Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AGENCY AUTHORIZATION LETTER To whom it may concern: We, the undersigned Skytech II, Inc., hereby authorize Max Light Technology Co. Ltd. (MLT) of Taiwan to act on our behalf in all matters relating to all processes required in the FCC Part 15 approval and any communication needed with the national authority. Any and all acts carried out by MLT on our behalf shall have the same effects as acts of our own. For questions regarding the authorization, please contact us. Thank you! Sincerely yours, _____________________________________ (Signature) Original written signature of authorized signer: Christopher Flick / CEO Printed name of authorized signer / Title Date: February 01, 2008
Date: 22, February 2008 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: K9LLEVEL3TX To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: Block Diagrams Schematics Operational Descriptions The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Christopher Flick / CEO _____________________________ (Signature) (Notice: Must be signed by applicant contact cited as technical or non-technical contact on the 731 form provided to ATCB, or by the authorized agent if an appropriate authorized agent letter has bee provided. Letters Signed by applicant should be placed on applicant letterhead.)
Report Number: MLT0801P15008 PHOTOGRAPHS OF EUT Report Number: MLT0801P15008
Report Number: MLT0801P15008 Label Format: Label Position: Equipment Label 4.0cmX3.2cm This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received , including Interference that may cause undesired operation. Model No. : LEVEL3 TX FCC ID: K9LLEVEL3TX Rear View
Report Number: MLT0801P15008 Report Number: MLT0801P15008 Report Number: MLT0801P15008 Report Number: MLT0801P15008
Page: 1/28 Report Number: MLT0801P15008 (FCC : Part 15 Subpart C / ANSI C63.4-2003) Product :Transmitter Trade Name :SKYTECH II Model No. :LEVEL3 TX Applicant :SKYTECH II, INC. Applicant Address :9230 Conservation Way,Ft. Wayne, IN 46809, U.S.A. Page: 2/28 Report Number: MLT0801P15008 Report Number MLT0801P15008 Applicant SKYTECH II, INC. Product Transmitter Sample Received Date 2008/01/22 Report Prepared By Jesse Tien Signature Date Prepared 2008/01/22 ~ 2008/01/30 Report Authorized By Roger Chen Signature Date Authorized 2008/02/15 Test By Max Light Technology Co., Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Office : Tel: 886-2-2363-2447 Fax: 886-2-2363-2597 Lab. : Tel: 886-2-2663-3486 Fax: 886-2-2663-3582 I I t t m m a a y y b b e e d d u u p p l l i i c c a a t t e e d d c c o o m m p p l l e e t t e e l l y y f f o o r r l l e e g g a a l l u u s s e e w w i i t t h h t t h h e e a a l l l l o o w w a a n n c c e e o o f f t t h h e e a a p p p p l l i i c c a a n n t t . . I I t t s s h h a a l l l l n n o o t t b b e e r r e e p p r r o o d d u u c c e e d d e e x x c c e e p p t t i i n n f f u u l l l l , , w w i i t t h h o o u u t t t t h h e e w w r r i i t t t t e e n n a a p p p p r r o o v v a a l l o o f f o o u u r r l l a a b b o o r r a a t t o o r r y y . . Page: 3/28 Report Number: MLT0801P15008 Table of Contents : 1. General 5. 2. Conducted Emissions Requirements 7 3. Radiated Emissions Requirements 8. 4. Transmitter Bandwidth Measurements 18. 5. Transmitter Duty Cycle Measurements 20. 6. Verification of De-activation after 5 seconds 24. Appendix I ( EUT Test Setup ) 27. Appendix II ( Brand / Trade Name & Model No. Multiple Listee ) 28. Page: 4/28 Report Number: MLT0801P15008 CERTIFICATION We here by verify that : The test data, data evaluation, test procedures and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4-2003. All test were conducted by MLT(Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of each. We further submit that the energy emitted by the sample EUT tested as described in the report is in compliance with radiated emission limit of FCC Rules Part 15 Subpart C Section 15.231. Applicant Name SKYTECH II, INC. Applicant Address 9230 Conservation Way,Ft. Wayne,IN 46809,U.S.A. Manufacturer Name FEGO Precision Industrial Co., Ltd. Manufacturer Address 947 LIN SEN RD., WU-FENG SHIANG TAICHUNG HSIEN R.O.C. Equipment Transmitter Model No LEVEL3 TX FCC ID K9LLEVEL3TX Report Prepared By Jesse Tien Signature Report Authorized By Roger Chen Signature Page: 5/28 Report Number: MLT0801P15008 1. GENERAL 1.1 Introduction The following measurement report is submitted on behalf of SKYTECH II, INC. In support of an Intentional Periodic Radiator certification in accordance with Part 2 Subpart J and Part 15 Subpart A And C of the Commission’s and Regulations. 1.2 Customer Details Applicant Name SKYTECH II, INC. Applicant Address 9230 Conservation Way,Ft. Wayne,IN 46809,U.S.A. Manufacturer Name FEGO Precision Industrial Co., Ltd. Manufacturer Address 947 LIN SEN RD., WU-FENG SHIANG TAICHUNG HSIEN R.O.C. 1.3 Technical data of EUT Equipment Transmitter Model No LEVEL3 TX FCC ID K9LLEVEL3TX Power Type Powered by 6V Battery (1.5V AAA Size X4). The EUT ( LEVEL3 TX ) is remote transmitter. The operation frequency is 303.8Mhz. Press the button on remote transmitter, can set the Program MENU / UP / DOWN / ON / OFF / SELECT Continuous Pilot button. 1.4 Description of Support Equipment The EUT itself forms a system. No support equipment is required for its normal operation. Page: 6/28 Report Number: MLT0801P15008 1.5 Configuration of System Under Test 1.6 Test Procedure All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4: 2003 "Measurement of Intentional Radiators." 1.7 General Test Condition The conditions under which the EUT operates were varied to determine their effect on the equipment's emission characteristics. The final configuration of the test system and the mode of operation used during these tests was chosen as that which produced the highest emission levels. However, only those conditions which the EUT was considered likely to encounter in normal use were investigated. EUT Page: 7/28 Report Number: MLT0801P15008 2. Conducted Emissions Requirements The EUT operates solely by the battery. According to the rule of Section 15.207(c), the EUT exempt to the power line conducted test. Page: 8/28 Report Number: MLT0801P15008 3. Radiated Emissions Requirements 3.1 General Configuration: Prior to open-field testing, the EUT was placed in a shielded enclosure and scanned at a close distance to determine its emission characteristics. The physical arrangement of the EUT was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude, directivity, and frequency. The exact system configuration which produced the highest emissions was noted so it could be reproduced later during the open-field tests. This was done to ensure that the final measurements would demonstrate the worst-case interference potential of the EUT. 3.2 General Configuration: Final radiation measurements were made on a three-meter, open-field test site. The EUT system was placed on a nonconductive turntable which is 0.8 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 2.5 GHz in order to cover the whole spectrum below 10th harmonic which could generate from the EUT. During the test, EUT was set to transmit continuously & Measurements spectrum range from 30 MHz to5 GHz is investigated. For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection measurements or 120 kHz for quasi-peak detection measurements. Peak detection is u…
Text truncated - open the document above for the full version.
Report Number: MLT0801P15008 Radiated Measurement Photos Front View of The Test Configuration Report Number: MLT0801P15008 Rear View of The Test Configuration
8F-No. 125 Sec. 3 Roosevelt Rd. · Taipei City · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 303.5 MHz - 303.5 MHz | - |

Remote control transmitter
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterRemote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Remote Controller (TX)
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterRemote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Transmiter
Equipment Class
DTS - Digital Transmission System