
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Masterbuilt Manufacturing, Inc. 022311 – 6 Authority to Act as Agent Date: May 20, 2014 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: ______ Intertek Testing Services Shenzhen Ltd.Guangzhou Branch ______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: 12 months By: Darryl Kraft (Signature 1 ) (Print name) Title: Senior Quality Engineer On behalf of: Masterbuilt Manufacturing, Inc. (Company Name) Telephone: 706 256 3931 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Masterbuilt Manufacturing, Inc. 022311 – 6 Request for Confidentiality Date: ___May 20,2014_____ Subject: Confidentiality Request for: _____YHXESQ-3040C6 YHXESQ-3040R6____ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ ____ Masterbuilt Manufacturing, Inc._____ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180 ) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: Darryl Kraft Senior Quality Engineer 2 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details.
1 Masterbuilt Court · Columbus, Georgia 31907 · www.masterbuilt.com 1.800.489.1581 · 706.327.5622 · Fax 706.327.5632 FCC ID Label FCC ID: YHXESQ-3040C6 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 100MM 25MM
Report No: 140414100GZU-002 Issued: 16 June 2014 FCC ID: YHXESQ-3040C6 Page 2 of 23 CONTENT TEST REPORT ......................................................................................................................................... 1 CONTENT ................................................................................................................................................. 2 1. General Description ...................................................................................................................... 3 1.1 Product Description ......................................................................................................... 3 1.2 Related Submittal (s) / Grants ....................................................................................... 3 1.3 Test Methodology ............................................................................................................ 3 1.4 Test Facility ....................................................................................................................... 4 1.5 Measurement Uncertainty .............................................................................................. 5 2. System Test Configuration ........................................................................................................... 6 2.1 Justification ....................................................................................................................... 6 2.2 EUT Exercising Software ................................................................................................ 6 2.3 Special Accessories ........................................................................................................ 6 2.4 Equipment Modification .................................................................................................. 6 2.5 Support Equipment List and Description...................................................................... 6 3. Summary of Test Results .............................................................................................................. 7 3.1 Antenna Requirement ..................................................................................................... 7 3.2 Conducted Emission ....................................................................................................... 7 3.3 Radiated Emission ......................................................................................................... 11 3.4 Bandedges Measurement ............................................................................................ 16 4. Equipment List ............................................................................................................................ 23 Report No: 140414100GZU-002 Issued: 16 June 2014 FCC ID: YHXESQ-3040C6 Page 3 of 23 1. General Description 1.1 Product Description The Equipment Under Test (EUT) is a transceiver for Black Electric Smoker with RF at 2.440GHz. It is powered by AC mains:120V/60Hz. During normal use, it sends temperature information (probe) to remote control, when the “meat probe” button on remote control is pressed and receive control command (temp.and time) from remote control. Antenna Type: internal integrated antenna. The model: 20070312, 20072112, 20072212, 20072312, 20072412, 20072912, 20070512, 20072512, 20072612, 20072712, 20072812, 20073012 are the same in hardware and software aspect. The only differences are the appearance, and model no.for trading purpose. The power of 20070512, 20072512, 20072612, 20072712, 20072812, 20073012 is 1200W. The power of 20070312, 20072112, 20072212, 20072312, 20072412, 20072912 is 800W We tested the Black Electric Smoker, model:20070312, to determine if it was in compliance with the relevant FCC standards. We found that the unit met the requirements of FCC part 15.249. The worst case’s test data was presented in this test report. 1.2 Related Submittal (s) / Grants The FCC ID of corresponding transceiver for this transceiver is YHXESQ-3040R6. 1.3 Test Methodology Radiated emission measurements were performed according to the procedures in ANSI C63.10:2009. Radiated emission measurement was performed in semi-anechoic chamber room. For radiated emission measurement, preliminary scans were performed in the semi-anechoic chamber only to determine the worst case modes. All radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section" of this Application. Conducted emission test was performed according to ANSI C63.10: 2009. The EUT was set to achieve the maximum emission level. The mains terminal disturbance voltage was measured with the EUT in a shielded room. The EUT was connected to AC power source through an Artificial Mains Network which provides a 50 linear impedance Artificial hand is used if appropriate (for handheld apparatus). The load/control terminal disturbance voltage was measured with passive voltage probe if appropriate. The vertical conducting plane or wall of a screened room shall be located 40 cm to the rear of the EUT. All other surfaces of tabletop EUTs shall be at least 80 cm from any other grounded conducting surface, including the case or cases of one or more LISNs The table-top EUT was placed on a 0.8m high non-metallic table above earthed ground plane(Ground Reference Plane).And for floor standing EUT, was placed on a 0.1m high non-metallic supported on GRP. The Artificial Mains Network is situated at a distance of 0.8m from the EUT. During the test, mains lead of EUT excess 0.8m was folded back and forth parallel to the lead so as to form a horizontal bundle with a length between 0.3m and 0.4m. Report No: 140414100GZU-002 Issued: 16 June 2014 FCC ID: YHXESQ-3040C6 Page 4 of 23 The bandwidth of test receiver was set at 9 kHz. The frequency range from 150 kHz to 30MHz was checked. 1.4 Test Facility All of the tests are performed at: Intertek Testing Services Shen…
Text truncated - open the document above for the full version.
Block E, No.7-2 Guang Dong Software Science Park, · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.44 GHz - 2.44 GHz | - |

Digital charcoal Griddle+Grill+Smoker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Digital charcoal smoker
Equipment Class
DTS - Digital Transmission System
30 and 40 inch Electric Smoker with Bluetooth
Equipment Class
DTS - Digital Transmission System
Black Electric Smoker
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Electric Smoker with RF
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter