MOTIONBLINDS MANUAL setup guide CURTAIN BLIND MOTOR CM-36 Conforms to UL Std. 325 Certified to CSA Std. C22.2#247 Cleaning Follow these general rules when cleaning the outside of the device and its components: Use a damp, soft, lint-free cloth. Avoid getting moisture in openings. Do not use aerosol sprays, solvents, alcohol, or abrasives. Service & Support Do not perform repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Warranty Service First follow the advice in this manual. If the product appears to be damaged or does not function properly, go to your local dealer for instructions on how to obtain warranty service. Recycle This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collec-tion systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Read the instructions carefully before assembling and using the product. Assembly can be completed by non-professionals. For indoor use only. Young children can strangle themselves with the loop of pull cords, chains and tapes, and cords that operate window coverings. To avoid strangulation and entanglement, keep cords out of reach of young children. Cords may ensnare a child’s neck. Move beds, cots and furniture away from window covering cords. Do not tie cords together. Make sure cords do not twist together and form a loop. WARNING 2 Important Safety instructions WARNING: To reduce the risk of severe injury or death, it is important to follow these instructions for personal safety. Save these instructions. Read and follow all installation instructions. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should not play with the appliance. Cleaning and user maintenance should not be performed by children without supervision. Do not allow children to play with fixed controls. Keep remote controls away from children. Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do not use if repair or adjustment is necessary. This instruction manual is also available on the website. The drive must be disconnected from its power source during cleaning, maintenance and when replacing parts. The A-weighted emission sound pressure level of the drive is equal to or less than 70dB(A). Indoor and household use only. Disconnect the drive from the power supply or switch off the automatic controls when maintenance, such as window cleaning, is being carried out in the vicinity. When operating a biased switch, make sure that other persons are kept away. Do not operate when maintenance, such as window cleaning, is being carried out in the vicinity. The tube motor must only be supplied with safety extra low voltage corresponding to the marking on the appliance. Important Installation instructions WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury. This motor can only be used with soft material for driven parts. Hazardous unprotected moving parts of the drive must be installed higher than 2.5m above the floor or any other level surface that could provide access to it. Install the actuating member of a manual release at a height less than 1.8m. The actuating member of a biased switch is to be located within direct sight of the driven part but away from moving parts. It is to be installed at a minimum height of 1.5m and not accessible to the public. The mass and the dimension of the driven part must be compatible with the rated torque and rated operating time. Fixed controls have to be clearly visible after installation. The driven part must be compatible with the rated torque (1.2N.m) and rated operating time (12 min). The drive is intended to be installed at a height of at least 2.5m above the floor or any other accessible level surface. All-pole disconnection switches must be incorporated in the fixed wiring in accordance with the wiring rules. The appliance must only be supplied at safety extra low voltage corresponding to the marking on the appliance. Before installing the drive, remove any unnecessary cords or components and disable any equipment not needed for powered operation. 3 ENGLISH FCC Manual FCC ID: ZY4CM36B Regulatory Information 1 FCC Information for User This product does not contain any user serviceable components and is to be used with approved antennas only. Any product changes or modifications will invalidate all applicable regulatory certifications and approvals. 2 FCC Electronic Emission Notices This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. 3 FCC Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residenti…
Text truncated - open the document above for the full version.
Coulisse B.V. Vonderweg 48, Enter, 7468 DC, Netherlands To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04/07/2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: ZY4CM36B [Coulisse B.V.] (“the applicant”) certifies that, as of the date of the filing of the application, (Americas Compliance Consulting, LLC dba iCertifi) is our designated U.S. agent for service of process for the above referenced FCC ID. [Coulisse B.V.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (Americas Compliance Consulting, LLC dba iCertifi) accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: FRN: 0033399411 Name: Americas Compliance Consulting, LLC dba iCertifi Address: 1001 SW Disk Drive, Suite 250 Bend, Oregon 97702 USA Contact Person: Paul Preston Tel.: (866) 885-4575 Email: [email protected] Sincerely, U.S. agent company name Americas Compliance Consulting, LLC dba iCertifi U.S. agent company name printed name Paul Preston U.S. agent company name signature Applicant name Coulisse B.V. Applicant printed name Bas Klein Tuente Applicant signature
Coulisse B.V. Vonderweg 48, Enter, 7468 DC, Netherlands Date (01/03/2023) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: ZY4CM36B Dear Sir or Madam, [Coulisse B.V.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [Coulisse B.V.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List ( as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment . If you have any questions, please contact us. Sincerely, Company Name: Coulisse B.V. Company Officer: Manager Engineering / Bas Klein Tuente Telephone Number: +31 547855555 Email: [email protected]
Coulisse B.V. Vonderweg 48, Enter, 7468 DC, Netherlands Declaration of Antenna combination To whom it may concern, Product name: DC CURTAIN MOTOR Models: CM-36 FCC ID: ZY4CM36B We declared that the Bluetooth uses an external antenna via IPEX port, which is realized by R2 vacant and R3 connected to 0ohm resistor, and the on-board antenna is blocked and not used. R2=0ohm & R3=NC, uses on board antenna R2=NC & R3=0ohm, uses external antenna via IPEX port Yours sincerely, Company Name: Coulisse B.V. Company Officer: Manager Engineering / Bas Klein Tuente Telephone Number: +31 547855555 Email: [email protected]
Coulisse B.V. Vonderweg 48, Enter, 7468 DC, Netherlands Date (01/03/2023) TUV SUD BABT UNLIMITED TCB Octagon House, Concorde Way, Segensworth North, Freham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: ZY4CM36B Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Coulisse B.V.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation (Coulisse B.V.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180) days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Name: Coulisse B.V. Company Officer: Manager Engineering / Bas Klein Tuente Telephone Number: +31 547855555 Email: [email protected]
Page 1 of 3 External Photos for CM-36 Details of: Front view Details of: Rear view Page 2 of 3 Details of: Side view Details of: Side view Page 3 of 3 Details of: End cap view Details of: DC inlet view
538-77-03 DT980LE/CB-1.2/14 (MOTION 蓝牙系列) 备注 538-77-03 538# 100*28mm(长*宽) UV油墨 黑白印刷 A-01 2022.9.13 贴产品 方肖酉 魏娟 校对 设计 适用产品 材 质 油 墨 是否覆膜 印刷工艺 是否含流水码 或条形码 审定 版本 日期 制图 颜 色 尺 寸0.1±0.01mm(厚度) 使用规范 工艺描述 客户号 杜亚机电 铭牌 JS-6-15 C:0% M:0% Y:0% K:100% 图纸认证说明 (此尺寸为本图内1:1尺寸) 5mm 7mm 7mm 5mm 符合:ROHS REACH法规要求 覆光膜 进口透明材质 Nmcm/smin Conforms to ANSI/CAN/UL Std.325 stick on the enclosure
Page 1 of 5 Internal Photos for CM-36 Details of: Internal view Details of: Internal view Page 2 of 5 Details of: PCB view 1 Details of: PCB view 1 433.925MHz ANT Page 3 of 5 Details of: PCB view 2 Details of: PCB view 2 BT ANT Page 4 of 5 Details of: PCB view after disassembly Details of: PCB view after disassembly Page 5 of 5 Details of: Motor view Details of: Motion sensor view
Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 8 FCC Maximum Permissible Exposure (MPE) Report Report Number : 68.910.22.0028.01A Date of Issue: 2023-04-14 Model / HVIN : CM-36 Product Type : Tubular Motor Applicant : Coulisse B.V. Address : Vonderweg 48, Enter, 7468 DC, Netherlands Manufacturer : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd. Address : No.168 Shengguang Road, Luotuo, Zhenhai, 315202 Ningbo, Zhejiang province, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 8 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 8 1 Table of Contents 1 Table of Contents ................................................................................................................................................................. 2 2 Details about the Test Laboratory ..................................................................................................................................... 3 3 Description of the Equipment Under Test ........................................................................................................................ 4 4 General Information ............................................................................................................................................................. 5 5 RF Exposure Requirements ............................................................................................................................................... 6 6 FCC MPE Limits .................................................................................................................................................................... 7 7 RF Exposure Evaluation (FCC) .............................................................................................................................................. 8 7.1.1 Calculation of Power Density for Single Transmission ........................................................................................ 8 7.1.2 Calculation of Simultaneous Transmission .......................................................................................................... 8 7.1.3 Conclusion ............................................................................................................................................................ 8 Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 8 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052 China FCC Designation Number: CN5009 FCC Registration No.: 514049 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 8 3 Description of the Equipment Under Test Product: Tubular Motor Model no.: CM-36 FCC ID: ZY4CM36B Ratings: 14.8VDC, 16W, 1A RF Transmission Frequency: 433.925 MHz 2402MHz-2480MHz No. of Operated Channel: Single channel for 433.925 MHz 40 for 2.4GHz BLE Modulation: FSK for 433.925 MHz GFSK for 2.4GHz BLE Antenna Type: PCB Antenna for 433.925 MHz Wire Antenna for 2.4GHz BLE Antenna Gain: -4.0dBi for 433.925 MHz 2.2dBi max for 2.4GHz BLE Description of the EUT: The Equipment Under Test (EUT) is a Tubular Motor supports 2.4GHz BLE 1Mbps / 433.925MHz SRD functions. NOTE 1: The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 8 4 General Information Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Prepared By 2023-04-14 Myron Yu Project Engineer Date Name Signature Approved By 2023-04-14 Jessie He Project Manager Date Name Signature Report Number: 68.910.22.0028.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Br…
Text truncated - open the document above for the full version.
Report Number: 68.910.22.0028.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 37 FCC - TEST REPORT Report Number : 68.910.22.0028.01 Date of Issue: 2023-04-14 Model : CM-36 Product Type : DC CURTAIN MOTOR Applicant : Coulisse B.V. Address : Vonderweg 48, Enter, 7468 DC, Netherlands Manufacturer : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd. Address : No.168 Shengguang Road, Luotuo, Zhenhai, 315202 Ningbo, Zhejiang province, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 37 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation chapter A-3.4. Report Number: 68.910.22.0028.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 37 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment under Test ............................................................................... 4 4 Summary of Test Standards .................................................................................................. 5 5 Summary of Test Results....................................................................................................... 6 6 General Remarks ................................................................................................................... 7 7 Test Setups ............................................................................................................................ 8 8 Systems test configuration ................................................................................................... 10 9 Technical Requirement ........................................................................................................ 11 9.1 Conducted Emission ..................................................................................................... 11 9.2 Conducted output power ............................................................................................... 14 9.3 6dB bandwidth .............................................................................................................. 16 9.4 99% Occupied Bandwidth ............................................................................................. 18 9.5 Power spectral density .................................................................................................. 20 9.6 Spurious RF conducted emissions ............................................................................... 22 9.7 Band edge .................................................................................................................... 27 9.8 Spurious radiated emissions for transmitter .................................................................. 29 10 Test Equipment List ......................................................................................................... 36 11 System Measurement Uncertainty ................................................................................... 37 Report Number: 68.910.22.0028.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 37 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052 China FCC Designation Number: CN5009 FCC Registration No.: 514049 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.910.22.0028.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 37 3 Description of the Equipment under Test Product: DC CURTAIN MOTOR Model no.: CM-36 FCC ID: ZY4CM36B Ratings: 14.8VDC, 16W, 1A RF Transmission Frequency: 2402MHz-2480MHz No. of Operated Channel: 40 Modulation: GFSK Antenna Type: Wire Antenna Antenna Gain: 2.2dBi max for 2.4GHz BLE Description of the EUT: The Equipment Under Test (EUT) is a DC CURTAIN MOTOR supports 2.4GHz BLE 1Mbps / 433.925MHz SRD functions. Report Number: 68.910.22.0028.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 37 4 Summary of Test Standards Test Standards FCC Part 15 Subpart C 10-1-2021 Edition PART 15 - RADIO FREQUENCY DEVICES Subpart C - Intentional Radiators All the test methods were according to KDB558074 D01 v05r02 DTS Measurement Guidance and ANSI C63.10 (2013). Report…
Text truncated - open the document above for the full version.
Page 1 of 2 Test Setup Photos for CM-36 Conducted Emission test Radiated Emission test (30MHz to 1000MHz) Page 2 of 2 Radiated Emission test (1000MHz to 18000MHz) Radiated Emission test (Above 18000MHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 770.00 µW |

Motionblinds Wifi Matter Bridge
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
hand-held remote with 5 channels for operating and programming blinds
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Honeycomb Motor
Equipment Class
DTS - Digital Transmission System
DC Tubular Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver