and IC:1467C-SMD426427N will be located at the rear side panel. The statement according to FCC part 15 §15.19(a)(3) is placed in Installation Instructions, page 7 (Application exhibit User_manual_24997). Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 2 of 3 Label of the SMD-426 PG2 Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 3 of 3 Label of the SMD-427 PG2

Internal Photos

Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 1 of 7 INTERNAL PHOTOGRAPHS This document contains 6 photographs Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 2 of 7 Photograph No.1 Smoke detector internal view Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 3 of 7 Photograph No.2 Smoke detector PCB front view Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 4 of 7 Photograph No.3 Smoke detector PCB with shield removed Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 5 of 7 Photograph No.4 Detector main PCB second side view Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 6 of 7 Photograph No.5 Detector RFD module front view Visonic Ltd. FCC ID: WP3SMD426-SMD427N IC:1467C-SMD426427N Page 7 of 7 Photograph No.6 RFD module PCB second side view

RF Exposure Info

Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Exposure limit according to §15.247(i) and RSS-102 The device is classified as mobile. Limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 912.75/1500 = 0.61 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4 r 2 P T is the transmitted power, which is equal to the peak transmitter output power 17 dBm plus maximum antenna gain -3 dBi, the maximum equivalent isotropically radiated power EIRP is P T = 17 dBm - 3 dBi = 14 dBm = 25 mW. The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: 25 mW / 4 (20 cm) 2 = 0.005 mW/cm 2 << 0.61 mW/cm 2 General public cannot be exposed to dangerous RF level.

Test Report

Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected] Page 1 of 77 Report ID: VISRAD_FCC_IC.24997_rev1.docx Date of Issue: 23-Jul-14 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 15 subpart C § 15.247 (FHSS), RSS-210 issue 8 Annex 8 FOR: Visonic Ltd. Supervised Wireless PowerG Smoke Detector, model SMD-426 PG2 Supervised Wireless PowerG Heat and Smoke Detector, model SMD-427 PG2 FCC ID: WP3SMD426-SMD427N IC:1467C- SMD426427N This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC_IC.24997_rev1.docx Date of Issue: 23-Jul-14 Page 2 of 77 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in the EUT ............................................................................................................................................ 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-210 Annex 8 requirements .................................... 7 7.1 20 dB bandwidth ........................................................................................................................................................... 7 7.2 Carrier frequency separation ....................................................................................................................................... 12 7.3 Number of hopping frequencies .................................................................................................................................. 15 7.4 Average time of occupancy ......................................................................................................................................... 19 7.5 Peak output power ...................................................................................................................................................... 23 7.6 Band edge radiated emissions .................................................................................................................................... 29 7.7 Field strength of spurious emissions ........................................................................................................................... 34 7.8 Antenna requirements ................................................................................................................................................. 64 8 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 65 9 APPENDIX B Measurement uncertainties ................................................................................................................... 66 10 APPENDIX C Test laboratory description ................................................................................................................... 67 11 APPENDIX D Specification references ....................................................................................................................... 67 12 APPENDIX E Test equipment correction factors ......................................................................................................... 68 13 APPENDIX F Abbreviations and acronyms ................................................................................................................. 77 Report ID: VISRAD_FCC_IC.24997_rev1.docx Date of Issue: 23-Jul-14 Page 3 of 77 1 Applicant information Client name: Visonic Ltd. Address: 24 Habarzel street, Tel Aviv 69710, Israel Telephone: +972 3 645 6714 Fax: +972 3645 6788 E-mail: [email protected] Contact name: Mr. Arik Elshtein 2 Equipment under test attributes Product name: Supervised wireless PowerG smoke detector Product type: Transceiver Model(s): SMD-427 PG2 Cataloque number: 0-500125 Hardware version: 90-203714 Software release: JS-701760 Receipt date 17-Oct-13 3 Manufacturer information Manufacturer name: Visonic Ltd. Address: 24 Habarzel street, Tel Aviv 69710, Israel Telephone: +972 3 645 6714 Fax: +972 3645 6788 E-Mail: [email protected] Contact name: Mr. Arik Elshtein 4 Test details Project ID:…

Text truncated - open the document above for the full version.

Test Setup Photos

Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 1 of 8 SETUP PHOTOGRAPHS This document contains 7 photographs Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 2 of 8 Photograph No.1 Setup for spurious emission field strength measurements in the anechoic chamber below 30 MHz Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 3 of 8 Photograph No.2 Setup for spurious emission field strength measurements in the anechoic chamber in 30 – 1000 MHz range Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 4 of 8 Photograph No.3 Setup for spurious emission field strength measurements in the anechoic chamber above 1000 MHz range Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 5 of 8 Photograph No.4 Setup for carrier emission field strength measurements at the OATS in 30 – 1000 MHz range Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 6 of 8 Photograph No.5 Setup for carrier emission field strength measurements at the OATS, EUT close view Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 7 of 8 Photograph No.6 Setup for OBW and band edge emissions measurements Visonic Ltd. FCC ID:WP3SMD426-SMD427N IC:1467C-SMD426427N Page 8 of 8 Photograph No.7 Setup for hopping parameters measurements

Contact Information

Applicant

Zuri Rubin(Certification Manager)
[email protected]+97236456832Fax: +972 3645 6788

Technical Contact

Hermon Laboratories Ltd.Michael Nikishin
[email protected]972 4626 8440

Harakevet Industrial zone, P.O.Box 23 · Israel

Non-Technical Contact

Visonic Ltd.Arick Elshtein
[email protected]972 3645 6714

Test Firm

Hermon Laboratories Ltd.Alexander Usoskin
[email protected]972-4628-8001Fax: 972-4628-8277

Technical Specifications

#Rule PartsFrequency RangePower Output
115C912.75 MHz - 919.106 MHz50.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Visonic Ltd.

Wireless Motion detector with integrated camera - FCC ID WP3NEXTCAMPGP - Visonic Ltd.
WP3NEXTCAMPGP

Wireless Motion detector with integrated camera

Dec 21, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Repeater for PowerG Communications - FCC ID WP3RP600PGP - Visonic Ltd.
WP3RP600PGP

Wireless Repeater for PowerG Communications

May 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Power-G Modem iQ Remote - FCC ID WP3PGMODIQREM - Visonic Ltd.
WP3PGMODIQREM

Power-G Modem iQ Remote

Jun 02, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PowerG Wireless Shock Detector - FCC ID WP3SD304EPG2 - Visonic Ltd.
WP3SD304EPG2

PowerG Wireless Shock Detector

Jan 03, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PIR detector ZigBee - FCC ID WP3MP843 - Visonic Ltd.
WP3MP843

PIR detector ZigBee

Jun 30, 2020

Equipment Class

DTS - Digital Transmission System