FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schlage Electronic Security/
  3. P2GPX

P2GPXDoor Lock

Schlage Electronic Security
Door Lock - FCC ID P2GPX - Schlage Electronic Security
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 25, 2003
Application Purpose
Original Equipment
Date of Application
Aug 25, 2003
Equipment Note
Door Lock
Frequency Range
0.12500000 - 0.12500000
Company
Schlage Electronic Security
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CM 5600 Installation Instructions CM5600 Installation Instructions ¹⁄₈ ⁵⁄₃₂ 1⁷⁄₈ ¹⁄₈ CM 5600 Installation Instructions CM 5600 Installation Instructions CM 5600 Installation Instructions

Cover Letter(s)

Response to TCB Findings 1. Please provide the test set-up photos. Response: Provided 2. Has the loop antenna been rotated to maximize emissions? Response: Yes, please see the revised test report 3. Please provide details of measurement instrumentation detector and receiver settings upto 1GHz. Response: Clarified in the revised test report 4. Please provide a detailed list of models intended to be covered with this application. Please also describe the differences if any. Response: Clarified in the test report. Please also see the attached model information document. 5. The operational description states that the transmitter/receiver antenna is designed and integrated into the final product by OEM. If that’s the case OEM needs to get approval for the transmitter. Response: Locknetics is the OEM and the transmitter will be registered under their name. The design and operational description were provided by HID.

External Photos

REPORT: ED0128-2 FCC ID: P2GPX EXHIBIT: External Photos MODEL: CM5690 Page 1 of 1 _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828

Internal Photos

REPORT: ED0128-2 FCC ID: P2GPX EXHIBIT: Internal Photos MODEL: CM5690 Page 1 of 1 _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 REPORT: ED0128-2 FCC ID: P2GPX EXHIBIT: Internal Photos MODEL: CM5690 Page 2 of 2 _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 REPORT: ED0128-2 FCC ID: P2GPX EXHIBIT: Internal Photos MODEL: CM5690 Page 3 of 3 _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 REPORT: ED0128-2 FCC ID: P2GPX EXHIBIT: Internal Photos MODEL: CM5690 Page 4 of 4 _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828

Test Report

Test Report Report No ED0128-1 Client Locknetics Security Engineering 575 Birch Street Forestville, CT 06010 Phone (860) 314-5248 Fax (860) 314-2452 FRN 0005178298 Models CM 5600 Series FCC ID P2GPX Equipment Type Low Power Communication Device Transmitter Equipment Code DXX Results As detailed within this report Prepared by _____________________ Evan Gould – Test Engineer Authorized by __________________________ Michael Buchholz – EMC Manager Issue Date 8/11/03 Conditions of issue This Test Report is issued subject to the conditions stated in ‘terms and conditions’ section of this report. Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 REPORT: ED0128-1 FCC ID: P2GPX _____________________________________________________________ Table Of Contents Summary..............................................................................................................3 Test Methodology.................................................................................................3 EUT Configuration................................................................................................4 Statement of Conformity.......................................................................................5 Fundamental and Harmonic Emissions................................................................6 AC Line Conducted Emission Measurements.......................................................7 Voltage Variation...................................................................................................8 Test Equipment Used...........................................................................................9 Terms And Conditions........................................................................................10 A2LA Accreditation.............................................................................................12 _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 14 REPORT: ED0128-1 FCC ID: P2GPX _____________________________________________________________ Summary This report is an application for certification of transmitters operating pursuant to 47 CFR 15.209. The products are the Schlage CM 5600 Series locks with the PX credential type option. The PX specifies the combination of HID proximity and iButton credentials. The specific product tested was the CM 5690 with PX, FSA, and ME options. The difference between the model numbers 5690, 5691, 5693, 5694, and 5696 is purely the mechanical lock assembly. See attached “P2GPX – Model Descriptions” for clarification regarding the different model numbers and options. Test Methodology Radiated emissions testing is performed according to the procedures specified in ANSI C63.4 (2000). Receiving loop antenna was rotated in order to maximize radiated emission measurements. Frequency range investigated: 9kHz – 1GHz Measurement distance: 3m AC Line conducted emissions testing was performed with a 50Ω/50μH LISN. _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 3 of 14 REPORT: ED0128-1 FCC ID: P2GPX _____________________________________________________________ EUT Configuration EUT Configuration Work Order: D0128 Company: Locknetics Security Engineering Company Address: 575 Birch Street Forestville, CT 06010 Contact: Adam O'Day Person Present: Adam O'Day MNSNFCC ID EUT: CM5690 (PX, FSA, ME) EUT Description: CM5600 Mortise Series EUT Max Fre quency: 9.8MHz Support Equipment: MNSN OEM 24VDC AC AdaptorAD-2450- EUT Cables: QtyShielded?LengthFerrites DC Cable1no2mno Unpopulated EUT Ports: QtyReason none Software / Operating Mode Description: Operating normally; locked; oscillators are running _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 4 of 14 REPORT: ED0128-1 FCC ID: P2GPX _____________________________________________________________ Statement of Conformity The Locknetics CM 5690 has been found to conform with the following parts of the 47 CFR as detailed below: Part 2 Part 15 Comments 15.15(b) The product contains no user accessible controls that increase transmission power above allowable levels. 2.925 15.19 The label is shown in the label exhibit. 15.21 Information to the user is shown in the instruction manual exhibit. 15.27 No special accessories are required for compliance. 15.203 The antenna is not accessible to the user and therefore cannot be easily removed. (The antenna and its connector are underneath the PCB assembly which is in turn professionally installed in the door lock enclosure.) 15.205 15.209 The fundamental is not in a Restricted band and the spurious and harmonic emissions in the Restricted bands comply with the general emission limits of 15.209. 15.207 The unit meets the AC line conducted emissions requirements of 15.207. _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 5 of 14 REPORT: ED0128-1 FCC ID: P2GPX _____________________________________________________________ Fundamental and Harmonic Emissions LIMITS Frequency (MHz) Field strength (microvolts/meter) Measurement distance (meters) 0.009-0.490 2400/F(kHz) 300 0.490-1.705 24000/F(kHz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 [15.209(a)] MEASUREMENTS Fundamental and Harmonics (9kHz-1GHz) Curtis-Straus LLC Date: 19-Feb-03 Engineer: Evan…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT: ED0128-1 FCC ID: P2GPX EXHIBIT: Setup Photos MODEL: CM 5690 _____________________________________________________________ Radiated Emissions _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 1 of 3 REPORT: ED0128-1 FCC ID: P2GPX EXHIBIT: Setup Photos MODEL: CM 5690 _____________________________________________________________ Radiated Emissions _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 3 REPORT: ED0128-1 FCC ID: P2GPX EXHIBIT: Setup Photos MODEL: CM 5690 _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 3 of 3 Conducted Emissions

Contact Information

Applicant

Adam O'Day(Electronic Engineer)
[email protected]860-314-5248Fax: 860-584-2136

Test Firm

Curtis-Straus LLCJonathan Stewart
[email protected]978-486-8880Fax: 978-486-8828

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Schlage Electronic Security

Door Lock with Proximity Reader Transmitter - FCC ID P2G-RDR-ICL - Schlage Electronic Security
P2G-RDR-ICL

Door Lock with Proximity Reader Transmitter

Feb 06, 2005

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Door Lock - FCC ID P2GPXH - Schlage Electronic Security
P2GPXH

Door Lock

Oct 25, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Door Lock - FCC ID P2GVIP - Schlage Electronic Security
P2GVIP

Door Lock

Feb 09, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Door Lock - FCC ID P2G2PXI - Schlage Electronic Security
P2G2PXI

Door Lock

Feb 04, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Door Lock - FCC ID P2GPROXIF - Schlage Electronic Security
P2GPROXIF

Door Lock

Jan 15, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter