FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Essence Security International ltd./
  3. YXG-ES8000WG

YXG-ES8000WGWeRATHome Hub ES8000WG

Essence Security International ltd.
WeRATHome Hub ES8000WG - FCC ID YXG-ES8000WG - Essence Security International ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 08, 2015
Application Purpose
Original Equipment
Date of Application
Jul 08, 2015
Equipment Note
WeRATHome Hub ES8000WG
Frequency Range
2425.00000000 - 2425.00000000
Company
Essence Security International ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Setup Guide 2 Quick Setup Guide Legal Notice Usage of this document, and all information (including product information) provided within, are subject to the following terms and conditions, and all applicable laws. If you do not agree with these terms, please do not access or use the remainder of this document. This document contains highly confidential information, which is proprietary to Essence Security International (E.S.I.) Ltd. and/or its affiliates (hereafter, “Essence”). No part of this document’s contents may be used, copied, disclosed or conveyed to any third party in any manner whatsoever without prior written permission from Essence. The information included in this document is intended for your knowledge and for negotiation purposes only. Essence makes no implicit representations or warranties with respect to such information. The information included in this document is subject to change without notice. Any decision to rely on the information contained herein shall be at your sole responsibility, and Essence will not accept any liability for your decision to use any information or for any damages resulting therefrom. Certain laws do not allow limitations on implied warranties or the exclusion or limitation of certain damages. If these laws apply to you, some or all of the above disclaimers, exclusions, or limitations may not apply to you. By using the information contained herein, you agree that the laws of the State of Israel, without regard to principles of conflict of laws, will govern any dispute of any sort that might arise between you and Essence regarding the information contained herein, and any such dispute shall be settled exclusively in the competent courts of Tel Aviv-Jaffa, Israel. All registered or unregistered trademarks, product names, logos and other service marks mentioned within this document are the property of Essence, or their respective owners. Nothing contained herein shall be construed as conferring by implication, estoppels, or otherwise any license or right, either express or implied, under any patent or trademark of Essence or any third party. No use of any trademark may be made without the prior written authorization of Essence. This document and all of its contents are protected intellectual property of Essence. Any copying, reprinting, reuse, reproduction, adaptation, distribution or translation without the prior written permission of Essence is prohibited. Please check your End User License Agreement (EULA) for terms and conditions. © 2015 All rights reserved to Essence Security International (E.S.I.) Ltd. 3 Quick Setup Guide WeR@Home™ Home Monitoring and Management System Quick Setup Guide WeR@Home™ is a self-monitoring Smart Home solution that allows you to control and manage your home with an easy, Do-It-Yourself (DIY) installation, as described in this document. WeR@Home™ offers complete peace of mind by enabling you to monitor and manage your home from remote locations using mobile devices. With the Z-Wave® Extender and Smart Rules, you will be able to fully automate your home and enjoy an integrated Connected Home Experience. This Quick Setup Guide describes the installation process and daily usage of your WeR@Home™ System. If you experience any problems with this process or need further information, please go to: www.essence-grp.com/contact NOTE: Internet access is required as part of this installation process. Peace of Mind 24x7 4 Quick Setup Guide Except as prohibited by local law, the manufacturer’s total liability in connection with this product is limited, in any event, to direct damages in an amount not exceeding the amount you actually paid for the product. See your EULA for terms and Conditions. Please address any technical inquiries or complaints to the product’s local service provider. 5 Quick Setup Guide Hub (Panel) Camera (IPD) Accessories Remote Control battery Remote Control Unit Hub backup battery Siren Ethernet LAN Cable Motion Detector Power Supply Door/Window Sensor Inspect Kit Contents, Materials and Tools ●Make sure you have a free LAN port for the Internet connection, such as a router with a RJ-45 connector. ●Ten 1.5v, AA-size alkaline batteries for the peripheral devices. ●The 8-character serial number , found on labels in the battery compartment and on the bottom of the base of the Hub. ●Please record the serial number here: 1 7 6 8 910 2 3 4 5 1 6 Quick Setup Guide The WeR@Home™ Hub is the gateway between the Internet and the WeR@Home™ peripheral devices, installed in your home. The WeR@Home™ Hub enables the automatic interaction between connected home devices. Communications Requirements: If your Service Provider supports GSM communications and your Hub has the SIM-card option, you have a choice of external communication channels. Choose one of the following as your external communications channel to the Internet: ●Home network - Requires an Ethernet LAN cable 7 ●A Cellular Channel - Requires a SIM-card. Essence recommends the Ethernet channel for its reliability. NOTE: If both the SIM-card and LAN cable are installed, the cellular channel is used as backup. Positioning: The Hub should be installed on a flat surface in a central home or office location with: ●Adequate cellular coverage, if cellular communication is used. ●A flat surface near the router or LAN connection you plan to use, if Internet communications is used. The WeR@Home™ Hub 2 7 Quick Setup Guide Hardware Installation: 1. Remove the back cover of the Hub, 2. Do one of the following, according to your choice of external communications channel: ●Insert the SIM-card , if your HUB supports GSM Communications. ●Attach an Ethernet LAN cable between the port on the back of the Hub and a free socket in your Internet modem or router. NOTE: If you choose to install both the SIM-card and LAN cable, the cellular channel is used as backup. 3. Insert the backup battery 10 over the SIM-card with the contacts facing downwards and towards the base and return…

Text truncated - open the document above for the full version.

Cover Letter(s)

Declaration We hereby declare that ES8000WG was designed so that both the Telit module FCC ID:RI7HE910NA and Essence Security 2.4 GHz transceiver can be operated either simultaneously or non-simultaneously. Due to manufacturing reasons, we have decided to limit the operation to non-simultaneous transmission mode. The devices will be marketed in non-simultaneous transmission operation only (factory pre-set during manufacturing process) and the customer has no option to change the transmission operation to simultaneous transmission. The device was tested in simultaneous transmission mode. Operation in non-simultaneous transmission mode does not affect the test results.

Cover Letter(s)

Confidential Page 1 of 1 Date: June 15, 2015 Attn: Reviewing Engineer Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: The Essence Security ES8000WG, FCC ID: YXG-ES8000WG, and label are so small that it cannot include the statement specified in FCC Part 15 Sub-part A, Section 15.19 (a) (3) “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation." Due to this reason, we are using the provisions of Part 15 Sub-part A, Section 15.19 (a) (5) and this statement appears in a prominent location in the user manual. Please contact me if there is any information you may need. Sincerely,

Cover Letter(s)

Confidential Page 1 of 1 Date: June 15, 2015 To: Timco Engineering Inc. To Whom It May Concern We hereby authorize Mr. Shaike Raz of I.T.L. (Product Testing) Ltd (ITL) to sign FORM 731 on our behalf for the following application: FCC ID: YXG-ES8000WG Thank you,

Cover Letter(s)

Confidential Page 1 of 1 Date: June 15, 2015 To: Timco Engineering Inc. To Whom It May Concern We hereby authorize Mr. Shaike Raz of I.T.L. (Product Testing) Ltd (ITL) to act on our behalf regarding the FCC ID Certification Process for the following application: FCC ID: YXG-ES8000WG Thank you,

Cover Letter(s)

Confidential Page 1 of 2 Date: June 15, 2015 Federal Communications Commission Authorization and Evaluation Division To: Federal Communications Commission Confidentiality Request regarding application for certification of FCC ID: YXG-ES8000WG Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: a. CONF APPENDIX ES8000WG Schem.pdf b. CONF APPENDIX ES8000WG Partlst.pdf c. CONF APPENDIX ES8000WG BlkDia.pdf d. CONF APPENDIX ES8000WG OpDes.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Confidential Page 2 of 2

ID Label/Location Info

The labels Assembling on ES8000GW

Parts List/Tune Up Info

Confidential Page 1 of 1 Date: June 15, 2015 To: Federal Communications Commission Subject: FCC ID: YXG-ES8000WG Tune up procedure No manual tune-up procedure required. Thank you,

Test Report

Test Report E151860.01Essence SecurityLtd.Page1of51 FCC ACC M Ver 1.228 February 201 DATE:02July2015 I.T.L. (PRODUCT TESTING) LTD. FCC Radio Test Report for Essence Security Ltd. Equipment under test: WeR@Home Hub ES8000WG* 2425MHz Transmitter *See customer’s declaration on page 6. Testedby:_____________________________ N. Levi Approved by:_____________________________ D. Shidlowsky This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E151860.01Essence SecurityLtd.Page2of51 FCC ACC M Ver 1.228 February 201 Measurement/Technical Report for Essence Security Ltd. WeR@HomeHub ES8000WG 02July2015 This report concerns:Original Grant:X Class IChange: Class II Change: Equipment type:Digital Transmission System Limits used:47CFR15 Section 15.247 RSS210, Issue 8,December 2010 Measurement procedure used isKDB 558074 D01v03r02andANSI C63.4-2009. Application for CertificationApplicant for this device: prepared by:(different from "prepared by") R. PinchuckIgal Zertser ITL (Product Testing) Ltd.Essence Security International Ltd. 1 Bat Sheva St.12 Abba Eben Avenue, P.O.B. 2073 Lod 7116002Ackerstein Tower Bldg D, IsraelHerzeliya, 4612001,Israel [email protected]:+972-9-958-5987 Fax:+972-9-956-4182 e-mail:[email protected] Test Report E151860.01Essence SecurityLtd.Page3of51 FCC ACC M Ver 1.228 February 201 TABLE OF CONTENTS 1.GENERAL INFORMATION---------------------------------------------------------------------------5 1.1Administrative Information...........................................................................5 1.2List of Accreditations...................................................................................7 1.3Product Description.....................................................................................8 1.4Test Methodology........................................................................................8 1.5Test Facility.................................................................................................8 1.6Measurement Uncertainty...........................................................................8 2.SYSTEM TEST CONFIGURATION-----------------------------------------------------------------9 2.1Justification..................................................................................................9 2.2EUT Exercise Software...............................................................................9 2.3Special Accessories....................................................................................9 2.4Equipment Modifications.............................................................................9 2.5Configuration of Tested System................................................................10 3.CONDUCTED & RADIATEDMEASUREMENT TEST SET-UP PHOTOS-------------11 4.CONDUCTED EMISSION FROM AC PORTS-------------------------------------------------13 4.1Test Specification......................................................................................13 4.2Test Procedure..........................................................................................13 4.3Test Results...............................................................................................13 4.4Test Equipment Used; Conducted Emission.............................................18 5.6 DB MINIMUM BANDWIDTH---------------------------------------------------------------------19 5.1Test Specification......................................................................................19 5.2Test Procedure..........................................................................................19 5.3Test Results...............................................................................................19 5.4Test Equipment Used; 6dB Bandwidth.....................................................20 6.26 DB MINIMUM BANDWIDTH--------------------------------------------------------------------21 6.1Test Specification......................................................................................21 6.2Test Procedure..........................................................................................21 6.3Test Results...............................................................................................21 6.4Test Equipment Used; 26 dB Minimum Bandwidth...................................22 7.MAXIMUM TRANSMITTEDPEAK POWER OUTPUT--------------------------------------23 7.1Test Specification......................................................................................23 7.2Test Procedure..........................................................................................23 7.3Test Results...............................................................................................24 7.4Test Equipment Used; Maximum Transmitted Peak Power Output..........26 8.BAND EDGE SPECTRUM--------------------------------------------------------------------------27 8.1Test Specification......................................................................................27 8.2Test Procedure..........................................................................................27 8.3Test Results...............................................................................................27 8.4Test Equipment Used; Band Edge Spectrum...........................................29 9.TRANSMITTED POWER DENSITY--------------------------------------------------------------30 9.1Test Specification......................................................................................30 9.2Test Procedure..........................................................................................30 9.3Test Results...............................................................................................30 9.4Test Equipment Used; Transmitted Power Density..................................32 10.RADIATED EMISSION, 9KHZ–30 MH…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Tal Cohen(Certification Manager)
[email protected]+972732447705Fax: +97297729962

Test Firm

Israel Testing LaboratoriesIIan Cohen
[email protected]972-3-5339022Fax: 972-3-5339019

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.42 GHz - 2.42 GHz12.90 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. End-users must be provided with the specific operating instructions for satisfying RF exposure compliance. The device must operate with the minimum separation distance tested for compliance, as described in this filing, which is 20 cm.

Other Applications from Essence Security International ltd.

Tag Reader with Keypad - FCC ID YXG-ES700TRKPD - Essence Security International ltd.
YXG-ES700TRKPD

Tag Reader with Keypad

Oct 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Z-Wave extender - FCC ID YXG-ES800ZWE - Essence Security International ltd.
YXG-ES800ZWE

Z-Wave extender

Sep 01, 2015

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Flood detector - FCC ID YXG-ES800FL - Essence Security International ltd.
YXG-ES800FL

Flood detector

Mar 10, 2014

Equipment Class

DTS - Digital Transmission System
Universal transmitter - FCC ID YXG-ES800UT - Essence Security International ltd.
YXG-ES800UT

Universal transmitter

Mar 09, 2014

Equipment Class

DTS - Digital Transmission System
Indoor siren - FCC ID YXG-ES700ISN - Essence Security International ltd.
YXG-ES700ISN

Indoor siren

Jan 26, 2014

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver