Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jan 26, 2020
Application Purpose
Original Equipment
Date of Application
Jan 26, 2020
Equipment Note
Wireless Communicator
Frequency Range
704.00000000 - 711.00000000
Company
Lifeline Systems Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Includes: GoSafe Mobile Systems and HomeSafe Systems with 7200C and 7000L Communicators Instructions for use Medical Alert Service Agency Submission File 2 Questions? Call 1-800-635-6156 Contents Philips Lifeline Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Welcome to Philips Lifeline Setting up your Lifeline Service Responders and People to Notify Calling for help inside your home Signal Range Battery information Equipment service Contact Philips Lifeline or your representative HomeSafe System and GoSafe Mobile System Communicators – General Information . . . . . . . . . . . . . . . . .15 Safety information regarding the Communicator Cleaning Backup battery Landline Communicator (7000L) . . . . . . . . . . . . . . . . . . . . . .18 Description Safety information Wireless Communicator (7200C) . . . . . . . . . . . . . . . . . . . . . . 22 Description Safety information HomeSafe System and GoSafe Mobile System Help Buttons – General Information . . . . . . . . . . . . . . . . . . .26 C ompatible Communicators Setting up a replacement Help Button Cleaning Agency Submission File 3 Questions? Call 1-800-635-6156 HomeSafe Personal Help Buttons (7000PHB or 7000PHW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Using the wristband Adjusting the neck cord Battery Recommended usage HomeSafe AutoAlert Button (7000AHB) . . . . . . . . . . . . . . . 36 B attery Recommended usage GoSafe Mobile Button (7000MHB/7100MHB) . . . . . . . . . . 43 C harging the battery Sleep mode Recommended usage Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 C ommunicator Alarms GoSafe Mobile Button Alarms Alarm Descriptions / Summary Tables Safety and Regulatory Compliance . . . . . . . . . . . . . . . . . . . . 73 I EC regulations System classification Radio specifications FCC Notice to Users Radio interference Industry Canada Notice to Users Class B digital device notice Compliance Intended Use Contraindications Compatibility Risks and Benefits Training Safety Open source software Maintenance Technical Specifications Agency Submission File 4 Questions? Call 1-800-635-6156 Philips Lifeline Service Welcome to Philips Lifeline Thank you for choosing the Philips Lifeline Medical Alert Service. Please refer to the Quick Setup Guide provided for instructions on setting up your equipment. These Instructions for Use will provide you with information about your equipment and the Lifeline Medical Alert Service. Please read this manual and the Quick Setup Guide carefully, and note the Warnings and Cautions. If you have questions, call Lifeline at any time using the number at the bottom of the page. Please save this manual in case you need to refer to it later. Please pay special attention to all the instructions provided in the Warning and Caution sections. A Warning alerts you to a potential serious outcome, adverse event or safety hazard. Failure to observe a warning may result in death or serious injury to the user or patient. A Caution alerts you to where special care is necessary for the safe and effective use of the product. Failure to observe a caution may result in minor or moderate personal injury or damage to the product or other property, and possibly in a remote risk of more serious injury, and/or cause environmental pollution. Agency Submission File 5 Questions? Call 1-800-635-6156 These Instructions for Use and the Quick Setup Guide describe the most extensive configuration of the product, with the maximum number of options and accessories. Not every function described may be available on your product. This manual covers the following: Landline Communicator (7000L) A Communicator that connects to Lifeline using your home’s existing landline telephone service. Compatible landline telephone service is required for proper operation. Wireless Communicator (7200C) A Communicator that connects to Lifeline using the AT&T wireless network. Wireless service is provided as part of your Lifeline Service; no additional wireless equipment is needed. Agency Submission File 6 Questions? Call 1-800-635-6156 HomeSafe Personal Help Button (7000PHB and 7000PHW) HomeSafe AutoAlert Button (7000AHB) GoSafe Mobile Buttons (7000MHB/ 7100MHB) Works within the range of your Communicator    Works outside * your home and outside the range of your Communicator  Can be worn around neck as a pendant    Can be worn on a wristband  Can detect falls ** in your home   Can detect falls ** outside * your home  Has a built-in speaker and microphone  * When access to the AT&T wireless network is available. ** The HomeSafe AutoAlert Button and GoSafe Mobile Buttons provide an extra layer of protection by placing a Help Call if a fall is detected and you can’t push the Button. Not all falls can be detected. If you need help, press your Help Button. Agency Submission File 7 Questions? Call 1-800-635-6156 Setting up your Lifeline Service Before you can use your system, your Communicator must be properly set up, and the signal range of your Help Button must be determined. Please see the Quick Setup Guide for instructions on how to set up your system and test the signal range of your Help Button. If you have any questions, please contact Philips Lifeline or your representative. Responders and People to Notify What is a “Responder”? If you should need emergency assistance and activate your Pendant, a responder is someone you want Philips Lifeline to contact to physically go to you and help you. As a Lifeline subscriber, you should have designated people who have agreed to be “Responders.” These are people whom Lifeline should call in an emergency, when appropriate. Responders may also be called upon to help address issues with your system. Examples include: neighbors, friends, relatives, your current nursing aide, etc. Choosing a Responder It is best to choose a Responder who: • Has a key to your home or knows where one is located (perhaps in a key loc…

Text truncated - open the document above for the full version.

Cover Letter(s)

SGS North America Inc. Consumer and Retail 620 Old Peachtree Road Suite 100 Suwanee GA 30024 t (770) 570-1800 f (770) 277-1240 www.sgs.com Member of the SGS Group (SGS SA) Attn: Director of Certification Test data referencing regarding application for FCC ID: BDZ7200C A certified transmitter module from u-blox with FCC ID: XPY1DIQN3NN is integrated into the 7200C Wireless Communicator for which certification is being sought in this application. The equipment class for this device is PCB (PCS Licensed Transmitter), the applicable FCC rule parts are 24E and 27, and the bands used are LTE bands 2, 4 and 12. Under authorization from u-blox (see accompanying authorization letter), test report MDE_UBLOX_1712_FCCb_rev1 on the LARA-R203 LTE module is included in this submission package. Also included is a test report containing radiated spurious emissions spot check data on the end product covering all supported frequency bands. SGS has reviewed the report and affirms that the testing performed as reported in the above referenced test report shows that the product complies with the following standard: ANSI C63.26:2015 Sincerely, Martin Taylor Agent for Lifeline Systems Inc SGS North America Title: RF/EMC Engineer Date: 20 January 2020

Cover Letter(s)

Philips Lifeline 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com Philips Healthcare Date: July 31, 2019 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: BDZ7200C To whom it may concern: We, the undersigned, hereby authorize SGS North America, Inc. to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Lifeline Systems Inc. This authorization is valid until further written notice from the applicant. Name (Printed): Bill Bekdash Title: Quality and Regulatory Engineer Signature: On behalf of Company: Lifeline Systems Inc. Telephone: 508.988.1044

Cover Letter(s)

SGS North America Inc. Consumer and Retail 620 Old Peachtree Road Suite 100 Suwanee GA 30024 t (770) 570-1800 f (770) 277-1240 www.sgs.com Member of the SGS Group (SGS SA) Attn: Director of Certification Confidentiality Request regarding application for FCC ID: BDZ7200C LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby requests confidential treatment of the documents listed below, associated with the certification application referenced above. Schematics Block Diagrams Operational Description Parts List / BOM The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within 180 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User Manual Sincerely, Martin Taylor Agent for Lifeline Systems Inc SGS North America Title: RF/EMC Engineer Date: 08 August 2019

External Photos

EXTERNAL PHOTOGRAPHS Lifeline Systems Inc 7200C Wireless Communicator FCC ID: BDZ7200C IC ID: 655C-7200C 2 3 4 5 6 7 WWW.SGS.COM © SGS Group Management SA – 2016 – All rights reserved - SGS is a registered trademark of SGS Group Management SA

External Photos

INTERNAL PHOTOGRAPHS Lifeline Systems Inc 7200C Wireless Communicator FCC ID: BDZ7200C IC ID: 655C-7200C 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 WWW.SGS.COM © SGS Group Management SA – 2016 – All rights reserved - SGS is a registered trademark of SGS Group Management SA

ID Label/Location Info

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interfer ence, and (2) this device must accept any in terfer ence received, including interfer ence that may cause undesired operation. FCC ID: BDZ7200C IC: 655C-7200C CAN ICES-3 (B) / NMB-3 (B) 12VDC; 1.25A IP21 300003982841 Rev. A 5002925

ID Label/Location Info

9051234567 300003472821 Model: 7200C (01) 00884838096776 (11) YYMMDD (21) 9051234567 YYYY-MM-DD 300003982941 Rev. A (96) 300003472821 Rev.XX

ID Label/Location Info

Philips Lifeline Systems Inc. Communicator 7200C labels location - US device

Internal Photos

INTERNAL PHOTOGRAPHS Lifeline Systems Inc 7200C Wireless Communicator FCC ID: BDZ7200C IC ID: 655C-7200C 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 WWW.SGS.COM © SGS Group Management SA – 2016 – All rights reserved - SGS is a registered trademark of SGS Group Management SA

RF Exposure Info

Test Report Number: 4494805EMC05 Rev: 0 Lifeline Systems Inc / Medical Alert System Page: 1 of 5 Remarks: This report details the results of the testing carried out on one sample, the results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and- Conditions.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. RF Exposure Report Project Number: 4494805 Quotation Number: 02212019TH-1.3 Report Number: 4494805EMC05 Revision Level: 0 Client: Lifeline Systems Inc Equipment Under Test: Medical Alert System Model Name: Wireless Communicator Model Number: 7200C FCC ID: BDZ7200C Applicable Standards: 47 C.F.R. §§ 2.1091 and 2.1093; FCC KDB 447498 FCC KDB 447498 D01 General RF Exposure Guidance v06 Report issued on: 12 September 2019 Test Result: Compliant Test Report Number: 4494805EMC05 Rev: 0 Lifeline Systems Inc / Medical Alert System Page: 2 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) TABLE OF CONTENTS 1 GENERAL INFORMATION ............................................................................................................................................. 3 1.1 CLIENT INFORMATION ................................................................................................................................................... 3 1.1 TEST LABORATORY ....................................................................................................................................................... 3 1.2 GENERAL INFORMATION OF EUT .................................................................................................................................. 3 1.3 OPERATING MODES AND CONDITIONS .......................................................................................................................... 3 2 RF EXPOSURE ................................................................................................................................................................... 4 2.1 TEST RESULT ................................................................................................................................................................. 4 2.2 TEST METHOD ............................................................................................................................................................... 4 2.3 SINGLE TRANSMISSION RF EXPOSURE LEVELS (MW/CM 2 ) ............................................................................................ 4 2.4 SIMULTANEOUS TRANSMISSIONS ................................................................................................................................... 4 3 REVISION HISTORY ........................................................................................................................................................ 5 Test Report Number: 4494805EMC05 Rev: 0 Lifeline Systems Inc / Medical Alert System Page: 3 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) 1 General Information 1.1 Client Information Name: Lifeline Systems Inc Address: 111 Lawrence Street City, State, Zip, Country: Framingham, MA 01702 USA 1.1 Test Laboratory Name: SGS North America, Inc. Address: 620 Old Peachtree Road NW, Suite 100 City, State, Zip, Country: Suwanee, GA 30024, USA Accrediting Body: A2LA Type of lab: Testing Laboratory Certificate Number: 3212.01 1.2 General Information of EUT Equipment Under Test: Medical Alert System Model Name: Wireless Communicator Model Number: 7200C Serial Number: 9040234871 9040234870 FCC ID: BDZ7200C Tx Frequency Ranges: 1850 – 1910 MHz (LTE Band 2) 1710 – 1755 MHz (LTE Band 4) 699 – 716 MHz (LTE Band 12) 917 – 921 MHz (ISM Band) Antenna Type: Internal PCB Antennas: 2 (selectable) for ISM, 2 (diversity) for LTE Antenna Gains: (all maximum peak gains) ISM Antenna 1: 2.1 dBi ISM Antenna 2: 3.0 dBi LTE Main Antenna: 3.1 dBi (Bands 2&4), 1.6 dBi (Band 12) LTE Diversity Antenna: 3.1 dBi (Bands 2&4), -0.2 dBi (Band 12) Sample Received Date: 08 July 2019 Dates of testing: 10 July 2019 (900MHz ISM Band) 1.3 Operating Modes and Conditions The EUT had an internal battery pack installed and was connected to the AC Mains using the supplied AC/DC wall adapter. The EUT was running test mode software which allowed it to be commanded to turn on a continuous transmit signal at maximum power at different channels in the 900 MHz ISM Band. The EUT only used channels with center frequencies ranging from 917 to 921 MHz in the ISM Band. Note: Certified radio module grant data (FCC ID: XPY1DIQN3NN) was used for the LTE Bands. Test Report Number: 4494805EMC05 Rev: 0 Lifeline Systems Inc / Medical Alert System Page: 4 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) 2 RF Exposure 2.1 Test Result Test Description Product Specific Standard Test Res…

Text truncated - open the document above for the full version.

Test Report

Test Report Number: 4494805EMC03 Rev: 2 Lifeline Systems Inc / Medical Alert System Page: 1 of 20 Remarks: This report details the results of the testing carried out on one sample, the results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and- Conditions.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. EMC Test Report Project Number: 4494805 Quotation Number: 02212019TH-1.3 Report Number: 4494805EMC03 Revision Level: 2 Client: Lifeline Systems Inc Equipment Under Test: Medical Alert System Model Name: Wireless Communicator Model Number: 7200C FCC ID: BDZ7200C IC: 655C-7200C FCC Rule Parts: Part 2, Part 24(E), Part 27 Industry Canada: RSS-GEN, Issue 5, Amendment 1, March 2019 RSS-130, Issue 2, February 2019 RSS-133, Issue 6, Amendment 1, January 2018 RSS-139, Issue 3, July 2015 Applicable Standards: ANSI C63.26: 2015 Report issued on: 20 January 2020 Test Result: Compliant Tested by: Martin Taylor, Project Engineer Reviewed by: David Schramm, Operations Manager Test Report Number: 4494805EMC03 Rev: 2 Lifeline Systems Inc / Medical Alert System Page: 2 of 20 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) Table of Contents 1 SUMMARY OF TEST RESULTS ..................................................................................................................................... 3 1.1 MODIFICATIONS REQUIRED TO COMPLIANCE ................................................................................................................ 3 2 GENERAL INFORMATION ............................................................................................................................................. 4 2.1 CLIENT INFORMATION ................................................................................................................................................... 4 2.2 TEST LABORATORY ....................................................................................................................................................... 4 2.3 GENERAL INFORMATION OF EUT .................................................................................................................................. 4 2.4 OPERATING MODES AND CONDITIONS .......................................................................................................................... 4 2.5 EUT CONNECTION BLOCK DIAGRAM ............................................................................................................................ 5 2.6 SYSTEM CONFIGURATIONS ............................................................................................................................................ 5 2.7 CABLE LIST ................................................................................................................................................................... 5 3 RADIATED SPURIOUS EMISSIONS.............................................................................................................................. 6 3.1 TEST RESULT ................................................................................................................................................................. 6 3.2 TEST METHOD ............................................................................................................................................................... 6 3.3 TEST SITE ...................................................................................................................................................................... 6 3.4 TEST EQUIPMENT .......................................................................................................................................................... 7 3.5 TEST DATA .................................................................................................................................................................... 8 4 AC POWERLINE CONDUCTED EMISSIONS ............................................................................................................ 17 4.1 TEST RESULT ............................................................................................................................................................... 17 4.2 TEST METHOD ............................................................................................................................................................. 17 4.3 TEST SITE .................................................................................................................................................................... 17 4.4 TEST EQUIPMENT ........................................................................................................................................................ 17 4.5 TEST DATA .................................................................................................................................................................. 18 5 REVISION HISTORY ......................................…

Text truncated - open the document above for the full version.

Test Report

Final Report on LARA-R203 LTE Single Mode FCC ID: XPY1DIQN3NN IC : 8595A-1DIQN3NN MDE_UBLOX_1712_FCCb_rev1 Report Reference: July 29, 2017 Date: Test Laboratory: 7layers GmbH Borsigstraße 11 40880 Ratingen Germany Note: The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts without the written approval of the test laboratory. 7layers GmbH Registergericht registered in: Borsigstraße 11 Geschäftsführer / Düsseldorf, HRB 75554 40880 Ratingen, Germany Managing Directors: USt-IdNr VAT No.: T +49 (0) 2102 749 0 Frank Spiller DE203159652 F +49 (0) 2102 749 350 Bernhard Retka TAX No. 147/5869/0385 www.7layers.com Alexandre Norré-Oudard A Bureau Veritas Group Company according to FCC Part 24, Subpart E and Part 27, Subpart C Reference: MDE_UBLOX_1712_FCCb_rev1 1 Administrative Data 1.1 Project Data Andreas Tübel Project Responsible: 2017/07/29 Date Of Test Report: 2017/05/03 Date of first test: 2017/06/26 Date of last test: 1.2 Applicant Data Company Name: u-blox AG Zürcherstrasse 68, CH-8800 Thalwil Street: Switzerland Country: Contact Person: Mr. Giulio Comar Certification Manager Function: Cellular Product Certification Department: +41 44 722 7462 Phone: +41 44 722 7447 Fax: [email protected] E-Mail: 1.3 Test Laboratory Data The following list shows all places and laboratories involved for test result generation: 7 layers DE Company Name : 7layers GmbH Street : Borsigstrasse 11 City : 40880 Ratingen Country : Germany Contact Person : Mr. Michael Albert Phone : +49 2102 749 201 Fax : +49 2102 749 444 E Mail : [email protected] Laboratory Details Accreditation InfoLab IDIdentificationResponsible DAkkS-Registration no. D-PL-12140-01-00 ISEDC OATS registration number 3699A-1 FCC accreditation registration number 929146 Radiated Emissions Lab 1Mr. Marco Kullik Mr. Jens Dörwald DAkkS-Registration no. D-PL-12140-01-00 ISEDC OATS registration number 3699A-1 FCC accreditation registration number 929146 Radio Lab Lab 2Mr. Dobrin Dobrinov Mr. Daniel Gall Page 2 of 99 Reference: MDE_UBLOX_1712_FCCb_rev1 1.4 Signature of the Testing Responsible Jens Doerwald responsible for tests performed in: Lab 1, Lab 2 1.5 Signature of the Accreditation Responsible Accreditation scope responsible person responsible for Lab 1, Lab 2 2 Test Object Data 2.1 General OUT Description The following section lists all OUTs (Object's Under Test) involved during testing. OUT: LARA-R203 Type / Model / Family:LARA-R203 LTE Single Mode FCC ID: XPY1DIQN3NN IC : 8595A-1DIQN3NN Product Category: Module Manufacturer: see applicant data Company Name: Contact Person: see applicant data ValueParameter name Parameter List: 120V / 60Hz (V) AC Power Supply 12 (V) DC Power Supply eFDD12 (1.4 MHz) -> CH 23173 -> 715.3 MHz, eFDD4 (1.4 MHz) -> CH 20393 -> 1754.3 MHz, eFDD2 (1.4 MHz) -> CH 19193 -> 1909.3 MHz highest channel eFDD12 (1.4 MHz) -> CH 23017 -> 699.7 MHz, eFDD4 (1.4 MHz) -> CH19957 -> 1710.7 MHz, eFDD2 (1.4 MHz) -> CH 18607 -> 1850.7 MHz lowest channel eFDD12 (1.4 MHz) -> CH 23095 -> 707.5 MHz, eFDD4 (1.4 MHz) -> CH 20175 -> 1732.5 MHz, eFDD2 (1.4 MHz) -> CH 18900 -> 1880 MHz mid channel Page 3 of 99 Reference: MDE_UBLOX_1712_FCCb_rev1 2.2 Detailed Description of OUT Samples Sample : hc02 OUT Identifier LARA-R203 Sample Description Protocol Sample Serial No. 356935080013649 HW Status 2730A1 SW Status 30.33 Low VoltageLow Temp. 3.3 V-20 °C High Temp.High Voltage 4.4 V+55 °C Normal Temp.Nominal Voltage 3.8 V+23 °C Sample : hd02 OUT Identifier LARA-R203 Sample Description FCC Sample Serial No. 356935080013409 HW Status 2730A1 SW Status 30.33 Low VoltageLow Temp. 3.3 V-20 °C High Temp.High Voltage 4.4 V+55 °C Normal Temp.Nominal Voltage 3.8 V+23 °C Sample : ia04 OUT Identifier LARA-R203 Sample Description RF Sample Serial No. 356935080016147 HW Status 2730A2 SW Status 30.34 Low VoltageLow Temp. 3.3 V-20 °C High Temp.High Voltage 4.4 V+55 °C Normal Temp.Nominal Voltage 3.8 V+23 °C Page 4 of 99 Reference: MDE_UBLOX_1712_FCCb_rev1 2.3 OUT Features Features for OUT: LARA-R203 Allowed ValuesDesignationDescriptionSupported Value(s) Features for scope: FCC_v2 Eant removable antenna supplied and type tested with the radio equipment, designed as an indispensable part of the equipment eFDD2 eFDD4 eFDD12 TantC temporary antenna connector, which may be only built-in for testing, designed as an example part of the equipment 2.4 Auxiliary Equipment AE No.Serial No.SW StatusHW StatusDescriptionType Designation AE AE01EVB-WL3 NO_EVK_CS_19 1A00 Evaluation test board AE AE02UUX324-1215G05-0122268AC/DC converter 2.5 Setups used for Testing For each setup a relation is given to determine if and which samples and auxiliary equipment is used. The left side list all OUT samples and the right side lists all auxiliary equipment for the given setup. Sample No.Sample DescriptionAE No.AE Description Setup No. List of OUT samplesList of auxiliary equipment S01_HC02 (HC02) AE AE01Evaluation test boardhc02Protocol Sample Sample: AE AE02AC/DC converter S01_HD02 (HD02) AE AE01Evaluation test boardhd02FCC Sample Sample: AE AE02AC/DC converter S01_IA04 (IA04) AE AE01Evaluation test boardia04RF Sample Sample: AE AE02AC/DC converter Page 5 of 99 Reference: MDE_UBLOX_1712_FCCb_rev1 3 Results 3.1 General Available at the test laboratory. The results of the inspection are described on the following pages, where 'Conformity' or 'Passed' means that the certification criteria were verified and that the tested device is conform to the applied standard. In cases where 'Declaration' is printed, the required documents are available in the manufacturers product documentation. In cases where 'not applicable' is printed, the test case requirements are not relevant to the specific equipment implementation. Documentation of tested devices: Interpretation of the test results: 1. All tests are performed under environmental conditions within the requirements of the specifications. Environmental conditions ar…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOS Lifeline Systems Inc 7200C Wireless Communicator FCC ID: BDZ7200C IC ID: 655C-7200C 2 RADIATED EMISSIONS 30-1000 MHZ FRONT VIEW 3 RADIATED EMISSIONS 30-1000 MHZ REAR VIEW 4 RADIATED EMISSIONS 1-18 GHZ FRONT VIEW 5 RADIATED EMISSIONS 1-18 GHZ REAR VIEW 6 RADIATED EMISSIONS 18-20 GHZ FRONT VIEW 7 RADIATED EMISSIONS 18-20 GHZ REAR VIEW 8 CONDUCTED EMISSIONS 0.15-30 MHZ FRONTVIEW 9 CONDUCTED EMISSIONS 0.15-30 MHZ SIDEVIEW WWW.SGS.COM WWW.SGSGROUP.US.COM © SGS Group Management SA – 2018 – All rights reserved - SGS is a registered trademark of SGS Group Management SA

Contact Information

Applicant

Roberto Ballester(Principal Design Quality Engineer)
[email protected]8005433546Fax: 5089883072

Technical Contact

SGS North AmericaMartin Taylor
[email protected]770-570-1800

620 Old Peachtree Road NW · Suwanee, Georgia · United States

Non-Technical Contact

SGS North AmericaMartin Taylor
[email protected]770-570-1800

Test Firm

SGS North America, Inc.David Schramm
[email protected]973-461-7914Fax: 973 575 7175

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1227704 MHz - 711 MHz131.00 mW9M06W7D0.1 ppm
Confidentiality
Long Term
Grant Notes
Power listed is conducted. Co-location is permitted with the use of FCC multi-transmitter product procedures or as shown in this filing. End users and installers must be provided with transmitter operation conditions for satisfying RF exposure compliance. The antenna gain, including cable loss, must not exceed the values shown in the filing to meet RF Exposure, ERP and EIRP limitations.

Other Applications from Lifeline Systems Inc

Mobile Help Button (MHB) for a Personal Emergency System (PERS) - FCC ID BDZ7000MHB - Lifeline Systems Inc
BDZ7000MHB

Mobile Help Button (MHB) for a Personal Emergency System (PERS)

Sep 19, 2013

Equipment Class

PCT - PCS Licensed Transmitter worn on body
Calgary communicator unit with ISM, GSM, WCDMA - FCC ID BDZ7000C - Lifeline Systems Inc
BDZ7000C

Calgary communicator unit with ISM, GSM, WCDMA

Sep 12, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Personal Help Button/Auto-Alert Help Button - FCC ID BDZFD100SL - Lifeline Systems Inc
BDZFD100SL

Personal Help Button/Auto-Alert Help Button

Nov 01, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Philips Lifeline Cordless Phone Communicator - FCC ID BDZ1000 - Lifeline Systems Inc
BDZ1000

Philips Lifeline Cordless Phone Communicator

Sep 27, 2012

Equipment Class

PUE - Part 15 Unlicensed PCS portable Tx held to ear
AutoAlert Help Button - FCC ID BDZFD100 - Lifeline Systems Inc
BDZFD100

AutoAlert Help Button

May 11, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter