FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Tyco Safety Products Canada Ltd./
  3. F5324PGPIO9

F5324PGPIO9Wireless Input / Output (I/O) w/wo contact

Tyco Safety Products Canada Ltd.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 04, 2024
Application Purpose
Original Equipment
Date of Application
Dec 02, 2024
Equipment Note
Wireless Input / Output (I/O) w/wo contact
Frequency Range
912.75000000 - 919.10600000
Company
Tyco Safety Products Canada Ltd.
Country
Canada

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Certification Application Attestation Statements < Tyco Safety Products Canada Ltd.> <3301 Langstaff Road > < Concord L4K 4L2> < Ontario, Canada > Subject: FCC ID: < F5324PGPIO9> To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) [Tyco Safety Products Canada Ltd.] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Tyco Safety Products Canada Ltd.] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” identified on the Covered List as an entity producing “covered” equipment. Date: November 18, 2024 City: Concord Name (2) : Dan Nita Function: Approvals Manager Telephone number: 1-647-480-0430 Email address: [email protected] Signature: Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02- 2023 1 st version RvM 02 1 15-02- 2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : __-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : __-02-2023

Cover Letter(s)

November 18, 2024 Telefication B.V. Attn: Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Application for certification for a Tyco Safety Products Canada Ltd., FCC ID: F5324PGPIO9 Dear Gentlemen, Please find attached our application for certification for a Wireless Input / Output (I/O) w/wo contact, FCC ID: F5324PGPIO9, prepared in accordance with FCC Rules, parts 2 and 15, section 15.247(FHSS). The product testing and this application for certification were performed by Hermon Laboratories, which is recognized and accredited by FCC, Test Firm Registration Number is 927748, Designation Number is IL1001. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. We hope this application satisfies your requirements. Please send an invoice to Hermon Labs. Dan Nita, Approvals Manager Tyco Safety Products Canada Ltd.

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Declaration of Authorization We Name: Tyco Safety Products Canada Ltd. Address: 3301 Langstaff Road . City: Concord L4K 4L2. Country:  Ontario, Canada . Declare that: Name Representative of agent: Peysahov Sheynin Svetlana............. (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel is authorized to apply for Certification of the following product(s): Product description:  Wireless Input / Output (I/O) w/wo contact . Type designation:  PGP-IO9, PGP-IO9MC . Trademark:  Johnson Controls . Validity/ expiry date November 14, 2025 on our behalf. Date:  November 14, 2024.. City:  Concord .. Name:  Dan Nita (2) Function: ......... Approvals Manager ............. Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 02 1 02-01-2023 History sheet added AG Issued/modified by : Axel Gase Function : Quality Manager Revision : 02 Date : 02-01-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 02-01-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 02-01-2023

Cover Letter(s)

FCC, Request for non-disclosure Date: 23-06-2023 RF_501, Issue 11 Page 1 of 2 Company Name: Tyco Safety Products Canada Ltd. Address: 3301 Langstaff Road City: Concord L4K 4L2 Country: Ontario, Conada To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: F5324PGPIO9 Reference number: 54530 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: in order to avoid exposed of the technology to the competitors Date: Noovember 18, 2024 Name and signature of applicant: Dan Nita Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! FCC, Request for non-disclosure Date: 23-06-2023 RF_501, Issue 11 Page 2 of 2 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 23-06-2023 RF_501, Issue 11 Page 3 of 2 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG 11 1 & 2 23-06-2023 Corrected date and page# WJJ Issued/modified by : Willem Jan Jong Function : Team Lead Revision : 11 Date : 23-06-2023 Verified by : Axel Gase Function : Manager Quality Assurance Date : 23-06-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 23-06-2023

ID Label/Location Info

ECM Title: JCI LABEL DRAWING FCC ID/IC,UL Product Name: LABEL PGP-IO9 PRODUCT Date Name Document No: 4018098 29.01.2024 Albert F. Created Document Rev: 00 27.10.2024 Albert F. Updated Sheet 1 of 1 27.10.2024 Shay A. Approved MATERIAL: Polyester S-308785 SIZE: 38*10 mm two labels in one row. NOTES:

RF Exposure Info

FCC ID: F5324PGPIO9 Page 1 of 1 Environmental evaluation and exposure limit according to FCC CFR 47part 1, §1.1307, §1.1310 The Wireless Transceiver is classified as a mobile device. The Wireless Transceiver includes transmitter operating according to FCC part 15 subpart C section 15.247 (FHSS) The FCC limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 912.75/1500 = 0.61 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4 r 2 P T is the transmitted power, which is equal to the peak transmitter output power 13.78 dBm plus maximum antenna gain 7 dBi, the maximum equivalent isotropically radiated power EIRP is P T = 13.78 dBm + 7 dBi = 20.78 dBm = 119.67 mW. The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: Compliance with FCC limit: 119.67 mW / 4 (20 cm) 2 = 0.024 mW/cm 2 << 0.61 mW/cm 2 General public cannot be exposed to dangerous RF level.

Test Report

Hermon Laboratories Ltd. 66 HaTachana str., P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 55 Report ID: VISRAD_FCC.54530.docx Date of Issue: 4-Nov-24 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 15 subpart C §15.247 (FHSS), subpart B, RSS-247 Issue 3:2023, RSS-Gen Issue 5, ICES-003 Issue 7:2020 FOR: Tyco Safety Products Canada Ltd. Wireless Input / Output (I/O) w/wo contact Models: PGP-IO9, PGP-IO9MC FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC.54530.docx Date of Issue: 4-Nov-24 Page 2 of 55 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in the EUT ............................................................................................................................................ 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-247 requirements .................................................. 7 7.1 20 dB bandwidth ........................................................................................................................................................... 7 7.2 Carrier frequency separation ....................................................................................................................................... 10 7.3 Number of hopping frequencies .................................................................................................................................. 12 7.4 Average time of occupancy ......................................................................................................................................... 14 7.5 Peak output power ...................................................................................................................................................... 17 7.6 Field strength of spurious emissions ........................................................................................................................... 23 7.7 Band edge radiated emissions .................................................................................................................................... 37 7.8 Antenna requirements ................................................................................................................................................. 42 8 Unintentional emissions .............................................................................................................................................. 43 8.1 Radiated emission measurements .............................................................................................................................. 43 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 47 10 APPENDIX B Test equipment correction factors ......................................................................................................... 48 11 APPENDIX C Measurement uncertainties .................................................................................................................. 51 12 APPENDIX D Test laboratory description ................................................................................................................... 52 13 APPENDIX E Specification references........................................................................................................................ 53 14 APPENDIX F Abbreviations and acronyms ................................................................................................................. 54 15 APPENDIX G Manufacturer’s declaration ................................................................................................................... 55 Report ID: VISRAD_FCC.54530.docx Date of Issue: 4-Nov-24 Page 3 of 55 1 Applicant information Client name: Tyco Safety Products Canada Ltd. Address: 3301 Langstaff Road, Concord, Ontario L4K 4L2, Canada Telephone: 1-647-480-0430 Fax: 1-647-480-0531 E-mail: [email protected] Contact name: Mr.…

Text truncated - open the document above for the full version.

Test Setup Photos

Tyco Safety Products Canada Ltd. FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 Page 1 of 5 SETUP PHOTOGRAPHS This document contains 5 photographs Tyco Safety Products Canada Ltd. FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 Page 2 of 5 Photograph No.1 Setup for spurious field strength measurements in anechoic chamber from 9 kHz to 30 MHz Tyco Safety Products Canada Ltd. FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 Page 3 of 5 Photograph No.2 Setup for carrier and spurious emissions measurements in anechoic chamber from 30 MHz to 1 GHz Tyco Safety Products Canada Ltd. FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 Page 4 of 5 Photograph No.3 Setup for field strength measurements in anechoic chamber above 1 GHz Tyco Safety Products Canada Ltd. FCC ID: F5324PGPIO9 IC: 160A-PGP24IO9 Page 5 of 5 Photograph No.5 Setup for 20 dB bandwidth measurements

Contact Information

Applicant

Dan Nita(Approvals Manager)
[email protected]1-647-480-0430Fax: 1-647-480-0531

Technical Contact

Hermon Laboratories Ltd.Michael Nikishin
[email protected]972 4626 8440

Harakevet Industrial zone, P.O.Box 23 · Israel

Non-Technical Contact

Tyco Safety Products Canada Ltd.Dan Nita
[email protected]1-647-480-0430

Test Firm

Hermon Laboratories Ltd.George Shleimovich
[email protected]97246268468Fax: +972 4 626 8469

Technical Specifications

#Rule PartsFrequency RangePower Output
115C912.75 MHz - 919.106 MHz24.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Tyco Safety Products Canada Ltd.

IQ Lock-PGP, IQ Lock Touch-PGP - FCC ID F53252RFLOCK - Tyco Safety Products Canada Ltd.
F53252RFLOCK

IQ Lock-PGP, IQ Lock Touch-PGP

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
PowerG wireless transceiver module - FCC ID F5325PGPDC9 - Tyco Safety Products Canada Ltd.
F5325PGPDC9

PowerG wireless transceiver module

Apr 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Dual Technology Motion Sensor - FCC ID F5325LC203424 - Tyco Safety Products Canada Ltd.
F5325LC203424

Dual Technology Motion Sensor

Dec 17, 2025

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Wireless Motion detector with integrated camera - FCC ID F5323PGP9934P - Tyco Safety Products Canada Ltd.
F5323PGP9934P

Wireless Motion detector with integrated camera

Jan 16, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Transceiver - FCC ID F5323PGPHOST - Tyco Safety Products Canada Ltd.
F5323PGPHOST

Wireless Transceiver

Dec 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter