FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schneider Electric Industries France L'Isle d'Espagnac/
  3. Y7HZBRT2

Y7HZBRT2Wireless and batteryless complete transmitter

Schneider Electric Industries France L'Isle d'Espagnac
Wireless and batteryless complete transmitter - FCC ID Y7HZBRT2 - Schneider Electric Industries France L'Isle d'Espagnac
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 18, 2013
Application Purpose
Original Equipment
Date of Application
Dec 18, 2013
Equipment Note
Wireless and batteryless complete transmitter
Frequency Range
2405.00000000 - 2405.00000000
Company
Schneider Electric Industries France L'Isle d'Espagnac
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

S1A57198 05 10 - 2013 1/4 ZBpRTpppp / ZBRTp www.schneider-electric.com Models: ZBRT1, ZBRT2 and ZBRTP FCC USA and I C Canada Compliance Statement This device complies with part 15 of the FCC rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1). this device may not cause harmfulinterference, and (2). this device must accept any interference received, including interference that may cause undesired operation of the device. Note: Schneider Electric is not responsible for any radio or tv interference caused by unauthorized modifications to this equipment. Changes or modifications not expressly approved by Schneider Electric responsible for compliance could void the user’s authority to operate the equipment. 3a ZB5AZ905 2,2 Nm ±0,2 19.5 lb-in ±1.8 3a NOTE / NOTE / HINWEIS / NOTA : p Please note down and retain your transmitter's ID. You will need it for an ID Reset. p Veuillez noter et conserver l'ID de votre émetteur Il sera nécessaire en cas de Reset ID. p Notieren Sie sich bitte die ID Ihres Senders. Sie benötigen diese für einen ID-Reset. p Anote y guarde el ID del transmisor. Lo necesitará si hay que resetear el ID. 03 ZBRTp 2a 3a 4a 4b 3a 2a 1a ZB5Rppp Click! ID 4a ID ≥30(*) ≥1.18(*) ≥40(*) ≥1.57(*) Ø 22,3 Ø 0.88 +0,4 0 mm in. 1...6 0.04...0.24 Unmounting Démontage Demontage Desmontar Mounting Montage Montage Montar Unmounting Démontage Demontage Desmontar Mounting Montage Montage Montar ZBRTp 2b 3b 2b ZB4Rppp Click! 3b (*): Depends on the head type Dépend du type de tête Je nach Kopftyp Depende del tipo de cabezal 1b 4b ZBRTp Click! ZB5AZ009 1a1b ZBRTp Click! ZB4BZ009 WARNING / AVERTISSEMENT / WARNUNG / ADVERTENCIA FONCTIONNEMENT IMPREVU DE L'EQUIPE- MENT p N'utilisez pas cet équipement pour des fonctions sensibles sur le plan de la sécurité. p Lorsque des risques de blessures corporelles ou de dommages matériels existent, utilisez des verrous de sécurité appropriés. p Installez et utilisez cet équipement dans un boîtier ayant les caractéristiques nominales adaptées. Le non-respect de ces instructions peut provoquer la mort, des blessures graves ou des dommages matériels. FUNCIONAMIENTO INESPERADO DEL EQUIPO p No utilice este equipo en funciones de maquinaria críticas para la seguridad. p En caso de que exista riesgo para el personal o los equipos, utilice los dispositivos de bloqueo de seguridad adecuados. p Instale y utilice este equipo en una caja con capacidad adecuada para su entorno. Si no se siguen estas instrucciones pueden producirse lesiones personales graves o mortales o daños en el equipo. UNINTENDED EQUIPMENT OPERATION p Do not use this equipment in safety critical machine functions. p Use appropriate safety interlocks where personnel and/or equipment hazards exist. p Install and operate this equipment in an appropriately rated enclosure for its intended environment. Failure to follow these instructions can result in death, serious injury, or equipment damage. UNBEABSICHTIGTER BETRIEB VON GERÄTEN p Setzen Sie das Gerät nicht für sicherheitskri- tische Maschinenfunktionen ein. p Verwenden Sie geeignete Sicherheitssperren, wenn eine Gefahr für Personal und/oder Geräte gegeben ist. p Installieren und betreiben Sie das Gerät in einem Gehäuse mit geeigneter Spannung für die Zielumgebung. Die Nichtbeachtung dieser Anweisungen kann zu Tod, schwerer Körperverletzung oder Materialschäden führen. Scan the tag with your smartphone to access the Web site: Metal cabinet / Boîtier métallique / Metallschrank / Armario metálico Unobstructed / Champ libre / Nicht behindert / Sin obstrucción 2.405 GHz (IEEE 802.15.4) 2.405 GHz (IEEE 802.15.4) en frde es EIO0000000812 EIO0000000813 EIO0000000814 EIO0000000815 (*) : Typical values that may be modified by the application environment / Valeurs typiques pouvant être modifiées par l'environnement de l'application / Typische Werte, die von der Anwendungsumgebung geändert werden können / Valores típicos que pueden variar según el entorno de la aplicación a 25 m (*) a 82 ft (*) ZBRRp a 100 m (*) a 328.1 ft (*) ZBRRp Consult the Expert Instruction Sheet on: / Consulter l’Instruction de Service Expert sur : / Lesen Sie das Experten-Anweisungsblatt auf: / Consulte la hoja de instrucciones del experto en: www.schneider-electric.com S1A57198 05 10 - 2013 2/4 ZBpRTpppp / ZBRTp www.schneider-electric.com PWR Q1 Q2 OK PWR Q1 Q2 OK PWR Q1 Q2 Q3 Q4 Q3 Q4 OK PWR Q1 Q2 OK Q3 Q4 PWR Q1 Q2 Q3 Q4 Q3 Q4 OK PWR Q1 Q2 OK PWR Q1 Q2 Q3 Q4 OK x1 PWR Q1 Q2 OK PWR Q1 Q2 OK x 6 < 6s x 3 < 3s a3s 1 Exit? Q1 (Teach + 4s = Q1 active) x1 a3s 4 Hz2 Hz 2 Hz 1 2a 3a 1 Q2 (Teach + 4s => Q2 active) x1 4 Hz 4 Hz 2b PWR Q1 Q2 Q3 Q4 OK 1 Exit? Exit? PWR Q1 Q2 OK PWR Q1 Q2 Q3 Q4 Q3 Q4 Q3 Q4 Q3 Q4 OK 4 Hz 2 Hz ZBRRp (Teach only for monostable, bistable or set/reset outputs) PWR Q1 Q2 OK PWR Q1 Q2 Q3 Q4 Q3 Q4 OK x1 x 6 < 6s x 3 < 3s 2 Hz 3b 1 2 Exit? 1min 30s Exit 2 1min 30s Exit x1 1 Q3 Q4 Teach/Unteach / Apprentissage/Désapprentissage / Teach-In ausführen/aufheben / Aprendizaje/Desaprendizaje Unteach / Désapprentissage aufheben / Desaprendizaje Exit / Pour quitter / Ende / Salir OK 2 Monostable / Monostable / Monoflop / Monoestable Bistable / Bistable / Biflop / Biestable Stop/Start / Arrêt/Marche / Stopp/Start / Detener/Iniciar Flashing / Clignote / Blinken / Intermitencia Green ON / Allumée verte / Grün EIN / Verde encendido Yellow ON / Allumée jaune / Gelb EIN / Amarillo encendido Teach / Apprentissage / Teach-In ausführen / Aprendizaje Teach / Apprentissage / Teach-In ausführen / Aprendizaje Unteach / Désapprentissage aufheben / Desaprendizaje x 3 Incompatibility detected: ZBRT1+ZBRT2 same output S1A57198 05 10 - 2013 3/4 ZBpRTpppp / ZBRTp www.schneider-electric.com Models: ZBRT1, ZBRT2 and ZBRTP FCC USA and I C Canada Compliance Statement This device complies with part 15 of the FCC rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1). this device may not c…

Text truncated - open the document above for the full version.

Cover Letter(s)

Schneider Electric Industries SAS Postal address: Zone Industrielle BP 660 F – 16340 L’ISLE D’ESPAGNAC Tel. +33 (0)5 45 37 20 00 http://www.schneider-electric.com Société par Actions Simplifiée au capital de 896 313 776 euros - 954 503 439 rcs Nanterre Code APE : 312A - Siret : 954 503 439 01719 N° ident. TVA : FR 04 954 503 439 Siège social : 35 Rue Joseph Monier F- 92500 Rueil Malmaison Schneider Electric Industries SAS INDUSTRY BUSINESS – H2I - Control date: November 27, 2013 y. ref: o. ref: 135012 tel: +33 5 45 37 24 46 fax: +33 5 45 37 20 31 e-mail: [email protected] subject: Authority to act as agent Attn: TIMCO Engineering Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 On our behalf, I appoint M. Mathieu DUMESNIL from Emitech, Parc d'Activités de Lanserre - 21, rue de la Fuye – 49610 JUIGNE SUR LOIRE, FRANCE , to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by TIMCO Engineering Inc., still resides with Schneider Electric Industries SAS. This authorization is valid until further written notice from Schneider Electric Industries SAS. Sincerely, Jean-Pierre LAIDET In charge of Product Certification

Cover Letter(s)

Schneider Electric Industries SAS Postal address : Zone Industrielle BP 660 F – 16340 L’ISLE D’ESPAGNAC Tel. +33 (0)5 45 37 20 00 http://www.schneider-electric.com Société par Actions Simplifiée au capital de 896 313 776 euros - 954 503 439 rcs Nanterre Code APE : 312A - Siret : 954 503 439 01719 N° ident. TVA : FR 04 954 503 439 Siège social : 35 Rue Joseph Monier F- 92500 Rueil Malmaison subject: Confidentiality Request regarding application for certification of FCC ID: Y7HZBRT2 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (ie- Block Diagram, Schematics, Operational Description, Parts List, Tune Up Info) Transmitter ZBRT2 Schem.pdf Transmitter ZBRT2 PartsLst.pdf Transmitter ZBRT2 OpDes BlkDia.pdf (Note- If Internal Photos or the Users Manual are to be requested under Long-Term Confidentiality justification must be required per the FCC’s Confidentiality Policy.) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Jean-Pierre LAIDET In charge of Product Certification Federal Communications Commission Authorization and Evaluation Division Schneider Electric Industries SAS INDUSTRY BUSINESS – H2I - Control date: November 21, 2013 y. ref: o. ref: 135010 tel: +33 5 45 37 24 46 fax: +33 5 45 37 20 31 e-mail: [email protected]

ID Label/Location Info

Label location

Test Report

RR051-13-104633-2-A Ed. 0 RADIO test report According to the standard: CFR 47 FCC Part 15 Equipment under test: Batteryless, wireless button Model: ZBRT2 (Solo Up/Down) FCC ID: Y7HZBRT2 Company: SCHNEIDER ELECTRIC INDUSTRIE Distribution: Mr POUYOLLON (Company: SCHNEIDER ELECTRIC INDUSTRIE) Number of pages: 23 with 6 appendixes Technical Verification and Ed. Date Modified Written by Quality Approval pages Name Visa Name Visa 0 29/10/2013 Creation M. DUMESNIL Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. RR051-13-104633-2-A Ed. 0 Page 2 out of 23 DESIGNATION OF PRODUCT: Batteryless, wireless button Serial number (S/N): 3000266 Reference / model (P/N): ZBRT2 (Solo Up/Down) Software version: not communicated MANUFACTURER: SCHNEIDER ELECTRIC INDUSTRIE COMPANY SUBMITTING THE PRODUCT: Company: SCHNEIDER ELECTRIC INDUSTRIE Address: Boulevard Salvador Allende ZI d’Espagnac BP 660 16340 l’Isle d’Espagnac France Responsible: Mr POUYOLLON DATES OF TEST: 09 and 10 October 2013 TESTING LOCATION: EMITECH ANGERS laboratory at JUIGNE SUR LOIRE (49) FRANCE EMITECH ANGERS open area test site in JUIGNE SUR LOIRE (49) FRANCE 21 rue de la Fuye 49610 Juigne sur Loire France FCC 2.948 Listed Site Registration Number: 90469 TESTED BY: M. DUMESNIL RR051-13-104633-2-A Ed. 0 Page 3 out of 23 CONTENTS TITLE PAGE 1. INTRODUCTION ................................................................................................................................. 4 2. PRODUCT DESCRIPTION .................................................................................................................. 4 3. NORMATIVE REFERENCE ................................................................................................................. 4 4. TEST METHODOLOGY ....................................................................................................................... 5 5. TEST EQUIPMENT CALIBRATION DATES .......................................................................................... 6 6. TESTS AND CONCLUSIONS .............................................................................................................. 7 Intentional radiator (subpart C) ............................................................................................................. 7 7. ADDITIONAL PROVISIONS TO THE GENERAL RADIATED EMISSION LIMITATIONS .......................... 8 8. MAXIMUM PEAK OUTPUT POWER .................................................................................................... 9 9. INTENTIONAL RADIATOR ................................................................................................................ 11 10. PEAK POWER DENSITY ................................................................................................................. 13 APPENDIX 1: Photos of the equipment under test APPENDIX 2: Test set up APPENDIX 3: Test equipment list APPENDIX 4: 6 dB bandwidth APPENDIX 5: 20 dB bandwidth APPENDIX 6: Band edge RR051-13-104633-2-A Ed. 0 Page 4 out of 23 1. INTRODUCTION This report presents the results of radio test carried out on the following radio equipment: Batteryless,wireless button ‒ Model: ZBRT2 (Solo Up/Down), in accordance with normative reference. 2. PRODUCT DESCRIPTION ITU Emission code: 2M29GXW Class: B (residential environment) Utilization: Wireless batteryless complete transmitter Antenna type and gain: integrated PCB antenna, unknown gain Operating frequency range: 2405 MHz Number of channels: 1 Channel spacing: not concerned Frequency generation: crystal Modulation: QPSK Power source: 3 Vd.c for purpose of the tests but self-powered when user press the button in normal use Power level, frequency range and channels characteristics are not user adjustable. The details pictures of the product and the circuit boards are joined with this file. 3. NORMATIVE REFERENCE The standards and testing methods related throughout this report are those listed below. They are applied on the whole test report even though the extensions (version, date and amendment) are not repeated. CFR 47 FCC Part 15 (2013) Radio Frequency Devices ANSI C63.4 (2003) Methods of Measurement of Radio-Noise Emissions from Low-voltage Electrical and Electronics Equipment in the range of 9 kHz to 40 GHz. 558074 D01 DTS v03r01 Guidance for Performing Compliance on Digital Transmission Systems Operating under §15.247 RR051-13-104633-2-A Ed. 0 Page 5 out of 23 4. TEST METHODOLOGY Radio performance tests procedures given in CFR 47 part 15: Subpart B –Unintentional Radiators Paragraph 107: Conducted limits Paragraph 109: Radiated emission limits Subpart C – Intentional Radiators Paragraph 205: Restricted bands of operation Paragraph 207: Conducted limits Paragraph 209: Radiated emission limits; general requirements Paragraph 215: Additional provisions to the general radiated emission limitations Paragraph 247: Operation within the bands 902-928 MHZ, 2400-2483.5 MHz and 5725-5850 MHz RR051-13-104633-2-A Ed. 0 Page 6 out of 23 5. TEST EQUIPMENT CALIBRATION DATES Equipment Model Type Last verification Next verification Validity 0000 Software BAT-EMC / / / 1922 Microwave DB C020180F- 4B1 Low-noise amplifier 1 to 18 GHz 12/09/2013 12/09/2014 12/11/2014 1939 IMC WR42 Horn antenna 20/04/2012 20/04/2016 20/06/2016 1940 IMC WR42 Horn antenna 20/04/2012 20/04/2016 20/06/2016 2469 ODZ0004A-N Detector 02/08/2013 02/08/2015 02/10/2015 2593 B25250 Climatic chamber 07/08/2012 07/08/2014 07/10/2014 3036 ALC Microwave ALN02- 0102 Low-noise amplifier 04/04/2013 04/04/2014 04/06/2014 4088 R&S FSP40 Spectrum analyzer 22/08/2013 22/08/2015 22/10/2015 5625 BL Microwave BP2442-84- 7CS Band pass filter 24/01/2012 24/01/2014 24/03/2014 6384 Me…

Text truncated - open the document above for the full version.

Test Setup Photos

Test set up in anechoic room

Contact Information

Applicant

Jean-Pierre LAIDET(Product Certification Manager)
[email protected]+33545372446Fax: +33545372031

Test Firm

EMITECH ANGERSOlivier ROY
[email protected]33241575740Fax: 332413455577

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.40 GHz200.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Schneider Electric Industries France L'Isle d'Espagnac

Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC - FCC ID Y7HZBRRC - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZBRRC

Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24VDC

May 06, 2026

Equipment Class

DTS - Digital Transmission System
Configurable receiver, Harmony XB5R, 2 relays, 2 buttons, 6 indicating LEDs, monostable, bistable, stop start, 24...240V AC/DC - FCC ID Y7HZBRRA - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZBRRA

Configurable receiver, Harmony XB5R, 2 relays, 2 buttons, 6 indicating LEDs, monostable, bistable, stop start, 24...240V AC/DC

May 01, 2026

Equipment Class

DTS - Digital Transmission System
Ositrack RFID compact stations (ref ZB5SKR0...) is a range of short range devices with integrated antenna, operating with a carrier frequency of 13.56 MHz and designed for mounting through a 022 hole. - FCC ID Y7HZB5SK - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZB5SK

Ositrack RFID compact stations (ref ZB5SKR0...) is a range of short range devices with integrated antenna, operating with a carrier frequency of 13.56 MHz and designed for mounting through a 022 hole.

Jun 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ZART REMOTE use a Bluetooth module - FCC ID Y7HZART - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZART

ZART REMOTE use a Bluetooth module

Apr 29, 2014

Equipment Class

DTS - Digital Transmission System
ZARB BASE use a Bluetooth module - FCC ID Y7HZARB - Schneider Electric Industries France L'Isle d'Espagnac
Y7HZARB

ZARB BASE use a Bluetooth module

Apr 27, 2014

Equipment Class

DTS - Digital Transmission System