FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. The Genie Company a Division of Overhead Door Corporation/
  3. B8Q-915LR

B8Q-915LRDoor Remote

The Genie Company a Division of Overhead Door Corporation
Door Remote - FCC ID B8Q-915LR - The Genie Company a Division of Overhead Door Corporation
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 31, 2011
Application Purpose
Original Equipment
Date of Application
Mar 31, 2011
Equipment Note
Door Remote
Frequency Range
903.94000000 - 925.60000000
Company
The Genie Company a Division of Overhead Door Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ATTENTION: Your garage door opener must have a Serial 10 or higher. MODEL AC SR3THE GENIE COMPANY FCC ID: B8Q AC SR3Residential Door Operator IC: 2133A-CSD1D120V. 60HZ. 5A FOR HELP CALL 1-800-275-6187 W WW.OVERHEADDOOR.COM S/N:10XXXXXXXXXXXX CLose Confirm™ Remote CLose Confirm™ a distancia CLose Confirm™ Remote Installation and Operation One Close Confirm™ Remote can operate up to 3 openers or can be program- med to use one, two, or three buttons to operate a single opener. Each opener intended to be run by the Close Confirm™ Remote must have a Network Adapter installed to receive signals from the Close Confirm™ Remote. If you do not have or need more Network Adapters, contact your Genie dealer. To use the Close Confirm™ Remote (with a Network Adapter), the powerhead must have this type of label and be equipped with the connection port (See. STEP 2 below). If your powerhead does not meet these criteria—DO NOT attempt to install this product. Close Confirm™ Remote connection pins Network Adapter (may or may not be included) Number sticker that looks like this, in which the first two numbers are Buttons LED Close Confirm™ Remote LED Close Confirm™ a distancia LED Part Number: 37383500131 01-2011 ©2010 GMI Holdings, Inc. DBA The Genie Company Latch FOR FUTURE REFERENCE: When batteries become weak. Move the latch toward the cover on back of the transmitter and lift the cover off. Replace batteries with new “AAA” type. Proper orientation is shown on the circuit board below the batteries. Replace cover. + AAA - + AAA - Loquet POUR L'AVENIR DE REFERENCE: Lorsque les piles deviennent faibles. Déplacez le loquet vers le couvercle sur arrière de l'émetteur et soulevez le couvercle. Remplacez les piles par de nouvelles Type "AAA". Bonne orientation est représenté sur le circuit ci-dessous les piles. Remettre le couvercle. + AAA - + AAA - Pestillo PARA FUTURA REFERENCIA: Cuando las baterías se debilitan. Mueva el seguro hacia la cubierta parte posterior del transmisor y levante la cubierta. Reemplace las baterías con las nuevas "AAA" de tipo. La orientación adecuada se muestraen el circuito por debajo de las pilas. Vuelva a colocar la cubierta. + AA A - + AAA - Installation et utilisation Pour programmer et utiliser la télécommande Close Confirm™ (avec un adaptateur de réseau), la tête motorisée doit disposer de ce type d’étiquette et être un ouvre-porte compatible. Si votre tête motorisée ne dispose par de l'étiquette ni d'un système d'entraînement de ce type, NE PAS installer ce produit. Instalación y funcionamiento Para programar y utilizar el Remoto de la Close Confirm™ (con un Adaptador de red), la caja de control debe tener este tipo de etiqueta y debe ser un abridor compatible. Si su caja de control no tiene una etiqueta y el sistema motriz de este tipo, NO intente instalar este producto. Une télécommande Close Confirm™ peut faire fonctionner 3 ouvre-portes maximum ou peut être programmée pour utiliser une, deux ou trois boutons pour faire fonctionner un ouvre-porte. Les ouvre-portes censés être utilisés avec la télécommande Close Confirm™ doivent disposer d’un adaptateur de réseau installé pour recevoir les signaux émis par la télécommande Close Confirm™. Si vous ne disposez pas d’adaptateur de réseau ou si vous avez besoin d'un plus grand nombre d'adaptateur de réseau, contactez votre revendeur d'Genie. Un Close Confirm™ Remoto puede funcionar hasta con 3 abridores o puede ser programado para usar con uno, dos o tres botones para que funcione un solo abridor. Para que cada abridor funcione con el Close Confirm™ Remoto, debe tener un Adaptador de red instalado para recibir las señales del Close Confirm™ Remoto. Si usted no tiene o necesita más adaptadores de red, comuníquese con su agente de Puertas Elevadizas (Genie). ATTENTION: MODÈLE AC SR3 FCC ID :B8Q AC SR3Portier électrique résidentiel IC :2133A-CSD1D 120 V 60 Hz 5 A N/S : 10XXXXXXXXXXXX Votre ouvre-boîtes de porte de garage doit avoir un autocollant de numéro de série quia l’air de ceci, dans l equel le premier deux nombres est 10 ou plus haut. THE GENIE COMPANY PARA OBTENER AYUDA LLAME AL NÚMERO 1-800-35GENIE O INGRESE A L SITIO WE B WWW.OVERHEADDOOR.COM MODÈLE AC SR3 FCC ID :B8Q AC SR3Portier électrique résidentiel IC :2133A-CSD1D 120 V 60 Hz 5 A N/S : 10XXXXXXXXXXXX Si su abre puertas del garaje tiene una calcomanía con el número de serie que tiene esta apariencia, en la cual los primeros dos números son 10 o más altos. THE GENIE COMPANY PARA OBTENER AYUDA LLAM E AL NÚMERO 1-800-35GENIE O INGRE SE A L SITIO WE B WWW.OVERHEADDOOR.COM ATENCIÓN: For additional information or help contact Customer Care at 800-35-GENIE or visit www.geniecompany.com WARNING Moving Door can cause serious injury or death. sWall Console must be mounted in sight of door, at least 5 feet above fl oor and clear of moving door parts. s Keep people clear of opening while door is moving s Do NOT allow children to play with Remote or door opener. If safety reverse does not work properly: s Close door then disconnect opener using the manual release handle. s Do NOT use Remote or door opener. sRefer to door & door opener owner manuals before trying any repairs. Electrical Shock can cause serious injury or death. sPower cord must be unplugged before attaching any wires. sBe sure wire ends do not touch each other or other terminals. If you have questions or if you need a manual, contact the distributor or manufacturer of the opener. AVERTISSEMENT Les portes en mouvement peuvent causer des blessures graves ou la mort. sLa commande murale doit être installée à un endroit visible de la porte, à au moins 1,5 m (5 pi) du plancher et à l’écart de toute pièce mobile de la porte. sNe permettre à personne de se tenir dans l’ouverture de la porte lorsque la porte est en mouvement. sNe pas permettre aux enfants de jouer avec la télécommande ou l’ouvre-porte. Si le système d’inversion au contact ne fonctionne pas adéquatement: sFermer la porte, puis débrancher l’ouvre…

Text truncated - open the document above for the full version.

Cover Letter(s)

November 16th, 2010 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent FCC On our behalf, I appoint Nemko USA, Inc. at 802 N Kealy Avenue, Lewisville TX 75057 to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides (company name and address). Dated this 17th Day of November 20 10 Agency agreement expiration date: November 17, 2011 By: Louis Le Signature Printed Title: Compliance Engineer On behalf of : Overhead Door Corporation 2 Telephone: 214-385-7176

Cover Letter(s)

February 15, 2011 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC: B8Q‐915LR Models: GLR, OLR Request for Permanent Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held permanently confidential: • Block Diagram • Schematics • Parts List • Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Title: Compliance Engineer Louis Le Signature Printed On Behalf of: The Genie Company, a division of Overhead Door Corporation

Cover Letter(s)

February 15, 2011 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC: B8Q‐915LR Models: GLR, OLR Request for Short‐Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential up to 45 days from FCC grant date: • Internal Photos • External Photos • User’s Manual • Test Setup Photos These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Title: Compliance Engineer Louis Le Signature Printed On Behalf of: The Genie Company, a division of Overhead Door Corporation

Test Report

Nemko Applic a Equip m (E.U.T.) In Acc o Tested TESTED APPRO V Test Repo ant: ment Under ordance Wi By: BY: D ED BY: T o ort: r Test: ith: avid Light, W om Tidwell, T T 47116 Overh e TREQ 2170 F Dallas LRDS (Overh (Genie CFR 4 Indust Freque Nemk o 802 N. Lewisv Wireless Engin Telecom Direc Total Num RUS1 ead Door Center, S u French Sett , Texas 752 head )OLR e) is GLR 47, Part 15, try Canada ency Hoppi o USA Inc. . Kealy ville, Texas neer ct ber of Pag uite B tlement Roa 212 Subpart C a, RSS-210 ng Transm 75057-3 1 DATE: DATE: ges: 35 ad C, 15.247 & 0 itters 136 03 J 31 M & June 2010 March 2011 Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 2 of 35 Table of Contents SECTION 1. SUMMARY OF TEST RESULTS 3 SECTION 2. EQUIPMENT UNDER TEST (E.U.T.) 6 SECTION 3. CHANNEL SEPARATION 7 SECTION 4. TIME OF OCCUPANCY 10 SECTION 5. PEAK POWER OUTPUT 13 SECTION 6. SPURIOUS EMISSIONS (ANTENNA CONDUCTED) 14 SECTION 7. SPURIOUS EMISSIONS (RADIATED) 18 SECTION 8. RECEIVER SPURIOUS EMISSIONS 22 SECTION 9. TEST EQUIPMENT LIST 24 ANNEX A - TEST DETAILS 25 ANNEX B - TEST DIAGRAMS 34 Nemko EQUIPM Sectio Manufac Model N Variants Serial N General These t demons Canada tests we made on and Indu THE F Nemko US This report m o USA, In MENT: L R n 1. cturer: No.: s: o.: : tests were trating com RSS-210, ere conduc n an open ustry Canad New Class Famil THIS T FOLLOWING A, Inc. authorize must not be used c. FREQU RDS Summa Overhead LRDS GENIE B Overhea d Products None All meas e conducte mpliance w Issue 7 for cted is acc area test s da. Submissio n s II Permiss ly Listing TEST REPO G DEVIATIO TEST S es the above nam d to claim produc Governmen CFR UENCY HO Pa ary of Tes d Door rand LRDS d Brand LR are identic urements d on a sa with Part 15 r Frequency ordance w site. A desc n sive Change ORT RELAT ONS FROM, SPECIFICAT See “ Summ med company to the comp a ct certification, ap nt. Nemko USA, R 47, Part 1 OPPING SP ge 3 of 35 st Results S - Model #3 RDS - Mode al except fo are tracea ample of 5, Subpart y Hopping with ANSI C cription of th e ES ONLY T ADDITIONS TIONS HAVE mary of Test reproduce this re any’s employees pproval, or endor Inc. is a NVLAP 5.247 and PREAD SP PR s 36992R wh el #37451R or logo. able to nati the equipm C, Paragr Spread Sp C63.4-2003 he test faci P P O THE ITEM S TO, OR E E BEEN MA t Data”. eport provided it only. rsement by NVLA accredited labor Industry Ca ECTRUM T ROJECT NO hich is GLR which is O onal stand ment for t raph 15.24 ectrum dev 3. Radiated lity is on fi l Production Pre-Product M(S) TESTE EXCLUSION ADE. is reproduced in AP, NIST, or any ratory. anada RSS TRANSMIT O.: 47116R R LR dards. the purpos 47 and Ind vices. Rad d emissions le with the Unit tion Unit ED. S FROM T H n its entirety, for u y agency of the F S-210 TTER RUS1 se of ustry iated s are FCC HE use by Federal Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 4 of 35 Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko USA, Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 5 of 35 Summary of Test Data NAME OF TEST PARA. NO.RESULT Powerline Conducted Emissions 15.207(a) / RSS-Gen 7.2.2NA Channel Separation 15.247(a)(1) / RSS-210 8.1(b) Complies Time of Occupancy 15.247(a)(1) / RSS-210 8.1(c) Complies 20 dB Occupied Bandwidth 15.247(a)(1) / RSS-210 8.1(b) Complies Peak Power Output 15.247(b) / RSS-210 8.4(1)Complies Spurious Emissions (Antenna Conducted) 15.247(d) / RSS-210 8.5 Complies Spurious Emissions (Radiated) 15.247(d) / RSS-Gen 7.2.3Complies Receiver Spurious Emissions RSS-Gen 7.2.3Complies Footnotes: The EUT is battery powered. Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 6 of 35 Section 2. Equipment Under Test (E.U.T.) General Equipment Information Frequency Band: 902 – 928 MHz 2400 – 2483.5 MHz 5725 – 5850 MHz Operating Frequency Range: 903.94 to 925.60 MHz Input Power: 3 Vdc Number of Channels: 51 20 dB Bandwidth: 81.7 kHz Channel Spacing: 380 kHz User Frequency Adjustment: Software controlled Description of EUT Wireless Remote Controller with 3 Buttons and AAA (2) Battery Power Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 7 of 35 Section 3. Channel Separation NAME OF TEST: Channel Separation PARA. NO.: 15.247(a)(1) RSS-210 8.1(b) TESTED BY: David Light DATE: 02 June 2010 Test Results: Complies. Measurement Data: See 20 dB BW plot Measured 20 dB bandwidth: 81.7 kHz Channel Separation: 380 kHz Equipment Used: 1464-1082-1472 Measurement Uncertainty: 1X10 -7 ppm Temperature: 22 °C Relative Humidity: 35 % Nemko EQUIPM Test Da Test Da Low Ch a o USA, In MENT: L R ta – Chann ta – 20 dB annel c. FREQU RDS nel Separat Bandwidth CFR UENCY HO Pa tion h R 47, Part 1 OPPING SP ge 8 of 35 5.247 and PREAD SP PR Industry Ca ECTRUM T ROJECT NO anada RSS TRANSMIT O.: 47116R S-210 TTER RUS1 Nemko EQUIPM Test Da Mid Ch a High Ch o USA, In MENT: L R ta – 20 dB annel hannel c. FREQU RDS Bandwidth CFR UENCY HO Pa h R 47, Part 1 OPPING SP ge 9 of 35 5.247 and PREAD SP PR Industry Ca ECTRUM T ROJECT NO anada RSS TRANSMIT O.: 47116R S-210 TTER RUS1 Nemko USA, Inc. CFR 47, Part 15.247 and Industry Canada RSS-210 FREQUENCY HOPPING SPREAD SPECTRUM TRANSMITTER EQUIPMENT: LRDS PROJECT NO.: 47116RUS1 Page 10 of 35 Section 4. Time…

Text truncated - open the document above for the full version.

Test Setup Photos

Applicant Name: The Genie Company Product Name: Door Remote ( GLR, OLR) Certification Number: (FCC ID or IC:) FCC ID: B8Q-915LR IC: 2133A-915LR Project NEX 151655 Evaluation with and without housing configurations have been conducted and the current without housing configuration is the worst case of emission configuration, therefore the compliance of emission for the final product is confirmed

Contact Information

Applicant

Mike Whitley(RF Engineer)
[email protected]830-660-0800Fax: 330-763-8011

Technical Contact

The Genie CompanyLouis Le
[email protected]214 593 0049

2170 French Settlement Road · Dallas, Texas · United States

Non-Technical Contact

Nemko USA, Inc.Lina Kwee Nguyen
[email protected]469-877-6150

Test Firm

Nemko Dallas, Inc.Mike Cantwell
[email protected]972-436-9600Fax: 972-436-2667

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903.94 MHz - 925.6 MHz11.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted.

Other Applications from The Genie Company a Division of Overhead Door Corporation

Door COntrol Module - FCC ID B8QALDCM2 - The Genie Company a Division of Overhead Door Corporation
B8QALDCM2

Door COntrol Module

Jun 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
B8QALDPS2

Door Position Sensor

May 29, 2026

Equipment Class

DTS - Digital Transmission System
Universal 2 Button Transmitter - FCC ID B8QU2 - The Genie Company a Division of Overhead Door Corporation
B8QU2

Universal 2 Button Transmitter

Jul 11, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Universal Wireless Wall Console - FCC ID B8QUWWC - The Genie Company a Division of Overhead Door Corporation
B8QUWWC

Universal Wireless Wall Console

Mar 22, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
1 Button Transmitter - FCC ID B8Q1BTX - The Genie Company a Division of Overhead Door Corporation
B8Q1BTX

1 Button Transmitter

Sep 15, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter