FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Penclic AB/
  3. ZRQ-R3

ZRQ-R3PENCLIC WIRELESS MOUSE

Penclic AB
PENCLIC WIRELESS MOUSE - FCC ID ZRQ-R3 - Penclic AB
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 20, 2012
Application Purpose
Original Equipment
Date of Application
May 20, 2012
Equipment Note
PENCLIC WIRELESS MOUSE
Frequency Range
2405.00000000 - 2476.00000000
Company
Penclic AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

approved by: date: Technical info non print. Client: Penclic Item: quickguide wireless Technical info: dyecut marks found in cyan layer. corners must match those found in QG-wirelss-cover.pdf Bind: stapled Product name: Penclic Mouse R2/D2 Printing: 70g writing paper filnamn: QG-wireless.pdf Colours Contact: Planeta Design grev magnigatan 6, 3tr Contact person: pantone warm red C Sandra planeta tel: 0046 (0)8 666 00 52 email: [email protected] 100%black = dicect (do not print) qg-wl-notes.indd 1 2011-06-27 21.27 Penclic Mouse R2™ Quickguide EN Quickguide 2 EN Welcome to the quick guide. Penclic Mouse™ combines ergonomically sound design with modern mouse technology to bring you unparalleled precision, comfort and efficiency. Mouse setup Remove plastic film from the installed battery., then set the mouse power switch on the bottom of the mouse to ON. The wireless connection activates automatically. How to use your Penclic Mouse™ 1. Hold Penclic Mouse™ like a pen, the bottom part acts like a traditional mouse. 1 2 3 4 5 6 7 Left click Right click Middle click Backward click Forward click Scroll wheel On-off switch Troubleshooting www.Penclic.se/troubleshooting · Connect to another computer. · Cursor movement may be effected by very glossy surfaces. · Check the battery. 2. Let your forearm and your hand rest on a surface, while keeping your shoulders relaxed. 3. The pen par can be adjusted to suit specific grips. Fixate the bottom part with one hand and rotate the pen to the preferred angle with the other. · · When the battery needs charging the LED on the mouse will show red. When the battery is fully charged a green light will be displayed. 3 QG-Wireless.indd 2-3 2011-06-27 21.27 Technical specifications Technical support The supported platforms for Penclic Mouse™ are all operating systems that support HID 1.1. These include Windows XP or later, Mac OSX version 10.1 or later and most Linux/BSD flavors. No extra software/driver installation is needed. · Operates on almost any surface without any pad or tablet. · Implements a 5-button and scroll wheel. · · Charging via USB. · LR 03/AAA/1.5V Alkaline None rechargeable battery can be used. NOTE: do not recharge. · Energy saving mode starts after 10 min, press a button to start. · Wireless reach, minimum 5 metres. · Dpi setting 800-1200-1600-2400. NOTE: the dpi setting can be changed by holding in the left and right button at the same time for 3 sec, the cursor will move faster for each setting. It will rotate around from 800-2400 and then go back to low 800. Once the power is shut of the dpi setting will return to its default setting, 1200 dpi. Measurements: Height: 140 mm, Base: 44.1 x 20 mm. Weight: 41 g Should you require additional technical support with your Penclic Mouse™ , please use our Web site for further information or contact our support group through e-mail. Call Technical Support during business hours, central European time plus one hour. Contact: 0046 8 544 98 995 email: [email protected] · AAA 1.2V NiMH Recharging battery (Everyday use last approximately 3 months before charging is needed). 4 QG-Wireless.indd 4-5 5 2011-06-27 21.27 QG-Wireless.indd 50-5 2011-06-27 21.27 PenClic Technology AB Vendevägen. 90 / 182 32 DANDERYD [email protected] / www.penclic.se tel: 0046 8 544 98 995 QG-Wireless.indd 54 2011-06-27 21.27 FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IC WARNING This device complies with Industry Canada RSS-210 standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of PCB and maximum 0dBi gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (IC:9999A-R2) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. No. Antenna Type Gain Impedance 1 PCB 0 dBi 5…

Text truncated - open the document above for the full version.

Block Diagram

Block Diagram M24-001 MCU RF EEPROM ADNS7530 Sensor XTAL 16MHz DC 1.5V Antenna Ant. 2405-2476MHz

Cover Letter(s)

Penclic AB Vendev. 90, 7tr182 32, Danderyd, Sweden -------------------------------------------------------------------------------- (FCC ID:ZRQ-R3) POWER OF ATTORNEY DATE: 2012-05-14 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize SEM.Test Compliance Service Co., Ltd. Jandy So on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by SEM.Test Compliance Service Co., Ltd. Jandy So on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Penclic AB are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Penclic AB ------------------------- (Olle Wahlqvist) (CTO)

ID Label/Location Info

Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 EXHIBIT 1- PRODUCT LABELING Proposed FCC ID Label Format Penclic AB Model: R2 Product Name: Penclic Wireless Mouse FCC ID: ZRQ-R3 IC: 9999A-R2 Specifications : Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location

ID Label/Location Info

Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 EXHIBIT 1- PRODUCT LABELING Proposed FCC ID Label Format Penclic AB Model: R2 Product Name: Penclic Wireless Mouse FCC ID: ZRQ-R3 IC: 9999A-R2 Specifications : Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location

Internal Photos

Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View Solder Board-Component View 1 Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 Solder Board-Component View 2

Operational Description

Circuit Description 1, IC U2(M24-001) is used for wireless transmission chip. The signal to the receiver by built-in RF, and a clock frequency of the 16MHz as base clock signal, the 2.4G RF transmitting frequency is 2405 to 2476MHz with GFSK modulation. 2, The work voltage is DC 1.5V by AAA battery or NI-MH rechargable battery, and you could to recharge the battery via USB charging port.

Schematics

44 33 22 11 4 4 3 3 2 2 1 1 Y.C. Chen D.C. Closed toRF XIO 2.4G RF SoC Closed toRF VCCD Closed toVDD_OUT (DIR2) Not Mount Sensor Orientation Not Mount MountR8 (DIR2) 90 degree Not Mount Not Mount 180 degree MountR7 (DIR1) 270 degree 0 degree Mount Mount Closed toRF_VDD Closed toRF_ANT Digital GND & Analog GND Should be connected by this point GND PCBANT ANT PCB LayoutPattern seeAppendix Closed toRF_ANT For EMI concern ** ** C8 and C9depend on X1Crystal Spec TBDTBD TBD (DIR1) Ext DC Power Block Closed toSoC VDDpin Closed toDC/DC Lxpin TBD TBD ## ## #### #### ## ## Depend on Z Encoder quality (optional) Closed to Sensor Closed to Sensor Closed to Sensor Laser Sensor ADNS-7530 Closed to Q1 Not Mount INT. DC 2CELLExt. DC 2CELL ( ## ) Ext. DC 1CELL R4, R13R5, R6, U3, D1 R4, R9,R10,R13 Mount R5, R6, R9, U3, D1 Power Type R4, R10, R13 Power Straps Option R5, R6, R9, R10, U3, D1 Keypad Tilt-Wheel Buttons 2.4GHZ-2W-ISS-MSE-M24-001-A7530-TX-A-TECH A1 2.4GHz 2way RF SoC Laser Mouse Solution ( DC optional) B 11 Friday, May 01, 2009 TitleSize Document Number Rev Date: Sheet of SunplusIT ENG. AP: Drawn: Check By: BIND NCS R2R0 RF_PWR S0 VSS MISO RF_PWR R1 MOSI S1 S2 ZA R3 ESCLK RF_PSB ZB BIND DIR BIND RF_PWR ZBZA MOTION MISOMOTIONNCSMOSIESCLK RF_PSB R0R2R1 S2 S1 R3 S0 VCC RFVCC VCC VCC VCC SVDD RFVCC VCC VCC SVDD ADNS7530 U1 821413 9 54637 10 1 15 12 16 11 XYLASER LASER_NEN DGND RefA VDD3 SCLKMISOMOSINCSMOTIONNC +VCSEL VDDIO VDD3 -VCSEL GND S7 TILT-L D1 1N5819 1 2 + C273.3uF C17 1pF C1022pF C29470pF U3 XC6383A-281PR 3 2 1 Lx Vout Vss R121M C280.1uF + C610uF S5 B5_DN R733K Q1 2N3906 3 2 1 C180.1uF S2 MB C130.01uF L2 0R C140.01uF SW2BIND S3 RB C820pF + C14.7uF C1922pF + C253.3uF C71uF C40.1uF R31K LD2 BAT_LOW S8 TILT-R R130R SW3SW MAG-SPDT X1 16MHz C16 0.1uF C2122pF S6 CPI C112.2nF C23 0.1uF C150.1uF + C2100uF L5 100uH C22 0.1uF R9 10M 1% R833K C201pF S1 LB C260.1uF R50R + C3 100uF R10 10M 1% L422nH L33.3nH SW1Z Encoder 32 1 U2 M24-001 1234 11 12 13 14 24262830 31 32 33 34 56789 10 15 16 17 18 19 20 212223252729 35 36 37 38 39 40 VBATVDD_OUTTESTVLX RF_GNDD RF_VDDD RF_XOUT RF_XIN RF_VCC PB1 PD2PD0 PC5 PA4 PA3 PB2 PC6VSSPA5VDDPA1RF_VCCD RF_PSB RF_VCOG RF_VCOPG RF_VCOVDD RF_VDD ANT1 ANT2 RF_GNDPG RF_GND GND_IF PC4PD1 PB3 PA6 PA7 PB0 PB7 PB6 R40R S12 CUST4 R60 C24 1uF R1 2K C920pF S4 B4_UP R14 10R C12 2pF S11 CUST3 R11 10R S10 CUST2 J1 BAT Conn 12 S9 CUST1 V_BAT V_BAT V_BAT VLX1 VLX1

Test Report

Penclic AB Model: R2 REPORT NO.: STR12048258I PAGE 1 OF 23 FCC PART 15.249 FCC PART 15.249 MEASUREMENT AND TEST REPORT FOR Penclic AB Vendev. 90, 7tr182 32, Danderyd, Sweden FCC ID: ZRQ-R3 Report Concerns: Original Report Equipment Type: Penclic Wireless Mouse Model: R2 Report No.: STR12048258I Test Date: 2012-04-24 to 2012-05-07 Issue Date: 2012-05-17 Tested By: Silin Chen / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: SEM.Test Compliance Service Co., Ltd 3/F, Jinbao Commerce Building, Xin'an Fanshen Road, Bao'an District, Shenzhen, P.R.C.(518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by SEM.Test Compliance Service Co., Ltd . Penclic AB Model: R2 REPORT NO.: STR12048258I PAGE 2 OF 23 FCC PART 15.249 TABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................................................3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...............................................................................3 1.2 TEST STANDARDS...................................................................................................................................................3 1.3 TEST METHODOLOGY.............................................................................................................................................3 1.4 TEST FACILITY.......................................................................................................................................................4 1.5 EUT EXERCISE SOFTWARE....................................................................................................................................4 1.6 ACCESSORIES EQUIPMENT LIST AND DETAILS.......................................................................................................4 1.7 EUT CABLE LIST AND DETAILS.............................................................................................................................4 2. SUMMARY OF TEST RESULTS ...........................................................................................................................5 3. ANTENNA REQUIREMENT ..................................................................................................................................6 3.1 STANDARD APPLICABLE.........................................................................................................................................6 3.2 TEST RESULT..........................................................................................................................................................6 4. RADIATED EMISSIONS .........................................................................................................................................7 4.1 MEASUREMENT UNCERTAINTY..............................................................................................................................7 4.2 STANDARD APPLICABLE.........................................................................................................................................7 4.3 TEST EQUIPMENT LIST AND DETAILS.....................................................................................................................7 4.4 TEST PROCEDURE...................................................................................................................................................8 4.5 CORRECTED AMPLITUDE & MARGIN CALCULATION..............................................................................................8 4.6 ENVIRONMENTAL CONDITIONS..............................................................................................................................8 4.7 SUMMARY OF TEST RESULTS/PLOTS......................................................................................................................9 5. OUT OF BAND EMISSIONS.................................................................................................................................17 5.1 STANDARD APPLICABLE.......................................................................................................................................17 5.2 TEST EQUIPMENT LIST AND DETAILS...................................................................................................................17 5.3 TEST PROCEDURE.................................................................................................................................................17 5.4 ENVIRONMENTAL CONDITIONS............................................................................................................................17 5.5 SUMMARY OF TEST RESULTS/PLOTS....................................................................................................................17 6. CONDUCTED EMISSIONS ..................................................................................................................................20 6.1 MEASUREMENT UNCERTAINTY............................................................................................................................20 6.2 TEST EQUIPMENT LIST AND DETAILS...................................................................................................................20 6.3 TEST PROCEDURE.................................................................................................................................................20 6.4 BASIC TEST SETUP BLOCK DIAGRAM...................................................................................................................20 6.5 ENVIRONMENTAL CONDITIONS............................................................................................................................21 6.6 SUMMARY O…

Text truncated - open the document above for the full version.

Test Setup Photos

Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Conduction Emsission Test Setup Only Charging Radiation Emission Test Setup (30MHz to 1GHz) Penclic AB Model: R2 REPORT NO.: STR12048258I FCC PART 15.249 Radiation Emission Test Setup (Above 1GHz)

Contact Information

Applicant

Olle Wahlqvist(CTO)
[email protected]+46 70 580 8454Fax: +46 8 544 98 990

Test Firm

SEM.Test Compliance Service Co., Ltd.Jandy So
[email protected]086-755-33663308Fax: 086-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-

Other Applications from Penclic AB

Penclic Keyboard KB4 - FCC ID ZRQKB4 - Penclic AB
ZRQKB4

Penclic Keyboard KB4

Oct 08, 2020

Equipment Class

DTS - Digital Transmission System
Penclic wireless keyboard - FCC ID ZRQ-K3 - Penclic AB
ZRQ-K3

Penclic wireless keyboard

Dec 01, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Penclic mouse - FCC ID ZRQ-B4 - Penclic AB
ZRQ-B4

Penclic mouse

Aug 13, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Penclic mouse - FCC ID ZRQ-R5 - Penclic AB
ZRQ-R5

Penclic mouse

Jun 24, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PENCLIC MOUSE - FCC ID ZRQ-R4 - Penclic AB
ZRQ-R4

PENCLIC MOUSE

Mar 06, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter