WiMAX RNU4000BS Base Station User Manual 'RF5XQFRP518%68VHU0DQXDO5130*9 Preface Material RNU4000BS User Manual ʡ Runcom Technologies Ltd. About this Guide 7KLV8VHU0DQXDOGHVFULEHVWKHSURFHGXUHVIRUFRPPLVVLRQLQJPRXQWLQJLQVWDOOLQJDQGPDQDJLQJWKH 518%6%DVH6WDWLRQ Notice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afety Precautions 7RDYRLGLQMXU\DQGWRSUHYHQWHTXLSPHQWGDPDJHREVHUYHWKHVDIHW\SUHFDXWLRQVEHORZ x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x $OZD\VREVHUYHVWDQGDUGVDIHW\SUHFDXWLRQVGXULQJLQVWDOODWLRQRSHUDWLRQDQG PDLQWHQDQFHRIWKLVSURGXFW x 7KLVHTXLSPHQWPXVWEHLQVWDOOHGDFFRUGLQJWRFRXQWU\QDWLRQDOHOHFWULFDOFRGHV x $Q\FKDQJHVDQGPRGLILFDWLRQVWRWKHGHYLFHDQGWKHDFFHVVRULHVPXVWEHDSSURYHGE\ 5XQFRP x $OOHTXLSPHQWDQGDFFHVVRULHVPXVWEHLQVWDOOHGLQDUHVWULFWHGDFFHVVDUHD x 2EVHUYHDOOWKHODEHOVRQWKHHTXLSPHQWSURYLGLQJRSHUDWLRQGHWDLOVDQGZDUQLQJV x 5HDGDQGIROORZWKHLQVWDOODWLRQLQVWUXFWLRQVSURYLGHGLQWKLVPDQXDO x 7KHRXWGRRUEDVHVWDWLRQVKRXOGEHSRVLWLRQHGPRUHWKDQPHWHUVIURPKXPDQV x ,QFDVHRIXVLQJFDEOHVWKDWDUHQRWSURYLGHGZLWKWKHHTXLSPHQWSDFNDJHHQVXUHWKHVH FDEOHVFRPSO\ZLWKWKHUHJXODWRU\LQVSHFWLRQDXWKRULWLHVDQGDUHWKHUHVSRQVLELOLW\RIWKH FXVWRPHU x 'RQRWPRYHRUVKLSHTXLSPHQWXQOHVVLWLVSURSHUO\SDFNHGLQLWVRULJLQDOZUDSSLQJDQG VKLSSLQJFRQWDLQHUV Electrical Shock Prevention x :KHQFRQQHFWLQJHTXLSPHQWWRWKH$&DQG'&YROWDJHVXSSOLHVHQVXUHSURSHUSRODULW\ x 'LVFRQQHFWWKHSRZHUVRXUFHEHIRUHLQVWDOOLQJRUPDLQWDLQLQJWKHSRZHUZLULQJ x 'RQRWRSHUDWHWKHHTXLSPHQWLIWKHUHLVDQ\IDLOXUHRUGDPDJHWR HOHFWULFDO FRPSRQHQWV x 'RQRWWRXFKH[SRVHGFRQQHFWLRQVFRPSRQHQWVRUZLULQJZKHQSRZHULVRQ RNU4000BS User Manual Preface Material Runcom Technologies Ltd. L ʢ x ,QVWDOOWKHHTXLSPHQWDQGWKHJURXQGHG'&VXSSO\FLUFXLWVLQDGMDFHQWFDELQHWV x 3URWHFWWKH'&SRZHUVRXUFHZLWKDQDGMDFHQWFLUFXLWEUHDNHU x 7KHHTXLSPHQWPXVWEHSURSHUO\JURXQGHGEHIRUHDWWHPSWLQJWRRSHUDWHRUSHUIRUPDQ\ UHSDLUV RF Exposure 7RDYRLG5)H[SRVXUH,QVWDOODWLRQRIDQWHQQDVPXVWFRPSO\ZLWKWKH)&&5)H[SRVXUH UHTXLUHPHQWV Radio Interference 7KLVHTXLSPHQWJHQHUDWHVDQGUDGLDWHVUDGLRIUHTXHQF\HQHUJ\DQGLIQRWLQVWDOOHGDQGXVHG LQDFFRUGDQFHZLWKWKHLQVWUXFWLRQPDQXDOPD\FDXVHLQWHUIHUHQFHWRUDGLRFRPPXQLFDWLRQV 7RDYRLGLQWHUIHUHQFHV x $YRLGFRQMXQFWLRQZLWKDQ\RWKHUDQWHQQDRUWUDQVPLWWHU x ,QFDVHRI5DGLR,QWHUIHUHQFH5HORFDWHWKHDQWHQQDDQG,QFUHDVHVHSDUDWLRQEHWZHHQ WKHHTXLSPHQWDQGWKHUHFHLYHU HJFRQQHFWWRDVHSDUDWHFLUFXLWRURXWOHW x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ser Manual Table of Contents Runcom Technologies Ltd. ʤ Table of Contents 1Introducing the RNU4000BS BS ....................................................................................... 1 &RYHUDJH&RQILJXUDWLRQV 518%6,QWHUIDFHVDQG$FFHVVRULHV…
Text truncated - open the document above for the full version.
AW3054 698-806MHz, Dual Polarized 90° Sector Antennas Fixed Tilt This broadband Dual Polarized basestation antenna is designed for sectored applications offering superior Azimuth and Elevation pattern control across the entire frequency band. These antennas are aesthetically pleasing while maintaining a rugged design. Features: Excellent Radiation Patterns Stable Gain across the band Electrical Specifications: Frequency Range: 698 MHz - 806 MHz Gain: 12.5 dBi Return Loss (VSWR): > 14dB (1.5:1) Polarisation: Dual Slant (+/-45°) Isolation >30dB Front to Back Ratio: >25dB Horizontal 3dB BW: 90° Vertical 3dB BW: 17° Upper Sidelobe Suppression: >18dB Power Handling: 300W Impedance: 50 Ω Electrical Downtilt: 4° Ground: DC Grounded Mechanical Specifications: Connectors: 2 x N Female Connector Location: Bottom Dimensions (LxWxD): 1220 x 300 x 150 mm Weight: 13Kg Radome: UV Stabilised Styrosun Environmental Ratings: Rated Wind Velocity 200 km/h (125mph) Lightening Protection: DC Grounded Mounting Options: Adjustable Mounting Kit (CL-V-104)
AW3052 698-806MHz, Dual Polarized 65° Sector Antennas Fixed Tilt This broadband Dual Polarized basestation antenna is designed for sectored applications offering superior Azimuth and Elevation pattern control across the entire frequency band. These antennas are aesthetically pleasing while maintaining a rugged design. Features: Excellent Radiation Patterns Stable Gain across the band Electrical Specifications: Frequency Range: 698 MHz - 806 MHz Gain: 13.5 dBi Return Loss (VSWR): > 14dB (1.5:1) Polarisation: Dual Slant (+/-45°) Isolation >30dB Front to Back Ratio: >25dB Horizontal 3dB BW: 65° Vertical 3dB BW: 17° Upper Sidelobe Suppression: >18dB Power Handling: 300W Impedance: 50 Ω Electrical Downtilt: 4° Ground: DC Grounded Mechanical Specifications: Connectors: 2 x 7/16 DIN Female Connector Location: Bottom Dimensions (LxWxD): 1220 x 300 x 150 mm Weight: 13Kg Radome: UV Stabilised Styrosun Environmental Ratings: Rated Wind Velocity 200 km/h (125mph) Lightening Protection: DC Grounded Mounting Options: Adjustable Mounting Kit (CL-V-104)
Declaration of Authorization We Name: Runcom Technologies Ltd. Address: 11 Moshe Levi street,UMI Building, 12th floor City: Rishon Lezion 75658 Country: Israel . Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel is authorized to apply for Certification of the following product(s): Product description: Base station operating in 700 MHz band. Type designation: RNU4000BS. Trademark: Runcom Pico Base Station . on our behalf. Date: February 21, 2013 City: Rishon Lezion.. Name: Yonatan Zvi Function: Hardware Team Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Runcom Technologies Ltd. Address : 11 Moshe Levi street,UMI Building, 12th floor City: Rishon Lezion 75658 Country: Israel To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: XYMPICO4A701WDC Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: February 21, 2013 Name and signature of applicant: Yonatan Zvi Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Page 1 of 1 25-Feb-2013 Statement FCC ID:XYMPICO4A701WDC DC voltages/currents supplied to elements of the final radio frequency amplifying device, Triquint P/N AP561-F, for normal operation over the power range: Vdc=12 V and Idc=480 mA. Sincerely, Yonatan Zvi Hardware Team Manager Runcom Technologies Ltd.
Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 1 of 5 EXTERNAL PHOTOGRAPHS This document contains 4 photographs Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 2 of 5 Photograph No.1 RNU4000BS pico base station top view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 3 of 5 Photograph No.2 Pico base station bottom view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 4 of 5 Photograph No.3 Pico base station side view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 5 of 5 Photograph No.4 Pico base station external antenna connectors view
Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 1 of 2 Label The labels shown below are affixed on the side panel of the Pico Base Station. The labels material is PVC with a permanent adhesive. Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 2 of 2 Label location Label with FCC ID:XYMPICO4A701WDC location.
Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 1 of 13 INTERNAL PHOTOGRAPHS This document contains 12 photographs Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 2 of 13 Photograph No.1 RNU4000BS pico base station internal view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 3 of 13 Photograph No.2 Pico base station cover internal view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 4 of 13 Photograph No.3 Pico base station internal close view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 5 of 13 Photograph No.4 Pico base station internal close view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 6 of 13 Photograph No.5 Pico base station case internal view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 7 of 13 Photograph No.6 Pico base station main PCB top view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 8 of 13 Photograph No.7 Pico base station main PCB second side view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 9 of 13 Photograph No.8 PCB second side view without RF modules Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 10 of 13 Photograph No.9 RF module top view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 11 of 13 Photograph No.10 RF module second side view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 12 of 13 Photograph No.11 Another RF module top view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 13 of 13 Photograph No.12 Another RF module second side view
Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 1 of 1 Environmental evaluation and exposure limit according to FCC CFR 47part 1, §1.1307, §1.1310 The calculation was done to confirm required safe distance for fixed device. Limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 700/1500 = 0.47 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4 r 2 , where P T is the maximum equivalent isotropically radiated power (EIRP). To convert the total ERP output power of 39.86 dBm* (including 11.35 dBd antenna gain and 6 dB beamforming factor) into EIRP the 2.15 dB was added: 39.86 dBm + 2.15 dB = 42.01 dBm, which is equal to 15885.5 mW. 39.86 dBm obtained at 740 MHz, CBW=10 MHz, 64QAM corresponds to the equivalent isotropically radiated power (EIRP) of The minimum safe distance “r”, where RF exposure does not exceed FCC permissible limit, is r = sqrt { P T / (Px4)} = sqrt {15885.5 / (0.47 x12.56)} = 51.9 cm ≈ 52 cm. General public cannot be exposed to dangerous RF level.
Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected] Page 1 of 88 Report ID: RUNRAD_FCC.24208_rev1.docx Date of Issue: 7-Mar-13 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 27 FOR: Runcom Technologies Ltd. Base station operating in 700 MHz band Model: Pico Base Station RNU4000BS P/N: PICO-O-700-M-4X1W FCC ID:XYMPICO4A701WDC This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: RUNRAD_FCC.24208_rev1.docx Date of Issue: 7-Mar-13 Page 2 of 88 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Ports and lines .............................................................................................................................................................. 5 6.3 Support and test equipment .......................................................................................................................................... 5 6.4 Changes made in EUT .................................................................................................................................................. 5 6.5 Test configuration .......................................................................................................................................................... 6 6.6 Transmitter characteristics ............................................................................................................................................ 7 7 Transmitter tests according to 47CFR part 27 ............................................................................................................... 8 7.1 Peak output power test .................................................................................................................................................. 8 7.2 Occupied bandwidth test ............................................................................................................................................. 37 7.3 Emission mask (band edge emissions) test ................................................................................................................ 43 7.4 Spurious emissions at RF antenna connector test ...................................................................................................... 53 7.5 Radiated spurious emission measurements ................................................................................................................ 61 7.6 Frequency stability test ................................................................................................................................................ 70 8 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 72 9 APPENDIX B Measurement uncertainties ................................................................................................................... 73 10 APPENDIX C Test facility description ......................................................................................................................... 74 11 APPENDIX D Specification references ....................................................................................................................... 74 12 APPENDIX E Test equipment correction factors ......................................................................................................... 75 13 APPENDIX F Abbreviations and acronyms ................................................................................................................. 88 Report ID: RUNRAD_FCC.24208_rev1.docx Date of Issue: 7-Mar-13 Page 3 of 88 1 Applicant information Client name: Runcom Technologies Ltd. Address: 11 Moshe Levi street, UMI Building, 12th floor, Rishon Lezion 75658, Israel Telephone: +972 3942 8866 Fax: +972 3952 8805 E-mail: [email protected] Contact name: Mr. Yonatan Zvi 2 Equipment under test attributes Product name: Base station operating in 700 MHz band Product type: Transceiver Model(s): Pico Base Station RNU4000BS Part number: PICO-O-700-M-4X1W Serial number: 0406D2207F009B1 Hardware version: Rev2.2 Software release: 03.30.53.01 Receipt date 2/12/2013 3 Manufacturer information Manufacturer name: Runcom Technologies Ltd. Address: 11 Moshe Levi street, UMI Building, 12th floor, Rishon Lezion 75658, Israel Telephone: +972 3942 8866 Fax: +972 3952 8805 E-Mail: [email protected] Contact …
Text truncated - open the document above for the full version.
Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 1 of 8 SETUP PHOTOGRAPHS This document contains 7 photographs Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 2 of 8 Photograph No.1 Peak output power, occupied bandwidth, emission mask measurement setup Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 3 of 8 Photograph No.2 Conducted spurious emissions measurement setup Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 4 of 8 Photograph No.3 Spurious emissions measurement setup in the anechoic chamber below 30 MHz Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 5 of 8 Photograph No.4 Spurious emissions measurement setup in the anechoic chamber in 30 -1000 MHz Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 6 of 8 Photograph No.5 Radiated emissions measurement setup in the anechoic chamber above 1 GHz Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 7 of 8 Photograph No.6 Setup for substitution ERP measurements of spurious, EUT close view Runcom Technologies Ltd. FCC ID:XYMPICO4A701WDC Page 8 of 8 Photograph No.7 Frequency stability measurement setup
Harakevet Industrial zone · Israel
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 27 | 707.5 MHz - 742.5 MHz | 144.00 mW | 5M00D7D | 2721 Hz |

Base Station
Equipment Class
WGF - White Space Device with Geo-location- Fixed
Pico Base station
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
OUTDOOR PICO BASE STATION 3.5 GHz
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
OUTDOOR PICO BASE STATION 2.5 GHz
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter