Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Test Setup FCCID : PEQ735791102 External Photo -front External Photo - rear
FCC ID : PEQ735791102 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not ca- use harmful interference , and (2) this device must accept any inte- rference received, including interference that may cause undesired operation. 40mm 10mm
Test Setup FCCID : PEQ735790403 Internal Photo - 1 Internal Photo - 2 Test Setup FCCID : PEQ735790403 Internal Photo β 3 Internal Photo β 4
β’ The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. β’ This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2745 8306 Electronics Tomorrow Ltd. Application For Certification (FCC ID: PEQ735791102) Superheterodyne Receiver 0304794 DL/Sandy May 15, 2003 INTERTEK TESTING SERVICES FCC ID: PEQ735791102 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: PEQ735791102 ii MEASUREMENT/TECHNICAL REPORT Electronics Tomorrow Ltd. - MODEL: 7357 FCC ID: PEQ735791102 This report concerns (check one:)Original Grant X Class II Change ____ Equipment Type: Superheterodyne Receiver (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart B for unintentional radiator - the new 47 CFR [08-20-02 Edition] provision. Report prepared by:Derek Leung Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576, Castle Peak Road, Kowloon, Hong Kong. Phone:852-2173-8504 Fax:852-2371-0521 INTERTEK TESTING SERVICES FCC ID: PEQ735791102 iii Table of Contents 1.0 General Description............................................................................................................2 1.1 Product Description............................................................................................................2 1.2 Related Submittal(s) Grants.................................................................................................2 1.3 Test Methodology...............................................................................................................3 1.4 Test Facility........................................................................................................................3 2.0 System Test Configuration.................................................................................................5 2.1 Justification.........................................................................................................................5 2.2 EUT Exercising Software....................................................................................................5 2.3 Special Accessories............................................................................................................5 2.4 Equipment Modification......................................................................................................6 2.5 Measurement Uncertainty....................................................................................................6 2.6 Support Equipment List and Description..............................................................................6 3.0 Emission Results.................................................................................................................8 3.1 Field Strength Calculation....................................................................................................9 3.2 Radiated Emission Configuration Photograph.....................................................................10 3.3 Radiated Emission Data....................................................................................................11 4.0 Equipment Photographs....................................................................................................14 5.0 Product Labelling..............................................................................................................16 6.0 Technical Specifications....................................................................................................18 7.0 Instruction Manual............................................................................................................20 8.0 Miscellaneous Information...............................................................................................22 8.1 Discussion of Pulse Desensitization....................................................................................23 8.2 Calculation of Average Factor...........................................................................................24 8.3 Emissions Test Procedures................................................................................................25 INTERTEK TESTING SERVICES FCC ID: PEQ735791102 iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated photos.pdf External PhotoExternal Photoexternal photos.pdf Internal PhotoInternal Photointernal photos.pdf Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf INTERTEK TESTING SERVICES FCC ID: PEQ735791102 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: PEQ735791102 2 1.0General Description 1.1Product Description The Equipment Under Test (EUT) is a Receiver Thermometer operating at 433.92MHz. The EUT is powered by 3.0V d.c. (2 x 1.5V βAAβ alkaline batteries). Once batteries are placed in the EUT, it will start receive the temperature signal for 5 minutes from the remote sensor. Upon successful reception, the remote unit temperβ¦
Text truncated - open the document above for the full version.
Test Setup FCCID : PEQ735791102 Radiated -front Radiated - rear
2/F., Garment Centre, Β· Kowloon, Β· Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |

Bluetooth Cooking Thermometer
Equipment Class
DTS - Digital Transmission System
BLE Alarm Clock
Equipment Class
DTS - Digital Transmission System
BLE Vibration Alarm
Equipment Class
DTS - Digital Transmission System
Remote Thermo-Hygrometer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WWVB RC and RF wall clock
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter