Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PGPHOST 2-Way Wireless Transciever The reference to PGPHOST throughout this document includes the model PGPHOST9. EN To download the full manual for this product, go to http://www.dsc.com/pdf/29011209 or scan the QR code. ES Para descargar el manual completo de este producto, vaya a http://www.dsc.com/pdf/29011243 o escanee el código QR. FR Pour télécharger les manuels complets,veuillez visiter http://www.dsc.com/pdf/29011242 ou scanner le code QR. FCC and ISED Compliance Statement This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. To comply with FCC Section 1.1310 for human exposure to radio frequency electromagnetic fields and IC requirements, implement the following instruction: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au cours de son fonctionnement normal. Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Product Certification PGPHOST complies with the following standards: PGPHOST9 FCC (915 MHz): 47CFR part 15 ISED (915MHz): RSS-247 UL/ULC: ULC-S304, UL1023, UL985, UL2610, ULC-S545, UL1637 UL/ULC notes The PGPHOST9 has been listed by UL/ULC for commercial burglary and residential fire/burglary applications and by ULC for residential burglary applications in accordance with the requirements in the Standards ULC-S304, UL1023, UL985, UL2610, ULC-S545, UL1637. For UL/ULC installations use these devices only in conjunction with compatible wireless receivers. After installation, verify the product functionality in conjunction with the compatible receiver used. Safety Instructions Read the safety information before you install the equipment. The transceiver shall be installed and used within an environment that provides the pollution degree max 2 and over voltages category II in non-hazardous locations, indoor only. The equipment is designed to be installed by SERVICE PERSONS only; (SERVICE PERSON is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). The device is to be installed in an indoor dry location. Exposure to weather or corrosive conditions may damage the unit. The transceiver shall be installed by Service Persons only (a service person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). It shall be installed and used within a non-hazardous, indoor environment only (pollution degree max 2, over voltages category II). The installer is responsible for instructing the system user with regards to electrical safety precautions when using a system which includes this equipment and also in regards to each of the following: - Do not attempt to service this product. There are no user serviceable parts inside. If servicing is required, it shall be referred to service persons only. - Using adequate mounting means, for example, plastic or metal anchors, secure the transceiver to the building structure before applying power. - Internal wiring shall be routed in a manner that prevents excessive strain on wire and on terminal connections, loosening of terminal or connections, or damage to conductor insulation. Limited Warranty Digital Security Controls (“DSC”), a division of Tyco Safety Products Canada Ltd, a part of the Johnson Controls group of companies (“JCI”), warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach o…
Text truncated - open the document above for the full version.
Tyco Safety Products Canada Ltd. 3301 Langstaff Road Concord, Ontario, Canada L4K 4L2 Tele: 1- 647-480-0200 https://www.tycosafetyproducts.com U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTEN TION: FCC Certification – Section 2.911(d)(7) Information Desi gnated U.S. Agent Company name: Qolsys Inc. FRN: 0022572226 Contact person name: Mark Skeen Street address: 1919 S. Bascom Ave. ZIP/City/State Campbell, CA 95008, USA Telephone number: Email address: [email protected] Signature: Date: 20230316 This l etter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The App licant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applic ant Company name: Tyco Safety Products Canada Ltd. Grantee Code: F53 Contact person name: Dan Nita Street address: 3301 Langstaff Road ZIP/City/State LK4 4L2, Concord, Ontario, Canada Telephone number: Email address: [email protected] Signature: Date: 20.3.2023 +1 (855) 476-5797 +1 (647) 8000430 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvdM 02 1 15-05-2023 Added FRN to Agent details RvdM Issued/modified by : Richard van der Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : __-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : __-02-2023
Tyco Safety Products Canada Ltd. 3301 Langstaff Road Concord, Ontario, Canada L4K 4L2 Tele: 1-647-480-0200 https://www.tycosafetyproducts.com Certification Application Attestation Statements Statement for 47 CFR section 2.911(d)(5)(i) Tyco Safety Products Canada Ltd. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Tyco Safety Products Canada Ltd. (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: City: Concord Name (2) : Dan Nita Function: Approvals Manager Telephone number: 1-647-480-0430 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” 29-Oct.- 23 Tyco Safety Products Canada Ltd. 3301 Langstaff Road L4K 4L2 Ontario, Canada Subject: FCC ID: F3523PGHOST To Whom It May Concern:
November 02, 2023 Telefication B.V. Attn: Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Application for certification for a Wireless Transceiver, FCC ID: F5323PGPHOST Dear Gentlemen, Please find attached our application for certification for a Wireless Transceiver, FCC ID: F5323PGPHOST, prepared in accordance with FCC Rules, parts 2 and 15, section 15.247(FHSS). The product testing and this application for certification were performed by Hermon Laboratories, which is recognized and accredited by FCC, Test Firm Registration Number is 927748, Designation Number is IL1001. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. We hope this application satisfies your requirements. Please send an invoice to Hermon Labs. Dan Nita, Approvals Manager Tyco Safety Products Canada Ltd.
FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 Company Name: Tyco Safety Products Canada Ltd. Address: 3301 Langstaff Road City: Concord L4K 4L2 Country: Ontario, Conada To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: F5323PGPHOST Reference number: 50991 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: in order to avoid exposed of the technology to the competitors Date: November 02, 2023 Name and signature of applicant: Mr. Dan Nita Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1
Tyco Safety Products Canada Ltd. 3301 Langstaff Road Concord, Ontario, Canada L4K 4L2 Tele: 1-647-480-0200 https://www.tycosafetyproducts.com Declaration of Authorization We Name: Tyco Safety Products Canada Ltd. Address: 3301 Langstaff Road City: Concord L4K 4L2 Country: Ontario, Canada Declare that: Name Representative of agent: Peysahov Sheynin Svetlana (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel is authorized to apply for Certification of the following product(s): Product description: Wireless Transceiver Type designation: PGPHOST Trademark: Johnson Controls Validity/expiry date: October 19, 2024 on our behalf. Date: October 31, 2023 Name: Dan Nita (2) Function: Approvals Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent
Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 2 of 3 Photograph No.1 Wireless Transceiver Front view Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 3 of 3 Photograph No.2 Wireless Transceiver Rear side view
ECM Title: JCI LABEL DRAWING TBD Product Name: LABEL PGH+ PGPHOST9 Date Name Document No: 4017717 01.08.2023 ALBERT F. Created Document Rev: 01 Updated Sheet 1 of 1 01.08.2023 SHAY A. Approved MATERIAL: Polyester S-0000-7 SIZE: 58 x 35 mm. Placement Product label:
Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 1 of 5 INTERNAL PHOTOGRAPHS This document contains 6 photographs Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 2 of 5 Photograph No.1 Wireless Transceiver Internal view Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 3 of 5 Photograph No.2 Wireless Transceiver Print side of the main PCB Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 4 of 5 Photograph No.3 Wireless Transceiver Antenna assembly Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 5 of 5
FCC ID: F5323PGPHOST Page 1 of 1 Environmental evaluation and exposure limit according to FCC CFR 47part 1, §1.1307, §1.1310 The Wireless Transceiver is classified as a mobile device. The Wireless Transceiver includes transmitter operating according to FCC part 15 subpart C section 15.247 (FHSS) The FCC limit for power density for general population/uncontrolled exposure is f/1500 mW/cm 2 for 300 – 1500 MHz frequency range: P = 912.75/1500 = 0.61 mW/cm 2 The power density P (mW/cm 2 ) = P T / 4 r 2 P T is the transmitted power, which is equal to the peak transmitter output power 13.17 dBm plus maximum antenna gain -1 dBi, the maximum equivalent isotropically radiated power EIRP is P T = 15.66 dBm + 7 dBi = 22.66 dBm = 184.5 mW. The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: Compliance with FCC limit: 16.48 mW / 4 (20 cm) 2 = 0.036 mW/cm 2 << 0.61 mW/cm 2 General public cannot be exposed to dangerous RF level.
Hermon Laboratories Ltd. 66 HaTachana str., P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 63 Report ID: VISRAD_FCC.50991_Rev2.docx Date of Issue: 6-Nov-23 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47CFR part 15 subpart C §15.247 (FHSS) and subpart B, RSS-247 Issue 2:2017, RSS-Gen Issue 5, ICES-003 Issue 7:2020 FOR: Tyco Safety Products Canada Ltd. Wireless Transceiver Model: PGPHOST9 FCC ID: F5323PGPHOST IC: 160A-PGPHOST This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC.50991_Rev2.docx Date of Issue: 6-Nov-23 Page 2 of 63 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in EUT .................................................................................................................................................. 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-247 requirements .................................................. 7 7.1 20 dB bandwidth ........................................................................................................................................................... 7 7.2 Carrier frequency separation ....................................................................................................................................... 11 7.3 Number of hopping frequencies .................................................................................................................................. 13 7.4 Average time of occupancy ......................................................................................................................................... 15 7.5 Peak output power ...................................................................................................................................................... 18 7.6 Field strength of spurious emissions ........................................................................................................................... 23 7.7 Band edge radiated emissions .................................................................................................................................... 36 7.8 Conducted emissions .................................................................................................................................................. 40 7.9 Antenna requirements ................................................................................................................................................. 45 8 Emissions tests according to FCC 47CFR part 15 subpart B and ICES-003 requirements......................................... 46 8.1 Conducted emissions .................................................................................................................................................. 46 8.2 Radiated emission measurements .............................................................................................................................. 51 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 56 10 APPENDIX B Test equipment correction factors ......................................................................................................... 57 11 APPENDIX C Measurement uncertainties .................................................................................................................. 60 12 APPENDIX D Test laboratory description ................................................................................................................... 61 13 APPENDIX E Specification references........................................................................................................................ 62 14 APPENDIX F Abbreviations and acronyms ................................................................................................................. 63 Report ID: VISRAD_FCC.50991_Rev2.docx Date of Issue: 6-Nov-23 Page 3 of 63 1 Applicant information Client name: Tyco Safety Products Canada Ltd. Address: 3301 Langs…
Text truncated - open the document above for the full version.
Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 1 of 5 SETUP PHOTOGRAPHS This document contains 5 photographs Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 2 of 5 Photograph No.1 Setup for spurious field strength measurements in anechoic chamber from 9 kHz to 30 MHz Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 3 of 5 Photograph No.2 Setup for carrier and spurious emissions measurements in anechoic chamber from 30 MHz to 1 GHz Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 4 of 5 Photograph No.3 Setup for field strength measurements in anechoic chamber above 1 GHz Tyco Safety Products Canada Ltd. FCC ID: F5323PGPHOST IC: 160A-PGPHOST Page 5 of 5 Photograph No.4 Setup for 20 dB bandwidth measurements
Harakevet Industrial zone, P.O.Box 23 · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912.75 MHz - 919.106 MHz | 36.00 mW |

IQ Lock-PGP, IQ Lock Touch-PGP
Equipment Class
DTS - Digital Transmission System
PowerG wireless transceiver module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Dual Technology Motion Sensor
Equipment Class
FDS - Part 15 Field Disturbance SensorWireless Input / Output (I/O) w/wo contact
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Motion detector with integrated camera
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter