Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
P/N MAN-0698/01.01P/N MAN-0698/01.01 Safety recommendations Carefully read all of the cautions and warnings before using the radio: •Do not use the radio equipment for uses different than those indicated in the manual. •For a correct use of the radio equipment, read what is listed in this user's guide. •Protect the radio from sprinklings of water and/or other liquids and from dust. •Be careful not to damage the vehicular radio when cleaning the vehicle. •Do not place the audio accessories above the airbags or in their area of action. If the airbag is activated, it may not swell correctly and/or hurl the audio acces- sories, with great force, inside the passenger compart- ment where the vehicle occupants are located. •Do not use the vehicular radio if the antenna and/or the antenna cable are damaged. •The electronic devices are sensitive to electromagne- tic interference (EMI) if not adequately shielded, desi- gned or configured differently for electromagnetic fields immunity. If electromedical equipment (ex. pace-makers, acou- stical equipment, etc.) is used together with the vehi- cular radio, make sure that it is adequately shielded from external electromagnetic fields. •Install the vehicular radio following the instructions given in the installation guide. The mounting screws can damage cables and wires that run under some mounting surfaces in the vehicle. Be careful to avoid mounting the bracket above these locations. The equi- pment must be installed in such a way that it complies with the national regulations in effect. •Carry out the maintenance interventions on the vehi- cular radio following the instructions given in the tech- nical handbook. •Follow all accident prevention standards when car- rying out maintenance/installation interventions on the vehicular equipment and use the proper tools (span- ners, screwdrivers). •First and second maintenance level interventions on the equipment are to be carried out by authorized technicians only. Third maintenance level interventions are to be carried out by SELEX technicians only. The maintenance le- vels are defined in the technical manual. WARNING This equipment is marked According to the requirements specified in the R&TTE directive 1999/5/EC and the Commission Decision 6th April 2000, the EC marking is accompanied by the Class II equipment class identifier. The equipment (in the 380÷430 MHz and 410÷470 MHz versions) is intended for sell and use in AT, BE, CY, CZ, DK, EE, FI, FR, DE, GR, HU, IE, IT, LV, LT, LU, MT, NL, PL, PT, SK, SI, ES, SE, GB. This equipment requires authorization or license for use. This equipment operates on frequency bands non-harmonised in the EU. This equipment can also be used worldwide where the equipment is approved for use. FCC APPROVAL For US owners only FCC approval VS3000 GTW/806-870 vehicular equipment complies with Part 15 of the FCC/Federal Communication Commission regulations. Operation is governed by the following: FCC ID:X5Y774-0850 FCC ID:X5Y774-0850NB These devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: - these devices may not cause harmful interference, and - these devices must accept any interference received, including interference that may cause undesired operation. Any unauthorized modifications or changes to these devices could void the user's authority to operate these devices. Note: FCC ID X5Y774-0850 and FCC ID X5Y774-0850NB apply to VS3000 GTW/806-870 versions only. P/N MAN-0698/01.01P/N MAN-0698/01.01 •Use only original accessories and spare parts, or approved by the manufacturer, suitable for the vehicu- lar radio. The use of different accessories and/or spare parts (earphone, antenna, etc.) makes the safety and electromagnetic compatibility certifications to be valid no more and it could lower the user safety level and/ or generate electromagnetic fields that exceed the accepted limits. •The emergency call is a priority type call. The vehicular radio, like all mobile telephony equip- ment, operates with radio frequency signals, therefore, the forwarding of the call depends on the network coverage at the moment of the call. •If you need send an emergency call, keep pressed the emergency button for at least 2 seconds, when the radio is switched on. Relating to the radio setting (from PRP), two cases may occur if the transmission is inhibit: a) the emergency call is not sent; it is necessary to disable the Tx Inhibit function from radio menu to forward a call (even if the call is an emergency call). b) the emergency call is sent and automatically the Tx Inhibit function is disabled; from radio menu it is possible to recover the Tx Inhibit function again. •The E-WHERE is only suitable for vehicles with the negative pole of the battery earthed to bodywork. In- stallation on other vehicles can cause faults and dama- ge/fire to cables. • Do not take the radio into environments that have a potentially explosive atmosphere (ex. fuel storage si- tes, filling stations, etc.). •After the radio has been trasmitting for a long period, it may reach high temperatures: in such a case avoid touching the radio shell. The radio complies with all product specifications and great care is taken by the manufacturer so that user safety, as far as the effects of electromagnetic waves on health are concer- ned, is guaranteed within the limits established by the interna- tional specifications. WARNING WARNING To comply with FCC RF exposure compliance require- ments, a separation distance of at least 72 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or ope- rating in conjunction with any other antenna or tran- smitter.”
P/N MAN-0698/01.01 P/N MAN-0698/01.01 P/N MAN-0698/01.01 P/N MAN-0698/01.01 In the vehicular configuration: during normal operation the knob has the volume control function, turn it clockwise toturn up the volume (16 levels) of the audio output of theloudspeaker/earphone.Turn the knob counterclockwise to decrease the volume.If the knob is kept pressed until the alternate symbols S and appear on the display it goes to group-channel selection function. Once in this modality turn the knob tochoose among the available groups and select the group-channel by pressing the knob. Once pressed the knob yougo back to volume control function. If, in group-channel selection modality, no operation on the knob is performed fora pre-defined time interval, the knob automatically changeoversto volume control function. Each changeover of knob functionis signalled to the operator by means of a confirmation beep.In the Motorcycle configuration: the triple pushbutton allows the same operativity of the knob.(“+” to increase the volume/scroll up the groups;“-” to decrease the volume/scroll down the groups; “•” to switch from volume control to group selection/OK).Lit while the radio is receiving.Lit while the radio is transmitting; blinking while the tran-smission is inhibited (only TETRA).When a symbol, or a writing, is present on the display nearthe key, by pressing the key you select the functionassociated to the relative symbol/writing. To scroll up/down the menu items, select the option and escape. The off hook green key is used to accept/make (afterhaving typed in the address) an individual full duplex call and if pressed in idle status accesses the calls list.The on hook red key is used to end the connection. It isalso used to switch on/off the radio if kept pressed for afew seconds.Alphanumeric keypad for dialling numbers and/or strings.It is made up of 12 keys (10 digits plus and ). Clear/escape key.Only for TETRA: if a group is selected, by pressing theyellow key the writing "Dispatcher" on the display appears:now, by pressing PTT (if the network allows this function)the first available dispatcher of the selected group is called(not the group). By pressing again the yellow key the nameof the selected group appears on the display and bypressing PTT the selected group is called. If no group isselected the yellow key allows to make an (half duplex)individual/group call by pressing PTT (after having typedin the address) even if the PTT default modality is set (byPRP) for group/(half duplex) individual call.The key allows to switch the audio from the external loudspeakers to handset accessory and viceversa. (Activeonly if the external loudspeaker and the handset areconnected to the radio).It lets the user send an emergency alarm.To be connected to audio accessories.To be connected to USB-A mass storage device (for FPG3software download).Push-To-Talk button, press it to talk during half duplexconversation.If pressed (in Idle status when a group-channel is se-lected, or after having typed in a group-channel address)it sends the call to the group-channel. See also the yellowkey function description. Signal level (TMO and GTW mode)Network, searching network (flashing)Direct Mode with Gateway equipment presence detectedFallback ModeDirect ModeRepeater Mode (Repeater only)Gateway Mode (Gateway only)Direct Mode with Repeater equipment presence detectedPacket Data ContextPacket Data ChannelE2E Crypto EnableCustom E2EE ErrorCustom E2EE EnableNo read Messages, Full queue with at least one message notread (flashing)Full Queue, each message is readActive Data CallBluetooth ActivatedEarphone Speech CallActive Speech CallKeypad Volume OffKeypad LockedGroup scanning EnabledGroup Attach FailureSDS and voice communication monitoring (Repeater only)Voice communication monitoring (Repeater and Gateway only)SDS monitoring (Repeater only)Helmet detectedRotary Knob EnabledTx ActiveUHF Network ChannelUHF Simplex ChannelLoudspeaker Audio OutputEarphone Audio Output Menu structure © 2010 SELEX Communications S.p.A. - All rights reserved.SELEX Communications S.p.A. reserves the right to change specifications, performance or features relevant to the product descri bed without notice. This is an unpublished work the copyright in which vests in SELEX Communications S.p.A. The information contain ed herein is confidential and the property of SELEX Communications S.p.A. and is supplied without liability for errors or omission s. No part may be reproduced, disclosed or used except as authorised by contract or other written permission. TETRA - Mobile Radio Terminal Quick Reference Guide Controls, indicators and connectors VS3000-FPG3 Displayed symbols SELEX Communications S.p.A. A Finmeccanica Company Via Pieragostini, 80, 16151 - Genova, Italy D R G M M VolumeController/Group -channelSelectorGreen LEDRed LEDFunction KeysMenunavigationkeysOff hook keyOn hook keyAlphanumerickeypadClear keyYellow keySwitch audiokeyEmergency key12 pinsconnectorUSB connector(only vehicular)PTT (Notlocated on theFPG3 frontpanel) Menu NOTES : - Some menus can be or not available according to the configuration of the radio terminal. - Choosing some options of WPS menus can cause the ending of active group calls. E2EE Status (enable/ disable E2EE)E2EE KeyIn Box (TMO, DMO, REP, FM) Out Box (TMO, DMO, FM) Text Message (TMO, DMO, FM) Send Status (TMO, DMO, FM) Char Size (TMO, DMO) Messages (TMO, DMO, REP, FM) Change Mode (TMO, DMO, REP, GTW, FM) Encryption (TMO, and DMO only) Phone Lists Settings Monitor (to check radio coverage, FM only) GPS Information Help Phone Book(user defined TMO andDMO only)Home TETRA(pre-configured phonebook TMO and DMO onlyNon TETRA(pre-configured phonebook, TMO only) Group(To see the configured group s, FM only)Group Management(TMO, DMO and GTW)Calls (TMO and DMO only) Delivery Options(to select the kind of messages deliveryreport, TMO and DMO)Tx Inhibit(to disable/enable the transmission, TMO and DMO only)PreferencesBluetooth (TMO only)…
Text truncated - open the document above for the full version.
Legal details: Via G. Puccini 2 – 16154 Genoa (Italy) Stock capital Euro 60.000.000 fully paid up Fiscal code Genoa's Company Register number 00808100010 V.A.T. 03299110100 Copyright SELEX Elsag S.p.A. - All Rights Reserved Page 1 of 3 Via G. Puccini 2 16154 Genova – Italy SELEX Elsag S.p.A. A wholly-owned subsidiary of Finmeccanica S.p.A. A Finmeccanica Company NON-DISCLOSURE AGREEMENT Code 6AA-GA100368 Ed. 02 This Confidentiality Agreement (hereinafter briefly referred to as Agreement) is stipulated on this ................ and is to be deemed applicable to all information as will be exchanged between the contracting parties within their commercial relationships. The contracting parties are: SELEX Elsag S.p.a, a company subject to direction and coordination of Finmeccanica S.p.a, with registered head office in Genoa, via G. Puccini 2, share capital Euro 60,000,000.00= fully paid up, entered in the Register of Companies of Genoa under No. 00808100010, VAT number 03299110100 and .................................... with registered office in ........................ address .................., share capital ..................... entered in the Register of Companies of ................. under No. ................ VAT number .................. The said Companies may henceforth also be referred to individually as Party, and collectively as Parties. A. For the purposes of this Agreement, the expression “Confidential Information” shall indicate all information (of financial, technical, commercial and any other nature whatsoever), transmitted by a party (the Issuer) to the other (Receiver), either directly or through other parties, within the same Agreement, or anyway within subsequent agreements, invitations to offer, purchase orders, contracts, etc., be it verbal or written or consisting of images, samples, instruments, source-code or object-code software, as well as any other connected information, under any form whatsoever, including, for example and without limitation, data relating to computer programs, models and similar, markets, “business plans”, agreements with third parties, services, customers, commercial or financial aspects of the Issuer, provided that such information, if supplied in writing, reports in a clear and evident manner the expression “proprietary” or “confidential” or, if supplied orally or by images, or however in any non-written form, is identified as “Confidential Information” at the moment that it is given and such qualification is confirmed in writing within 30 (thirty) days. At any rate, during such period all cautions and restrictions set forth in this Agreement for the use and disclosure of “Confidential Information” shall be applied. “Confidential Information” shall also include any information obtained further to examination, testing or analysis of any hardware element, or part thereof, supplied by the “Issuer", even though the above evidence and qualification requirements are not fulfilled. B. The Receiver shall: a) Keep the “Confidential Information” strictly as such and limit the relevant access only to those employees for whom it is necessary within the commercial relationships of the Parties: b) not use the “Confidential Information” for purposes other than those indicated above; c) not disclose the “Confidential Information” without a prior consent in writing from the “Issuer”. It remains understood, however, that each Party shall allow access to “Confidential Information” only to employees of companies of their own Group – or to external Auditors (henceforth also “Auditors”) – who need it exclusively with regard to the subject matter hereof between the Parties. In addition, they shall ensure that such employees or Auditors be previously informed of the confidentiality obligations under this Agreement. The expression Group shall mean, for each Party, the same Party and its subsidiaries – i.e. companies in which such Party has a participation interest exceeding 50% of the share capital – as well as, with regard to SELEX Elsag, the controlling company Finmeccanica S.p.A. Legal details: Via G. Puccini 2 – 16154 Genoa (Italy) Stock capital Euro 60.000.000 fully paid up Fiscal code Genoa's Company Register number 00808100010 V.A.T. 03299110100 Cod. 6AA-GA100368 Ed. 02 NON-DISCLOSURE AGREEMENT Copyright SELEX Elsag S.p.A. - All Rights Reserved Page 2 of 3 Via G. Puccini 2 16154 Genova – Italy SELEX Elsag S.p.A. A wholly-owned subsidiary of Finmeccanica S.p.A. C. The obligations and restrictions under the preceding item shall not apply to information in respect of which the “Receiver” is able to prove: a) that it was already known to such Party, without any limitation to its use or diffusion, prior to its transmission under this Agreement; b) that it is public, or has become such, for reasons other than the stipulation/termination of the Agreement; c) that it has been legally obtained from a third party, with no communication relevant to the presence of restrictions to its use and diffusion; d) that it has been developed and inferred by the “Receiver” independently of the received “Confidential Information”; e) that it is used or spread in compliance with laws or regulations or pursuant to measures of Authorities. D. For the purposes of this Agreement, “Classified Information” shall mean information, documents and any kind of news which the Government of the “Issuer’” Country has submitted or intends to submit to security measures, regardless of whether such information is transmitted orally, electronically, in writing or by material delivery. Each Party therefore undertakes to apply the provisions relevant to such security measures, as transmitted to such Party by the “Issuer” and set forth by the national Government of the latter with regard to: disclosure of “Classified Information”; reception of “Classified Information”; protection, use and treatment of “Classified Information”. the provisions of this clause shall at any rate remain in force even…
Text truncated - open the document above for the full version.
TETRA TERMINAL DEVICES 870 TUNE UP INFORMATIONS 19/07/2012 codice tecnico . 1 A Finmeccanica Company FCC ID: X5Y774-0788 Product Name: PUMA T3 Plus/806-870 FCC ID: X5Y774-0788NB Product Name: PUMA T3 Plus/806-870 FCC ID: X5Y774-0850 Product Name: VS3000 GTW/806-870 FCC ID: X5Y774-0850NB Product Name: VS3000 GTW/806-870 Tune up Informations No tune up procedure is required by technician or user after the device has left the factory to match its specifications on the working frequency. The PUMA T3 Plus/806-870 and VS3000 GTW/806-870 device has no manual trimmers or adjustments that can be manually done on it acting directly on the device itself.
Prediction of MPE limit at a given distance S = power density P = power input to the antenna G = antenna gain R = distance Conducted output power:40.00(dBm) 10000(mW) 10(W) Antenna gain:5(dBi) Maximum antenna gain:3.162(numeric) EIRP31.62(W) Distance:72(cm) Duty Cycle(SourceBased):25(%) Frequency:809(MHz) MPE Limit:0.539(mW/cm^2) Power density:0.121(mW/cm^2) 1.21(W/m^2) Margin6.5(dB) 2 4R PG S p =
www.nemko.com Nemko Italy S.p.A., Via del Carroccio 4, 20853, Biassono, Italy. Report number: 212207-2TRFMPE Apparatus: VS3000 GTW/806-870 Applicant: SELEX Elsag S.p.A. Via Giacomo Puccini, 2 - 16154 Genova- Italy FCC ID: X5Y774-0850NB Test specification: MPE ASSESSMENT Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Reviewed by: 2012-08-07 Signature Date G. Curioni, Wireless/EMC Specialist Tested by: 2012/08/07 Signature Date D. Guarnone, Wireless/EMC Specialist Nemko S.p.A. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko S.p.A. accepts no responsibility for damages, if any suffered by any third party as a result of decisions made or actions based on this report. This report shall not be reproduced except in full without the written approval of the testing laboratory. www.nemko.com Nemko Italy S.p.A., Via del Carroccio 4, 20853, Biassono, Italy Report Number: 212207-2TRFMPE Specification: -- Page 2 of 24 Table of contents Section 1: Report summary ................................................................................................................... 3 Section 2: Equipment under test .......................................................................................................... 4 2.1 Identification of equipment under test (EUT) ............................................................................ 4 2.2 Accessories and support equipment ......................................................................................... 5 2.3 EUT description ........................................................................................................................ 6 2.4 Technical specifications of the EUT .......................................................................................... 6 2.5 EUT setup diagram................................................................................................................... 7 2.6 Operation of the EUT during testing ......................................................................................... 8 2.7 Modifications incorporated in the EUT ...................................................................................... 8 Section 3: Test conditions .................................................................................................................... 9 3.1 Deviations from laboratory tests procedures ............................................................................. 9 3.2 Test conditions, power source and ambient temperatures ........................................................ 9 3.3 Measurement uncertainty ......................................................................................................... 9 3.4 Test equipment ......................................................................................................................... 9 Section 4: Result summary ................................................................................................................. 10 4.1 MPE: Test results ................................................................................................................... 10 Appendix A: Test results ..................................................................................................................... 11 MPE CALCULATION ....................................................................................................................... 11 MPE CALCULATION, continue.. ...................................................................................................... 12 Nemko Italy S.p.A. Via del Carroccio 4, 20853 Biassono, Italy. Section 1: Report summary Report Number: 212207-2TRFMPE Specification: -- Page 3 of 24 Section 1: Report summary This report contains an assessment of apparatus against specifications based upon tests carried out on samples submitted at Nemko Italy SpA. Test specification: Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Compliance status: Complies Exclusions: None Non-compliances: None Report release history: Original release Test location: SELEX ELSAG Via Eugenio Barsanti, Firenze, Italy. Registration number: 481407 (10 m Semi anechoic chamber) These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Italy’s ISO/IEC 17025 accreditation. Nemko Italy SpA. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Italy SpA. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Nemko Italy S.p.A. Via del Carroccio 4, 20853, Biassono, Italy Section 2: Equipment under test Report Number: 212207-2TRFMPE Specification: -- Page 4 of 24 Section 2: Equipment under test 2.1 Identification of equipment under test (EUT) The following information identifies the EUT under test: Type of equipment: Mobile Rad…
Text truncated - open the document above for the full version.
www.nemko.com Nemko Italy S.p.A., Via del Carroccio 4, 20853, Biassono, Italy. Report number: 212207-2TRFWL Apparatus: VS3000 GTW/806-870 Applicant: SELEX Elsag S.p.A. Via Giacomo Puccini, 2 - 16154 Genova- Italy FCC ID: X5Y774-0850NB Test specification: Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter D – Safety and special radio services Part 90 – Private land mobile services − Subpart I – General technical standards Reviewed by: 2012-08-06 Signature Date G. Curioni, Wireless/EMC Specialist Tested by: 2012/08/06 Signature Date D. Guarnone, Wireless/EMC Specialist Nemko S.p.A. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko S.p.A. accepts no responsibility for damages, if any suffered by any third party as a result of decisions made or actions based on this report. This report shall not be reproduced except in full without the written approval of the testing laboratory. www.nemko.com Nemko Italy S.p.A., Via del Carroccio 4, 20853, Biassono, Italy Report Number: 212207-2TRFWL Specification: FCC 90 Page 2 of 47 Table of contents Section 1: Report summary ................................................................................................................... 3 Section 2: Equipment under test .......................................................................................................... 4 2.1 Identification of equipment under test (EUT) ............................................................................ 4 2.2 Accessories and support equipment ......................................................................................... 5 2.3 EUT description ........................................................................................................................ 6 2.4 Technical specifications of the EUT .......................................................................................... 6 2.5 EUT setup diagram................................................................................................................... 7 2.6 Operation of the EUT during testing ......................................................................................... 7 2.7 Modifications incorporated in the EUT ...................................................................................... 7 Section 3: Test conditions .................................................................................................................... 7 3.1 Deviations from laboratory tests procedures ............................................................................. 8 3.2 Test conditions, power source and ambient temperatures ........................................................ 8 3.3 Measurement uncertainty ......................................................................................................... 9 3.4 Test equipment ......................................................................................................................... 9 Section 4: Result summary ................................................................................................................. 10 4.1 FCC Part 90: Test results ....................................................................................................... 10 Appendix A: Test results ..................................................................................................................... 11 Clause 90.205 Output power ............................................................................................................ 11 Clause 90.207 Modulation characteristics ........................................................................................ 15 Clause 90.209 Occupied bandwidth ................................................................................................ 16 Clause 90.210 Spurious emissions at the antenna terminal ............................................................. 23 Clause 90.210 Field strength of spurious radiation ........................................................................... 33 Clause 90.213 Frequency stability .................................................................................................... 43 Clause 90.219 Use of boosters ........................................................................................................ 46 Appendix B: Block diagrams of test set-ups ..................................................................................... 47 Nemko Italy S.p.A. Via del Carroccio 4, 20853 Biassono, Italy. Section 1: Report summary Report Number: 212207-2TRFWL Specification: FCC 90 Page 3 of 47 Section 1: Report summary This report contains an assessment of apparatus against specifications based upon tests carried out on samples submitted at Nemko Italy SpA. Test specification: FCC Part 90 Private land mobile services Subpart I – General technical standards Compliance status: Complies Exclusions: None Non-compliances: None Report release history: Original r…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 9 | 854.0125 MHz - 868.9875 MHz | 10 W | 20K0D1D | 1.5 ppm |

ECOSD RBS4000K U5110DA0C14W0E100S1V1G2
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
VS4000 806-870
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
ECOSD RBS4000K U4110DA0C14W0E100S1V1G2
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
BS NODE-470
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
PUMA T3 Plus/806-870
Equipment Class
TNE - Licensed Non-Broadcast Transmitter Held to Ear