Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Collateral Standards for the Philips Lifeline Cordless Phone Communicator IMPORTANT SAFETY INSTRUCTIONS When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. 3. Do not use the telephone to report a gas leak in the vicinity of the leak. SAVE THESE INSTRUCTIONS Federal Communications Commission (FCC): Specific Absorption Rate (SAR): Caution - To maintain the compliance with the FCC’s RF exposure guideline, place the base unit and voice extension unit at least 20 cm from nearby persons. For body worn operation, this handset has been tested and meets the FCC RF exposure guidelines. Use of accessories may not ensure compliance with FCC RF exposure guidelines. 47 CFR 15: Privacy of communications may not be ensured when using this phone. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. 47 CFR 68: This equipment is hearing aid compatible. Alarm Dialers: WHEN PROGRAMMING EMERGENCY NUMBERS AND(OR) MAKING TEST CALLS TO EMERGENCY NUMBERS: 1. Remain on the line and briefly explain to the dispatcher the reason for the call. 2. Perform such activities in the off-peak hours, such as early morning or late evenings. Caution - To ensure proper operation, this equipment must be installed according to the enclosed installation instructions. To verify that the equipment is operating properly and can successfully report an alarm, this equipment must be tested immediately after installation, and periodically thereafter, according to the enclosed test instructions. 0940838 CORDLESS Supplement NOTICE.indd 18/30/12 4:28 PM Philips Lifeline 111 Lawrence Street Framingham, MA 01702-8156 Tel: 1-800-451-0525 www.lifelinesystems.com Philips Lifeline Canada 95 Barber Greene Road, Suite 105 Toronto, Ontario, Canada M3C 3E9 Tel: 1-800-387-8120 www.lifeline.ca P/N 0940838, Rev. 01 © 2012. All rights reserved. Signal range may vary due to environmental factors. IMPORTANTES MESURES DE SÉCURITÉ Certaines mesures de sécurité doivent être prises pendant l’utilisation de material téléphonique afin de réduire les risques d’incendie, de choc électrique et de blessures. En voice quelquesunes: 1. Ne pas utiliser l’appareil près de l’eau, p.ex., près d’une baignoire, d’un lavabo, d’un évier de cuisine, d’un bac à laver, dans un sous-sol humide ou près d’une piscine. 2. Éviter d’utiliser le telephone (sauf s’il s’agit d’un appareil sans fil) pendant un orage électrique. Ceci peut présenter un risque de choc électrique causé par la foudre. 3. Ne pas utiliser l’appareil téléphonique pour signaler une fuite de gaz s’il est situé près de la fuite. CONSERVER CES INSTRUCTIONS Industry Canada (IC): ICES-003: This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. CS-03: This product meets the applicable Industry Canada technical specifications. / Le présent matériel est conforme aux specifications techniques applicables d’Industrie Canada. The Ringer Equivalence Number (REN = 0.1) is an indication of the maximum number of devices allowed to be connected to a telephone interface. The termination of an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices not exceed five. / L’indice d’équivalence de la sonnerie (IES = 0.1) sert à indiquer le nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique. La terminaison d’une interface peut consister en une combinaison quelconque de dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas cinq. 0940838 CORDLESS Supplement NOTICE.indd 28/30/12 4:28 PM Philips Lifeline Cordless Phone Communicator User’s Manual 2 Important Phone Numbers List of My Responders and People to Notify: Responders are people whom Lifeline will call in case of an emergency. People to Notify are people who will be notified that you required help but who are not involved in coming to your assistance. Please see page 6 for more information. Do They Name Phone Number(s) Have a Key? Contents Welcome ........................................................................................1 Chapter 1: Lifeline Service Getting Started ...............................................................................................................................4 Lifeline Help Button .....................................................................................................................4 Responders and People to Notify.....................................…
Text truncated - open the document above for the full version.
Philips Lifeline 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com Philips Healthcare Date: July 20, 2009 To whom it may concern, Declarations FCC ID: BDZ1000 IC: 655C-1000 I, the undersigned, hereby declare that 1. The device does not use the provisions of 47CFR 15.323 (c) (6), random waiting mechanism is not used in this system. 2. The provisions of 47CFR 15.323 (c) (10) and 47CFR 15.323 (c) (11) are not used to extend the range of spectrum occupied over space or time for the purpose of denying fair access to spectrum to other devices. 3. Only the handset will act as the initiating device, which will initiate the establishment of the duplex connection. 4. The device complies with the provisions of 47CFR 15.319(f). The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude transmission of control and signaling information or use of repetitive codes used by certain digital technologies to complete frame or burst intervals. The following table explains the reaction of device in case of either absence of information to transmit or operational failure after a connection of its companion device is established. Circumstances Reaction of Base Unit Reaction of Handset Reaction of Voice Extension Unit 1 Switch-off companion device B A A 2 On Hook by companion device B A A 3 Switch-off device A C C 4 On Hook on device side B C C 5 Remove power from device A C C 6 Remove power from companion device B A A A – Connection is terminated and, transmission ceases. B – Connection is terminated but device transmits control or signaling information. C – Connection is terminated but companion device transmits control or signaling information. NA – Not applicable If you have questions or need further information, please contact the undersigned. Regards, Clyde Dottin Manager, Engineering Services
April 13, 2009 Philips Lifeline 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com Attention: Application Examiner Reviewing Engineer Re: Request for Confidentiality Philips Healthcare Applicant: Lifeline Systems Inc. FCC ID: BDZ1000 To whom it may concern, Permanent Confidentiality Request is hereby submitted by Lifeline Systems Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description • Internal Photos Rationale for request for confidentiality: Lifeline Systems Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Regards, Clyde Dottin Manager, Engineering Services Philips Lifeline 111 Lawrence Street Framingham, MA 01702-8156 Phone: 508.988.1313 Fax: 240.536.3263 [email protected]
From:MIKE STIMA To:Yuriy Litvinov Intertek Subject:Re: UTAM Affidavit for Philips Date:Monday, September 17, 2012 7:09:46 AM Yuriy, Phillips is an active and valid current member of UTAM. Mike From: Yuriy Litvinov Intertek <[email protected]> To: "[email protected]" <[email protected]> Cc: "[email protected]" <[email protected]> Sent: Fri, September 14, 2012 2:03:33 PM Subject: UTAM Affidavit for Philips Mike, Please help to verify attached Affidavit from Philips per FCC Section 15.307. We have an application for certification for DECT phone. Regards, Yuriy Litvinov EMC/TCB Business Manager Phone: +1 651 286 5187 (direct) Intertek 7250 Hudson Blvd., Suite 100 Oakdale, MN 55128-9000 +1 (651) 492 5640 (mobile) +1 (651) 730-1282 (fax) Email: [email protected] www.intertek.com Valued Quality. Delivered. CONFIDENTIALITY NOTICE This email may contain confidential or privileged information, if you are not the intended recipient, or the person responsible for delivering the message to the intended recipient then please notify us by return email immediately. Should you have received this email in error then you should not copy this for any purpose nor disclose its contents to any other person. http://www.intertek.com
Philips Home Monitoring PHILIPS From; Carlos 0. Acosta Senior Quality & Regulatory Manager Date Friday, September 28, 2012 Addendum to the Declaration of RF Exposure Compliance for exemption from Routine Evaluation Limits, report completed by lntertek Note that the EUT is a base station device that is used in a Mobile Configuration. The maximum measured output power was 19.2 dBm (83 mW) and the antenna gain is stated by the manufacturer to be 1 dBi. Therefore, the EUT generates 20.2 dBm (105mW) EIRP peak, and with a duty cycle of —4%, the average EIRP is 4.2 mW and the minimum safe distance where the power density equals the General Occupation RF exposure limit of 1 mW/cm2 is 0.35 cm. Sincerely: Carlos 0. Acosta Senior Quality & Regulatory Affairs Manager Philips Home Monitoring/Lifeline System Inc. Philips Home Monitoring 111 Lawrence Street Framingham, MA 01702 www.philips.com
- The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Lifeline Systems Inc. Application For 47 CFR Part 15 Certification RSS-213 Issue 2 Equipment Certification Unlicensed Personal Communication Service Devices/ 2 GHz License-exempt Personal Communications Service Devices This report supersedes previous report with report number(s) HK09031025-1 dated June 23, 2009 FCC ID: BDZ1000 Model: DT1000 IC: 655C-1000 Model: DT1000 Test Report Number: HK09031025-1(R1) Issue Date: September 25, 2012 MN/cl INTERTEK TESTING SERVICES Test Report Number: HK09031025-1(R1) Page 1 of 70 FCC ID: BDZ1000 IC: 655C-1000 MEASUREMENT/TECHNICAL REPORT Lifeline Systems Inc. - Model: DT1000 FCC ID: BDZ1000 This report concerns (check one:) Original Grant X Class II Change Equipment Type : PUB - Part 15 Unlicensed PCS Base Station PUE - Part 15 Unlicensed PCS portable Tx held to ear Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until : __________________ Date Company Name agrees to notify the Commission by: Date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart D for Unlicensed Personal Communication Service Device - the new 47 CFR [10-01-10 Edition] Provision. Report prepared by: Nip Ming Fung, Melvin Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Phone : 852-2173-8538 Fax: 852-2741-1693 INTERTEK TESTING SERVICES Test Report Number: HK09031025-1(R1) Page 2 of 70 FCC ID: BDZ1000 IC: 655C-1000 Table of Contents 1.0 Summary of Test Results........................................................................................ 5 2.0 General Description................................................................................................. 8 2.1 Product Description ................................................................................................. 8 2.2 Technical Description .............................................................................................. 8 2.3 Test Methodology.................................................................................................... 9 2.4 Test Facility............................................................................................................. 9 3.0 System Test Configuration.................................................................................... 11 3.1 Justification ........................................................................................................... 11 3.2 Conducted Emission Test Configuration ................................................................ 12 3.3 Conducted Monitoring and Operational Test Configuration.................................... 12 3.4 EUT Exercising Software....................................................................................... 12 3.5 Details of EUT and Description of Peripherals....................................................... 13 3.6 Measurement Uncertainty ..................................................................................... 14 3.7 Equipment Modification ......................................................................................... 14 4.0 Measurement Results............................................................................................ 16 4.1 Antenna Requirement........................................................................................... 16 4.2 Digital Modulation Techniques............................................................................... 16 4.3 Emission Bandwidth.............................................................................................. 17 4.4 Directional Gain of the Antenna ............................................................................. 18 4.5 Peak Transmit Power ............................................................................................ 19 4.6 Power Spectral Density ......................................................................................... 20 4.7 Automatic Discontinuation of Transmission............................................................ 21 4.8 Unwanted Emission Inside the Sub-Band .............................................................. 22 4.9 Emissions Outside the Sub-Band .......................................................................... 24 4.9.1 Radiated Emissions Configuration Photographs ................................................. 25 4.9.2 Radiated Emissions Data ................................................................................... 25 4.9.3 Field Strength Calculation................................................................................... 35 4.9.4 Average Factor Calculation and Transmitter ON Ti…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15D | 1.92 GHz - 1.93 GHz | 77.00 mW |

Wireless Communicator
Equipment Class
PCB - PCS Licensed Transmitter
Mobile Help Button (MHB) for a Personal Emergency System (PERS)
Equipment Class
PCT - PCS Licensed Transmitter worn on body
Calgary communicator unit with ISM, GSM, WCDMA
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Personal Help Button/Auto-Alert Help Button
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
AutoAlert Help Button
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter