FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Skytech II, Inc./
  3. K9LAF-4000PEHH

K9LAF-4000PEHHTransmitter

Skytech II, Inc.
Transmitter - FCC ID K9LAF-4000PEHH - Skytech II, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 13, 2006
Application Purpose
Original Equipment
Date of Application
Apr 13, 2006
Equipment Note
Transmitter
Frequency Range
303.80000000 - 303.80000000
Company
Skytech II, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Draft Function Dscription z Button A long push (5 seconds) of A1 & A2 buttons at the same time will start the Initial Set-up. At this time, a separate push for A1 &A2 buttons does not light any operations on the LCD. A short push of P button will enter into PROGRAM mode. A long push (5 seconds) of P button will enter into the setting for PROGRAM mode. *A long push (5 seconds) of TIMER & THERMO mode at the same time will activate or de-activate the CP feature. On/Off button for Manual mode AUX2 button AUX1 button Use this key to enter into & set Program mode Thermo mode set timer & cancel timer function Draft z LCD icon: Set Temperature: This will ONLY appear when the THERMOSTAT is activated - Timer: Timer Mode will appear and activate the Timer. - Manual ON: When manual ON , the MAN Icon will appear and when manual OFF the MAN icon will be eliminated - Program Mode: This icon will appear when the program is working - Thermostat : This icon will appear only when the Thermostatic Function is operating the fireplace. - Thermostat NOT : Tthis icon will ONLY appear(for 5 seconds) on the LCD screen when the Thermostatic function has been de-activated and someone will try to push the Thermostatic function button of the transmitter. This will show the user the thermostatic function is de-activated. Manual ON Program Timer Thermostat Thermostat NOT Set temperature thermo Battery low Flame UP Flame down FLAME AUX1 AUX2 Pacific energy company icon Program mode setting and display area CP:Chil d Proof Draft Notes: The range for the room temperature readout is 32-99 degree F. The room temperature always displays on the LCD. The range for set temperature is 45- 99 90degree F. The High Limit temperature for PROGRAM mode is 90 degree F. This High Limit termperature can not be changed by the users and Will only activate under PROGRAM mode. There is no High Limit temp for MANUAL & THERMO modes. The room temperature () always displays on the LCD The AUX1 and AUX 2 () do not light any operations on the LCD at this time. NOTE: Very Important to note Only one function can be going on at one time. You will have only one operation at a time going on with this system. The pressing of one of the function buttons will stop the operation that is going on with the fireplace and start the new function. Definition of Functions: Timer, Manual ON/OFF, Thermostat, and Program. Timer” is considered an independent function. The users are unable to set “Timer” function under Manual & Thermo modes. The users can adjust the Flame (operate the motor drive) under Manual ON, THERMO, TIMER & PROGRAM modes. SWING: Pacific Energy after discussion would like to have the following in the swing without the user having the ability to adjust this swing in any way. - Above the Room Temperature 1degree F and .5 degree C, 1 degree swing above - Below the Room Temperature 2 degree F and 1 degree C, 2 degree swing down THESE SETTING CANNOT BE CHANGED, IT IS SET AT THE FACTORY AND IN THE PROGRAM. It is not necessary to display SWING on the LCD.. Draft The FLAME icon will be ON all the time the flame in the fireplace is ON, whether it is under Manual ON, TIMER, THERMOSTAT or PROGRAM modes. The UP arrow will appear on the LCD when the motor drive is to be moving into the higher flame picture. Once the activation of the flame height is stopped, the UP icon on the LCD will disappear. The DOWN arrow will appear on the LCD when the motor drive is to be moving into the Lower flame picture. Once the activation of the flame height is stopped, the DOWN icon on the LCD will disappear. Operation Matrix Initial Set up: Push AUX 1 & AUX 2 buttons together for more than 5 seconds to start the process. 9 C/F conversion: Use UP or DOWN key to choose Celsius or Fahrenheit, then press OK to enter “TIME”. Setting. Use UP or DOWN key to set HOUR, then press OK to enter “Minute” setting. Use UP or DOWN key to set “Minute”, then press OK To enter AM/PM setting. Use UP or DOWN key to set AM/PM, the press OK to Enter “DAY” setting. Use UP or DOWN keys to set correct DAY, then press OK to finish the initial set up. The users must use OK button to confirm and enter into next setting. The icons will keep on flashing even though no button is pushed for more 5 seconds. H’ever, if no buttons is pushed for more than 2 minutes, the system will automatically confirm the completion of the process and the LCD will go back to Normal readouts. Temperature swing:. This is factory set and can not be changed at all. Draft Manual Mode: Push for manual ON, OFF. ON: The “man"() ICON will appear And the FLAME icon will appear too. OFF: The man () ICON will disappear and The FLAME icon will disappear too. .Flame modulation: The flame can only be modulated when the system is ON. The flame can be ON from the Manual, Timer, Thermostat and Program modes. The FLAME icon should be on all the time the flame in the fireplace is ON, whether It is operated in Manual, Timer, Thermostat or Program modes. The UP arrow will appear on the LCD when the motor drive is to be moving into the higher flame picture. Once the activatin of the flame height is stopped, the UP icon on the LCD will disappear. The DOWN arrow will appear on the LCD when the motor drive is to be moving into the Lower flame picture. Once the activation of the flame height is stopped, the DOWN icon on the LCD will disappear. Push (UP) button to operate flame motor drive UP. When this key is pushed, the UP icon will appear. The UP icon will disappear once the activation of the flame height is stopped (when the button is released.) Push (DOWN) button to operate flame motor drive DOWN. When this key is pushed, the DOWN icon will appear .The DOWN icon will disappear once the activation of the flame height is stopped (when the button is released). Draft .Timer function: Once this is selected, the timer () icon will be on the screen and the clock will flash “30"minutes as the start point. But the users still can go down to 10 minutes and up …

Text truncated - open the document above for the full version.

Block Diagram

Block Chart Key Input RF Signal Controller LCD Driver OSC. 455K Hz

External Photos

MAX LIGHT MEASUREMENT REPORT Technology Lab Page:1/5 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH MAX LIGHT MEASUREMENT REPORT Technology Lab Page:2/5 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH

ID Label/Location Info

MAX LIGHT MEASUREMENT REPORT Technology Lab Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Label Format: Label Position: Equipment Label 2.0cmX1.0cm This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received , including. Interference that may cause undesired operation. Model No. : AF-4000PEHH FCC ID: K9LAF-4000PEHH Rear View

Internal Photos

MAX LIGHT MEASUREMENT REPORT Technology Lab Page:3/5 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH MAX LIGHT MEASUREMENT REPORT Technology Lab Page:4/5 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH MAX LIGHT MEASUREMENT REPORT Technology Lab Page:5/5 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH

Operational Description

AF-4000PEHH receiver theory description Theory description: 1. Transmitter get electricity from battery. 2. Transmitter action control by user Key input. Some condition will send RF signal. Most action will show on the LCD. 3. MCU control all system’s operation. MCU A/D Memory IC RF module LCD Driver Key input

Schematics

1 2 34 ABCD 4 3 2 1 D CBA 1 FEGO Precision Industrial Co.,Ltd 1 2006/03/14 Size: Date: Revision:Sheet of Date A4 DateDate DRAFTERDESIGNERCHECKEDNAMEDWG NO. TEL:886-4-23391802 FAX:886-4-23399374 Product: R5100kR6熱敏 50 3 THERMOS CC2 1 VO15N 2 VEE 3 COM0 4 COM1 5 COM2 6 COM3 7 SEG0 8 SEG1 9 SEG2 10 SEG3 11 SEG4 12 SEG5 13 SEG6 14 SEG7 15 SEG8 16 SEG9 17 SEG10 18 SEG11 19 SEG12 20 SEG13 21 SEG14 22 SEG15 23 SEG16 24 SEG17 25 SEG18 26 SEG19 27 SEG20 28 SEG21 29 SEG22 30 SEG23 31 SEG24 32 SEG25 33 SEG26 34 SEG27 35 SEG28 36 SEG29 37 SEG30 38 SEG31 39 CS 40 RD 41 WR 42 DATA 43 VSS 44 OSC0 45 OSC1 46 VDD 47 IRQ 48 BZ 49 BZ 50 CC1 51 U2HT1620 Y2 32.768KHz C10104 C11104 R133M C12 104 3.3V COM0 COM1 COM2 COM3 R171M DATA IRQ CSWR SEG0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6SEG7SEG8SEG9 3.3V Key4ECS VBAT Key3 SNR THERMOS SEG10SEG11SEG12SEG13SEG14SEG15SEG16SEG17SEG18SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 SEG25 SEG26 SEG27 N15 N16 VREF RF SW2SW8 SW6SW9SW10 Key1Key2Key3 CS WR DATA SW1SW3SW4 SW5 Key1Key2 CSWR DATA OSCI R3100K SNR P56/CIN+ 1 P57/CO 2 P60/ADC1 3 P61/ADC2 4 VSS 5 P62/ADC3 6 P63/ADC4 7 P64/ADC5 8 P65/ADC6 9 P66/ADC7 10 P67/ADC8 11 P50/INT 12 P51/PWM1 13 P52/PWM2 14 P53/VREF 15 VDD 16 OSCO 17 OSCI 18 P54/TCC 19 P55/CIN- 20 U4EM78P458 OSCOIRQ Y1455K C8330PC9330P OSCIOSCO C13104 1 J1+ 1 J2 - 6V C1 100uF/16V C2 10U/16V R4光敏 R11MF510K VBAT R12MF510K 6V SW7 3.3V 3.3V 3.3V 3.3V CS 1 CLK 2 DI 3 DO 4 VSS 5 VCC 8 U393C46 R15 1K 3.3V Q3C945 6V ECSWR DATA B_Light R91K R81K R71K D21N4148D31N4148D51N4148 Key4 R1610K D41N4148 R220K VREF D11N4148 AD_PWM B_Light 0 K 1 A LED1R14750 AD_PWM 3.3V HT1620 有 pu ll hig h 電組 R1 27K R1010R C52P C31P C4 7P C7 103 L11UH ANT1 VC13P C610P Q2C3838 RF Circuit N4 N5 N6 RF 6V COM0COM1COM2COM3 123456789 1011121314151617181920212223242526272829303132 CON1LCD 朱德仁 IN I GND G OUT O Q1 HT7133 SEG0SEG1SEG2SEG3SEG4SEG5SEG6SEG7SEG8SEG9SEG10SEG11 SEG12SEG13SEG14SEG15SEG16SEG17SEG18SEG19SEG20SEG21SEG22SEG23SEG24SEG25SEG26SEG27 K1K2K3K4 S1 S2 S3 R2010K C14105 6V 0 K 1 A LED2 背光模組 R18750 新增 Q4,Q5,R21 ,R22 6V 0 K 1 A LED3R19750 BD1INDUCTOR BD2INDUCTOR Pacific Engery TX ECN Rev No. Revision Note Date Checked Drafter A N/A B 朱德仁 饒明惠 朱德仁 63146213 3BC0P101B 631463146314 N/A Test Pad all CON1 Test Pad Test Pad Test Pad Test Pad 原始版 Test Pad Test Pad Test Pad Q4C945 R2120K 3.3V Q5C945 R2220K AD_PWM 黃文志

Test Report

Product : Transmitter Applicant : SKYTECH II, INC. FCC ID : K9LAF-4000PEHH Trade Name : SKYTECH II Model : AF-4000PEHH Report No. : MLT0603P15002 Test Date : March 30, 2006 Test By Max Light Technology Co., Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Tel: 886-2-363-2447 Fax: 886-2-363-2597 T T h h e e t t e e s s t t r r e e p p o o r r t t c c o o n n s s i i s s t t s s o o f f 3 3 0 0 p p a a g g e e s s i i n n t t o o t t a a l l . . I I t t m m a a y y b b e e d d u u p p l l i i c c a a t t e e d d c c o o m m p p l l e e t t e e l l y y f f o o r r l l e e g g a a l l u u s s e e w w i i t t h h t t h h e e a a l l l l o o w w a a n n c c e e o o f f t t h h e e a a p p p p l l i i c c a a n n t t . . I I t t s s h h a a l l l l n n o o t t b b e e r r e e p p r r o o d d u u c c e e d d e e x x c c e e p p t t i i n n f f u u l l l l , , w w i i t t h h o o u u t t t t h h e e w w r r i i t t t t e e n n a a p p p p r r o o v v a a l l o o f f o o u u r r l l a a b b o o r r a a t t o o r r y y . . MAX LIGHT MEASUREMENT REPORT Page: 2/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab Table of Contents : I. General 4. II. Conducted Emissions Requirements 6. III. Radiated Emissions Requirements 7. IV. Transmitter Bandwidth Measurements 19. V. Transmitter Duty Cycle Measurements 21. VI. Verification of De-activation after 5 seconds 27. Appendix I (EUT Test Setup) 30 . MAX LIGHT MEASUREMENT REPORT Page: 3/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab CERTIFICATION We here by verify that : The test data, data evaluation, test procedures and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4: 2003. All test were conducted by MLT (Max Light Technology Co., Ltd) Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of each. We further submit that the energy emitted by the sample EUT tested as described in the report is in compliance with radiated emission limit of FCC Rules Part 15 Subpart C Section 15.231. EUT : Transmitter Applicant : SKYTECH II, INC. 9230 Conservation Way,Ft. Wayne, IN 46809, U.S.A. Manufacturer : FEGO Precision Industrial Co., Ltd. 947 LIN SEN RD., WU-FENG SHIANG TAICHUNG HSIEN R.O.C. Model No : AF-4000PEHH FCC ID : K9LAF-4000PEHH Prepared by : Approved by : Jesse Tein Roger Chen MAX LIGHT MEASUREMENT REPORT Page: 4/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab I. GENERAL 1.1 Introduction The following measurement report is submitted on behalf of SKYTECH II, INC. In support of an Intentional Periodic Radiator certification in accordance with Part 2 Subpart J and Part 15 Subpart A And C of the Commission’s and Regulations. 1.2 Description of EUT EUT : Transmitter Applicant : SKYTECH II, INC. 9230 Conservation Way,Ft. Wayne,IN 46809,U.S.A. Manufacturer : FEGO Precision Industrial Co., Ltd. 947 LIN SEN RD., WU-FENG SHIANG TAICHUNG HSIEN R.O.C. Model No : AF-4000PEHH FCC ID : K9LAF-4000PEHH Power Type : Powered by 6V Battery (AAA Size X4). The EUT (AF-4000PEHH) is remote transmitter. The operation frequency is 303.8Mhz. Press the button on remote transmitter, can set the Program mode / UP / DOWN / On / Off / TIMER / AUX1 / AUX2 / Thermo mode / OK Continuous Pilot button. MAX LIGHT MEASUREMENT REPORT Page: 5/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab 1.3 Description of Support Equipment The EUT itself forms a system. No support equipment is required for its normal operation. 1.4 Configuration of System Under Test 1.5 Test Procedure All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4: 2003 "Measurement of Intentional Radiators." 1.6 General Test Condition The conditions under which the EUT operates were varied to determine their effect on the equipment's emission characteristics. The final configuration of the test system and the mode of operation used during these tests was chosen as that which produced the highest emission levels. However, only those conditions which the EUT was considered likely to encounter in normal use were investigated. EUT MAX LIGHT MEASUREMENT REPORT Page: 6/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab II. Conducted Emissions Requirements The EUT operates solely by the battery. According to the rule of Section 15.207(c), the EUT exempt to the power line conducted test. MAX LIGHT MEASUREMENT REPORT Page: 7/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab III. Radiated Emissions Requirements 3.1 General Configuration: Prior to open-field testing, the EUT was placed in a shielded enclosure and scanned at a close distance to determine its emission characteristics. The physical arrangement of the EUT was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude, directivity, and frequency. The exact system configuration which produced the highest emissions was noted so it could be reproduced later during the open-field tests. This was done to ensure that the final measurements would demonstrate the worst-case interference potential of the EUT. 3.2 General Configuration: Final radiation measurements were made on a three-meter, open-field test site. The EUT system was placed on a nonconductive turntable which is 0.8 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 2.5 GHz in order to cover the whole spectrum below 10th harmonic which could generate from the EUT. During the test, EUT was set to transmit continuously & Measurements spectrum range from 30 MHz to5 GHz is investigated. For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quas…

Text truncated - open the document above for the full version.

Test Setup Photos

MAX LIGHT MEASUREMENT REPORT Page: 11/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab 3.4 Test Configuration: Front View of The Test Configuration MAX LIGHT MEASUREMENT REPORT Page: 12/30 Report Number: MLT0603P15002 FCC ID: K9LAF-4000PEHH Technology Lab Rear View of The Test Configuration

Contact Information

Applicant

Vincent Onaji(Engineering Project Manager)
[email protected]2609698608Fax: 260 459-1592

Test Firm

Max Light Technology Co., Ltd.Jesse Tien
[email protected]8862-266633486Fax: 866-2-26633582

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231303.8 MHz - 303.8 MHz-

Other Applications from Skytech II, Inc.

Remote control transmitter - FCC ID K9LAFTS3TX - Skytech II, Inc.
K9LAFTS3TX

Remote control transmitter

Jul 17, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
K9L8001TX

Remote Control Transmitter

Jun 05, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Remote Controller (TX) - FCC ID K9L-4001THATX - Skytech II, Inc.
K9L-4001THATX

Wireless Remote Controller (TX)

Apr 22, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
K9L3001-1TX

Remote Control

Feb 18, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Transmiter - FCC ID K9LREMOTION - Skytech II, Inc.
K9LREMOTION

Transmiter

Jul 16, 2013

Equipment Class

DTS - Digital Transmission System