FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lifeline Systems Inc/
  3. BDZ7000MHB

BDZ7000MHBMobile Help Button (MHB) for a Personal Emergency System (PERS)

Lifeline Systems Inc
Mobile Help Button (MHB) for a Personal Emergency System (PERS) - FCC ID BDZ7000MHB - Lifeline Systems Inc
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Sep 19, 2013
Application Purpose
Original Equipment
Date of Application
Jul 17, 2013
Equipment Note
Mobile Help Button (MHB) for a Personal Emergency System (PERS)
Frequency Range
826.40000000 - 846.60000000
Company
Lifeline Systems Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Philips Lifeline 111 Lawrence Street Framingham, MA 01702 Exhibit 8: Compliance Statements for Philips’ 7000MHB Compliance statements: FCC Rules Compliance Statement (Part 15.19) The enclosed hardware device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by Philips Healthcare, Home Monitoring, Lifeline Systems Inc. could void the user’s authority to operate the equipment. Manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Compliance Statement (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Philips Lifeline 111 Lawrence Street Framingham, MA 01702 Industry Canada (IC) regulatory information This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Class B digital device notice This Class B digital apparatus complies with Canadian ICES-003, RSS-Gen and RSS-210. Cet appareil numérique de la classe B est conforme à la norme NMB-003, CNR-Gen et CNR-210 du Canada. SAR Compliance The user must maintain a separation distance of 10 mm when operating the device in the held to face configuration.

Users Manual

Philips Lifeline Medical Alert Service Includes: GoSafe Mobile System and HomeSafe System Instructions for use FPO DRAFT 2 Contents Philips Lifeline Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x Welcome to Philips Lifeline Setting up your Lifeline Service Responders and People to Notify Calling for help inside your home Setting up a new Help Button Signal Range Battery information Equipment service Important notes HomeSafe System and GoSafe Mobile System Communicators – General Information . . . . . . . . . . . . . . .xx S afety information regarding the Home Communicator Cleaning Backup battery Landline Communicator (7000L) . . . . . . . . . . . . . . . . . . . .xx Description Safety information Wireless Communicator (7000C) . . . . . . . . . . . . . . . . . . . .xx Description Safety information HomeSafe System and GoSafe Mobile System Help Buttons – General Information . . . . . . . . . . . . . . . . .xx Warnings and Cautions Cleaning DRAFT 3 HomeSafe Personal Help Buttons (7000PHB or 7000PHW) . . . . . . . . . . . . . . . . . . . . . . . . . . .xx Description Using the Wrist Strap Recommended usage HomeSafe AutoAlert Button (7000AHB) . . . . . . . . . . . . .xx Cautions Features Compatible Home Communicators What to expect if you fall Battery Recommended usage GoSafe Mobile Button (7000MHB) . . . . . . . . . . . . . . . . . . .xx Cautions Features Calling for help away from home What to expect if you fall Charging the battery Sleep mode Recommended usage Mobile Button warranty Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . .xx FCC Regulations Explanation of symbols Requirements for the United States Additional Warnings and Cautions DRAFT 4 Landline Communicator (7000L) A Home Communicator that connects to Lifeline using your home’s existing landline telephone service. Landline telephone service is required. Wireless Communicator (7000C) A Home Communicator that connects to Lifeline using a cellular network. Cellular service is provided as part of your Lifeline Service and is dependant upon cellular network coverage. Help call in progress. Please wait. Hello, Mrs. Smith. Welcome to Philips Lifeline. Philips Lifeline Service Welcome to Philips Lifeline Thank you for choosing the Philips Lifeline Medical Alert Service. These Instructions for Use will provide you with information about your equipment and the Lifeline Medical Alert Service. Please read the manual carefully, and if you have questions, call Lifeline at any time. Please save this manual in case you need to refer to it later. This manual covers the following: DRAFT 5 Help call in progress. Please wait. Hello, Mrs. Smith. Welcome to Philips Lifeline. Help call in progress. Please wait. Hello, Mrs. Smith. Welcome to Philips Lifeline. Help call in progress. Please wait. Hello, Mrs. Smith. Welcome to Philips Lifeline. HomeSafe Personal Help Button (7000PHB and 7000PHW) HomeSafe AutoAlert Button (7000AHB) GoSafe Mobile Button (7000MHB) Works inside your home    Works outside * your home  Can be worn as a pendant    Can be worn on a wristband  Detects falls ** in your home   Detects falls ** outside * your home  Has a built-in speaker and microphone  * When access to a cellular network is available. ** Not all falls can be detected. If you fall and need help, press your Help Button. Setting up your Lifeline Service Before you can use your system, your Home Communicator must be properly set up, and the coverage range of your Help Button must be determined for your Lifeline Service. Please see the Quick Setup Guide for instructions on how to set up your system and test the coverage range of your Help Button. If you have any questions, please contact Lifeline. DRAFT 6 Responders and People to Notify What is a “Responder”? As a Lifeline subscriber, you should have designated people who have agreed to be “Responders.” These are people whom Lifeline should call in an emergency, when appropriate. Examples include: neighbors, friends, relatives, your current nursing aide, etc. Choosing a Responder It is best to choose a Responder who: • Has a key to your home or knows where one is located (perhaps in a key lockbox) • Could come to help you at different times of the day or night • Lives or works within 10 minutes of where you live • Has a phone, preferably a cell phone • Ideally has a driver’s license and access to a vehicle If you are using the GoSafe System, choose a Responder who can also: • Drive to your location, whether you are at home or away from home, and provide help if needed Information Lifeline needs about Responders Please ensure that Lifeline has the following information about each person acting as a Responder: • Name • Phone numbers – home, work and cell phone. • Whether or not the Responder has a key to your home. DRAFT 7 It’s very important that you keep your Responders and their contact information up to date. Remember to contact Lifeline if one of your Responders is no longer able to assist you or if they get a new telephone number. Please contact Lifeline for any questions about selecting or being a Responder. Who are “People to Notify”? If you call for help, Lifeline will contact the “People to Notify” to let them know that you received assistance. “People to Notify” will not be contacted to help you, unless they are also on your list of “Responders.” Calling for help inside your home 1. Press the Help Button that you wear or the gray Help Button on the top of your Home Communicator. You can press either button, but you do not need to press both. The Home Communicator will beep and dial the Lifeline Response Center. Note: The Response Center is available 24 hours a day, 365 days a year. A trained Personal Response Associate is always available to assist you. Help call in progress. Please wait. Hello, Mrs. Smith. Welcome to Philips Lifeline. DRAFT 8 2. The Home Communicator calls the Response Center. When it dials the Response Center, the Home Communicat…

Text truncated - open the document above for the full version.

Attestation Statements

PHILIPS Philips Healthcare August 13, 2013 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Subject: 7000MHB 802.11 Receive Mode Only Attestation Letter Dear Sirs or Madams, We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingham, MA 01702, (508) 988-3002, hereby attest that our 7000MHB device operates in 802.11 receive mode only. Sincerely, C4 Kimberly Cook Senior Engineering Manager Philips Healthcare Home Monitoring 508-988-3002kimberly.cookphilips.com Philips Ufene PHILIPS 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com [i fel 1 11 e

Attestation Statements

PHILIPS Philips Healthcare August 13, 2013 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Subject: 7000MHB Attestation Letter Re: Manual Update Requested by FCC Dear Sirs or Madams, We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingham, MA 01702, (508) 988-3002, hereby attest that our 7000MHB device manual will be updated to add the following (highlighted yellow) as requested by the FCC: For best results, hold the Button up and away from your chest when you are speaking to Lifeline. Maintain a separation distance of 10 mm/ 0.394 in when operating the device in the held to face configuration, to meet the FCCRF Exposure safety requirements. Sincerely, Kimberly Cook Senior Engineering Manager Philips Healthcare Home Monitoring [email protected] Philips Lifeline PHILIPS PHI 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com [41 fel 1 1i e Ii

Attestation Statements

September 19, 2013 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Subject: BDZ7000MHB Voice Prompt Attestation Letter Dear Sirs and Madams, PHILIPS Philips Healthcare We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingham, MA 01702, (508) 988-3002, hereby attest that our voice prompt is activated for incoming and outgoing calls, and, for RF safety, we will change the 7000MHB’s voice prompt to: “For proper use, hold your help button up in front of you.” Sincerely, Senior Engineering Manager Philips Healthcare Home Monitoring [email protected] Philips Lifeline 111 Lawrence Street Framingham, MA 01702 PHILIPS Lifeline Kimberly Coo’ www.lifelinesys.com

Cover Letter(s)

PHILIPS Philips Heatthcare July 3, 2013 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingharn, MA 01702, (508)988-3002, hereby authorize TUVSUD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121, (858)942-5554 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on December 31, 2013. Sincerely, Carlos Acosta Senior Manager Quality and Regulatory Philips Healthcare Home Monitoring [email protected] Philips Utetne PHILIPS 111 Lawrence Street Framingham,MA 01702 www.lifelinesys.com [i fel 1 ri e

Cover Letter(s)

PHILIPS Philips Healthcare July 16, 2013 BABT FOB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Dear Sirs or Madams, We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingham, MA 01702, (508) 988-3002, hereby authorize Phil Dolling, TUV BABT Technical Certifier, to submit and sign the FCC application on behalf of Philips and to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on December 31, 2013. Sincerely, Kimberly Cook Senior Engineering Manager Philips Healthcare Home Monitoring 508-988-3002 [email protected] Philips Lifeline PHILIPS 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com I_41 fel 1 11 e

Cover Letter(s)

Philips Healthcare Philips Lifeline 111 Lawrence Street Framingham, MA 01702 www.lifelinesys.com July 10, 2013 To: BABT TCB Forsyth House Churchfield Road, Walton-on-Thames Surrey KT12 2TD Subject: Authorization to sign as the Grantee for Philips Lifeline. To Whom It May Concern This letter is to authorize the following to also represent Philips Lifeline as Grantee in all matters relating to the United States Federal Communications Commission:  Kim Cook (Sr. Manager, Engineering)  Carlos Acosta (Sr. Manager, Quality and Regulatory)  Doug Woodruff (Director, Quality and Regulatory) If there are any questions please feel free to contact. Yours truly, Clyde Dottin Manager, Configuration and Data Management Philips Healthcare, Home Healthcare Solutions, Home Monitoring 111 Lawrence Street Framingham, MA 01702-8156 Phone: 508.988.1313 Fax: 240.536.3263 [email protected]

Cover Letter(s)

PHILIPS Philips Healthcare August 12, 2013 BABT FOB Forsyth House, Churchfield Road, Walton-on-Thames,Surrey, KT12 2TD Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Dear Sirs or Madams, We, Philips Healthcare, Home Monitoring, Lifeline Systems Inc., 111 Lawrence Street, Framingham, MA 01702, (508) 988-3002, hereby authorize Phil Dolling and Vina Kerai, of TUV, to submit and sign the FCC application on behalf of Philips and to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on December 31, 2013. Sincerely, Kimberly Cook Senior Engineering Manager Philips Healthcare Home Monitoring 508-988-3002 kim [email protected] Philips Lifeline PHLPS I I I Lawrence Street Framingham, MA 01702 www.lifelinesys.com [41 fel 1 ri e

Cover Letter(s)

PHILIPS Philips Healthcare July 3, 2013 BABT TCB Forsyth House, Churchileld Road, Walton-on-Thames, Surrey, KT12 2TD Confidentiality Request FCC ID: BDZ7000MHB Pursuant to Sections 0.457(d)(l)(ii) and 0.459 of the Commission’s Rules, Philips Healthcare, Home Monitoring, Lifeline Systems Inc. hereby requests permanent confidential treatment of information accompanying this application as outlined below: Design Drawings Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation Philips Healthcare, Home Monitoring, Lifeline Systems Inc. also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180 days): Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(l)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. You s-si,ncerely, 3 _J_ C i 3 Carlos Acosta Senior Manager Quality and Regulatory Philips Healthcare Home Monitoring [email protected] Phiflps Ufeline PHILIPS 11 1 Lawrence Street Framingham,MA 01702 www.lifeflnesys.com [1i fe] i ii e

External Photos

EXTERNAL PHOTOS INSIDE – COVER OFF COVER ON – BACK SIDE FRONT SIDE BACK SIDE WITH LABELS

ID Label/Location Info

Philips Lifeline 111 Lawrence Street Framingham, MA 01702-8156 CAGE CODE NO. 0S0W2 ENGINEERING SPECIFICATION NO. 0750720 PHILIPS LIFELINE PROPRIETARY THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF PHILIPS LIFELINE AND, EXCEPT FOR THE RIGHTS EXPRESSLY GRANTED BY THE CONTRACT, THIS DOCUMENT SHALL BE HELD IN THE STRICTEST CONFIDENCE AND SHALL NOT BE REPRODUCED, USED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF PHILIPS LIFELINE. PROGRAM NAME: MERCIER SPECIFICATION TITLE: LABEL, BOTTOM HOUSING, MERCIER DATE PREPARED BY: S.SHIRAR 09/28/12 REVISIONS REV DESCRIPTION DATE APPROVAL REVDESCRIPTION DATE APPROVAL A Release to Engineering Control per ECO 9479 09/28/12 SS B Update per ECO 9896 03/25/13 PL 0750720 CAGE Code: 0S0W2 REV. B 2 of 3 Mercier (7000MHB) Rear Laser Etching 25.90mm 49.00mm 53.60mm 57.30mm 62.80mm 29.60mm 0 0750720 CAGE Code: 0S0W2 REV. B 3 of 3 Laser Etch Attributes: - Shot Frequency= 15000 - Scan Speed = 600 - Fill Parameters  Fill Type = Single Line  Fill Option = Bidirectional  Fill Angle = 45  Fill Space = 0.04 - Detail Parameters – see Table 1 below: ItemDescriptionLaser Power (%)PassesNotes 1Philips Lifeline Logo901min width 12.5 mm 2Serial Number (Last 4 Digits)901variable 3Refer to IFU Icon901ISO 7010‐M002 4Serial Number901variable 5FCC,IC code901USA and Canada Regulatory ID 6Product Barcode901variable 7Emmission Icon901IEC 60417‐5140 8Date of Manufacture901variable, YYYYMMDD 9Applied Part Icon901IEC 60417‐5333 10Model Number901variable Table 1 – Laser Etching Parameters General Notes: 1. Refer to 0750720_AW file for actual images, fonts, and all other details. 2. Placement dimensions +/- 0.50 mm unless otherwise specified.

Internal Photos

Internal photos of PCB Top side with Shield Top Side without shield Bottom side of Board

RF Exposure Info

802 N. Twin Oaks Valley Road, Suite 105 • San Marcos, CA 92069 • U.S.A. TEL (760) 471-2100 • FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Lifeline Systems Inc. Dates of Test: June 26 - 27, 2013 111 Lawrence Street Test Report Number: SAR.20130606 Framingham, MA 01702 Revision B This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2003, and OET Bulletin 65 Supp. C (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Certificate # 2387.01 FCC ID: BDZ7000MHB IC Certificate: 655C-7000MHB Model(s): 7000MHB Test Sample: Engineering Unit Same as Production S/N Number: 1030000092 Equipment Type: Wireless mPERS Classification: Portable Transmitter Next to Face and Body TX Frequency Range: 824 – 848 MHz; 1850 – 1910 MHz; 917 – 920 MHz Frequency Tolerance: ± 2.5 ppm Maximum RF Output: 850 MHz (GSM) – 32.7 dBm, 850 MHz (WCDMA) – 23.6 dBm, 1900 MHz (GSM) – 29.6 dBm, 1900 MHz (WCDMA) – 23.9 dBm, 900 MHz – <3.23 dBm Conducted Signal Modulation: WCDMA, GMSK, 8-PSK Antenna Type: PCB Application Type: Certification FCC Rule Parts: Part 2, 22, 24 KDB Test Methodology: KDB 447498 D01 v05 Max. Face SAR Value: 0.68 W/kg – 1 gram average – Reported Max. Body SAR Value: 1.46 W/kg – 1 gram average – Reported Max. Extremity SAR Value: 1.62 W/kg – 10 gram average – Reported Separation Distance (Face): 10 mm Separation Distance (Body): 8 mm Separation Distance (Extremity): 0 mm © 2013 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. FCC ID: BZD7000MHB Table of Contents 1. Introduction ........................................................................................................................ 3 SAR Definition [5] ................................................................................................................... 4 2. SAR Measurement Setup ................................................................................................... 5 Robotic System ...................................................................................................................... 5 System Hardware ................................................................................................................... 5 System Electronics ................................................................................................................. 6 Probe Measurement System .................................................................................................. 6 3. Probe and Dipole Calibration .............................................................................................11 4. Simulating Tissue Specifications .......................................................................................12 Head & Body Simulating Mixture Characterization ................................................................12 5. ANSI/IEEE C95.1 – 1992 RF Exposure Limits [2] ..............................................................13 Uncontrolled Environment .....................................................................................................13 Controlled Environment .........................................................................................................13 6. Measurement Uncertainty .................................................................................................14 7. System Validation..............................................................................................................15 Tissue Verification .................................................................................................................15 Test System Verification ........................................................................................................15 8. SAR Test Data Summary ..................................................................................................16 Procedures Used To Establish Test Signal ...........................................................................16 Device Test Condition ...........................................................................................................16 9. FCC 3G Measurement Procedures ...................................................................................18 9.1 Procedures Used to Establish RF Signal for SAR ......................................................18 9.2 SAR Measurement Conditions for WCDMA/HSDPA/HSUPA .....................................18 9.3 SAR Measurement Conditions for GSM.....................................................................19 SAR Data Summary – Face ..................................................................................................23 SAR Data Summary – Body ..................................................................................................24 SAR Data Summary – Extremity ...........................................................................................25 10. Test Equipment List .......................................................................................................27 11. Conclusion ....................................................................................................................28 12.…

Text truncated - open the document above for the full version.

Test Report

Report No.: EH/2010/A0041 FCC ID: XPYLISAU120 Issue Date: Nov. 12, 2010 Page: 1 of 95 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indem- nification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized altera- tion, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134, Wu Kung Road, Wuku Industrial Zone, Taipei County, Taiwan /北路134 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 22 SUBPART H, PART 24 SUBPART E OF Product Name: LISA-U120, LISA-U100 Brand Name: u-blox AG Model Name: LISA-U120, LISA-U100 Model Difference: Please refer to page 6 FCC ID: XPYLISAU120 Report No.: EH/2010/A0041 Issue Date: Nov. 12, 2010 FCC Rule Part: 2 , 22H & 24E Prepared for: u-blox AG Zurcherstrasse 68, 8800 Thalwil, Switzerland Prepared by SGS Taiwan Ltd. Electronics & Communication Laboratory No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei County, Taiwan. Note: This report shall not be reproduced except in full, without the written approval of SGS Taiwan Ltd. This document may be altered or revised by SGS Taiwan Ltd. personnel only, and shall be noted in the revision section of the document. Report No.: EH/2010/A0041 FCC ID: XPYLISAU120 Issue Date: Nov. 12, 2010 Page: 2 of 95 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indem- nification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized altera- tion, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134, Wu Kung Road, Wuku Industrial Zone, Taipei County, Taiwan /北路134 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group VERIFICATION OF COMPLIANCE Applicant: u-blox AG Zurcherstrasse 68, 8800 Thalwil, Switzerland Product Name: LISA-U120, LISA-U100 Brand Name: u-blox AG Model No.: LISA-U120, LISA-U100 Model Difference: Please refer to page 6 FCC ID: XPYLISAU120 File Number: EH/2010/A0041 Date of test: Oct. 29, 2010 ~ Nov. 09, 2010 Date of EUT Received: Oct. 29, 2010 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. Electronics & Communication Laboratory The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in TIA/EIA-603-C-2004 and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rule FCC PART 22 subpart H. The test results of this report relate only to the tested sample identified in this report. Test By: Date: Nov. 12, 2010 Jason Wu / Asst. Supervisor Prepared By: Date: Nov. 12, 2010 Tiffany Kao / Clerk Approved By: Date: Nov. 12, 2010 Arno Hsieh /Asst. Supervisor Report No.: EH/2010/A0041 FCC ID: XPYLISAU120 Issue Date: Nov. 12, 2010 Page: 3 of 95 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indem- nification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at th…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Roberto Ballester(Principal Design Quality Engineer)
[email protected]8005433546Fax: 5089883072

Test Firm

SGS Taiwan Ltd.Jason Lin
[email protected]886-2-2299-3279Fax: 886 2 2298 2248

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
622H826.4 MHz - 846.6 MHz632.00 mW4M05F9W2.5 ppm
Confidentiality
Long Term

Other Applications from Lifeline Systems Inc

Wireless Communicator - FCC ID BDZ7200C - Lifeline Systems Inc
BDZ7200C

Wireless Communicator

Jan 26, 2020

Equipment Class

PCB - PCS Licensed Transmitter
Calgary communicator unit with ISM, GSM, WCDMA - FCC ID BDZ7000C - Lifeline Systems Inc
BDZ7000C

Calgary communicator unit with ISM, GSM, WCDMA

Sep 12, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Personal Help Button/Auto-Alert Help Button - FCC ID BDZFD100SL - Lifeline Systems Inc
BDZFD100SL

Personal Help Button/Auto-Alert Help Button

Nov 01, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Philips Lifeline Cordless Phone Communicator - FCC ID BDZ1000 - Lifeline Systems Inc
BDZ1000

Philips Lifeline Cordless Phone Communicator

Sep 27, 2012

Equipment Class

PUE - Part 15 Unlicensed PCS portable Tx held to ear
AutoAlert Help Button - FCC ID BDZFD100 - Lifeline Systems Inc
BDZFD100

AutoAlert Help Button

May 11, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter