Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Coppernic 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: Coppernic Address: 20,rue Georges Claude Aix en Provence France 13290 Product Name: access-ER HF ASK / access-ER HF ASK RCTIF FCC ID: XGK-ACERASK Model(s): access-ER 2.911(d)(5)(i) EquipmentType We, [Coppernic] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Marc Piepers Date: 3/9/2023 Title and Company name: Chief Technical Officer / Coppernic NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Coppernic 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Coppernic Address: 20,rue Georges Claude Aix en Provence France 13290 Product Name: access-ER HF ASK / access-ER HF ASK RCTIF FCC ID: XGK-ACERASK Model(s): access-ER 2.911(d)(5)(ii) Applicant filing We, [Coppernic] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: Marc Piepers Date: 3/9/2023 Title and Company name: Chief Technical Officer / Coppernic NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
THREE STONES MEDIA LLC U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: 03-09-2023 Ref: Attestation Statement – Part2.911(d)(7) filing FCC ID:XGK-ACERASK Coppernic (“the applicant”) certifies that, as of the date of the filing of the application, THREE STONES MEDIA LLC(“the agent”) is our designated U.S. agent for service of process for the abovereference FCC ID. The applicant accepts to maintain an agent for service of process in the United States forno less than one year after either the grantee has permanently terminated all marketing and importation of theapplicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicialproceeding involving the equipment, whichever is later. The applicant further acknowledges it is ourresponsibility to inform the FCC whenever the agent information changes. THREE STONES MEDIA LLC ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: THREE STONES MEDIA LLC FRN: 0033401761 GC: 2A99E Address: 1200 Broadway St. APT 329, Los Angeles, CA90015 Signature: Contact Person: Sijie Zhang Tel: +1 267 909 3692 Email: [email protected] Applicant Company Name: Coppernic Address:20,rue Georges Claude Aix en Provence France 13290 Signature: Contact Person: Marc Piepers Tel:0033442652565 Email: [email protected]
Coppernic Agent Authorization Letter (2023-03-02) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park Sanwei, Xixiang, Bao'an District, Shenzhen, Guangdong, China Alex.li [email protected] to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Marc Piepers / Chief Technical Officer Date/City: 2023-03-02 / Aix en Provence Phone: 0033442652565 Fax: 0033442515732 E-mail: [email protected]
Coppernic Long Term Confidentiality Request Letter (2023-03-02) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product: access-ER HF ASK / access-ER HF ASK RCTIF Model: access-ER FCC ID: XGK-ACERASK To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the • Schematic Diagram • Block Diagram • Part List / BOM List / PCB Layout • Operational Description • Tune-up Procedure • FCC Software Security Requirements for UNII devices Required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Please contact me if there is any information you may need. Sincerely, Marc Piepers / Chief Technical Officer Date/City: 2023-03-02 / Aix en Provence Phone: 0033442652565 Fax: 0033442515732 E-mail: [email protected]
Coppernic Short Term Confidentiality Request Letter (2023-03-02) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For Product: access-ER HF ASK / access-ER HF ASK RCTIF Model: access-ER FCC ID: XGK-ACERASK To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, < Coppernic >. requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which < Coppernic > considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, < Coppernic > feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Marc Piepers / Chief Technical Officer Date/City: 2023-03-02 / Aix en Provence Phone: 0033442652565 Fax: 0033442515732 E-mail: [email protected]
ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12
ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 NFC ANT Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14 Photo 15 Photo 16 Photo 17 Photo 18 Photo 19 Photo 20 Photo 21 Photo 22 GSM/WCDMA/LTE Main ANT Photo 23 Photo 24 LTE AUX ANT BT/WIFI ANT
Page 1 of 227 Report No.: S22101403910001 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 Product Name: access-ER HF ASK / access-ER HF ASK RCTIF Trademark: COPPERNIC Model Name: access-ER Family Model: N/A FCC ID: XGK-ACERASK Report No.: S22101403910001 Prepared for Coppernic 20,rue Georges Claude Aix en Provence France 13290 Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen 518126 P.R.China. Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Page 2 of 227 Report No.: S22101403910001 TEST RESULT CERTIFICATION Applicant’s name .................. : Coppernic Address .................................. : 20,rue Georges Claude Aix en Provence France 13290 Manufacturer's Name ........... : Askey Computer Corp. Address .................................. : 10F, No.119, JianKang RD.,Zhonghe Dist.,New Taipei City,23585 Taiwan,R.O.C Taiwan Product description Product name ......................... : access-ER HF ASK / access-ER HF ASK RCTIF Trademark ............................ : COPPERNIC Model Name ......................... : access-ER Family Model .......................... : N/A Standards .............................. : FCC 47 CFR Part 2(2.1093); ANSI/IEEE C95.1-1992 IEEE Std 1528-2013; Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093) and ANSI/IEEE C95.1-1992. The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number .............................. S221014039011 Date of Test Date (s) of performance of tests ............. : Oct. 20, 2022 ~ Nov. 02, 2022 Date of Issue .......................................... : Jan. 07, 2023 Test Result .............................................. : Pass Prepared By (Test Engineer) : (Jacob Chen) Approved By (Lab Manager) : (Alex Li) Page 3 of 227 Report No.: S22101403910001 ※ ※ Revision History ※ ※ REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Jan. 07, 2023 Jacob Chen Page 4 of 227 Report No.: S22101403910001 TABLE OF CONTENTS 1. General Information ............................................................................................ 6 1.1. RF exposure limits .................................................................................... 6 1.2. Statement of Compliance ........................................................................ 7 1.3. EUT Description ....................................................................................... 7 1.4. Test specification(s) .................................................................................. 9 1.5. Ambient Condition ................................................................................... 9 2. SAR Measurement System ................................................................................. 10 2.1. SATIMO SAR Measurement Set-up Diagram .......................................... 10 2.2. Robot ..................................................................................................... 11 2.3. E-Field Probe .......................................................................................... 12 2.3.1. E-Field Probe Calibration ................................................................. 12 2.4. SAM phantoms ...................................................................................... 13 2.4.1. Technical Data .................................................................................. 14 2.5. Device Holder ........................................................................................ 15 2.6. Test Equipment List ................................................................................ 16 3. SAR Measurement Procedures .......................................................................... 18 3.1. Power Reference ................................................................................... 18 3.2. Area scan & Zoom scan .......................................................................... 18 3.3. Description of interpolation/extrapolation scheme .............................. 20 3.4. Volumetric Scan ..................................................................................... 20 3.5. Power Drift ............................................................................................ 20 4. System Verification Procedure .......................................................................... 21 4.1. Tissue Verification ................................................................................. 21 4.1.1. Tissue Dielectric Parameter Check Results ...................................... 22 4.2. System Verification Procedure .............................................................. 23 4.2.1. System Verification Results .............................................................. 24 5. SAR Measurement variability and uncertainty .................................................. 25 5.1. SAR measurement variability ................................................................. 25 5.2. SAR measurement uncertainty .............................................................. 25 6. RF Exposure Positions ...................................…
Text truncated - open the document above for the full version.
Page 131 of 227 Report No.: S22101403910001 Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.5084 0.4592 0.3889 0.3185 0.2583 0.2067 0.1705 3D screen shot Hot spot position Page 132 of 227 Report No.: S22101403910001 MEASUREMENT 16 Date of measurement: 20/10/2022 A. Experimental conditions. Area Scan dx=15mm dy=15mm, h= 5.00 mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE band 26b Channels Middle Signal LTE (Crest factor: 1.0) ConvF 1.50 B. SAR Measurement Results Frequency (MHz) 831.500000 Relative permittivity (real part) 41.218994 Relative permittivity (imaginary part) 19.814581 Conductivity (S/m) 0.915324 Variation (%) -1.030000 SURFACE SAR VOLUME SAR Maximum location: X=9.00, Y=3.00 SAR Peak: 0.57 W/kg SAR 10g (W/Kg) 0.381168 SAR 1g (W/Kg) 0.481761 Page 133 of 227 Report No.: S22101403910001 Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.5500 0.4879 0.4085 0.3330 0.2658 0.2128 0.1694 3D screen shot Hot spot position Page 134 of 227 Report No.: S22101403910001 MEASUREMENT 17 Date of measurement: 27/10/2022 A. Experimental conditions. Area Scan dx=12mm dy=12mm, h= 5.00 mm ZoomScan 7x7x7,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Body Band LTE band 41 Channels Middle Signal LTE (Crest factor: 1.6) ConvF 1.87 B. SAR Measurement Results Frequency (MHz) 2593.000000 Relative permittivity (real part) 37.603531 Relative permittivity (imaginary part) 13.223969 Conductivity (S/m) 1.904986 Variation (%) -1.000000 SURFACE SAR VOLUME SAR Maximum location: X=-17.00, Y=-12.00 SAR Peak: 1.11 W/kg SAR 10g (W/Kg) 0.249766 SAR 1g (W/Kg) 0.577341 Page 135 of 227 Report No.: S22101403910001 Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 1.1046 0.6403 0.3014 0.1331 0.0640 0.0363 0.0215 3D screen shot Hot spot position Page 136 of 227 Report No.: S22101403910001 14. Appendix D. Calibration Certificate Table of contents E Field Probe - SN 08/16 EPGO287 750 MHz Dipole - SN 03/15 DIP 0G750-355 835 MHz Dipole - SN 03/15 DIP 0G835-347 1800 MHz Dipole - SN 03/15 DIP 1G800-349 1900 MHz Dipole - SN 03/15 DIP 1G900-350 2450 MHz Dipole - SN 03/15 DIP 2G450-352 2600 MHz Dipole - SN 03/15 DIP 2G600-356 5000-6000 MHz Dipole - SN 13/14 WGA 33 Extended Calibration Certificate Page 137 of 227 Report No.: S22101403910001 Page 138 of 227 Report No.: S22101403910001 Page 139 of 227 Report No.: S22101403910001 Page 140 of 227 Report No.: S22101403910001 Page 141 of 227 Report No.: S22101403910001 Page 142 of 227 Report No.: S22101403910001 Page 143 of 227 Report No.: S22101403910001 Page 144 of 227 Report No.: S22101403910001 Page 145 of 227 Report No.: S22101403910001 Page 146 of 227 Report No.: S22101403910001 Page 147 of 227 Report No.: S22101403910001 Page 148 of 227 Report No.: S22101403910001 Page 149 of 227 Report No.: S22101403910001 Page 150 of 227 Report No.: S22101403910001 Page 151 of 227 Report No.: S22101403910001 Page 152 of 227 Report No.: S22101403910001 Page 153 of 227 Report No.: S22101403910001 Page 154 of 227 Report No.: S22101403910001 Page 155 of 227 Report No.: S22101403910001 Page 156 of 227 Report No.: S22101403910001 Page 157 of 227 Report No.: S22101403910001 Page 158 of 227 Report No.: S22101403910001 Page 159 of 227 Report No.: S22101403910001 Page 160 of 227 Report No.: S22101403910001 Page 161 of 227 Report No.: S22101403910001 Page 162 of 227 Report No.: S22101403910001 Page 163 of 227 Report No.: S22101403910001 Page 164 of 227 Report No.: S22101403910001 Page 165 of 227 Report No.: S22101403910001 Page 166 of 227 Report No.: S22101403910001 Page 167 of 227 Report No.: S22101403910001 Page 168 of 227 Report No.: S22101403910001 Page 169 of 227 Report No.: S22101403910001 Page 170 of 227 Report No.: S22101403910001 Page 171 of 227 Report No.: S22101403910001 Page 172 of 227 Report No.: S22101403910001 Page 173 of 227 Report No.: S22101403910001 Page 174 of 227 Report No.: S22101403910001 Page 175 of 227 Report No.: S22101403910001 Page 176 of 227 Report No.: S22101403910001 Page 177 of 227 Report No.: S22101403910001 Page 178 of 227 Report No.: S22101403910001 Page 179 of 227 Report No.: S22101403910001 Page 180 of 227 Report No.: S22101403910001
Page 181 of 227 Report No.: S22101403910001 Page 182 of 227 Report No.: S22101403910001 Page 183 of 227 Report No.: S22101403910001 Page 184 of 227 Report No.: S22101403910001 Page 185 of 227 Report No.: S22101403910001 Page 186 of 227 Report No.: S22101403910001 Page 187 of 227 Report No.: S22101403910001 Page 188 of 227 Report No.: S22101403910001 Page 189 of 227 Report No.: S22101403910001 Page 190 of 227 Report No.: S22101403910001 Page 191 of 227 Report No.: S22101403910001 Page 192 of 227 Report No.: S22101403910001 Page 193 of 227 Report No.: S22101403910001 Page 194 of 227 Report No.: S22101403910001 Page 195 of 227 Report No.: S22101403910001 Page 196 of 227 Report No.: S22101403910001 Page 197 of 227 Report No.: S22101403910001 Page 198 of 227 Report No.: S22101403910001 Page 199 of 227 Report No.: S22101403910001 Page 200 of 227 Report No.: S22101403910001 Page 201 of 227 Report No.: S22101403910001 Page 202 of 227 Report No.: S22101403910001 Page 203 of 227 Report No.: S22101403910001 Page 204 of 227 Report No.: S22101403910001 Page 205 of 227 Report No.: S22101403910001 Page 206 of 227 Report No.: S22101403910001 Page 207 of 227 Report No.: S22101403910001 Page 208 of 227 Report No.: S22101403910001 Page 209 of 227 Report No.: S22101403910001 Page 210 of 227 Report No.: S22101403910001 Page 211 of 227 Report No.: S22101403910001 Page 212 of 227 Report No.: S22101403910001 Page 213 of 227 Report No.: S22101403910001 Page 214 of 227 Report No.: S22101403910001 Page 215 of 227 Report No.: S22101403910001 Page 216 of 227 Report No.: S22101403910001 Page 217 of 227 Report No.: S22101403910001 Page 218 of 227 Report No.: S22101403910001 Page 219 of 227 Report No.: S22101403910001 <Justification of the extended calibration> If dipoles are verified in return loss (<-20dB, within 20% of prior calibration for below 3GHz, and <-8dB, within 20% of prior calibration for 5GHz to 6GHz), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Head 750MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.80 - 56.4 - Mar. 01, 2021 -23.642 0.66 56.998 0.598 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 220 of 227 Report No.: S22101403910001 <Head 835MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -25.44 - 54.40 - Mar. 01, 2021 -25.803 1.43 54.492 0.092 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 221 of 227 Report No.: S22101403910001 <Head 1800MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -28.85 - 47.90 - Mar. 01, 2021 -28.545 1.06 47.809 0.091 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 222 of 227 Report No.: S22101403910001 <Head 1900MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -24.79 - 50.80 - Mar. 01, 2021 -24.518 1.10 50.516 0.284 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 223 of 227 Report No.: S22101403910001 <Head 2450MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.18 - 56.30 - Mar. 01, 2021 -23.39 0.91 56.342 0.042 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 224 of 227 Report No.: S22101403910001 <Head 2600MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -21.15 - 52.70 - Mar. 01, 2021 -21.248 0.46 53.053 0.353 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 225 of 227 Report No.: S22101403910001 <Head 5200MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -9.15 - 21.17 - Mar. 01, 2021 -9.1819 0.35 21.191 0.021 Feb. 28, 2022 The return loss is <-8dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 226 of 227 Report No.: S22101403910001 <Head 5400MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -13.75 - 68.57 - Mar. 01, 2021 -13.816 0.48 68.914 0.344 Feb. 28, 2022 The return loss is <-8dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 227 of 227 Report No.: S22101403910001 <Head 5600MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -16.65 - 35.76 - Mar. 01, 2021 -16.249 2.41 35.146 0.614 Feb. 28, 2022 The return loss is <-8dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data _______________________________________END _____________________________________
Report No.: S22101403909005 Version.1.2 Page 1 of 45 FCC RADIO TEST REPORT FCC ID: XGK-ACERASK Product: access-ER HF ASK / access-ER HF ASK RCTIF Trade Mark: COPPERNIC Model No.: access-ER Family Model: N/A Report No.: S22101403909005 Issue Date: Jan 07, 2023 Prepared for Coppernic 20,rue Georges Claude Aix en Provence France 13290 Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Report No.: S22101403909005 Version.1.2 Page 2 of 45 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULTS ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES ..................................................................................................................... 9 6 SETUP OF EQUIPMENT UNDER TEST ......................................................................................................... 10 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ..................................................................... 10 6.2 SUPPORT EQUIPMENT ............................................................................................................................... 11 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 12 7 TEST REQUIREMENTS .................................................................................................................................... 13 7.1 FIELD STRENGTH OF SPURIOUS RADIATION ...................................................................................... 13 7.2 EFFECTIVE RADIATED POWER AND EFFECTIVE ISOTROPIC RADIATED POWER ........................ 24 7.3 CONDUCTED OUTPUT POWER ................................................................................................................ 30 7.4 FREQUENCY STABILITY ........................................................................................................................... 32 7.5 PEAK-TO-AVERAGE RATIO ...................................................................................................................... 39 7.6 26DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ..................................................................... 41 7.7 CONDUCTED BAND EDGE ....................................................................................................................... 43 7.8 CONDUCTED SPURIOUS EMISSION AT ANTENNA TERMINAL ......................................................... 44 Report No.: S22101403909005 Version.1.2 Page 3 of 45 1 TEST RESULT CERTIFICATION Applicant’s name ......................... : Coppernic Address ....................................... : 20,rue Georges Claude Aix en Provence France 13290 Manufacturer's Name .................. : Askey Computer Corp. Address ....................................... : 10F, No.119, JianKang RD.,Zhonghe Dist.,New Taipei City,23585 Taiwan,R.O.C Taiwan Product description Product name .............................. : access-ER HF ASK / access-ER HF ASK RCTIF Model and/or type reference ...... : access-ER Family Model ............................... : N/A Sample number S221014039010 Measurement Procedure Used: APPLICABLE STANDARDS APPLICABLE STANDARD/ TEST PROCEDURE TEST RESULT 47 CFR Part 2, Part 22H, Part 24E, Part 27 ANSI/TIA-603-E-2016 FCC KDB 971168 D01 Power Meas License Digital Systems v03 ANSI C63.26:2015 Complied This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing Technology Co., Ltd., this document may be altered or revised by Shenzhen NTEK Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. The test results of this report relate only to the tested sample identified in this report. Date of Test : Oct 17, 2022 ~ Jan 03, 2023 Testing Engineer : (Allen Liu) Authorized Signatory : (Alex Li) Report No.: S22101403909005 Version.1.2 Page 4 of 45 2 SUMMARY OF TEST RESULTS FCC Part22H / FCC Part24E / FCC Part 27 & ANSI C63.26-2015 FCC Rule Test Item Verdict Remark 2.1046 Conducted Output Power PASS Sub clause 5.2.3.4 of ANSI C63.26-2015 Peak-to-Average Ratio PASS 2.1049 22.917 Occupied Bandwidth PASS 2.1051 22.917 24.238 27.53 Band Edge PASS 22.913 Effective Radiated Power PASS 2.1053 22.917 24.238 27.53 Field Strength of Spurious Radiation PASS 2.1055 22.355 24.235 …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 23 | 27 | 2.50 GHz - 2.69 GHz | 159.59 mW | 17M9W7D | 0.00413 ppm |

access-ER HF/LF/BT HID CK
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
access-ER HF NFC/FAP30
Equipment Class
PCT - PCS Licensed Transmitter worn on body
C-One HF iClass / LF Prox
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
C-One2 HF ASK
Equipment Class
DTS - Digital Transmission System
C-One2 LF AGRIDENT
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter