FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhuhai FTZ Oplink Communications, Inc./
  3. OS3OPU01

OS3OPU01OPU Wireless AP/Router

Zhuhai FTZ Oplink Communications, Inc.
OPU Wireless AP/Router - FCC ID OS3OPU01 - Zhuhai FTZ Oplink Communications, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 12, 2012
Application Purpose
Original Equipment
Date of Application
Sep 12, 2012
Equipment Note
OPU Wireless AP/Router
Frequency Range
2422.00000000 - 2452.00000000
Company
Zhuhai FTZ Oplink Communications, Inc.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Oplink Communications Zhuhai FTZ Oplink Communications, Inc. OPU1120 UserGuide Oplink Communications Content CHAPTER 1 PRODUCT OVERVIEW ................................................................ 3 1.1 PRODUCTION INTRODUCTION ......................................................................... 3 1.2 PRODUCTS FEATURES ..................................................................................... 5 1.3 PACKAGE CONTENTS ....................................................................................... 6 1.4 LED INDICATOR AND PORT DESCRIPTION ...................................................... 7 CHAPTER 2 HARDWARE INSTALLATION .................................................... 9 2.1 HOW TO INSTALL THE ROUTER ....................................................................... 9 CHAPTER 3 WORKING MODES INTRODUCTION .................................... 11 3.1 AP MODE ...................................................................................................... 11 3.2 CLIENT+AP MODE ....................................................................................... 12 3.3 WDS+AP MODE .......................................................................................... 13 3.4 WISP MODE ................................................................................................. 13 3.5 WIRELESS ROUTER MODE ............................................................................ 14 CHAPTER 4 HOW TO LOGIN TO THE ROUTER........................................ 14 4.1 HOW TO SET THE WIRED NETWORK CONFIGURATIONS................................ 14 4.2 LOGIN TO THE WEB INTERFACE .................................................................... 17 CHAPTER 5 WORKING MODES SETUP WIZARD ..................................... 19 5.1. AP MODE ..................................................................................................... 19 5.2. CLIENT+AP ................................................................................................. 20 5.2.3. WIRELESS BASIC SETTING........................................................................ 21 5.2.4. WIRELESS SECURITY SETTINGS ................................................................ 23 5.3. WDS+AP MODE SETUP WIZARD ................................................................ 24 5.4 WISP MODE ................................................................................................. 27 5.5 WIRELESS ROUTER MODE ............................................................................ 30 CHAPTER 6 ADVANCED SETTINGS .............................................................. 37 6.1 LAN SETTINGS ............................................................................................. 37 6.2 WA N SETTINGS ............................................................................................ 40 6.3 MAC ADDRESS CLONE ................................................................................ 44 6.4 DNS SETTINGS ............................................................................................. 44 CHAPTER 7 WIRELESS SETTING ................................................................. 46 7.1 BASIC SETTINGS ........................................................................................... 46 7.2 WIRELESS SECURITY SETTING ..................................................................... 48 7.3 ADVANCED SETTINGS ................................................................................... 51 7.4 WPS SETTINGS ............................................................................................. 53 7.5 WIRELESS ACCESS CONTROL ....................................................................... 56 Oplink Communications 7.6 CONNECTION STAT U S ................................................................................... 57 CHAPTER 8 DHCP SERVER ............................................................................. 58 8.1 DHCP SETTINGS .......................................................................................... 58 8.2 DHCP LIST AND BINDING ............................................................................ 59 CHAPTER 9 VIRTUAL SERVER ...................................................................... 61 9.1 PORT RANGE FORWARDING .......................................................................... 61 9.2 DMZ SETTINGS ............................................................................................ 63 9.3 UPNP SETTINGS ........................................................................................... 64 CHAPTER 10 SECURITY SETTINGS ............................................................. 65 10.1 CLIENT FILTER SETTINGS ........................................................................... 65 10.2 URL FILTER SETTINGS ............................................................................... 66 10.3 MAC ADDRESS FILTER............................................................................... 68 10.4 PREVENT NETWORK ATTACK...................................................................... 69 10.5 REMOTE WEB MANAGEMENT ................................................................... 70 10.6 WA N PING .................................................................................................. 72 CHAPTER 11 ROUTING SETTING ................................................................. 72 11.1 ROUTING TABLE ......................................................................................... 72 CHAPTER 12 SYSTEM TOOLS ........................................................................ 73 12.1 TIME SETTINGS ........................................................................................... 73 12.2 DDNS ......................................................................................................... 74 12.3 BACKUP/RESTORE SETTINGS ..................................................................... 76 12.4 REST…

Text truncated - open the document above for the full version.

Cover Letter(s)

Zhuhai FTZ Oplink Communications, Inc. Add: #29, #30 Lianfeng Avenue,Free Trade Zone, Zhuhai City, Guangdong Province,China 591030 Tel:(86 756)881-9682 Fax:(86 756)868-6790 FCC Authorization Date: 2012-9-7 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Zhuhai FTZ Oplink Communications, Inc., the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Printed Name :Lizhi Li Title: Project Manager

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3

Internal Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3

Operational Description

  FCC  Thi s Ban the dat a  Th e por  For ma n Oplink Com C ID:OS3O sdeviceisa nd;themaxi signalton aratewith etransmitte t,The1db moredeta nual. mmunication OPU01 a802.11bgn mumdata oiseradioi DSSStechn eroftheEU biantennai iledinstitut s Operat nWLANW ratecould stoopoor niquewillb UTispowere spcbanten tions,plea EUTG tional Desc WirelessRou beupto1 whichcou l beapplied. edbyAdap nna  asetakealo eneralDesc cription ter,which o 50Mbpswh ldnotsupp pter(DC5V1 ookattheB cription operatesin2 hichOFDM port150Mb .2A)orpow BlockDiagr 2.412-2462 technique bps,the11M weredbyus ramandus 2Ghz .if Mbps sb ser

RF Exposure Info

Report No.: SA120808C34A of 5 Report Format Version 5.0.0 Reference No.: 120809C11 1 RF EXPOSURE REPORT REPORT NO.: SA120808C34A MODEL NO.: OPU1120 FCC ID: OS3OPU01 RECEIVED: Aug. 08, 2012 TESTED: Aug. 25 ~ Aug. 27, 2012 ISSUED: Aug. 29, 2012 APPLICANT: Zhuhai FTZ Oplink Communications, Inc. ADDRESS: #29, #30 Lianfeng Avenue, Free Trade Zone, Zhuhai City, Guangdong Province, China 591030 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-com pliance to the specification. Report No.: SA120808C34A of 5 Report Format Version 5.0.0 Reference No.: 120809C11 2 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................ 3 1. CERTIFICATION ............................................................................................................. 4 2. RF EXPOSURE ............................................................................................................... 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ......................................... 5 2.2 MPE CALCULATION FORMULA .................................................................................... 5 2.3 CLASSIFICATION ........................................................................................................... 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER .................................. 5 Report No.: SA120808C34A of 5 Report Format Version 5.0.0 Reference No.: 120809C11 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA120808C34A Original release Aug. 29, 2012 Report No.: SA120808C34A of 5 Report Format Version 5.0.0 Reference No.: 120809C11 4 1. CERTIFICATION PRODUCT: OPU MODEL: OPU1120 BRAND: Oplink APPLICANT: Zhuhai FTZ Oplink Communications, Inc. TESTED: Aug. 25 ~ Aug. 27, 2012 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: OPU1120) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE :Aug. 29, 2012 Joanna Wang / Supervisor APPROVED BY : , DATE :Aug. 29, 2012 Gary Chang / Technical Manager Report No.: SA120808C34A of 5 Report Format Version 5.0.0 Reference No.: 120809C11 5 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (dBm) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 2412-2462 20.92 1 20 0.031 1

Test Report

Report No.: RF120808C34A 1 of 48 Report Format Version 5.0.0 Reference No.: 120808C34, 120809C11 FCC TEST REPORT REPORT NO.: RF120808C34A MODEL NO.: OPU1120 FCC ID: OS3OPU01 RECEIVED: Aug. 08, 2012 TESTED: Aug. 25 ~ Aug. 27, 2012 ISSUED: Aug. 29, 2012 APPLICANT: Zhuhai FTZ Oplink Communications, Inc. ADDRESS: #29, #30 Lianfeng Avenue, Free Trade Zone, Zhuhai City, Guangdong Province, China 591030 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF120808C34A 2 of 48 Report Format Version 5.0.0 Reference No.: 120808C34, 120809C11 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................................ 4 1. CERTIFICATION ............................................................................................................................ 5 2. SUMMARY OF TEST RESULTS ................................................................................................... 6 2.1 MEASUREMENT UNCERTAINTY ................................................................................................ 6 3. GENERAL INFORMATION ............................................................................................................ 7 3.1 GENERAL DESCRIPTION OF EUT .............................................................................................. 7 3.2 DESCRIPTION OF TEST MODES ................................................................................................ 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................................................ 9 3.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................ 11 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ......................................................................... 11 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................. 12 4. TEST TYPES AND RESULTS ..................................................................................................... 13 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT ..................................................... 13 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ................................... 13 4.1.2 TEST INSTRUMENTS ................................................................................................................. 14 4.1.3 TEST PROCEDURES ................................................................................................................. 15 4.1.4 DEVIATION FROM TEST STANDARD ....................................................................................... 15 4.1.5 TEST SETUP ............................................................................................................................... 16 4.1.6 EUT OPERATING CONDITIONS ................................................................................................ 16 4.1.7 TEST RESULTS .......................................................................................................................... 17 4.2 CONDUCTED EMISSION MEASUREMENT .............................................................................. 30 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ........................................................... 30 4.2.2 TEST INSTRUMENTS ................................................................................................................. 30 4.2.3 TEST PROCEDURES ................................................................................................................. 31 4.2.4 DEVIATION FROM TEST STANDARD ....................................................................................... 31 4.2.5 TEST SETUP ............................................................................................................................... 31 4.2.6 EUT OPERATING CONDITIONS ................................................................................................ 31 4.2.7 TEST RESULTS .......................................................................................................................... 32 4.3 6dB BANDWIDTH MEASUREMENT .......................................................................................... 34 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT ............................…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION Conducted Emission Test 2 Radiated Emission Test

Contact Information

Applicant

Lizhi Li(Engineer)
[email protected](86 756) 8819682Fax: (86 756) 8686790

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-260-0884Fax: +886-3-211-5834

Technical Specifications

#Rule PartsFrequency RangePower Output
415C2.42 GHz - 2.45 GHz111.90 mW
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Zhuhai FTZ Oplink Communications, Inc.

Oplink Processing Unit Router - FCC ID OS3OPU04 - Zhuhai FTZ Oplink Communications, Inc.
OS3OPU04

Oplink Processing Unit Router

Sep 23, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless IP camera - FCC ID OS3IPC05 - Zhuhai FTZ Oplink Communications, Inc.
OS3IPC05

Wireless IP camera

Aug 10, 2014

Equipment Class

DTS - Digital Transmission System
Wireless IP Camera - FCC ID OS3IPC04 - Zhuhai FTZ Oplink Communications, Inc.
OS3IPC04

Wireless IP Camera

May 15, 2014

Equipment Class

DTS - Digital Transmission System
Water Leak Sensor - FCC ID OS3WLS01 - Zhuhai FTZ Oplink Communications, Inc.
OS3WLS01

Water Leak Sensor

Apr 28, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Garage Door Sensor - FCC ID OS3GDS01 - Zhuhai FTZ Oplink Communications, Inc.
OS3GDS01

Garage Door Sensor

Apr 28, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter