FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. The Genie Company a Division of Overhead Door Corporation/
  3. B8Q1BTX

B8Q1BTX1 Button Transmitter

The Genie Company a Division of Overhead Door Corporation
1 Button Transmitter - FCC ID B8Q1BTX - The Genie Company a Division of Overhead Door Corporation
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 15, 2020
Application Purpose
Original Equipment
Date of Application
Sep 02, 2020
Equipment Note
1 Button Transmitter
Frequency Range
390.00000000 - 390.00000000
Company
The Genie Company a Division of Overhead Door Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

41360.00092, 02/20 Current Production Openers 1. Press and hold the program button until the round LED turns blue, then release. PROGRAM SET + PROGRAM SET + 2. The round LED will go out and the long LED will begin flashing purple. 3. Proceed to STEP 2. 4. Press desired remote control button 3 times slowly until door operates. Openers manufactured between 1995 to 2011 and all external receivers. (LEARN CODE TYPE) RADIO SIGNAL LEARN CODE CODE LEARN SET SET OPEN FORCE CLOSECODE LEARNLIMITMANUAL or RADIO SIGNAL LEARN CODE RADIO SIGNAL LEARN CODE NOTE: Learn Code Buttons are normally located under lens covers on earlier models. NOTE: The openers LEARN MODE will time out in 30 seconds. Programming must be completed within 30 seconds. PROGRAM SET + PROGRAM SET + Pull protective tab to activate remote STEP 1: PLACE CURRENT PRODUCTION RESIDENTIAL OPENER INTO PROGRAMMING MODE FCC Part 15.21 Statement: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC / IC Statement: This device complies with FCC Part 15 and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. PRGM SET TYPE 1TYPE 2TYPE 3 There are 4 types of programming button pads. Type 1 is shown in these steps. All buttons perform the same function and programming is the same for all types shown above. Place operator into programming mode: TYPE 1-2-3-4 + PRGM SET + – PRGM SET + – PRGM SET + – TYPE 4 WARNING ! Moving Door can cause serious injury or death. • Wall Console must be mounted in sight of door, at least 5 feet above floor and clear of moving parts. • Keep people clear of opening while door is moving. • DO NOT allow children to play with the remote or door opener. If SAFETY REVERSE does not work properly: • Close door then disconnect opener using the manual release handle. • Refer to Door and Door Openers Owners Manuals before attempting any repairs. Adding a SINGLE (1-2-3-4 Button) Transmitter 1. If operator is in RUN mode, press CAL/RUN key to enter calibration mode. 2. Press SCROLL (up or down) until display reads “LEARN NEW XMTR? ” Fig.1 • This question along with the instruction “HIT SET FOR YES” will continuously pan across the display window. (Pressing SCROLL or CAL/RUN will cancel the operation.) 3. Press SET/CLEAR . • Display will read “PUSH XMTR BUTTON TWO TIMES TO LEARN XMTR.” 4. Press Transmitter button two times. • The display will read “XMTR ___LEARNED.” Where it assigns a random number to the transmitter. That transmitter is entered and ready to operate the door. (Label the transmitter with this number.) 5. Press SCROLL (up or down) to move on to another menu item, or CAL/RUN to exit the CAL mode. OPEN CLOSE STOP CAL RUN SCROLL SCROLL SET CLEAR LEARN NEW XMTR? Fig. 1 AVERTISSEMENT UNE PORTE EN MOUVEMENT PEUT CAUSER DE GRAVES BLESSURES, VOIRE LA MORT. N’installez PAS le transmetteur à moins que l’appareil de sécurité du dispositif de fermeture de porte ne fonctionne conformément au manuel du dispositif de fermeture de porte. La console murale doit être montée à la vue de la porte, à au moins 5 pieds au-dessus du sol et il ne doit y avoir aucune pièce de porte en mouvement à proximité. • Éloignez les gens de l’ouverture lorsque la porte est en mouvement. • NE permettez PAS aux enfants de jouer avec le transmetteur ou le dispositif de fermeture de porte. Si l’inversion de sécurité ne fonctionne pas correctement : • Fermez la porte, puis déconnectez le dispositif d’ouverture à l’aide de la poignée de dégagement manuel. • N’utilisez PAS le transmetteur ni le dispositif de fermeture de porte. • Référez-vous aux manuels du propriétaire de la porte et de l’ouvre- porte avant de tenter toute réparation. ! Changing the Battery: 1. Remove vispr clip. 2. Remove small phillips head backing screw. 3. Pry case open with small coin or screwdriver. 4. Remove circuit board. 5. Replace battery with CR2032 coin cell. PROGRAMMING ASSISTANCE: If the opener does not activate after the steps shown, repeat steps or contact Customer Care by website chat (www.geniecompany.com) or by phone at: 1-800-354-3643 for programming assistance. You may also scan this QR code for additional information and links. For Patent Information: www.geniecompany.com/patent, ©2020, The Genie Company Residential Style Transmitters Commercial Style Transmitters STEP 1: PLACE OLDER STYLE RESIDENTIAL OPENER OR EXTERNAL RECEIVER INTO PROGRAMMING MODE Place opener into programming mode: 1. Press LEARN CODE button until RED LED begins to blink then release. 2. Press desired remote control button 3 times or until door operates. STEP 1: PLACE COMMERCIAL OPENER INTO PROGRAMMING MODE Adding a Single (OPEN/CLOSE/STOP) Transmitter 1. If operator is in RUN mode, press CAL/RUN key to enter calibration mode. 2. Press SCROLL (up or down) until display reads “LEARN NEW XMTR? ” Fig.1 • This question along with the instruction “HIT SET FOR YES” will continuously pan across the display window. (Pressing SCROLL or CAL/RUN will cancel the operation.) 3. Press SET/CLEAR . • Display will read “PUSH XMTR BUTTON TWO TIMES TO LEARN XMTR.” 4. Press OPEN Transmitter button two times. • The display will read “XMTR ___LEARNED.” Where it assigns a random number to the transmitter. That transmitter is entered and ready to operate the door. (Label the transmitter with this number.) 5. Press SCROLL (…

Text truncated - open the document above for the full version.

Attestation Statements

Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, Illinois 60515 Attn: Director of Certification FCC ID: B8Q1BTX, B8Q2BTX, B8Q3BTX, B8Q4BTX, B8QOCSTX Authority to Act as Agent FCC On our behalf, I appoint Rick King, of Elite Electronic Engineering, Inc. at 1516 Centre Circle, Downers Grove, Illinois 60515 to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Elite Electronic Engineering, Inc., still resides with The Genie Company, P.O. Box 67 Mt. Hope, OH 44660. Dated this 28 th Day of April 2020 Agency agreement expiration date: July 22, 2020 By: Mike Whitley Signature Printed Name Title: Sr. RF Engineer On behalf of : The Genie Company a Division of Overhead Door Corporation Telephone: 214-593-0042 Genie Company P. O. Box 67 Mt. Hope, OH 44660 Phone: 800-827-3667 (DOOR) Fax: 330-763-8042 www.geniecompany.com

Cover Letter(s)

Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, Illinois 60515-1082 FCC ID: B8Q1BTX, B8Q2BTX, B8Q3BTX, B8Q4BTX, B8QTX Product Name: 315390T4 Transmitter Model: G1BT-P, G2BT-P, G3BT-P, G4BT-P, GOCS-P, G1BT-R, G2BT-R, G3BT-R, G4BT-R, O1BT-P, O2BT-P, O3BT-P, O4BT-P, OOCS-P Request for Confidentiality P ursuant to Sections 0.457 and 0.459 of the commissions’ rules, we hereby request that the following documents be held confidential: •Electrical Schematics, Layout Drawings, and Bills of Materials •Theory of Operation Documentation / Technical Description •PCB Assembly and Block Diagram These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 24th Day of March 2020 By: Mike Whitey Signature Printed Title: Sr. RF Engineer On behalf of : The Genie Company a Division of Overhead Door Corporation Telephone: 830-660-0800 Genie Company P. O. Box 67 Mt. Hope, OH 44660 Phone: 800-827-3667 (DOOR) Fax: 330-763-8042 www.geniecompany.com

External Photos

3,2, and single Button Remote

ID Label/Location Info

NOTES: (UNLESS OTHERWISE SPECIFIED) D C B A AB C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THIRD ANGLE PROJECTION ENG F.20.041B-(FORM REV A) B 41428 PLOTTED: - MT. HOPE, OHIO RSM LABEL,FCC/IC,RCR XMTR, SEE NOTE #1 CHECKED MILLIMETERS FINISH UNLESS OTHERWISE SPECIFIED ALL DIMS ARE IN > Ø13 = +.20 / -.08 & MUST MEET APPLICABLE IN-PROCESS INSPECTION APPROVALS STANDARDS. DISCLOSED TO ANYONE WITHOUT PRIOR WRITTEN CONSENT OF OVERHEAD DOOR CORPORATION. DISCLOSURE OF ANY DRAWING OR INFORMATION IS INTENDED .X = ±.25.XX = ±.12.XXX = ±.06 TOLERANCES: DRAWN CORPORATION. MATERIAL SCALE 6:1 WRITTEN CONSENT OF OVERHEAD DOOR FOR ANY PURPOSE WITHOUT SPECIFIC LICENSE OR AUTHORIZATION TO USE IT NOT TO AND SHALL NOT OPERATE AS A ALL GEOMETRY GOVERNED BY 3D CAD DATABASE: DESCRIPTION DATE DRAWING NUMBER SEE NOTE #2 ANGULAR = ±1 3/13/2020 HOLES: PER ASME Y14.5M DO NOT SCALE SHEET 1 OF 1 INTERPRET DIMS & TOLS DOOR CORPORATION 41428 APPROVED SIZE A SUBSIDIARY OF OVERHEAD THE DRAWINGS AND ALL OTHER INFORMATION CONTAINED HEREIN ARE THE CONFIDENTIAL PROPRIETARY PROPERTY OF OVERHEAD DOOR CORPORATION, INCLUDING ITS AFFILIATED SUBSIDIARIES AND AFFILIATES. THIS DRAWING INFORMATION, IN WHOLE OR IN PART, MAY NOT BE COPIED IN ANY MANNER OR DIMS AND SPECIFICATIONS CIRCLED WITH SYMBOL ' ⊂⊃ ' ARE CRITICAL TO QUALITY DESIGN FEATURES < Ø6.5 = +.10 / -.08 Ø6.5-Ø13 = +.15 / -.08 MODEL NUMBER (SEE TABLE)FCC ID DATA (SEE TABLE)COMPANY NAME (SEE TABLE) INDUSTRY CANADADATA (SEE TABLE) WHITE BACKGROUND ORANGE BACKGROUND 25.40 3.76 9.53 R0.76 MODEL NUMBER (SEE TABLE) COMPANY NAME (SEE TABLE) FCC ID DATA (SEE TABLE) INDUSTRY CANADADATA (SEE TABLE) REVISIONS GCO REV DESCRIPTION DATE APPROVAL - 01 PRELIMINARY 03/20/2020 RSM - 02 ADDED SPECIFIC FCC ID AND IC DATA BY MODEL NUMBER TO CHART. 05/20/2020 RSM - 03 REVISED FCC ID AND INDUSTRY CANADA CHART DATA. 06/17/2020 RSM 41428P OOCS-P B8QOCSTX 2133A-OCSTX OVERHEAD DOOR CORPOR ATION 41428N O4BT-P B8Q4BTX 2133A-4BTX OVERHEAD DOOR CORPORAT ION 41428M O3BT-P B8Q3BTX 2133A-3BTX OVERHEAD DOOR CORPORAT ION 41428L O2BT-P B8Q2BTX 2133A-2BTX OVERHEAD DOOR CORPORAT ION 41428K O1BT-P B8Q1BTX 2133A-1BTX OVERHEAD DOOR CORPORAT ION 41428J GOCS-P B8QOCSTX 2133A-OCSTX THE GENIE COMPANY 41428H G4BT-P B8Q4BTX 2133A-4BTX THE GENIE COMPANY 41428G G3BT-P B8Q3BTX 2133A-3BTX THE GENIE COMPANY 41428F G2BT-P B8Q2BTX 2133A-2BTX THE GENIE COMPANY 41428E G1BT-P B8Q1BTX 2133A-1BTX THE GENIE COMPANY 41428D G4BT-R B8Q4BTX 2133A-4BTX THE GENIE COMPANY 41428C G3BT-R B8Q3BTX 2133A-3BTX THE GENIE COMPANY 41428B G2BT-R B8Q2BTX 2133A-2BTX THE GENIE COMPANY 41428A G1BT-R B8Q1BTX 2133A-1BTX THE GENIE COMPANY PART NUMBER MODEL NUMBER FCC ID DATA INDUSTRY CANADA DATA COMPANY NAME BLACK GRAPHICS AND TYPE ON 2 MIL MYLAR WITH PRESSUR E 1. SENSITIVE PERMANENT ADHESIVE FOR USE ON ABS PLASTIC , 1 MIL CLEAR MYLAR OVERLAY.CLEAN, COLOR PER ANSI Z535.1. 2.

Internal Photos

4 Button Remote, G4BT-P One PCB with5 different variantsDepending on switches 1 -4

Test Report

Engineering Test Report No. 2001550-01 Measurement of RF Emissions from a Model No. G4BT-R Four Button Remote Transmitter For Genie Company One Door Drive Mount Hope, OH 60523 P.O. Number 934030 Date Tested April 20 & 21, 2020 Test Personnel Tylar Jozefczyk Test Specification FCC "Code of Federal Regulations” Title 47 Part15, Subpart C Industry Canada RSS-GEN Industry Canada RSS-210 Test Report By: Tylar Jozefczyk EMC Engineer Requested By: Mike Whitley Genie Company Approved By: Raymond J. Klouda Registered Professional Engineer of Illinois - 44894 Engineering Test Report No. 2001550-01 TABLE OF CONTENTS PARAGRAPH DESCRIPTION OF CONTENTS PAGE NO. THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF ELITE ELECTRONIC ENGINEERING INCORPORATED. Page 2 of 40 1. Introduction ................................................................................................................................................... 5 1.1. Scope of Tests ..................................................................................................................................... 5 1.2. Purpose ............................................................................................................................................... 5 1.3. Deviations, Additions and Exclusions .................................................................................................. 5 1.4. EMC Laboratory Identification ............................................................................................................. 5 1.5. Laboratory Conditions.......................................................................................................................... 5 2. Applicable Documents .................................................................................................................................. 5 3. EUT Setup and Operation ............................................................................................................................ 5 3.1. General Description ............................................................................................................................. 5 3.1.1. Power Input ................................................................................................................................. 6 3.1.2. Grounding ................................................................................................................................... 6 3.2. Software ............................................................................................................................................... 6 3.3. Operational Mode ................................................................................................................................ 6 3.4. EUT Modifications ................................................................................................................................ 6 4. Test Facility and Test Instrumentation ......................................................................................................... 6 4.1. Shielded Enclosure .............................................................................................................................. 6 4.2. Test Instrumentation ............................................................................................................................ 6 4.3. Calibration Traceability ........................................................................................................................ 7 4.4. Measurement Uncertainty ................................................................................................................... 7 5. Test Procedures ........................................................................................................................................... 7 5.1. Powerline Conducted Emissions ......................................................................................................... 7 5.1.1. Requirements .............................................................................................................................. 7 5.2. Periodic Operation Measurements ...................................................................................................... 7 5.2.1. Requirements .............................................................................................................................. 7 5.2.2. Procedures .................................................................................................................................. 7 5.2.3. Results ........................................................................................................................................ 7 5.3. Duty Cycle Factor Measurements ....................................................................................................... 7 5.3.1. Procedures .................................................................................................................................. 7 5.3.2. Results ........................................................................................................................................ 8 5.4. Radiated Measurements ..................................................................................................................... 8 5.4.1. Requirements .............................................................................................................................. 8 5.4.2. Procedures .................................................................................................................................. 9 5.4.3. Results ........................................................................................................................................ 9 5.5. Occupied Bandwidth Measurements ................................................................................................... 9 5.5.1. Requirement......................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Engineering Test Report No. 2001550-01 Page 15 of 40 Figure 3 Test Setup for Radiated Emissions, 30MHz to 1GHz – Horizontal Polarization Test Setup for Radiated Emissions, 30MHz to 1GHz – Vertical Polarization Engineering Test Report No. 2001550-01 Page 16 of 40 Figure 4 Test Setup for Radiated Emissions, 1 to 4GHz – Horizontal Polarization Test Setup for Radiated Emissions, 1 to 4GHz – Vertical Polarization

Contact Information

Applicant

Mike Whitley(RF Engineer)
[email protected]830-660-0800Fax: 330-763-8011

Test Firm

Elite Electronic Engineering Inc.Kevin Halpin
[email protected]630-495-9770Fax: 630-495-9785

Technical Specifications

#Rule PartsFrequency RangePower Output
215.231390 MHz - 390 MHz-
Confidentiality
Long Term

Other Applications from The Genie Company a Division of Overhead Door Corporation

Door COntrol Module - FCC ID B8QALDCM2 - The Genie Company a Division of Overhead Door Corporation
B8QALDCM2

Door COntrol Module

Jun 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
B8QALDPS2

Door Position Sensor

May 29, 2026

Equipment Class

DTS - Digital Transmission System
Universal 2 Button Transmitter - FCC ID B8QU2 - The Genie Company a Division of Overhead Door Corporation
B8QU2

Universal 2 Button Transmitter

Jul 11, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Universal Wireless Wall Console - FCC ID B8QUWWC - The Genie Company a Division of Overhead Door Corporation
B8QUWWC

Universal Wireless Wall Console

Mar 22, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Universal Keypad Transmitter - FCC ID B8Q-UKEP - The Genie Company a Division of Overhead Door Corporation
B8Q-UKEP

Universal Keypad Transmitter

Mar 12, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter