FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Aeon Labs LLC./
  3. XBA20100902

XBA20100902SMART ENERGY SWITCH

Aeon Labs LLC.
SMART ENERGY SWITCH - FCC ID XBA20100902 - Aeon Labs LLC.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 12, 2010
Application Purpose
Original Equipment
Date of Application
Sep 12, 2010
Equipment Note
SMART ENERGY SWITCH
Frequency Range
908.42000000 - 908.42000000
Company
Aeon Labs LLC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Aeon Labs Smart Energy Switch (Z-Wave Appliance Module w/ Energy Monitor) Introduction: The Aeon Labs Smart Energy Switch is a Z-Wave appliance switch which can report wattage energy usage or kWh energy usage to a Z-Wave gateway. It can also be controlled by other Z-Wave devices to turn on/off to save electricity when appropriate. It also is a repeater in the Z-Wave network. Acting as a bridge for communication, it will forward Z-Wave command messages to their destinations if the originating controller is out of range from the destination node. With an unobtrusive sma ll form factor, the Aeon Labs Smart Energy Switch will not block other nearby AC outlets. It is available in both matte white and matte black colors. By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. Z-Wave Network Instructions : The Aeon Labs Smart Energy Switch must be paired (included) into a Z-Wave network before it can receive Z-Wave commands to turn on/off and report its energy usage. The smart energy switch can only communica te to devices within it’s own z-wave network. Note : The LED on the Smart Energy Switch will blink if it is currently not paired into a Z-Wave network.  Adding/Including/Pairing the Smart Energy Switch into a Z-Wave Network 1. Press the button on the Aeon Labs Z-Stick to begin the Z-Wave inclusion process. OR Press the button labeled “Include” on the Aeon Labs Minimote to begin the Z-Wave inclusion process. Note : To include the Aeon Labs Smart Energy Switch with other controllers, please consult the operation manual for these controllers on how to include Z-Wave products into an existing network. For instructions on select partner gateways, visit www.aeon- labs.com/support . 2. While the Smart Energy Switch is plugged into the outlet, press the button located between the LED. Troubleshooting : If the Aeon Labs Smart Energy Switch was not successfully included into any Z-Wave network, the LED will be blinking. If the Aeon Labs Smart Energy Switch was successfully included to a Z-Wave network, the LED will either be on or off (depending on if the switch is on or off).  Removing/Resetting the Smart Energy Switch from your Z-Wave Network 1. Hold the button on the Aeon Labs Z-Stick to begin the Z-Wave removal process. OR Press the button labeled “Remove” on the Aeon Labs Minimote Stick to begin the Z-Wave removal process. Note : To include the Aeon Labs Smart Energy Switch with other controllers, please consult the operation manual for these controllers on how to include Z-Wave products into an existing network. For instructions on select partner gateways, visit www.aeon- labs.com/support . 2. While the Smart Energy Switch is plugged into the outlet, press the button located between the LED. Troubleshooting : If the Aeon Labs Smart Energy Switch was removed from the Z-Wave network, the LED will be blinking. If the Aeon Labs Smart Energy Switch was not successfully removed from the Z-Wave network, the LED will either be on or off (depending on if the switch is on or off).  Turning On/Off the Smart Energy Switch Use any of the below methods to allow power through or cut power from the Smart Energy Switch. o Through the usage of Z-Wave commands built into Z-Wave certified controllers and gateways. (The specific Z-Wave commands supporting this function are the Basic Command Class and Binary Switch Command Class.) Please consult the operation manual for these controllers for specific instructions on controlling the Smart Energy Switch. o Pressing the button on the Smart Energy Switch will toggle power flow (on/off) through the Smart Energy Switch.  Monitoring Energy Consumption The Aeon Labs Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z-Wave gateway or controller when requested. If this function is supported by the gateway/controller, the energy consum ption will be displayed in the user interface of the gateway/controller. (The specific Z-Wave commands supporting energy monitoring are the Meter Command Class and Multilevel Sensor Command Class.) Please consult the operation manual for these gateways/controllers for specific instructions on monitoring the Smart Energy Switch.  Technical Specifications o USA: 120V 60Hz input, 1875W or 15A max output o EU: 250V 50Hz input, 4000W or 16A max output o AU: 240V 50Hz input, 2400W or 10A max output Warranty Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as defined below), the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer. Warranty claims must be made by Customer in writing within thirty (30) days of the manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to re pair, replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the purchase price to Customer. The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under Aeon Labs’ RMA policy. Any repairs conducted by unauthorized persons shall void this warranty. Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse, misapplication, storage damage, negligence, electrical power problems, or modification to the Products or its components. Aeon Labs does not author ize any person or party to assume or create for it any other obligation or liability in co nnection with the P…

Text truncated - open the document above for the full version.

Cover Letter(s)

Aeon Labs LLC. September 23, 2010. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: XBA20100902. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram XBA20100902_BlcokDiagram.pdf Schematics XBA20100902_SchematicDiagram.pdf Circuit Description XBA20100902_CircuitDescription.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, we are aware that the exhibits listed above have publicly available since 09/13/2010 the date the grant was issued. Sincerely, Aeon Labs LLC. ---------------------------------------------------------- William Li (Director of Business Development)

External Photos

Page 18 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F Figure 1 The EUT-Front View Figure 2 The EUT-Back View

ID Label/Location Info

FCC ID Label Sample for FCC ID: XBA20100902_ FCC ID: XBA20100902 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

The proposed Label Location on EUT Proposed FCC ID Label Location Proposed Label Location on EUT The EUT-Back View/Proposed FCC ID Label Location

Internal Photos

Page 19 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F Figure 4 PCB of the EUT-Front View Figure 5 PCB of the EUT-Back View Page 20 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F Figure 6 PCB of the EUT-Front View (RF module) Figure 7 PCB of the EUT-Back View (RF module)

Test Report

Page 1 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F FCC TEST REPORT for Aeon Labs LLC. Smart Energy Switch Model No.: DSC06106-ZWUS Report Number : 201002668F Date of Test : Aug. 24~28, 2010 Date of Report : Sept. 02, 2010 Prepared for : Aeon Labs LLC. Address : 121 Buckingham drive, unit36 santa claras CA95051 USA Tel: (1) 408-248 2013 Fax: (1) 408-248 2013 Prepared By : Anbotek Compliance Laboratory Limited Address : 1/F, 1 /Building, SEC Industrial Park, No. 4 Qianhai Road, Nanshan District, Shenzhen, 518054, China Tel: (86) 755-26014771 Fax: (86) 755-26014772 Page 2 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F TABLE OF CONTENT Description Page Test Report 1. GENERAL INFORMATION .........................................................................................................4 1.1. Description of Device (EUT)....................................................................................................................4 1.2. Description of Test Facility ......................................................................................................................5 1.3. Measurement Uncertainty.........................................................................................................................5 2. MEASURING DEVICE AND TEST EQUIPMENT.................................................................... 6 3. TEST PROCEDURE ....................................................................................................................... 7 4. CONDUCTED LIMITS .................................................................................................................. 8 4.1. Block Diagram of Test Setup ...................................................................................................................8 4.2. Power Line Conducted Emission Measurement Limits (15.207) .............................................................8 4.3. Configuration of EUT on Measurement ...................................................................................................8 4.4. Operating Condition of EUT ....................................................................................................................8 4.5. Test Procedure ..........................................................................................................................................9 4.6. Power Line Conducted Emission Measurement Results ..........................................................................9 5. RADIATION INTERFERENCE.................................................................................................. 12 5.1. Requirements (15.249, 15.209): .............................................................................................................12 5.2 Test Procedure .........................................................................................................................................12 5.3 Test Results..............................................................................................................................................12 6. OCCUPIED BANDWIDTH..........................................................................................................14 6.1. Requirements (15.249): ..........................................................................................................................14 6.2 Test Results..............................................................................................................................................14 7. PHOTOGRAPH............................................................................................................................. 16 7.1. Photo of Power Line Conducted Emission Measurement ......................................................................16 7.2. Photo of Radiation Emission Test ..........................................................................................................16 APPENDIX I (Photos of EUT) (3 Pages) Page 3 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F TEST REPORT Applicant : Aeon Labs LLC. Manufacturer : Aeon Labs LLC. EUT : Smart Energy Switch Model No. : DSC06106-ZWUS Serial No. : N/A Rating : AC 110-240V, 50/60Hz Trade Mark : N/A Measurement Procedure Used: FCC Part15 Subpart C, Paragraph 15.207, 15.209&15.249 The device described above is tested by Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Anbotek Compliance Laboratory Limited Date of Test : Aug. 24~28, 2010 Prepared by : (Tested Engineer / Well Wang) Reviewer : (Project Manager / Coco Xiang) Approved & Authorized Signer : (Manager / Tom Chen) Page 4 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT : Smart Energy Switch Model Number : DSC06106-ZWUS Test Power Supply : AC 120V, 60Hz Frequency : 908.42MHz Antenna : Gain is 2dBi (The antenna used in this product is non-removable antenna) Applicant : Aeon Labs LLC. Address : 121 Buckingham drive, unit36 santa claras CA95051 USA Manufacturer : Aeon Labs LLC. Address : 121 Buckingham drive, unit36 santa claras CA95051 USA Date of receiver : Aug. 24, 2010 Date of Test Aug. 24~28, 2010 Page 5 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F 1.2. Description of Tes…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 16 of 20 FCC ID: XBA20100902 Anbotek Compliance Laboratory Limited Report No.201002668F 7. PHOTOGRAPH 7.1. Photo of Power Line Conducted Emission Measurement 7.2. Photo of Radiation Emission Test

Contact Information

Applicant

William Li(Director of Business Development)
[email protected](408) 248-2013Fax: (408) 248-2013

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedDaniel zhu
[email protected]86-755-26014771

Technical Specifications

#Rule PartsFrequency RangePower Output
115C908.42 MHz - 908.42 MHz-
Confidentiality
Long Term

Other Applications from Aeon Labs LLC.

Smart Strip Gen5,Strip Gen5 - FCC ID XBAZW069 - Aeon Labs LLC.
XBAZW069

Smart Strip Gen5,Strip Gen5

Jan 25, 2016

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
DSC17103-ZWUS,DSC14104-ZWUS - FCC ID XBADSC14104 - Aeon Labs LLC.
XBADSC14104

DSC17103-ZWUS,DSC14104-ZWUS

Dec 28, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Smart Dimmer 6,Dimmer,Dimmer 6 - FCC ID XBAFT099 - Aeon Labs LLC.
XBAFT099

Smart Dimmer 6,Dimmer,Dimmer 6

Dec 23, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Door/Window Sensor Gen5 - FCC ID XBAZW120 - Aeon Labs LLC.
XBAZW120

Door/Window Sensor Gen5

Nov 30, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Doorbell Gen5 - FCC ID XBAZW056 - Aeon Labs LLC.
XBAZW056

Doorbell Gen5

May 21, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified