FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Tyco Safety Products Canada Ltd./
  3. F53119057

F53119057Wireless Security System

Tyco Safety Products Canada Ltd.
Wireless Security System - FCC ID F53119057 - Tyco Safety Products Canada Ltd.
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jul 26, 2011
Application Purpose
Original Equipment
Date of Application
Jul 25, 2011
Equipment Note
Wireless Security System
Frequency Range
433.92000000 - 433.92000000
Company
Tyco Safety Products Canada Ltd.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Self Contained Wireless Alarm System SCW9055/SCW9057 v1.0 User Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. DRAFT FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digit- al Security Controls could void your authority to use this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential in- stallation. This equipment generates, uses and can radiate radio frequency ener- gy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter- mined by turning the equipment off and on, the user is encouraged to try to cor- rect the interference by one or more of the following measures: • Re-orient the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult a dealer or experienced radio/television technician for help. The user may find the following booklet prepared by the FCC useful: "How to Identify and Resolve Radio/Television Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4. IMPORTANT INFORMATION This equipment complies with Part 68 of the FCC Rules and, if the product was approved July 23, 2001 or later, the requirements adopted by the ACTA. On the top side of this equipment is a label that contains, among other information, a product identifier. If requested, this number must be provided to the Telephone Company. Product Identifier:US:F53AL01B9057 USOC Jack:RJ-31X Telephone Connection Requirements A plug and jack used to connect this equipment to the premises wiring and tele- phone network must comply with the applicable FCC Part 68 rules and require- ments adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible mod- ular jack that is also compliant. See installation instructions for details. Ringer Equivalence Number (REN) The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local Telephone Company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US: AAAEQ##TXXXX. The digits represented by ## are the REN without a deci- mal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. REN = 0.1B Incidence of Harm If this equipment (SCW9055/SCW9057) causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the Telephone Company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. Changes in Telephone Company Equipment or Facilities The Telephone Company may make changes in its facilities, equipment, opera- tions or procedures that could affect the operation of the equipment. If this hap- pens the Telephone Company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. Equipment Maintenance Facility If trouble is experienced with this equipment (SCW9055/SCW9057) for repair or warranty information, contact the facility indicated below. If the equipment is causing harm to the telephone network, the Telephone Company may request that you disconnect the equipment until the problem is solved. This equipment is of a type that is not intended to be repaired by the end user. DSC c/o APL Logistics 757 Douglas Hill Rd., Lithia Springs, GA 30122 Additional Information Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. Alarm dialling equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialling equipment must be connected to a properly installed RJ-31X jack that is electrically in series with and ahead of all other equipment attached to the same telephone line. Proper installation is depicted in the figure below. If you have any questions concerning these instructions, you should consult your telephone company or a qualified installer about installing the RJ-31X jack and alarm dialling equipment for you. INDUSTRY CANADA STATEMENT NOTICE: This product meets the applicable Industry Canada technical spec- ifications. Le présent materiel est conforme aux specifications techniques applicables d’In- dustrie Canada. The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. L'indice d'équivalence de la sonnerie (IES) du présent matériel est de 0.1. The Ringer Equivalence Number is an indication of the maximum number of de- vices allowed to be connected to a telephone interface. The termination on an in- ter…

Text truncated - open the document above for the full version.

Cover Letter(s)

Digital Security Controls 3301 Langstaff Road Concord, Ontario Canada L4K 4L2 Tele: 905 760 3000 Toll Free: 888 888 7838 www.dsc.com June 28, 2011 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: F53119057 Product Name: SCW9057-433, SCW9055-433 Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential:  Schematics  Block diagram  Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 28th Day of June 20 11 By: Dan Nita Signature Printed Title: Approvals Manager On behalf of : Digital Security Controls Telephone: 905-760-3000, Ext. 2706

Cover Letter(s)

June 28, 2011 To Whom It May Concern: Respectfully yours, Dan Nita Approvals Manager

External Photos

EUT photos Front view Rear view Side view Side view

ID Label/Location Info

18008600R001 SCW9055-433 NA Listing Label (FCC/IC/UL/ULC/CP-01/CSFM) June 13, 2011 Top of the unit shows the label location (80% of actual size) Label shown 150% of actual size Colour: Pantone Process Black Material: CLEAR UL approved self-adhesive Mylar type material Lamination: Top lamination (e.g. 1F9, or equivalent) Adhesive: Permanent adhesive backed with protec- tive liner Cutting: Tolerance +/- 0.010” Dashed line indicates cutting - will not print NOTES: 1. All UL and ULC Labels shall be printed on UL approved material. The first time the label is ordered, the artwork must be sent to UL Label Center [email: [email protected], fax: (847)509-6201] for approval. 2. All UL and ULC Labels shall be printed by a UL Listed printing facility. The issue number (when applicable) shall be requested from the same center as above by the printing facility at the time of printing. NOTES: 1. All items must be RoHS compliant. 2. Markings on label must be PERMANENT. 3. Indelible Ink. 4. Conductive inks may not be used. Digital Security Controls 3301 Langstaff Road Concord, Ontario Canada L4K 4L2 Tele: 905 760 3000 Toll Free: 888 888 7838 Fax: 905-760-3020 DIGITAL SECURITY CONTROLS, TORONTO, CANADA MADE IN CANADA FABRIQUE AU CANADA 18008600R001 CONTROL UNIT (HOUSEHOLD) 7167-1273:XXX DSC, 95 Bridgeland Ave. Toronto, Ontario, Canada M6A 1Y7 Type of signaling: DACT No line security US: F53AL01B9057 FCC ID: F53119057 IC: 160A-9057 REN=0.1 This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class B est conforme a la norme NMB-003 du Canada. Model: SCW9055-433 RESIDENTIAL FIRE AND BURGLARY CONTROLLER HOUSEHOLD FIRE WARNING AND/OR BURGLAR ALARM SYSTEM FIRE ALARM AND SECURITY EQUIPMENT ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP-01-2010 89SL 74 mm 22 mm DIGITAL SECURITY CONTROLS, TORONTO, CANADA MADE IN CANADA FABRIQUE AU CANADA 18008600R001 CONTROL UNIT (HOUSEHOLD) 7167-1273:XXX DSC, 95 Bridgeland Ave. Toronto, Ontario, Canada M6A 1Y7 Type of signaling: DACT No line security US: F53AL01B9057 FCC ID: F53119057 IC: 160A-9057 REN=0.1 This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class B est conforme a la norme NMB-003 du Canada. Model: SCW9055-433 RESIDENTIAL FIRE AND BURGLARY CONTROLLER HOUSEHOLD FIRE WARNING AND/OR BURGLAR ALARM SYSTEM FIRE ALARM AND SECURITY EQUIPMENT ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP-01-2010 89SL Label P/N 18008600 18008601R001 SCW9057-433 NA Listing Label (FCC/IC/UL/ULC/CP-01/CSFM) June 13, 2011 Top of the unit shows the label location (80% of actual size) Label shown 150% of actual size Colour: Pantone Process Black Material: CLEAR UL approved self-adhesive Mylar type material Lamination: Top lamination (e.g. 1F9, or equivalent) Adhesive: Permanent adhesive backed with protec- tive liner Cutting: Tolerance +/- 0.010” Dashed line indicates cutting - will not print NOTES: 1. All UL and ULC Labels shall be printed on UL approved material. The first time the label is ordered, the artwork must be sent to UL Label Center [email: [email protected], fax: (847)509-6201] for approval. 2. All UL and ULC Labels shall be printed by a UL Listed printing facility. The issue number (when applicable) shall be requested from the same center as above by the printing facility at the time of printing. NOTES: 1. All items must be RoHS compliant. 2. Markings on label must be PERMANENT. 3. Indelible Ink. 4. Conductive inks may not be used. Digital Security Controls 3301 Langstaff Road Concord, Ontario Canada L4K 4L2 Tele: 905 760 3000 Toll Free: 888 888 7838 Fax: 905-760-3020 DIGITAL SECURITY CONTROLS, TORONTO, CANADA MADE IN CANADA FABRIQUE AU CANADA 18008601R001 CONTROL UNIT (HOUSEHOLD) 7167-1273:XXX DSC, 95 Bridgeland Ave. Toronto, Ontario, Canada M6A 1Y7 Type of signaling: DACT No line security US: F53AL01B9057 FCC ID: F53119057 IC: 160A-9057 REN=0.1 This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class B est conforme a la norme NMB-003 du Canada. Model: SCW9057-433 RESIDENTIAL FIRE AND BURGLARY CONTROLLER HOUSEHOLD FIRE WARNING AND/OR BURGLAR ALARM SYSTEM FIRE ALARM AND SECURITY EQUIPMENT ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP-01-2010 89SL 74 mm 22 mm DIGITAL SECURITY CONTROLS, TORONTO, CANADA MADE IN CANADA FABRIQUE AU CANADA 18008601R001 CONTROL UNIT (HOUSEHOLD) 7167-1273:XXX DSC, 95 Bridgeland Ave. Toronto, Ontario, Canada M6A 1Y7 Type of signaling: DACT No line security US: F53AL01B9057 FCC ID: F53119057 IC: 160A-9057 REN=0.1 This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class B est conforme a la norme NMB-003 du Canada. Model: SCW9057-433 RESIDENTIAL FIRE AND BURGLARY CONTROLLER HOUSEHOLD FIRE WARNING AND/OR BURGLAR ALARM SYSTEM FIRE ALARM AND SECURITY EQUIPMENT ALSO CLASSIFI…

Text truncated - open the document above for the full version.

Internal Photos

EUT photos SCW9057-433 UA558 Rev 03 inside view 1 (top cover with keymat) SCW9057-433 UA558 Rev 03 PCB bottom view SCW9057-433 UA568 Rev 03 PCB top view

Test Report

15.231.doc - Date: June, 2011 www.nemko.com Compliance test report 179120-3TRFWL Date of issue July 22, 2011 Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators §15.231- Periodic operation in the band 40.66–40.70 MHz and above 70 MHz Applicant Digital Security Controls, a Division of Tyco Safety Products Canada Ltd. Product Self-Contained Wireless Alarm System Product category Alarm System Model SCW9057-433 FCC ID F53119057 Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation SCC Accredited LAB LAB Accrédité CCN Report reference ID: 179120-3TRFWL Page 2 of 28 Test location Nemko Canada Inc. 303 River Road Ottawa, ON, K1V 1H2 CANADA Telephone +1 613 737 9680 Facsimile +1 613 737 9691 Toll free +1 800 563 6336 Website www.nemko.com Tested by David Duchesne, Senior Wireless/EMC Specialist Reviewed by July 22, 2011 Andrey Adelberg, Senior Wireless/EMC Specialist Date: Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Canada’s ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: 179120-3TRFWL Page 3 of 28 Table of contents Section 1: Report summary ......................................................................................................................................................... 4 1.1 Test specifications ....................................................................................................................................................... 4 1.2 Statement of compliance ............................................................................................................................................. 4 1.3 Exclusions ................................................................................................................................................................... 4 1.4 Test report revision history .......................................................................................................................................... 4 Section 2: Summary of test results ............................................................................................................................................. 5 2.1 FCC Part 15 Subpart C – Intentional radiators, test results ......................................................................................... 5 Section 3: Equipment under test (EUT) details .......................................................................................................................... 6 3.1 Applicant ...................................................................................................................................................................... 6 3.2 Sample information ...................................................................................................................................................... 6 3.3 EUT information ........................................................................................................................................................... 6 3.4 EUT technical information ............................................................................................................................................ 6 3.5 EUT exercise details .................................................................................................................................................... 6 3.6 EUT setup diagram ...................................................................................................................................................... 7 Section 4: Engineering considerations ....................................................................................................................................... 8 4.1 Modifications incorporated in the EUT ......................................................................................................................... 8 4.2 Technical judgment ...................................................................................................................................................... 8 4.3 Deviations from laboratory tests procedures ............................................................................................................... 8 Section 5: Test conditions ........................................................................................................................................................... 9 5.1 Atmospheric conditions ................................................................................................................................................ 9 5.2 Power supply range ..................................................................................................................................................... 9 Section 6: Measurement uncertainty ........................................................................................................................................ 10 6.1 Uncertainty of measurement ..................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Setup Photos Photo 1: Radiated emissions setup Photo 2: Radiated emissions setup Setup Photos Photo 3: AC Conducted emissions setup

Contact Information

Applicant

Dan Nita(Approvals Manager)
[email protected]1-647-480-0430Fax: 1-647-480-0531

Test Firm

Nemko Canada Inc. (Ottawa)Charles Neal
[email protected]613-737-9680Fax: 613-737-9691

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Tyco Safety Products Canada Ltd.

IQ Lock-PGP, IQ Lock Touch-PGP - FCC ID F53252RFLOCK - Tyco Safety Products Canada Ltd.
F53252RFLOCK

IQ Lock-PGP, IQ Lock Touch-PGP

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
PowerG wireless transceiver module - FCC ID F5325PGPDC9 - Tyco Safety Products Canada Ltd.
F5325PGPDC9

PowerG wireless transceiver module

Apr 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Dual Technology Motion Sensor - FCC ID F5325LC203424 - Tyco Safety Products Canada Ltd.
F5325LC203424

Dual Technology Motion Sensor

Dec 17, 2025

Equipment Class

FDS - Part 15 Field Disturbance Sensor
F5324PGPIO9

Wireless Input / Output (I/O) w/wo contact

Dec 04, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Motion detector with integrated camera - FCC ID F5323PGP9934P - Tyco Safety Products Canada Ltd.
F5323PGP9934P

Wireless Motion detector with integrated camera

Jan 16, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter