FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Scanreco AB/
  3. N5OD3DRCMP

N5OD3DRCMP2.4 GHz Transceiver

Scanreco AB

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 03, 2020
Application Purpose
Original Equipment
Date of Application
Feb 03, 2020
Equipment Note
2.4 GHz Transceiver
Frequency Range
2405.00000000 - 2480.00000000
Company
Scanreco AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Scanreco AB Stensätravägen 13, SE-127 39 Skärholmen Box 90304, SE-120 25 Stockholm, Sweden Tel +46 8 556 32 800 www.scanreco.com Portable control unit (transmitter) D3 DRC-MP D3 DRC-MP: 2.4 GHz transmitter Scanreco AB Stensätravägen 13, SE-127 39 Skärholmen Box 90304, SE-120 25 Stockholm, Sweden Tel +46 8 556 32 800 www.scanreco.com This product is intended to be installed in a Control unit system as a transmitter by Scanreco AB and it is designed preferably for wireless control of crane installations, travelling hoist units, chain and rope hoists, transfer carriages and similar applications. Terminal diagrams: Scanreco AB Stensätravägen 13, SE-127 39 Skärholmen Box 90304, SE-120 25 Stockholm, Sweden Tel +46 8 556 32 800 www.scanreco.com Radio part diagram: Radio specification: Attribute Information Frequency 2.405 – 2.480 GHz Channels 16 Channels management FHSS Channel bandwidth 2.7 MHz RF Power +18 dBm typical Modulation GFSK Range 100 meter Antenna specification: N Antenna type Details Manufacture Part number Connector Gain 1 Dipole antenna Total length 82 mm, Ø17mm Scanreco 50250 TNC 2 dBi 2 Striaght antenna 185 mm length, Ø13mm Nearson 102784 TNC/SMA 5 dBi Scanreco AB Stensätravägen 13, SE-127 39 Skärholmen Box 90304, SE-120 25 Stockholm, Sweden Tel +46 8 556 32 800 www.scanreco.com Installation description: Figure 1 Figure 2 1- Assemble D3 DRC-MP to box with screws. Torque =0.7Nm. 2- Screw antenna connector to PCBA. Torque = 0.56Nm 3- Assemble transparent plastic cover. Tightening torque = 0.7Nm, see Figure 2. Scanreco AB Stensätravägen 13, SE-127 39 Skärholmen Box 90304, SE-120 25 Stockholm, Sweden Tel +46 8 556 32 800 www.scanreco.com FCC information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesirable operation. Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada information This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. CAN ICES-3 (A)/NMB-3(A)

External Photos

Page 1 of 1 EUT is PCB, no enclosure. External photos are the same internal photos, internal photographs are confidential.

ID Label/Location Info

D3 DRC-MP label format and location On the host product shall be noted:

Test Report

Reference number: 295560-1-3 Page 1 of 46 These test results are valid for the tested unit only. This report shall not be reproduced, except in full, without a written permission of SGS Fimko. Test Report INTENTIONAL RADIATOR TESTS ACCORDING TO FCC PART 15 C AND ISED CANADA REQUIREMENTS Equipment Under Test: 2.4GHz radio module Model: D3 DRC-MP Manufacturer: Scanreco AB Stensätravägen 13 SE-127 39 Skärholmen, Sweden Customer: Scanreco AB Stensätravägen 13 SE-127 39 Skärholmen, Sweden FCC Rule Part: 15.247: 2017 IC Rule Part: RSS-247, Issue 2, 2017 RSS-GEN Issue 5 Amendment 1, 2019 KDB: 558074 D01 15.247 Meas Guidance v05r02 Guidance for Compliance Measurements on Digital Transmission Systems, Frequency Hopping Spread Spectrum System, and Hybrid System Devices Operating Under §15.247 of the FCC rules (April 2, 2019) Date: 12 August 2019 Date: 12 August 2019 Issued by: Checked by: Pekka Kälviäinen Rauno Repo Testing Engineer Senior EMC/RF Specialist Reference number: 295560-1-3 Page 2 of 46 Table of Contents GENERAL REMARKS .......................................................................................................................................... 3 Disclaimer ........................................................................................................................................................ 3 RELEASE HISTORY ............................................................................................................................................ 4 Page 11: measuring distance was added (3m) ............................................................................................... 4 Page 45: Calibration date of SMBV100A updated .......................................................................................... 4 PRODUCT DESCRIPTION .................................................................................................................................. 5 Equipment Under Test .................................................................................................................................... 5 General Description ......................................................................................................................................... 5 Ratings and declarations ................................................................................................................................. 5 Power Supply .................................................................................................................................................. 5 Mechanical Size of the EUT ............................................................................................................................ 5 SUMMARY OF TESTING ..................................................................................................................................... 6 EUT Test Conditions during Testing ............................................................................................................... 6 TEST RESULTS ................................................................................................................................................... 8 Antenna requirement ....................................................................................................................................... 8 Maximum Peak Conducted Output Power ...................................................................................................... 9 Transmitter Radiated Spurious Emissions 9 kHz – 26.5 GHz ........................................................................ 12 Transmitter Band Edge Measurement and Conducted Spurious Emissions .................................................. 20 20 dB Bandwidth of the Hopping Channel ...................................................................................................... 28 Hopping Channel Carrier Frequencies Separation ......................................................................................... 31 Number of Hopping Channels ......................................................................................................................... 34 Average Time of Occupancy of Hopping Frequency ...................................................................................... 36 6 dB Bandwidth of the Channel ....................................................................................................................... 39 99% Occupied Bandwidth ............................................................................................................................... 42 Duty cycle correction factor, Transmit time in 100 ms .................................................................................... 45 TEST EQUIPMENT .............................................................................................................................................. 46 Reference number: 295560-1-3 Page 3 of 46 General Remarks GENERAL REMARKS Disclaimer This document is issued by the Company under its General Conditions of service accessible at http://www.sgs.com/terms_and_conditions.htm. attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company's findings at the time of its intervention only and within the limits of Client's instructions, if any. The Company's sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. This document cannot …

Text truncated - open the document above for the full version.

Test Report

P26,40dBm Tune-up tolerance 0,50dB Duty Cycle8,52% P average41,73mW d200mm f2480MHz x7,5for 1-g SAR SAR exclusion0,33<7.5 Limit7,5 Pmax953mW * calculated using 447498 D01 General RF Exposure Guidance v05r02 section 4.3.1 1) [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)

Test Setup Photos

Test Setup Photographs 295560-1-3 Scanreco DRC-MP D3 Photograph 1. Radiated Spurious Emissions 9 kHz – 30 MHz Photograph 2. Radiated Spurious Emissions 30 MHz – 1000 MHz Test Setup Photographs 295560-1-3 Scanreco DRC-MP D3 2/3 Photograph 3. Radiated Spurious Emissions 1 GHz – 18 GHz Photograph 4. Radiated Spurious Emissions 18 GHz – 26.5 GHz Test Setup Photographs 295560-1-3 Scanreco DRC-MP D3 3/3 Photograph 5. EUT position during radiated tests Photograph 6. FCC Conducted measurement

Contact Information

Applicant

Bjorn Askestig(Vice President)
[email protected]46-8-556-32-801Fax: 1-778-298-8404

Technical Contact

Scanerco ABElnaz Farzaneh
[email protected]46724514632

Scanreco AB · Stockholm · Sweden

Non-Technical Contact

Scanerco ABBjorn Askestig
[email protected]46855632801

Test Firm

SGS Fimko OyJanne Nyman
[email protected]+358 9 696 361Fax: +358-9-696-5474

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz105.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
The output power listed is conducted. Modular Approval. Compliance of this device in all final product configurations is the responsibility of the Grantee. Installation of this device into specific final products may require a submission of a Class II permissive change application containing data pertinent to RF Exposure, emissions and host / module authentication, or a new application if appropriate. This device is approved for both fixed and mobile use with respect to RF exposure compliance. The antenna of this transmitter must provide a separation distance defined in this application from all persons. Installers and end-users must be provided with operating conditions for satisfying RF exposure compliance. Multi-transmitter, supporting simultaneous transmission, configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and &sect;15.31(h) and &sect;15.31 (k) composite system.

Other Applications from Scanreco AB

TR06 Transceiver Module - FCC ID N5OTR064 - Scanreco AB
N5OTR064

TR06 Transceiver Module

Apr 25, 2021

Equipment Class

DTS - Digital Transmission System
N5OD3DRCJ

2.4 GHz Transceiver

Apr 21, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2.4 GHz Transceiver Model Number DRC-10 D3, DRC-10 2ST D3 - FCC ID N5OD3DRC10 - Scanreco AB
N5OD3DRC10

2.4 GHz Transceiver Model Number DRC-10 D3, DRC-10 2ST D3

Aug 26, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
DRC-DR D3,  DRC-BM D3 - FCC ID N5OD3DRCDRBM - Scanreco AB
N5OD3DRCDRBM

DRC-DR D3, DRC-BM D3

Aug 25, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2.4 GHz Transceiver - FCC ID N5OTR05 - Scanreco AB
N5OTR05

2.4 GHz Transceiver

Sep 02, 2014

Equipment Class