WP3TOWER30PG2Mirror PIR detector

Visonic Ltd.
Mirror PIR detector - FCC ID WP3TOWER30PG2 - Visonic Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 17, 2012
Application Purpose
Original Equipment
Date of Application
Jan 16, 2012
Equipment Note
Mirror PIR detector
Frequency Range
912.75000000 - 919.10600000
Company
Visonic Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Declaration of Authorization We Name: Visonic Ltd. Address: Habarzel street 24, City: Tel Aviv 69710, Country: Israel . Declare that: Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel is authorized to apply for Certification of the following product(s): Product description:  Mirror PIR detector Type designation:  TOWER-30 AM PG2 Trademark:  Visonic . on our behalf. Date: 1/09/2012 Name: Arik Elshtein .. (2) Function: International Standards Department Manager Signature:

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Visonic Ltd. Address : Habarzel street 24 City: Tel Aviv 69710 Country: Israel To: Telefication B.V ., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: WP3TOWER30PG2 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: January 9, 2012 Name and signature of applicant: Mr. Arik Elshtein Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 2 of 3 Photograph No.1 “Tower-30 AM PG2” PIR detector front view Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 3 of 3 Photograph No.2 “Tower-30 AM PG2” PIR detector rear side view

ID Label/Location Info

Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 1 of 1 Label of mirror PIR detector Label location Label with FCC ID:WP3TOWER30PG2 and IC:1467C-TOWER30PG2 will be located at the rear side panel. The statement according to FCC part 15 §15.19(a)(3) is placed in Installation Instructions, page 5 (Application exhibit User_manual_22170). FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2

Internal Photos

Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 1 of 6 INTERNAL PHOTOGRAPHS This document contains 5 photographs Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 2 of 6 Photograph No.1 “Tower-30 AM PG2” PIR detector internal view Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 3 of 6 Photograph No.2 Main PCB with RFD module front view Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 4 of 6 Photograph No.3 Main PCB with RFD module second side view Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 5 of 6 Photograph No.4 RFD module Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 6 of 6 Photograph No.5 RFD module second side view

RF Exposure Info

Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Exposure limit according to §15.247(i) and RSS-102 The device is classified as mobile. Limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 912.75/1500 = 0.61 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4  r 2 P T is the transmitted power, which is equal to the peak transmitter output power 18.92 dBm plus maximum antenna gain -7 dBi, the maximum equivalent isotropically radiated power EIRP is P T = 18.92 dBm -7 dBi = 11.92 dBm = 15.6 mW. The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: 15.6 mW / 4 (20 cm) 2 = 0.003 mW/cm 2 << 0.61 mW/cm 2 General public cannot be exposed to dangerous RF level.

Test Report

Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected] Page 1 of 81 Report ID: VISRAD_FCC.22170.doc Date of Issue: 18-Oct-11 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 15 subpart C § 15.247 (FHSS) and subpart B, RSS-210 issue 8 Annex 8, ICES-003 Issue 4:2004 FOR: Visonic Ltd. PIR Detector (915) Model: Tower-30 AM PG2 FCC ID:WP3TOWER30AMPG2 This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC.22170.doc Date of Issue: 18-Oct-11 Page 2 of 81 Table of contents 1 Applicant information .........................................................................................................................................................3 2 Equipment under test attributes ........................................................................................................................................3 3 Manufacturer information ..................................................................................................................................................3 4 Test details ........................................................................................................................................................................3 5 Tests summary ..................................................................................................................................................................4 6 EUT description .................................................................................................................................................................5 6.1 General information ...........................................................................................................................................................5 6.2 Test configuration ..............................................................................................................................................................5 6.3 Changes made in EUT ......................................................................................................................................................5 6.4 Test configuration ..............................................................................................................................................................6 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-210 Annex 8 requirements .....................................7 7.1 20 dB bandwidth ................................................................................................................................................................7 7.2 Carrier frequency separation...........................................................................................................................................11 7.3 Number of hopping frequencies ......................................................................................................................................13 7.4 Average time of occupancy .............................................................................................................................................16 7.5 Peak output power...........................................................................................................................................................19 7.6 Band edge radiated emissions ........................................................................................................................................24 7.7 Field strength of spurious emissions...............................................................................................................................29 7.8 Antenna requirements .....................................................................................................................................................60 8 Unintentional emissions ..................................................................................................................................................61 8.1 Radiated emission measurements ..................................................................................................................................61 9 APPENDIX A Test equipment and ancillaries used for tests..........................................................................................67 10 APPENDIX B Measurement uncertainties ......................................................................................................................68 11 APPENDIX C Test laboratory description .......................................................................................................................69 12 APPENDIX D Specification references ...........................................................................................................................69 13 APPENDIX E Test equipment correction factors ............................................................................................................70 14 APPENDIX F Abbreviations and acronyms ....................................................................................................................81 Report ID: VISRAD_FCC.22170.doc Date of Issue: 18-Oct-11 Page 3 of 81 1 Applicant information Client name: Visonic Ltd. Address: Habarzel street 24, Tel Aviv 69710, Israel Telephone: +972 3645 6714 Fax: +972 3645 6788 E-mail: [email protected] Contact name: Mr. Arick Elshtein 2 Equipment under test attributes Product name: PIR Detector (915) Product type: Transceiver Model(s): Tower-30 AM PG2 Hardware version: 8-303347 V.01 Software release: JS-7019…

Text truncated - open the document above for the full version.

Test Setup Photos

Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 1 of 6 SETUP PHOTOGRAPHS This document contains 5 photographs Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 2 of 6 Photograph No.1 Setup for spurious emission field strength measurements in the anechoic chamber below 30 MHz Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 3 of 6 Photograph No.2 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber in 30 – 1000 MHz range Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 4 of 6 Photograph No.3 Setup for spurious emission field strength measurements in the anechoic chamber above 1000 MHz Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 5 of 6 Photograph No.4 Setup for spurious emission field strength measurements at the OATS above 1000 MHz Visonic Ltd. FCC ID:WP3TOWER30PG2 IC:1467C-TOWER30PG2 Page 6 of 6 Photograph No.5 Setup for band edge emissions and hopping parameters measurements

Contact Information

Applicant

Zuri Rubin(Certification Manager)
[email protected]+97236456832Fax: +972 3645 6788

Technical Contact

Hermon Laboratories Ltd.
[email protected]

Israel

Test Firm

Hermon Laboratories Ltd.Alexander Usoskin
[email protected]972-4628-8001Fax: 972-4628-8277

Technical Specifications

#Rule PartsFrequency RangePower Output
115C912.75 MHz - 919.106 MHz78.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Visonic Ltd.

Wireless Motion detector with integrated camera - FCC ID WP3NEXTCAMPGP - Visonic Ltd.
WP3NEXTCAMPGP

Wireless Motion detector with integrated camera

Dec 21, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Repeater for PowerG Communications - FCC ID WP3RP600PGP - Visonic Ltd.
WP3RP600PGP

Wireless Repeater for PowerG Communications

May 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Power-G Modem iQ Remote - FCC ID WP3PGMODIQREM - Visonic Ltd.
WP3PGMODIQREM

Power-G Modem iQ Remote

Jun 02, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PowerG Wireless Shock Detector - FCC ID WP3SD304EPG2 - Visonic Ltd.
WP3SD304EPG2

PowerG Wireless Shock Detector

Jan 03, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PIR detector ZigBee - FCC ID WP3MP843 - Visonic Ltd.
WP3MP843

PIR detector ZigBee

Jun 30, 2020

Equipment Class

DTS - Digital Transmission System