FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schneider Electric Industries France L'Isle d'Espagnac/
  3. Y7HZBRRC

Y7HZBRRCProgrammable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC

Schneider Electric Industries France L'Isle d'Espagnac
Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC - FCC ID Y7HZBRRC - Schneider Electric Industries France L'Isle d'Espagnac
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 06, 2026
Application Purpose
Original Equipment
Equipment Note
Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC
Frequency Range
2405.00000000 - 2405.00000000
Company
Schneider Electric Industries France L'Isle d'Espagnac
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HarmonyXB5RHarmonyWirelessPush Buttons ExpertInstructionSheet EIO0000000812.06 01/2026 www.se.com LegalInformation The informationprovidedin this documentcontainsgeneraldescriptions,technical characteristicsand/orrecommendationsrelatedto products/solutions. This documentis not intendedas a substitutefor a detailedstudy or operationaland site-specificdevelopmentor schematicplan. It is not to be used for determining suitabilityor reliabilityof the products/solutionsfor specificuser applications.It is the duty of any such user to performor have any professionalexpertof its choice (integrator, specifieror the like) performthe appropriateand comprehensiverisk analysis,evaluationand testingof the products/solutionswith respectto the relevant specificapplicationor use thereof. The AchneiderElectricbrandand any trademarksof AchneiderElectricAE and its subsidiariesreferredto in this documentare the propertyof AchneiderElectricAE or its subsidiaries.%ll other brandsmay be trademarksof their respectiveowner. This documentand its contentare protectedunderapplicablecopyrightlaws and providedfor informativeuse only. No part of this documentmay be reproducedor transmittedin any form or by any means(electronic,mechanical,photocopying, recording,or otherwise),for any purpose,withoutthe prior writtenpermissionof AchneiderElectric. AchneiderElectricdoes not grant any right or licensefor commercialuse of the documentor its content,exceptfor a non-exclusiveand personallicenseto consultit on an "as is" basis. AchneiderElectricreservesthe right to makechangesor updateswith respectto or in the contentof this documentor the formatthereof,at any time withoutnotice. To theextentpermitteDEyapplicaElelaFG noresponsiEilityorliaEilityis assumeDEySchneiDerElectricanDitssuEsiDiariesforanyerrorsoromissions intheinformationalcontentofthisDocumentGasFellasanynon-intenDeDuse ormisuseofthecontentthereof. TaEleof+ontents AafetyInformation.......................................................................................Q %boutthe Document...................................................................................L ybersecurity............................................................................................... ProductDefensein Depth........................................................................... PotentialMisksand ompensatingontrols............................................... AecureInstallationand Aecurityardening................................................ AecureDisposal....................................................................................... AchneiderElectricybersecurityAupportPortal......................................... armony8LMIntroduction...................................................................- /eneralPresentationof armony8LM....................................................- Presentationof armony8LMMeadyto 2se Packages.............................L Presentationof 8LMomponents............................................................& Installation.................................................................................................. /eneralInstallationInstructionfor armony8LM...................................... (8M%-Passive%ntenna...........................................................................- Transmitterand Pushbutton%ssembly.......................................................Q 5ountingData for Mope Pull Awitch........................................................... 5ountingInstructionsfor (8M5;andy8ox............................................-; 5ountingInstructionsfor (8M5/(8M55obile8oxes..........................- 5ountinginstructions>or (8M%Aolder.................................................- Meceiver%ssemblyand Disassembly.........................................................-- Meceiver*iringDiagram..........................................................................-F Melay%ntennaInstallation.........................................................................-F Preparing>or 2se.....................................................................................Q- ompatibilityMules...................................................................................Q- TransmitterTypes.....................................................................................Q- LED Atatus...............................................................................................QQ Outputmodes..........................................................................................QL hangingoutputsfrom 5onostableto 8istablefor (8MM%...........................Q hangingOutputs>rom 5onostableto Disable/Enablefor (8MM%..............L; ow to Teach/2nteach5onostable,8istableor 5omentaryOutputsfor (8MM%,and (8MM................................................................................L ow to Teach Disable/EnableOutputsfor (8MM%.......................................LQ Lock/2nlockfor (8MM%and (8MM..........................................................LF Other>unctionsfor armony8LM......................................................L Other>unctionsDescription......................................................................L EIO;;;;;;;8.;&- SafetyInformation ImportantInformation Mead theseinstructionscarefully, and look at the equipmentto becomefamiliar with the devicebeforetryingto install,operate,service,or maintainit. The followingspecialmessagesmay appearthroughoutthis documentationor on the equipmentto warn of potentialhazardsor to call attentionto informationthat clarifiesor simplifiesa procedure. Please,ote Electricalequipmentshouldbe installed,operated,serviced,and maintainedonly by qualifiedpersonnel.No responsibilityis assumedby AchneiderElectricfor any consequencesarisingout of the use of this material. % qualifiedpersonis one who has skills and knowledgerelatedto the construction and operationof electricalequipmentand its installation,…

Text truncated - open the document above for the full version.

Attestation Statements

iCertifi Control Number - IC2026ASOP12279 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04/01/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: Y7HZBRRC Schneider Electric Industries France certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi is our designated U.S. agent for service of process for the above referenced FCC ID. Manufacturer accepts to maintain an agent for no less than two year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance Consulting LLC dba iCertifi FCC FRN: 0033399411 Address: 5809 US-2, Suite B, Albeni Plaza Priest River, Idaho 83856, United States Contact Person: Paul Preston Tel: +1 (866) 885-4575 Email: [email protected] Sincerely, Schneider Electric Industries France Americas Compliance Consulting LLC dba iCertifi FRN: 0019796176 FRN: 0033399411 HENCHOZ Marc Paul Preston [email protected] [email protected] +33631670416 +1 (866) 885-4575 Signature: Signature:

Attestation Statements

Rev 1/26/2023 General Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: May 1, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: Y7HZBRRC Schneider Electric Industries France (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Schneider Electric Industries France (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24- 886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Schneider Electric Industries France Marc HENCHOZ Signature: Rev 1/26/2023 General Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: May 1, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: Y7HZBRRC Schneider Electric Industries France (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Link: List of Equipment and Services Covered By Section 2 of The Secure Networks Act Sincerely, Schneider Electric Industries France Marc HENCHOZ Signature:

Cover Letter(s)

General Letter of Agency May 1, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 IIA Lab Services, LLC. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States We, the undersigned Schneider Electric Industries France hereby authorizes Majid MOURZAGH, LCIE SUD EST, to act on our behalf in all matters relating to all processes required for FCC certification of our devices. Any and all acts carried out by the above agent on our behalf shall have the same effects as acts of our own. This authorization is valid until: December 31th , 2026 If you have any questions regarding this authorization, let us know please. Sincerely, Marc HENCHOZ Signature:

Cover Letter(s)

General COVER LETTER Schneider Electric Industries France – ZBRRC-V2 FCC ID: Y7HZBRRC May 1, 2026 This report concerns: File : Original Grant SubPart: SubPart 15B and 15C Equipment type : Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC Request issue of grant : __ Immediately upon completion of review ___ Defer grant per 47 CFR 0.457(d)(1)(ii) until ____ date _____. Company Name agrees to notify the Commission by _____date_____ of the intended date of announcement of the product so that the grant can be issued on that date. Confidentiality of grant : __ Applicant requests the existence of this grant to be kept confidential until ____date____. The announcement of this product before this date via freedom of information would be detrimental to Company Name, and therefore must be considered a business secret. Public announcement of this product will not be made prior to this date. (Max. 60 days after grant issued). Limits used : (check one) CISPR 22: ______ Part15: ______ Measurement procedure used is ANSI C63.4-2014 / C63.10-2013 unless another is specified. Other test procedure : ____________________________________________________ Application for verification Applicant for this device Prepared by : Majid MOURZAGH LCIE Sud-Est ZI Centr’Alp – 170, rue de Chatagnon 38430 MOIRANS - France Ph. : 33 4 76 07 36 36 Fax : 33 4 76 55 90 88 e-mail : [email protected] FRN : 0005-0971-18 Marc HENCHOZ Schneider Electric Industries France BP 660 - ZI No.3 16340 - L'ISLE D'ESPAGNAC - France Ph. : +33631670416 Fax : +33545372031 e-mail: [email protected] FRN : 0019796176 Signature : Signature : *Not to be filed with Equipment Authorization Branch of FCC unless requested Report format prepared by the Information Technology Industry Council (ITI) ESC-5 and reviewed by FCC staff in 1994

Cover Letter(s)

General CONFIDENTIALITY REQUEST To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: IIA Lab Services, LLC. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States May 1, 2026 Subject: Confidentiality request FCC ID: Y7HZBRRC Schneider Electric Industries France requests, pursuant to 47CFR 0.457 and 0.459, post grant confidentiality for portions of the material contained in this application. The following document regarding this submission for FCC ID: Y7HZBRRC shall be kept confidential: LONG-TERM CONFIDENTIALITY: 1. Block Diagram description of the equipment (file: Block Diagram - Y7HZBRRC.pdf) 2. Schematic Diagram of the equipment (file: Schematic -Y7HZBRRC.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Responsible party: Marc HENCHOZ Title: Product Certification Manager Signature:

External Photos

LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/3 EXTERNAL PHOTOS OF EQUIPMENT FCCID: Y7HZBRRC LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/3 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/3

ID Label/Location Info

LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/2 PRODUCT LABELING FCCID: Y7HZBRRC LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 2/2 Label location

Internal Photos

LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/3 INTERNAL PHOTOS OF EQUIPMENT FCCID: Y7HZBRRC LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/3 RF ANTENNA LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/3

RF Exposure Info

LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE FCCID: Y7HZBRRC According to KDB 447498 D01 General RF Exposure Guidance v06 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Limit for General Population/ Uncontrolled Exposure : 47 CFR 1.1310 where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Prediction Frequency MHz Conducted Output Power dBm Max Antenna Gain dBi Distance cm Power Density mW/cm2 Limit mW/cm2 2405 5.14 3 20 0.0013 1.00 2440 5.02 3 20 0.0013 1.00 2480 4.83 3 20 0.0012 1.00 Conclusion: Therefore our device complies with FCC’s RF radiation exposure limits for general population without SAR evaluation with at least 20cm separation from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Test Report

Template : April 2 nd , 2025 Reproduction of this document is only authorized in its complete form. Any partial reproduction or any insertion of results in an accompanying text with a view to their distribution must receive prior and formal agreement from LCIE. This document results from tests carried out on a specimen, sample or test piece. It does not prejudge the conformity of all the products manufactured to the object tested. Unless otherwise indicated or rule specified by the test method, the decision of conformity does not take into account measurement uncertainty. It in no way prejudges a certification decision. The accreditation of the COFRAC Testing Section attests to the technical competence of the laboratories for the tests covered by the accreditation only. If certain tests mentioned in this report were carried out outside the framework of COFRAC accreditation, they are identified by the symbol . LCIE Laboratoire Central des Industries Electriques Une société Bureau Veritas Z.I Centr'alp 170, Rue de Chatagnon 38430 Moirans FRANCE Tél. + 33 4 76 07 36 36 [email protected] www.lcie.fr SAS au capital de 15 745 984€ / RCS Nanterre B 408 363 174 / N° TVA intracommunautaire FR01 408 363 174 / N°SIRET 408 363 174 00017 Accreditation N°1-7429 Scope available on www.cofrac.fr TEST REPORT N°: 26066893 -810930-B(FILE# 9068101) Version: 01 Subject Radio spectrum tests according to the standards: FCC CFR 47 Part 15.247 & ANSI C63.10 RSS-247 & RSS-Gen Issued to SCHNEIDER ELECTRIC INDUSTRIES FRANCE L'ISLE D'ESPAGNAC BP 660 - ZI No.3 16340 – L'ISLE D'ESPAGNAC FRANCE Apparatus under test  Product Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC  Trade mark Schneider Electric  Manufacturer Schneider Electric  Model under test ZBRRC-V2  Serial number 231503099  FCCID Y7HZBRRC  IC 7002C-ZBRRC Conclusion See Test Program chapter Test date August 20, 2025 to September 17, 2025 Test location LCIE Grenoble FCC Test site FR0008 - 918017 (MOI) ISED Test site 6500A – FR0008 (MOI) Sample receipt date August 20, 2025 Composition of document 53 pages Document issued on October 01, 2025 Written by : Approved by : Majid MOURZAGH Anthony MERLIN Tests operator Technical manager TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 2/53 PUBLICATION HISTORY Version Date Author Modification 01 October 01, 2025 Majid MOURZAGH Creation of the document Each new edition of this test report replaces and cancels the previous edition. The control of the old editions of report is under responsibility of client. TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 3/53 SUMMARY 1. TEST PROGRAM ............................................................................................................................. 4 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) .............................. 5 3. OCCUPIED BANDWIDTH ............................................................................................................... 12 4. 6DB BANDWIDTH .......................................................................................................................... 16 5. MAXIMUM CONDUCTED OUTPUT POWER ................................................................................. 20 6. POWER SPECTRAL DENSITY ...................................................................................................... 24 7. UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS ..................................... 29 8. UNWANTED EMISSIONS IN RESTRICTED FREQUENCY BANDS .............................................. 37 9. UNCERTAINTIES CHART .............................................................................................................. 52 TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 4/53 1. TEST PROGRAM References ➢ 47 CFR Part 15.247 (August 20, 2025) ➢ RSS 247 Issue 4 ➢ RSS Gen Issue 5 ➢ KDB 558074 D01 DTS Meas Guidance v05r02 ➢ KDB 662911 D01 Multiple Transmitter Output v02r01 ➢ ANSI C63.10 (2013) Radio requirement: Clause - Test Description Test result - Comments Occupied Bandwidth ISED PASS 6dB Bandwidth FCC & ISED PASS Maximum Conducted Output Power FCC & ISED PASS Power Spectral Density FCC & ISED PASS Unwanted Emissions in Non-Restricted Frequency Bands FCC & ISED PASS Unwanted Emissions in Restricted Frequency Bands FCC & ISED PASS Receiver Radiated Emissions ISED PASS(2) This table is a summary of test report, see conclusion of each clause of this test report for detail. (1) Limited program (2) Testing covered the receive mode, and receiver spurious emissions are considered to be the same as transmitter. PASS: EUT complies with standard’s requirement FAIL: EUT does not comply with standard’s requirement NA: Not Applicable NP: Test Not Performed TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 5/53 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) 2.1. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES): Equipment under test (EUT): Model under test: ZBRRC-V2 Serial Number: 231503099 Dimensions: 108mm x 36mm x 74.5mm (Length x Width x Height) Type: Panel / Rack / Cabinet (considered like table-top) Power supply: Name Type Rating Reference / Sn Comments Supply1 DC 24Vdc / / NC: Not communicated by provider TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 6/53 Inputs/outputs - Cable: Access Type Length used (m) Declared <3m Shielded Comments Supply1 2 wires 5 No No / NC: Not communicated by provider Auxiliary equipment used during test: Type Reference Sn Comments Laptop Lenovo L490 / To set configuration mode NC: Not communicated by provider TEST REPORT N°26066893 -810930-B(FILE# 9068101) Version : 01 Page 7/53 Equipment information (declaration of provider): 802.15.4: ZigBee Chipset / RF Module EFR32MG24A010F1536IM40-BR Frequency band: [2400 – 2483.5] MHz Spectrum Modulation: DSSS Number of Channel: 16 Spacing channel: 5MHz Channel bandwidth: 2MHz Antenn…

Text truncated - open the document above for the full version.

Test Report

INT_25-84-3_00 Schneider Electric Industries SAS L2A – Laboratoire Accrédité Angoulême ZI n°3, Boulevard Salvador Allende BP 660 – 16340 – L’ISLE D’ESPAGNAC – FRANCE Tel. +33 (0)5 79 89 01 00 SV_07-Rapport d'essai INTERNE_EN ied12.docx - PRO_07-001_FR Confidential Confidential Executive summary Gain= 3 dBi compliant to FCC and IC requirements Statement of conf ormity: Measured Requested by Managed by Written by Validated by UGHADE Akshit ashok EL AJMI Mohammed EL AJMI Mohammed EL AJMI Mohammed C&S PROJECT MANAGER Request ID: Visa : Visa : Industrial Automation L'ISLE D'ESPAGNAC France 25-84 Disclaimer This test report shall not be distributed and/or reproduced, except in full, without the written approval of our laboratory. The laboratory is not responsible for the information provided by the Applicant/Customer. This data is marked with symbol . This document is the result of a test performed on a specimen or sample of the product as received (i.e. the laboratory has not been responsible for the sampling stage and the sample has been provided by the Applicant/Customer). It does not provide an assessment of the conformity of all products manufactured from this Item Under Test (hereinafter referred to as “I.U.T.”). Some services reported are not covered by the laboratory accreditation. They are identified w ith the symbol *. Antennas caracterization, Gain and Radia- tion pattern Test Report INT_25-84-3_00 Issued on 2025-11-26 on Model / Type  ZBRRC Designation  Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, mono- stable, 24V DC Manuf acturer  Schneider Electric Region Of Interest [ROI]  Product Assigned Ratings  Gain under Normative ref erences : Method Code - Revision : Document was downloaded by HENCHOZ Marc for Restricted Use by SCHNEIDER ELECTRIC INDUSTRIES SAS on 2026-02-24 Schneider Electric – Test Report 2/9 INT_25-84-3_00 Schneider Electric Industries SAS L2A – Laboratoire Accrédité Angoulême ZI n°3, Boulevard Salvador Allende BP 660 – 16340 – L’ISLE D’ESPAGNAC – FRANCE Tel. +33 (0)5 79 89 01 00 SV_07-Rapport d'essai INTERNE_EN ied12.docx - PRO_07-001_FR Confidential Confidential 1 1.1 I.U.T. Description This table provides a detailed description of the Item Under Test (I.U.T.) and the specif ic area on which tests or analyses are f ocused - ref erred to as Region Of Interest (R.O.I.). It in- cludes identif ication details, origin, technical specif ication, manuf acturing, and delivery inf or- mation. Any other relevant inf ormation is also specif ied (e.g. variants tested, inf luencing vari- ables, sub-assemblies or accessories used). Note: The laboratory is not responsible for the information provided by the applicant. This data is marked with symbol . Item Ref erence Qty Item attributes Attribute value ZBRRC 1 Designation  Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24V DC Picture  Manufacturing [date]  2025 Manufacturing [place]  3K - France Maturity [level]  Preliminary production Delivery [date] 2025-11-17 1.2 Representative Sample No specif ic inf ormation was provided by the Applicant/Customer regarding the representa- tiveness of the tested ref erence in relation to other models or variants within the same prod- uct range or f amily. Theref ore, no extrapolation of the results can be assumed without clarif i- cation of its scope or additional validation. 1 Item Under Test Document was downloaded by HENCHOZ Marc for Restricted Use by SCHNEIDER ELECTRIC INDUSTRIES SAS on 2026-02-24 Schneider Electric – Test Report 3/9 INT_25-84-3_00 Schneider Electric Industries SAS L2A – Laboratoire Accrédité Angoulême ZI n°3, Boulevard Salvador Allende BP 660 – 16340 – L’ISLE D’ESPAGNAC – FRANCE Tel. +33 (0)5 79 89 01 00 SV_07-Rapport d'essai INTERNE_EN ied12.docx - PRO_07-001_FR Confidential Confidential 1.3 I.U.T. Setup This section describes how the I.U.T. was installed or prepared prior to and during the test execution. It includes details on the physical conf iguration of the item, any pre-conditioning steps, the integration of sub-assemblies or accessories. Note: This section focuses exclusively on the preparation, modifications, or specific configuration applied to the Item Un- der Test (I.U.T.) by the laboratory. • Test Set-up • Using EUT transmitter at desired channel and mounted on a 360 ° turntable o Maturo • Using a f ixed antenna as receiver • Distance between Antennas : 135 cm • Height Antennas : 160 cm • The Gain is measured in anechoic chamber • Prx : Received RF power • Ptx : Transmitted RF power • Receiver antenna : P8S-2400S (Mobilemark) • 2.4-2485 GHz • Gain=8 dBi Anechoic Chamber 135 cm 160 cm 360 ° Receiver Antenna EUT Spectral Analyzer Prx Document was downloaded by HENCHOZ Marc for Restricted Use by SCHNEIDER ELECTRIC INDUSTRIES SAS on 2026-02-24 Schneider Electric – Test Report 4/9 INT_25-84-3_00 Schneider Electric Industries SAS L2A – Laboratoire Accrédité Angoulême ZI n°3, Boulevard Salvador Allende BP 660 – 16340 – L’ISLE D’ESPAGNAC – FRANCE Tel. +33 (0)5 79 89 01 00 SV_07-Rapport d'essai INTERNE_EN ied12.docx - PRO_07-001_FR Confidential Confidential Figure 1 Set up Document was downloaded by HENCHOZ Marc for Restricted Use by SCHNEIDER ELECTRIC INDUSTRIES SAS on 2026-02-24 Schneider Electric – Test Report 5/9 INT_25-84-3_00 Schneider Electric Industries SAS L2A – Laboratoire Accrédité Angoulême ZI n°3, Boulevard Salvador Allende BP 660 – 16340 – L’ISLE D’ESPAGNAC – FRANCE Tel. +33 (0)5 79 89 01 00 SV_07-Rapport d'essai INTERNE_EN ied12.docx - PRO_07-001_FR Confidential Confidential 2 2.1 Test Configuration This section outlines the overall test conf iguration and contextual conditions under which the test was conducted. It includes an overview of the test setup and all necessary connections, supported by f igures, diagrams, and/or photographs. The objective is to document the pre- cise circumstances that def ine the test environment and ensure reproducibility. Note: Connections includes, but not limited to: - Electrical conne…

Text truncated - open the document above for the full version.

Test Setup Photos

LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/4 CONDUCTED AND RADIATED MEASUREMENT PHOTO FCCID: Y7HZBRRC 1.1 Conducted emission LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 2/4 1.2 Radiated emissions LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 3/4 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 4/4

Contact Information

Applicant

Marc HENCHOZ(Product Certification Manager)
[email protected]Fax: +33545372031

Technical Contact

Americas Compliance Consulting LLC dba iCertifiPaul Preston
[email protected]

5809 US-2, Suite B, Albeni Plaza · Priest River, Idaho, 83856 · United States

Test Firm

LCIE Etablissement Sud EstAnthony MERLIN
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.40 GHz3.27 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Other Applications from Schneider Electric Industries France L'Isle d'Espagnac

Configurable receiver, Harmony XB5R, 2 relays, 2 buttons, 6 indicating LEDs, monostable, bistable, stop start, 24...240V AC/DC - FCC ID Y7HZBRRA - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZBRRA

Configurable receiver, Harmony XB5R, 2 relays, 2 buttons, 6 indicating LEDs, monostable, bistable, stop start, 24...240V AC/DC

May 01, 2026

Equipment Class

DTS - Digital Transmission System
Ositrack RFID compact stations (ref ZB5SKR0...) is a range of short range devices with integrated antenna, operating with a carrier frequency of 13.56 MHz and designed for mounting through a 022 hole. - FCC ID Y7HZB5SK - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZB5SK

Ositrack RFID compact stations (ref ZB5SKR0...) is a range of short range devices with integrated antenna, operating with a carrier frequency of 13.56 MHz and designed for mounting through a 022 hole.

Jun 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ZART REMOTE use a Bluetooth module - FCC ID Y7HZART - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZART

ZART REMOTE use a Bluetooth module

Apr 29, 2014

Equipment Class

DTS - Digital Transmission System
ZARB BASE use a Bluetooth module - FCC ID Y7HZARB - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZARB

ZARB BASE use a Bluetooth module

Apr 27, 2014

Equipment Class

DTS - Digital Transmission System
Wireless and batteryless complete transmitter - FCC ID Y7HZBRT2 - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZBRT2

Wireless and batteryless complete transmitter

Dec 18, 2013

Equipment Class

DTS - Digital Transmission System