ZY4CM08EHoneycomb Motor

Coulisse B.V.
Honeycomb Motor - FCC ID ZY4CM08E - Coulisse B.V.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 01, 2023
Application Purpose
Original Equipment
Date of Application
Apr 01, 2023
Equipment Note
Honeycomb Motor
Frequency Range
2405.00000000 - 2480.00000000
Company
Coulisse B.V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Coulisse B.V. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03-21-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: ZY4CM08E Coulisse B.V. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Bas Klein Tuente

Attestation Statements

Rev 1/26/2023 Coulisse B.V. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03-21-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: ZY4CM08E Coulisse B.V. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Bas Klein Tuente

Attestation Statements

Coulisse B.V. Vonderweg 48, 7468 DC Enter, THE NETHERLANDS Date: Mar.20,2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: ZY4CM08E US Agent – Attestation Statement / Part 2.911(d)(7) Coulisse B.V.certifies, that as of Mar.20,2023, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: ZY4CM08E. Coulisse B.V., accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Coulisse B.V. for FCC ID: ZY4CM08E. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: Coulisse B.V. Designated Agent: FCC US Agent, LLC Company Representative: Bas Klein Tuente Designated Agent Representative: Tim Payne Signature: Signature:

Cover Letter(s)

Rev 11/20/07 Coulisse B.V. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: ZY4CM08E Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematics Block Diagram Schematics Operation Description Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Internal Photos User’s Manual Setup Photos Internal Photos User’s Manual Setup Photos Number of days: 180 days Sincerely, (Must be signed by the person that is listed on the FCC Website) (signature) (printed name) Bas Klein Tuente

Cover Letter(s)

C:\Data\20220609\1项目\814.709502228931 杜亚 FCC ID IC\3.测试软件及资料\FCC POA _Letter.docx Coulisse B.V. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: Mar. 21, 2023 SUBJECT: FCC Application for FCC ID:ZY4CM08E To Whom It May Concern: We, the undersigned, hereby authorize Yu Anlu at TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Printed Name: Bas Klein Tuente Signature:

Cover Letter(s)

Coulisse B.V. Date: 2023-03-21 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: ZY4CM08E To Whom It May Concern: This letter is to ascertain that Coulisse B.V. Product name: HONEYCOMB MOTOR , Model: CM-08-E has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Company name: Coulisse B.V. Address: Vonderweg 48, 7468 DC Enter, THE NETHERLANDS

External Photos

External Photos Documentation Manufacturer: Coulisse B.V. Page 1 of 3 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E External Photos Documentation Manufacturer: Coulisse B.V. Page 2 of 3 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E External Photos Documentation Manufacturer: Coulisse B.V. Page 3 of 3 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E

ID Label/Location Info

label location

ID Label/Location Info

538-59-11 备注 538-59-11 538# A-01 校对 设计 魏娟 方肖酉 适用产品 材 质 油 墨 是否覆膜 印刷工艺 是否含流水码 或条形码 审定 版本 日期 制图 颜 色 尺 寸0.1±0.01mm(厚度) 使用规范 工艺描述 客户号 杜亚机电 铭牌 JS-6-15 2023.3.4 符合:ROHS REACH法规要求 黑 UV油墨 黑白印刷 进口透明材质 覆光膜 贴电机 DV24LEA/CB-0.6/34 EVE 蓝牙系列 144x14mm(长*宽) 图纸认证说明 (此尺寸为本图内1:1尺寸) 5.2mm 7.2mm 7.2mm 5.2mm MODEL CM-08-E HONEYCOMB MOTOR TORQUE 0.6Nm SPEED 34rpm OPERATING TIME 12min INPUT USB-C 5V 7W This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interierence, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: ZY4CM08E IC:28177-CM08E Coulisse B.V. Vonderweg 48, 7468 D C Enter, The Netherlands Conforms to ANSI/CAN/UL Std.325

Internal Photos

Internal Photos Documentation Manufacturer: Coulisse B.V. Page 1 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Antenna for SRD Antenna for BLE and Thread Internal Photos Documentation Manufacturer: Coulisse B.V. Page 2 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 3 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 4 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 5 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 6 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 7 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 8 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 9 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 10 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 11 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 12 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 13 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 14 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 15 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E Internal Photos Documentation Manufacturer: Coulisse B.V. Page 16 of 16 Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E IC: 28177-CM08E Model: CM-08-E

RF Exposure Info

Report No: 709502228931-00D EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 3 Rev. 20.00 MPE Calculation Applicant: Coulisse B.V. Address: Vonderweg 48, 7468 DC Enter, THE NETHERLANDS Product: HONEYCOMB MOTOR FCC ID: ZY4CM08E Model No.: CM-08-E Reference RF report # 709502228931-00A, 709502228931-00B, 709502228931-00C According to subpart 15.247(i)and subpart §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1,500 / / f/1500 30 1,500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Report No: 709502228931-00D EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 3 Rev. 20.00 Calculated Data for BLE Maximum peak output power at antenna input terminal (dBm): 6.08 Maximum peak output power at antenna input terminal (mW): 4.06 Prediction distance (cm): 20 Antenna Gain, typical (dBi): 2.2 Maximum Antenna Gain (numeric): 1.660 The worst case is power density at predication frequency at 20 cm (mW/cm 2 ): 0.0013 MPE limit for general population exposure at prediction frequency (mW/cm 2 ): 1.0 The max power density 0.0013 (mW/cm 2 ) < 1 (mW/cm 2 ) Result: Compliant Calculated Data for Thread Maximum peak output power at antenna input terminal (dBm): 7.39 Maximum peak output power at antenna input terminal (mW): 5.48 Prediction distance (cm): 20 Antenna Gain, typical (dBi): 2.2 Maximum Antenna Gain (numeric): 1.660 The worst case is power density at predication frequency at 20 cm (mW/cm 2 ): 0.0018 MPE limit for general population exposure at prediction frequency (mW/cm 2 ): 1.0 The max power density 0.0018 (mW/cm 2 ) < 1 (mW/cm 2 ) Result: Compliant Calculation method for 433.92MHz Per the test report included herein, for 433.92MHz According to C63.10 Annex G EIRP = pt × gt =(E × d) 2 /30 where pt is the transmitter output power in watts gt is the numeric gain of the transmitting antenna (dimensionless) E is the electric field strength in V/m d is the measurement distance in meters (m) transmitter output power for 433.92MHz Function Field strength (E): 85.844 (dBuV/m) = 0.0196 (V/m) Measurement Distance(dMeas): 3 (m) Equivalent Isotropically Radiated Power(EIRP): 0.000115248W=0.115248mW Report No: 709502228931-00D EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 3 Rev. 20.00 According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); PG = 0.115248mW (in appropriate units, e.g., mW); R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: The max power density 0.115248/4πR²= 2.29279*10 -5 (mW/cm 2 ) < 0.28928 (mW/cm 2 ) Result: Compliant Simultaneous transmission of MPE test exclusion for worst case configuration BLE: the ratio is 0.0013/1 Thread: the ratio is 0.0018/1 433.92MHz:the ratio is 2.29279*10 -5 / 0.28928=7.926*10 -5 The sum of the MPE ratios for all simultaneous transmitting antennas: 0.0013+0.0018+7.926*10 -5 =3.17926*10 -3 As the sum of MPE ratios for all simultaneous transmitting antennas is ≤ 1.0, simultaneous transmission MPE test exclusion will be applied. - TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Reviewed by: Prepared by: Tested by: _____________________ _____________________ ______________________ Hui TONG Wenqiang LU Yiquan WANG EMC Section Manager EMC Project Engineer EMC Test Engineer Date: 2023-03-20 Date: 2023-03-20 Date: 2023-03-20

Test Report

EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 38 Rev. 20.00 FCC/IC - TEST REPORT Report Number : 709502228931-00A Date of Issue: March 28, 2023 Model : CM-08-E Product Type : HONEYCOMB MOTOR Applicant : Coulisse B.V. Manufacturer : Coulisse B.V. Address : Vonderweg 48, 7468 DC Enter, THE NETHERLANDS Test Result : ◼ Positive  Negative Total pages including Appendices : 38 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 709502228931-00A EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 38 Rev. 20.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment under Test ............................................................................... 4 4 Summary of Test Standards .................................................................................................. 6 5 Summary of Test Results ...................................................................................................... 7 6 General Remarks .................................................................................................................. 8 7 Test Setups ........................................................................................................................... 9 8 Systems test configuration .................................................................................................. 12 9 Technical Requirement ........................................................................................................ 13 9.1 Conducted Emission ..................................................................................................... 13 9.2 Conducted peak output power ...................................................................................... 16 9.3 6dB bandwidth and 99% Occupied Bandwidth ............................................................. 18 9.4 Power spectral density .................................................................................................. 21 9.5 Spurious RF conducted emissions ............................................................................... 23 9.6 Band edge .................................................................................................................... 27 9.7 Spurious radiated emissions for transmitter .................................................................. 30 10 Test Equipment List .......................................................................................................... 35 11 System Measurement Uncertainty ................................................................................... 36 12 Photographs of Test Set-ups ............................................................................................ 37 13 Photographs of EUT ........................................................................................................ 38 Report Number: 709502228931-00A EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 38 Rev. 20.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China FCC Registration Number: 820234 Designation Number: CN1183 IC Company Number: 25988 CAB identifier: CN0101 Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 Report Number: 709502228931-00A EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 38 Rev. 20.00 3 Description of the Equipment under Test Description of the Equipment Under Test Product: HONEYCOMB MOTOR Model no.: CM-08-E PMN: CM-08-E HVIN: CM-08-E FCC ID: ZY4CM08E IC: 28177-CM08E Options and accessories: NA Rating: DC 12V RF Transmission Frequency: 2402~2480 MHz for BLE 2405~2480 MHz for Thread 433.92 MHz for SRD No. of Operated Channel: 40 for BLE 16 for Thread 1 for SRD Modulation: GFSK for BLE 16-ary orthogonal modulation, O-QPSK PHY for Thread 2GFSK for SRD Data transmission rate: 1 Mbit/s for BLE Channel list for Thread: Antenna Type: Line…

Text truncated - open the document above for the full version.

Test Report

EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 38 Rev. 20.00 FCC/IC - TEST REPORT Report Number : 709502228931-00C Date of Issue: March 28, 2023 Model : CM-08-E Product Type : HONEYCOMB MOTOR Applicant : Coulisse B.V. Address : Vonderweg 48, 7468 DC Enter, THE NETHERLANDS Production Facility : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd. Address : No.168 Shengguang Road, Luotuo, Zhenhai 315202 Ningbo, Zhejiang province People's Republic of China Test Result : ◼ Positive  Negative Total pages including Appendices : 38 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 709502228931-00C EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 38 Rev. 20.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment under Test ............................................................................... 4 4 Summary of Test Standards .................................................................................................. 6 5 Summary of Test Results ...................................................................................................... 7 6 General Remarks .................................................................................................................. 8 7 Test Setups ........................................................................................................................... 9 8 Systems test configuration .................................................................................................. 12 9 Technical Requirement ........................................................................................................ 13 9.1 Conducted Emission ..................................................................................................... 13 9.2 Conducted peak output power ...................................................................................... 16 9.3 6dB bandwidth and 99% Occupied Bandwidth ............................................................. 18 9.4 Power spectral density .................................................................................................. 21 9.5 Spurious RF conducted emissions ............................................................................... 23 9.6 Band edge .................................................................................................................... 27 9.7 Spurious radiated emissions for transmitter .................................................................. 30 10 Test Equipment List .......................................................................................................... 35 11 System Measurement Uncertainty ................................................................................... 36 12 Photographs of Test Set-ups ............................................................................................ 37 13 Photographs of EUT ........................................................................................................ 38 Report Number: 709502228931-00C EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 38 Rev. 20.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China Test Firm FCC Registration Number: 820234 Designation Number: CN1183 Test Firm IC Registration Number: 25988 CAB identifier: CN0101 Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 Report Number: 709502228931-00C EMC_SHA_F_R_02.10E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 38 Rev. 20.00 3 Description of the Equipment under Test Description of the Equipment Under Test Product: HONEYCOMB MOTOR Model no.: CM-08-E PMN: CM-08-E HVIN: CM-08-E FCC ID: ZY4CM08E IC: 28177-CM08E Options and accessories: NA Rating: DC 12V RF Transmission Frequency: 2402~2480 MHz for BLE 2405~2480 MHz for Thread 433.92 MHz for SRD No. of Operated Channel: 40 for BLE 16 for Thread 1…

Text truncated - open the document above for the full version.

Test Report

版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 NingboShenghong CommunicationsEquipmentCo., Ltd. Product Specification ProductName:WIFIAntennaK11Specification:SHZD2400-2U-K3 CompanyCode:SHSC3.945.04040CustomerCode: Compile:LijunReviewed:Tonghe Approved:PanqingsongFilenumber: Customer: Customeraffirm: date:2023.02.20 版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 2 WIFIAntennaK11 I.ProductName: II.Specification : III.TechnicalParameter: 1.ElectricalCharacteristics Frequencyrange : Polarization : MaxGain : MaxVSWR : Impedance : 3dBbeamwidth : Max.Power : Lightingprotection: 2400-2483MHz Vertical 2.2 dBi ≤ 3.8 50 Ω H:360 ° E:/ 10W DC Ground (Determinedbythesample) 2.MechanicalCharacteristics Input : U.FL ( male ) Cabletype:1.13orother Cablelength:195mm CableImpedance:50Ω Connectorpull-out:2N 版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 3 Antennaweight:about5g Radiationmaterial : copper Colour : White ( appointcolor ) (Determinedbythesample) 3. WorkingEnvironment: Temperature : -30ºC~+75ºC Corrosivegasenvironment : noacidityandnoalkalescenceinairallaround (contentingotherrequestenvironment) IV . MaxexteriorDimensions : Lx Φ: about 195 mm× Φ 2.9mm(Determinedbythesample) V . MaterielIntroduction: 1.GeneralSituation : ThisproductisDesignedaccordingtotheparticularcriterion,This antennawasusedtoTheWirelesspublic-WIFI.Thisantenna’sperformanceisexcellent,figurationis handsome,dependabilityiswell. 2.Package&Stockage : Thisproductshouldbepackedinplasticbox,andthen putintohardcarton;eachboxwithaconformitycertificate,whichisincludedproductP/N, date,checkingstamp,companystamp;eachboxisstickedwithproductP/N,package quantity.Thestockageconditionis:-10°C~+40°C;thecomparedhumidityis80%;being storedintheroomwithoutacidity,alkalescencyandcausticityinair. 3.ExchangeRelationship : U.FL-K 4.technics&use : immediatelyscrewon. JUNPERINTERCONNECTIONCO.,LTD, TECHNOLOGYCENTRE 2022.12.01 版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 4 外形图 版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 5 TheTesting Appendix1 TheDate NumberItemtypeRequiremengtResult 1Frequency2400-2483MHzOK 2BandWidth83MHzOK 3Polarization Vertical OK 4MaxGain2.2dBiOK 5MaxVSWR<3.82.53 6 Beam width H 360°360° E// 8InputUFL-KOK 版本号:V1.1 宁波市江北盛宏通信设备有限公司 NingboShenghongComunicationEquipmentLTD Http://www.Shenghong.bizTel:0574-87589736Fax:0574-87589646 6 Appendix2—VSWR WIFI antenna K11 测试数据(SHZD2400-2U-K11 ,长195cm) Frequency (MHz)240024122437244724622483 Directivity(dB)5.81255.58635.39265.39175.29365.4056 Gain(dB)2.02582.18961.91052.02682.01282.2123 Efficiency(dB)-3.4108-3.1922-3.3012-3.4013-3.0938-2.8988 Efficiency(%)49.668550.97850.263949.921851.96152.8652 BW@Phi=040.916338.31391.296687.753584.149741.9901 BW@phi=9030.654630.07129.63329.501130.341629.5976 BW@theta=9051.460550.950748.562447.925150.358485.689 Roundness@Theta=3010.456911.081411.904710.85448.81217.6726 Roundness@Theta=607.89438.397912.155813.7611.907213.2063 Roundness@Theta=9011.183911.622312.31312.405411.636511.5702 Peak Gain@Phi(deg)464646464646 Peak Gain@Theta(deg)-138-138-138-138-136-136 Null@Phi(deg)158158158158158158 Null@Theta(deg)-180-180-180-180-180-180 upper spherical eficiency(dB)-7.9586-7.5646-7.4142-7.51-7.3554-7.205 upper spherical eficiency(%)16.000717.520318.137417.741918.384919.0329 lower spherical efficiency(dB)-5.2771-5.163-5.3571-5.505-5.1462-5.041 lower spherical eficiency(%)29.667830.457729.126528.151730.576131.3255 Efficicency_LHCP(dB)-5.5811-5.3619-5.4457-5.6487-5.4414-5.2766 Efficicency_LHCP(%)27.662229.094128.538527.235128.566929.6717 Efficicency_RHCP(dB)-7.4457-7.2391-7.2757-7.2912-6.905-6.8431 Efficicency_RHCP(%)18.006318.883918.725418.658420.394120.6867 Gain_LHCP(dB)1.49321.51341.10770.85431.35551.8665 Gain_RHCP(dB)0.70590.72460.61510.62011.16481.2967 AR3.09723.69883.1082.54612.06421.9689 AR_dB9.819311.36129.84978.11756.29525.8846 功率占比(%)19.193619.872420.892820.906818.977418.4875 WIFI a…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bas Klein Tuente(Manager Engineering)
[email protected]+31 547855555Fax: +31 547855550

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]86 755 3332 3281

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz5.48 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power. Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Coulisse B.V.

Motionblinds Wifi Matter Bridge - FCC ID ZY4CM55 - Coulisse B.V.
ZY4CM55

Motionblinds Wifi Matter Bridge

Sep 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
hand-held remote with 5 channels for operating and programming blinds - FCC ID ZY4CM48 - Coulisse B.V.
ZY4CM48

hand-held remote with 5 channels for operating and programming blinds

Sep 24, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Transmitter - FCC ID ZY4CM49 - Coulisse B.V.
ZY4CM49

Transmitter

Sep 12, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
DC CURTAIN MOTOR - FCC ID ZY4CM36B - Coulisse B.V.
ZY4CM36B

DC CURTAIN MOTOR

May 18, 2023

Equipment Class

DTS - Digital Transmission System
DC Tubular Motor - FCC ID ZY4CMD02P - Coulisse B.V.
ZY4CMD02P

DC Tubular Motor

Mar 14, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver