Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
7/64” HEX WRENCH 7/64” HEX WRENCH SG NS ANT-TAMPER PLUG FIELD CONNECTIONS (IF REQUIRED) DO NOT CUT THIS PLUG OFF. USE INTERFACE CABLE PROVIDED. IT MAY BE NECESSARY TO CUT INTERFACE CABLE IN ORDER TO PULL IT THROUGH CONDUIT, ETC. IF NECESSARY BE SURE TO MAKE GOOD QUALITY FIELD CONNECTIONS. ANT-TAMPER PLUG 2 3/4” 3 5/16” 3/4” DRILL/TAP 6-32 TYP(2) FIELD CONNECTIONS (IF REQUIRED) SEE SYSTEM INSTRUCTIONS FOR MORE INFORMATION. FORM 77005 Rev. A10/25/2004 MODULAR READER INSTRUCTIONS: KP, MG, PXH This device complies with part 15 of the FCC rules. Operation is sub- ject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including any interference that may cause undesired opera- tion. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Note for PXH models only:
Response to TCB Findings Question - Please confirm that a loop antenna has been used below 30MHz. Response - Yes, it was the same loop that was used to measure the fundamental.
REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: External Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 1 of 2 REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: External Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 2
REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: Internal Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 1 of 3 REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: Internal Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 3 REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: Internal Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 3 of 3
Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Test Report Report No EE0696-1 Client Locknetics Security Engineering 575 Birch Street Forestville, CT 06010 Phone (860) 314-5248 Fax (860) 314-2452 FRN 0005178298 Model PXH FCC ID P2GPXH Equipment Type Low Power Communication Device Transmitter Equipment Code DXX Results As detailed within this report Prepared by _____________________ Evan Gould – Test Engineer Authorized by __________________________ Michael Buchholz – EMC Manager Issue Date 9/30/04 Conditions of issue This Test Report is issued subject to the conditions stated in ‘terms and conditions’ section of this report. REPORT: EE0696-1 FCC ID: P2GPXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 16 Table Of Contents Summary..............................................................................................................3 Test Methodology.................................................................................................3 EUT Configuration................................................................................................4 Statement of Conformity.......................................................................................5 Fundamental.........................................................................................................6 Spurious Emissions..............................................................................................7 AC Line Conducted Emission Measurements.......................................................8 Voltage Variation...................................................................................................9 Test Equipment Used.........................................................................................10 Terms And Conditions........................................................................................12 A2LA Accreditation.............................................................................................14 REPORT: EE0696-1 FCC ID: P2GPXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 3 of 16 Summary This report is an application for certification of a transmitter operating pursuant to 47 CFR 15.209. The product is the PXH modular hardwired credential. It transmits at 125kHz, and detects the presence of an access card. The unit is used in conjunction with a Network Control Module. Test Methodology Radiated emissions testing is performed according to the procedures specified in ANSI C63.4 (2003). To maximize emissions, the EUT was rotated around it’s vertical axis and the receiving antenna’s height and polarity was varied. Frequency range investigated: 9kHz – 1GHz Measurement distance: 9kHz – 30MHz 1m 30MHz – 1000MHz 3m AC Line conducted emissions testing was performed with a 50Ω/50μH LISN. REPORT: EE0696-1 FCC ID: P2GPXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 4 of 16 EUT Configuration EUT Configuration Work Order: E0696 Company: Locknetics Security Engineering Company Address: 575 Birch Street Forestville, CT 06010 Contact: Adam ODay MNSNFCC ID EUT: PXH-P2GPXH EUT Max Fre quency: 9.8MHz Support Equipment: MNSN Network Control ModuleNCM- EUT Cables: QtyShielded?LengthFerrites AC power cable1no1.5mno Credential comm cable1no4.5mno Unpopulated EUT Ports: QtyReason none Software / Operating Mode Description: The credential system was exercised by waving a pass card in front of the credential reader. The system would then open and close the lock relay. REPORT: EE0696-1 FCC ID: P2GPXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 5 of 16 Statement of Conformity The PXH has been found to conform with the following parts of the 47 CFR as detailed below: Part 2 Part 15 Comments 15.15(b) The product contains no user accessible controls that increase transmission power above allowable levels. 2.925 15.19 The label is shown in the label exhibit. 15.21 Information to the user is shown in the instruction manual exhibit. 15.27 No special accessories are required for compliance. 15.203 The antenna is not accessible to the user and therefore cannot be easily removed. 15.205 15.209 The fundamental is not in a Restricted band and the spurious and harmonic emissions in the Restricted bands comply with the general emission limits of 15.209. 15.207 The unit meets the AC line conducted emissions requirements of 15.207. REPORT: EE0696-1 FCC ID: P2GPXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 6 of 16 Fundamental LIMITS Frequency (MHz) Field strength (microvolts/meter) Measurement distance (meters) 0.009-0.490 2400/F(kHz) 300 0.490-1.705 24000/F(kHz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 [15.209(a)] MEASUREMENT Radiated Emissions Table Curtis-Straus LLC Date: 30-Aug-04 Company: Locknetics Security Engineering Work Order: E0…
Text truncated - open the document above for the full version.
REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: Setup Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 1 of 2 Radiated Emissions Radiated Emissions REPORT: EE0696-1 FCC ID: P2GPXH EXHIBIT: Setup Photos MODEL: PXH _____________________________________________________________ _____________________________________________________________ Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 2 Conducted Emissions Voltage Variations
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

Door Lock with Proximity Reader Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Door Lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Door Lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Door Lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Door Lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter