FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Aeon Labs LLC./
  3. XBAZW090

XBAZW090Z-Stick Gen5/Z-Stick Lite Gen5

Aeon Labs LLC.
Z-Stick Gen5/Z-Stick Lite Gen5 - FCC ID XBAZW090 - Aeon Labs LLC.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Mar 24, 2015
Application Purpose
Original Equipment
Date of Application
Mar 24, 2015
Equipment Note
Z-Stick Gen5/Z-Stick Lite Gen5
Frequency Range
908.40000000 - 908.42000000
Company
Aeon Labs LLC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

View the expanded manual: http://aeotec.com/support Aeotec by Aeon Labs Z-Stick. Aeon Labs Z-Stick Gen5 is a self- powered Z-Wave USB adapter with remote network creation capabilities (independent from external power and host microprocessor). By being able to remotely include/remove Z-Wave devices, this greatly simplifies Z-Wave network installation. When connected to a host controller (via USB), it enables the host controller to take part in the Z-Wave Network. The Z-Stick Gen5 is also device firmware upgradeable by the end consumer. This enables the product to always have the latest Z-Wave protocol, capabilities and commands. By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. The Z-Stick operates in three distinct modes: Inclusion-Mode, Removal- Mode and SerialAPI-Mode. Both Inclusion-Mode and Removal-Mode require the Z-Stick to be unplugged from the USB connector of the host, while SerialAPI-Mode requires that the Z-Stick to be plugged into the USB connector of the host. Software drivers for the “ZW050x_USB_VCP_ PC_Driver” may need to be installed in order for the Z-Stick to be recognized on some computers (drivers can be found at http://www.aeotec.com/ support). 1. To initiate Inclusion-Mode, unplug the Z-Stick from the USB connector and then tap the Action Button. (The blue LED will blink slowly.) 2. To include a new Z-Wave device into the network, simply go to the device with the Z-Stick and press the button on the device you wish to include. (The blue LED on the Z-Stick will blink fast during a network neighbour discovery and stay solid for 2 seconds to indicate successful inclusion of the device into the network.) 1. To initiate Removal-Mode, unplug the Z-Stick from the USB connector. Then press and hold down the Action Button for approximately 2 seconds. (The orange LED will blink fast.) 2. To remove a Z-Wave device from the network, simply go to the device with the Z-Stick and press the button on the device you wish to remove. (The blue LED on the Z-Stick will immediately stay solid for 2 seconds to indicate successful removal from the network.) 3. The orange LED will then return to blink fast, indicating readiness for further device exclusions. Repeat step 2 for each device you wish to exclude. 4. Tap the Z-Stick’s Action Button to turn it off or it will automatically exit the removal mode after 30 seconds of inactivity. To initiate SerialAPI-Mode, plug the Z-Stick into the USB connector of the host (i.e. PC, MAC, or Gateway). Note: 1). While in SerialAPI-mode, the Z-Stick is always listening (it is awake and always in RX receive mode) for instructions and acts as a Z-Wave adapter and responds to commands sent through USB by the host processor software. 2). Pressing the Action Button will not have any effect while in SerialAPI- Mode. But short pressing the Reset Button will reset the USB port. This must be done through the host software which takes control of the Z-Stick USB adapter while the Z-Stick is in SerialAPI-Mode. Please consult the instruction manual of the host software to add the Z-Stick to a pre- existing Z-Wave network (i.e. “Learn”, “Sync”, “Add as Secondary Controller”, etc.). This function can only be performed via host software. Familiarize yourself with your Z-Stick. Quick start. Inclusion-Mode: Adding/Including Z-Wave Devices into the Z-Wave Network. Removal-Mode: Deleting/ Removing/Excluding Z-Wave Devices from the Z-Wave Network. SerialAPI-Mode: Allowing a Host Processor To Take Control of the Z-Stick and Take Part in the Z-Wave Network. Installation and Maintenance Application (IMA) feature. Add the Z-Stick to a pre-existing Z-Wave network. When the Z-Stick acts an independent/ secondary controller that has been un- plugged from the USB host, it also can measure the network health in Z-Wave network. The different colour of LED on the Z-Stick indicates the communication quality between the Central Controller and the current location of Z-Stick in the network. Short press the Action Button 5 times, if the colour of LED is changed to purple and then it follows with fast blink, which means it goes into the IMA feature. The colour of LED will be changed according to the network health level. If the colour of LED is changed to green, which means the current communication quality is more than 95% on -7dBm. If the colour of LED is changed to orange, which means the current communication quality is more than 95% on 0dBm. If the colour of LED is changed to purple, which means the current communication quality is less than 95% on 0dBm. If the colour of LED is changed to red, which means the current communication has failed. Short press the Action Button 5 times again, the Z-Stick will automatically exit the IMA feature. When the Z-Stick is in Serial API- Mode and acts a primary controller, it can measure the network health for each device in the network. The different colour of LED indicates the communication quality between the Z-Stick Controller and devices in the network. Install the IMA tool software first (note: the IMA tool can be downloaded from here: http://www.aeotec.com/support). Select the node device and then click the IMA test button to start the IMA test between the Central Controller and the node devices. Your IMA tool client will receive the test result and use different colour of LED icon to indicate the network health level, its colour will be changed follow with the change of network health level. If the colour of LED is changed to green , which means the current network quality is good. If the colour of LED is changed to orange , which means the current network quality is acceptable but latency can occur. If the colour of LED is changed to red , which means the current network quality is insufficient. If the IMA tool return a , which means the current network is …

Text truncated - open the document above for the full version.

Cover Letter(s)

Aeon Labs LLC. Federal Communications Commission Authorization and Evaluation Division Date:2015/03/24 Confidentiality Request regarding application for certification of FCC ID:XBAZW090. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description XBAZW090_SCH.pdf XBAZW090_BlockDiagram.pdf XBAZW090_ Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Aeon Labs LLC. ................................................... Signature ................................................... William Li / Director of Business Development

Cover Letter(s)

Aeon Labs LLC. FCC ID:XBAZW090 POWER OF ATTORNEY Date:2015/03/24 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on 2016/03/23. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We,Aeon Labs LLC. are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Aeon Labs LLC. ................................................... Signature ................................................... William Li/Director of Business Development

ID Label/Location Info

FCC Label Location for model: ZW090-A The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. FCC ID: XBAZW090 Proposed Label Location on EUT EUT Back View/ proposed IC Label Location Imation Corp. FCC ID:XXXXX IC:6900A-MT212 Model: MW212 This device complies with part 15 of the FCC rules and industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

FCC Label Sample for model: ZW090-A FCC ID: XBAZW090 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Test Report

TEST REPORT Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Page 1 of 29 Reference No. .................... : WTS15S0122741E FCC ID ................................ : XBAZW090 Applicant ............................ : Aeon Labs LLC. Address .............................. : 121 Buckingham Drive Unit 36 Santa Claras California United States Manufacturer .................... : Fantem Technologies (Shenzhen) Co.,Ltd Address .............................. : North,3/F, Yitoa Technology Industrial Park,Baihua Yuan Rd.,The Second Industrial Area,Guangming Sub-district Office,Guangming New District,Shenzhen, Guangdong, China Product Name .................... : Z-Stick Gen5、Z-Stick Lite Gen5 Model No. ........................... : ZW090-A、ZW092-A Trade Mark ......................... : AEON LABS/Aeotec Standards .......................... : FCC CFR47 Part 15 Section 15.249: 2014 Date of Receipt sample .... : Jan.28, 2015 Date of Test ....................... : Jan.30~Feb.09, 2015 Date of Issue ...................... : Mar. 14, 2015 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Zero Zhou / Project Engineer Philo Zhong / Manager Reference No.: WTS15S0122741E Page 2 of 29 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Test Summary Test Items Test Requirement Result Conducted Emissions 15.207 PASS Radiated Emission 15.249(a) 15.209 15.205(a) PASS Periodic Operation 15.35(c) PASS Outside of Band Emission 15.249 15.205 15.209 PASS 20dB Bandwidth 15:215(c) PASS Antenna Requirement 15.203 PASS Reference No.: WTS15S0122741E Page 3 of 29 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 TEST SUMMARY .................................................................................................................................................. 2 3 CONTENTS ............................................................................................................................................................ 3 4 GENERAL INFORMATION .................................................................................................................................. 4 4.1 GENERAL DESCRIPTION OF E.U.T. ............................................................................................................ 4 4.2 DETAILS OF E.U.T. ..................................................................................................................................... 4 4.3 TEST FACILITY ............................................................................................................................................ 4 5 EQUIPMENT USED DURING TEST .................................................................................................................. 5 5.1 EQUIPMENTS LIST ...................................................................................................................................... 5 5.2 MEASUREMENT UNCERTAINTY ................................................................................................................... 5 5.3 TEST EQUIPMENT CALIBRATION................................................................................................................. 5 6 CONDUCTED EMISSION .................................................................................................................................... 6 6.1 E.U.T. OPERATION ..................................................................................................................................... 6 6.2 EUT SETUP ................................................................................................................................................ 6 6.3 MEASUREMENT DESCRIPTION ................................................................................................................... 6 6.4 TEST RESULT ............................................................................................................................................. 7 7 RADIATION EMISSION TEST .......................................................................................................................... 11 7.1 EUT OPERATION ...................................................................................................................................... 11 7.2 TEST SETUP ............................................................................................................................................. 12 7.3 SPECTRUM ANALYZER SETUP .................................................................................................................. 13 7.4 TEST PROCEDURE .................................................................................................................................... 14 7.5 TEST RESULT ........................................................................................................................................... 15 8 PERIODIC OPERATION .................................................................................................................................... 16 9 OUTSIDE OF BAND EMISSION ....................................................................................................................... 17 9.1 TEST PROCEDURE .....................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

William Li(Director of Business Development)
[email protected](408) 248-2013Fax: (408) 248-2013

Test Firm

Waltek Services(Shenzhen) Co., Ltd.philo zhong
[email protected]8675527553488Fax: 8675527553868

Technical Specifications

#Rule PartsFrequency RangePower Output
115C908.4 MHz - 908.42 MHz-
Confidentiality
Long Term

Other Applications from Aeon Labs LLC.

Smart Strip Gen5,Strip Gen5 - FCC ID XBAZW069 - Aeon Labs LLC.
XBAZW069

Smart Strip Gen5,Strip Gen5

Jan 25, 2016

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
DSC17103-ZWUS,DSC14104-ZWUS - FCC ID XBADSC14104 - Aeon Labs LLC.
XBADSC14104

DSC17103-ZWUS,DSC14104-ZWUS

Dec 28, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Smart Dimmer 6,Dimmer,Dimmer 6 - FCC ID XBAFT099 - Aeon Labs LLC.
XBAFT099

Smart Dimmer 6,Dimmer,Dimmer 6

Dec 23, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Door/Window Sensor Gen5 - FCC ID XBAZW120 - Aeon Labs LLC.
XBAZW120

Door/Window Sensor Gen5

Nov 30, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Doorbell Gen5 - FCC ID XBAZW056 - Aeon Labs LLC.
XBAZW056

Doorbell Gen5

May 21, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified