Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03/05/24 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID:2AEBL-M2249 ABB Xiamen Smart Technology Co.,Ltd. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. ABB Xiamen Smart Technology Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 2445 NE Division St, ste 202 Bend, OR 97703, United States Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, ABB Xiamen Smart Technology Co.,Ltd. FRN: 0024378689 Americas Compliance Consulting LLC dba iCertifi Shanshan, Wang Paul Preston Signature
Date: 2024-03-05 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2AEBL-M2249 Dear Sir or Madam, [ABB Xiamen Smart Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [ABB Xiamen Smart Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List ( as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment . If you have any questions, please contact us. Sincerely, Signature: Contact name: Testing & Laboratory Specialist / Shanshan, Wang Company name: ABB Xiamen Smart Technology Co., Ltd. Address: 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA E-mail: [email protected] Tel: 0592-7616016
Date (2024-03-05) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2AEBL-M2249 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (ABB Xiamen Smart Technology Co., Ltd.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation (ABB Xiamen Smart Technology Co., Ltd.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Signature: Contact name: Testing & Laboratory Specialist / Shanshan, Wang Company name: ABB Xiamen Smart Technology Co., Ltd. Address: 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA E-mail: [email protected] Tel: 0592-7616016
Date: 2024-03-05 Subject: Statement to disable all the Bluetooth function by software FCC ID: 2AEBL-M2249 IC: 20060-M2249 To Whom It May Concern: We (ABB Xiamen Smart Technology Co., Ltd.) hereby declare that all the Bluetooth function of wireless module AW-CM256SM and the Bluetooth 5.1/Thread function of wireless module EFR32MG21A010F1024IM32-BR were disabled by software in the factory, this setting is not accessible and can’t be activated by the user or any other third-party. Best Regards Signature: Contact name: Testing & Laboratory Specialist / Shanshan, Wang Company name: ABB Xiamen Smart Technology Co., Ltd. Address: 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA E-mail: [email protected] Tel: 0592-7616016
Date: 2024-03-05 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2AEBL-M2249 To Whom It May Concern: This letter is to ascertain that ABB Xiamen Smart Technology Co., Ltd. Product name: ABB OneTouch 7, Model: M2249-2. has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Signature: Contact name: Testing & Laboratory Specialist / Shanshan, Wang Company name: ABB Xiamen Smart Technology Co., Ltd. Address: 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA E-mail: [email protected] Tel: 0592-7616016
V1.1
Report Number: 68.950.24.0062.01-S EMC_SZ_FR_84.00 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 9 FCC Maximum Permissible Exposure (MPE) Estimation Report Report Number : 68.950.24.0062.01-S Date of Issue: 2024-01-29 Model / HVIN : M2249-2. Product Type : ABB OneTouch 7 Applicant : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Manufacturer : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 9 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.950.24.0062.01-S EMC_SZ_FR_84.00 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 9 1 Table of Contents 1 Table of Contents ...................................................................................................................................................2 2 Details about the Test Laboratory ..........................................................................................................................3 3 Description of the Equipment Under Test ..............................................................................................................4 4 Test Specifications .................................................................................................................................................5 5 General Information ...............................................................................................................................................6 6 RF Exposure Requirements ...................................................................................................................................7 7 FCC MPE Limits.....................................................................................................................................................8 8 RF Exposure Evaluation (FCC) .............................................................................................................................9 8.1.1 Calculation of Power Density for Single Chain Transmitters ................................................................9 8.1.2 Calculation of Simultaneous Transmission ...........................................................................................9 8.1.3 Conclusion .............................................................................................................................................9 Report Number: 68.950.24.0062.01-S EMC_SZ_FR_84.00 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 9 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 Report Number: 68.950.24.0062.01-S EMC_SZ_FR_84.00 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 9 3 Description of the Equipment Under Test Product: ABB OneTouch 7 Model no.: M2249-2. FCC ID: 2AEBL-M2249 Options and accessories: NIL Ratings: 24VDC, 400mA RF Transmission Frequency: 2412MHz - 2462MHz for 2.4GHz Wi-Fi; 2405MHz - 2480MHz for 2.4GHz Wireless; 5180MHz – 5320MHz, 5500MHz – 5700MHz, 5745MHz – 5825MHz for 5GHz Wi-Fi (This device shall not be capable of transmitting in the band 5600-5650 MHz. This restriction is for the protection of Terminal Doppler Weather Radar (TDWR) operating in this band.) No. of Operated Channel: 11 for 2.4GHz Wi-Fi; 16 for 2.4GHz Wireless; 43 for 5GHz Wi-Fi Modulation: 802.11b: BPSK, QPSK, CCK 802.11g: BPSK, QPSK, 16-QAM, 64-QAM 802.11a: BPSK, QPSK, 16-QAM, 64-QAM 802.11n: BPSK, QPSK, 16-QAM, 64-QAM 802.11ac: BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM 2.4GHz Zigbee: OQPSK Antenna Type: Integrated FPC antenna Antenna Gain: 4.5 dBi for 2.4GHz Wi-Fi 3.2 dBi for 2.4GHz Wireless 5.3 dBi for 5GHz Wi-Fi Description of the EUT: The EUT is an ABB OneTouch 7 supports Wi-Fi and Zigbee functions: 2412MHz - 2462MHz for 2.4GHz Wi-Fi; 5180MHz – 5320MHz, 5500MHz – 5700MHz, 5745MHz – 5825MHz for 5GHz Wi-Fi; 2405MHz - 2480MHz 2.4GHz Wireless. Report Number: 68.950.24.0062.01-S EMC_SZ_FR_84.00 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998,…
Text truncated - open the document above for the full version.
东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2023/09/19 编号 File No 23091902 版本 Revision 1.0 Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz Impedance50 Ohm Nominal V.S.W.R2.0 Max Gain 4.0 dBi Spec >44.6 % RadiationOmni-directional PolarizationLinear Physical Properties Connector IPEX Cable TypeO.D.1.13mm Cable Length65mm Cable Colo rBlack Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity-40 ~ +85 ̊C / 5%-95% Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Antenna Performance Test Agilent Antenna Performance Te s t Agilent E5071B S11S11 Parameter Test // BT Antenna Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 AntennaPassive TestAntenna Passive Te s t Z Z Y XX Y X Z Y Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Passive Test For BT Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 2400 47.8 -3.2 2.0 2410 46.5 -3.3 2.1 2420 48.1 -3.2 2.1 2430 48.5 -3.1 2.0 2440 48.5 -3.1 2.3 2450 50.1 -3.0 2.4 2460 47 0-33 2.5 47.0 -3.3 2470 45.7 -3.4 2.8 2480 44.6 -3.5 3.2 2490 46.6 -3.3 4.0 2500 46.9 -3.3 3.9 Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For BT Antenna(2450MHz) Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086
东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2023/07/22 编号 File No 23072201 版本 Revision 1.0 Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz 5155 85GHz qy 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R2.0 Max Gi [email protected] Gain 4.5 [email protected] 2.5GHz 5.3 [email protected] RadiationOmni-directional PolarizationLinear Physical Properties Connector IPEX Cable TypeO.D.1.13mm Cable Length70mm Cable ColorBlack Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Antenna Performance Test Agilent Antenna Performance Te s t Agilent E5071B S11S11 Parameter Test // WIFI Antenna Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 AntennaPassive TestAntenna Passive Te s t Z Z Y XX Y X Z Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Y Passive Test For WIFI Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 2400 47.5 -3.2 3.2 2410 46.4 -3.3 3.2 2420 49.2 -3.1 3.2 2430 49.8 -3.0 3.2 2440 51.2 -2.9 3.6 2450 53.7 -2.7 4.2 2460 51.2 -2.9 4.2 2470 51.1 -2.9 4.4 2480 49.6 -3.0 4.5 Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 2490 50.0 -3.0 4.5 2500 48.3 -3.2 4.4 Passive Test For WIFI Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 5150 42.9 -3.7 4.1 5200 42.4 -3.7 3.6 5250 41 9-3835 5250 41.9 3.8 3.5 5300 40.1 -4.0 2.6 5350 40.7 -3.9 2.8 5400 50.8 -2.9 3.3 5450 58.6 -2.3 3.5 5500 52.5 -2.8 3.7 5550 55.3 -2.6 4.1 5600 57.3 -2.4 4.3 5650 55.0 -2.6 3.6 5700 51.7 -2.9 4.3 5750 56 1-2553 Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 5750 56.1 -2.5 5.3 5800 57.6 -2.4 3.9 5850 56.1 -2.5 4.2 Radiation Pattern For WIFI Antenna(2450MHz) Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WIFI Antenna(5150MHz) Address: No. Muyu Road, Shatou District, Chang'an Town, Dongguan City, Guangdong Tel:0769-82586086 Fax:0769-82586086
Report Number: 68.760.24.0059.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 57 FCC/ISED - TEST REPORT Report Number : 68.760.24.0059.01 Date of Issue: 2024-01-29 Model/HVIN : M2249-2. Product Type : ABB OneTouch 7 Applicant : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Manufacturer : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 56 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation chapter A-3.4. Report Number: 68.760.24.0059.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 57 1 Table of Contents 1 Table of Contents ...................................................................................................................................................2 2 Details about the Test Laboratory ..........................................................................................................................3 3 Description of the Equipment Under Test ..............................................................................................................4 4 Summary of Test Standards ..................................................................................................................................5 5 Summary of Test Results .......................................................................................................................................6 6 General Remarks ...................................................................................................................................................7 7 Test Setups ............................................................................................................................................................8 7.1 Radiated test setups .......................................................................................................................................8 7.2 Conducted RF test setups ..............................................................................................................................9 7.3 AC Power Line Conducted Emission test setups ...........................................................................................9 8 Systems test configuration .................................................................................................................................. 10 9 Technical Requirement ....................................................................................................................................... 11 9.1 Conducted Emission .................................................................................................................................... 11 9.2 Conducted Output Power & EIRP ............................................................................................................... 14 9.3 6 dB and 99% Bandwidth ............................................................................................................................ 15 9.4 Power spectral density ................................................................................................................................. 27 9.5 Spurious RF conducted emissions .............................................................................................................. 33 9.6 Band edge testing ........................................................................................................................................ 43 9.7 Spurious radiated emissions for transmitter ................................................................................................ 47 10 Test Equipment List ......................................................................................................................................... 56 11 System Measurement Uncertainty .................................................................................................................. 57 Report Number: 68.760.24.0059.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 57 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 ISED CAB identifier: CN0077 IC Registration No.: 10320A Report Number: 68.760.24.0059.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Gua…
Text truncated - open the document above for the full version.
Report Number: 68.760.24.0060.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 43 FCC / ISED- TEST REPORT Report Number : 68.760.24.0060.01 Date of Issue: 2024-01-29 Model : M2249-2. Product Type : ABB OneTouch 7 Applicant : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Manufacturer : ABB Xiamen Smart Technology Co., Ltd. Address : 4th Floor, No. 881, FangShanXiEr Road, Xiang’An Industrial Area, Torch Hi-Tech Industrial Development Zone, 361000 Xiamen S.E.Z, Fujian Province, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 43 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.760.24.0060.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 43 1 Table of Contents 1 Table of Contents ................................................................................................................................................................ 2 2 Details about the Test Laboratory ..................................................................................................................................... 3 3 Description of the Equipment under Test ........................................................................................................................ 4 4 Summary of Test Standards .............................................................................................................................................. 5 5 Summary of Test Results ................................................................................................................................................... 6 6 General Remarks ................................................................................................................................................................ 7 7 Test Setups .......................................................................................................................................................................... 8 7.1 Radiated test setups .................................................................................................................................................. 8 7.2 Conducted RF test setups ......................................................................................................................................... 8 7.3 AC Power Line Conducted Emission test setups .................................................................................................. 9 8 Systems test configuration ............................................................................................................................................... 10 9 Technical Requirement .................................................................................................................................................... 11 9.1 Conducted Emission ................................................................................................................................................ 11 9.2 Conducted peak output power & EIRP ................................................................................................................. 14 9.3 6dB bandwidth .......................................................................................................................................................... 17 9.4 99% bandwidth ......................................................................................................................................................... 20 9.5 Power spectral density ............................................................................................................................................. 23 9.6 Spurious RF conducted emissions ........................................................................................................................ 26 9.7 Band edge ................................................................................................................................................................. 31 9.8 Spurious radiated emissions for transmitter ......................................................................................................... 33 10 Test Equipment List ...................................................................................................................................................... 42 11 System Measurement Uncertainty ............................................................................................................................. 43 Report Number: 68.760.24.0060.01 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 43 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 4.23 mW |

Smart Access Point Pro with Wi-Fi and Bluetooth
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Video indoor station 4.3 with 802.11b/g/n
Equipment Class
DTS - Digital Transmission System
Standalone Transponder module of Card Reader
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Pushbutton module, with NFC/IC card reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Mini video outdoor station
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter