Dual Band Outlet
Frequency Range
915.00000000 - 915.00000000
Company
Budderfly INC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Part No R0710021 Description: Installing a Budderfly adapter transforms your building’s existing wiring into the “Budderfly Open Network” and allows the adapter to monitor energy consumption and communicate the data to a facility controller. Budderfly adaptors use the existing power line for communication and thus require no re‐wiring. Using our Budderfly software, you can visualize consumption data and manage each individual adapter. The Budderfly Dual Band Outlet is a component of Budderfly system and designed to work with all other Budderfly devices. It is a plug‐and‐play replacement for your existing Outlet. Once installed, The Budderfly outlets also act as repeaters to extend the range of the network and increase efficiency. Installation: The Budderfly Dual Band Outlet may be used in new installations or to replace an existing Outlet. The wiring schematic will be as per below: 1. At the circuit breaker or fuse panel, disconnect the power for all of the circuits in the switch junction box. 2. Double Check that the power is OFF to the Outlet by trying to turn on a device connected to the plug before continuing. 3. Remove the wall plate from the plug you are replacing. Then, unscrew the outlet itself and pull it out from the junction box. 4. Disconnect the wires from the outlet you are replacing. 5. Follow the Wiring information provided below and connect the wires as follows: ‐ Connect the GROUND wire (usually Bare Copper or Green) to the Ground wire of Budderfly Dual Band Outlet (Yellow & Green). ‐ Connect the LINE wire (usually Black) that comes from the electrical service panel to the HOT wire of Budderfly Dual Band Outlet (Black). ‐ Connect the NEUTRAL wire (usually White) to the Neutral wire of Budderfly Dual Band Outlet (White). 6. After you have connected all of the wires, ensure that all of the wire connectors are firmly attached and that there is no exposed copper except for the GROUND wire. 7. Gently place Budderfly Dual Band Outlet into the junction box. Then, screw the Outlet into place. 8. Reinstall the wall plate 9. Enable power to the Outlet from the circuit breaker or fuse panel 10. Add the device address to the Budderfly software. WARNING: If you are not sure about any part of the above instructions, consult a qualified electrician. WARNING –ELECTRICAL SHOCK HAZARD • The Budderfly Dual Band Outlet is intended for installation in accordance with the National Electric Code and local regulations in the United States. • If you are not knowledgeable or comfortable with electrical circuitry, you should have a qualified electrician install the Budderfly Dual Band Outlet for you. Warning • Install the Budderfly Dual Band Outlets indoor only. • Never use the Budderly Outlets to power medical and/or life support equipment. • The equipment plugged into this Budderfly Dual Band Outlet must not exceed 2400W at 120VAC. WARNING –ELECTRICAL SHOCK HAZARD • Turn OFF the power to the branch circuit for the Outlet at the service panel. • All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the Outlet. Wiring Information • Important: Budderfly Outlet is rated for and intended to only be used with copper wire. • Use 12 AWG or larger wires suitable for 80 o. • Remove 3/4" (1.9 cm) of insulation from each wire. Connect as follows: Twist strands of each end tightly together. Hold bare ends of wires together and push firmly into wire Nut. Screw Nut clockwise making sure that no bare conductor shows below the connector Features: ‐ Ability to create a group of devices ‐ Ability to monitor power consumption ‐ LED indicator to show the state of the Outlet Device Grouping: ‐ Using the Budderfly software, it is possible to create a Group of Outlets. Power consumption: The Budderfly Dual Band Outlets will measure the current, the voltage and the power consumed by the connected load, and will store the minimum, maximum and average data for the past 7 days. The data can be accessed at any time thru the Budderfly software. The user can generate reports, monitor the consumption or check expenses. LED Indicators: The Budderfly Outlets are equipped with 1 bi‐Color LED that will indicate the state of the device. LED is Off: The Budderfly Outlet is not powered. LED is Red: The Budderfly Outlet is On and not member of a group. LED is Green: The Budderfly Outlet is On and is member of a group. Reset: If the device stops responding, it can be restarted by pushing the Reset Button. A non‐metallic pin should be used to push the reset button. None of the stored parameters are affected. Specifications: Power: 120VAC/ 60Hz Maximum Loads: 2400W, 20A (max), 1 HP. Operating Temperature: 10 o C to +40 o C Certification: UL Certification is in progress For indoor use only Specifications subject to change without notice due to continuing product improvement. Communication: The Budderfly Dual Band Outlets use the power line and radio frequency to communicate with the “Facility Controller”. The outlets can reply to the following commands: • Join/Disjoin group “X”: The outlet will Join/Disjoin the group ”X”. Each outlet can be a member of several groups at the same time. • Direct RTC synchronization: The outlet can receive a command to synchronize its “Real Time Clock” • Get Actual Measurement: When the outlet receives a “Get Measurement” command, it will send back to the facility controller a string of data that contains: ‐ The Current in Ampere “A”. ‐ The Power in Watt “W”. ‐ A Timestamp. • Get Stored Measurement: The outlet will send back to the Facility Controller the stored electrical measurements. • Direct Reset Commands: The outlet can receive 3 types of reset commands: ‐ Hard Reset: This command will restart the device without affecting any stored parameter. ‐ Data Reset: This command will erase all the measurement and RTC data stored in the non‐volatile memory. ‐ Group Reset: This command will remove the device from all the joined groups. • Group Reset Commands: The above …

Text truncated - open the document above for the full version.

Attestation Statements

February 06, 2013 CETCB 114 Olinda Drive Brea, CA 92823 Gentlemen: This is a letter of authorization to accept Compatible Electronics, Inc., specifically including the employees of Compatible Electronics, as an Agent for Budderfly LLC (FRN# 0022045272) 2 Trap Falls Road Suite 507, Shelton CT 06484 for a period of one year, to sign applications before the Commission on our behalf, to make representations to you on our behalf, and to receive and exchange data between our company and the Commission in connection with certification of the following Budderfly product: Dual band Switch Dual band plug (double outlets) No Neutral Switch MIWI Plug (double outlets) under FCC Docket Number 20780 and General Docket Number 80-284 pursuant to Part l5 of FCC Rules and Regulations. Please also accept this letter as an attestation that neither Budderfly nor any of its officers, directors, or persons holding 5% or more of the outstanding stock or shares, voting or non-voting, have been denied federal benefits under section 5301 of the Anti-Drug-Abuse act of 1988,21 U.S.C. 853(a). In addition, Budderfly will notify the Federal Communications Commission if, at any time, the situation changes causing Budderfly to be denied federal benefits. If you have any further questions or need additional information, please feel free to give me a call at 714-921-1210. Sincerely, Daniel Riscalla Vice-President Engineering, Budderfly (714)921-1210 Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com

Attestation Statements

February 06, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: TCB application submittal Gentlemen: We, Budderfly, would like to declare that the application being submitted for the Dual Band Outlet with FCC ID: QCVR0710021 has not been submitted to another TCB or FCC for certification. If you have any further questions or need additional information, please feel free to give me a call at 714-921-1210. Sincerely, Daniel Riscalla Vice-President Engineering, Budderfly (714)921-1210 Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com

Attestation Statements

Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com February 07, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: Modifications to the device Gentlemen: This letter is to formally notify you that the following modifications had been completed by Compatible Electronics, Inc. to our (Dual Band Plug R0710021) during FCC certification, and will be implemented in production. Modifications: - The value of the resistor “R7” on the “Insteon PCB” was modified from 1K ohms to 15K ohms. - The length of both Antennas “P1” and “P2” on the “Insteon PCB” was modified from 83 millimeters to 58 millimeters. Sincerely, Daniel Riscalla Vice-President of Engineering

Cover Letter(s)

February 06, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: Request for withholding from public disclosure the schematics, block diagrams, and operational description pursuant to an application for certification Gentlemen: We, Budderfly LLC, would like to request that all schematics, block diagrams, and operational descriptions submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457 (d) of the Commission’s Rules, and Section 552 (b)(4) of the Freedom of Information Act. These sections authorize the withholding from public inspection, those materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any questions, please do not hesitate to contact us at (714)921-1210 or at (203)513-8634. Sincerely, Sincerely, Daniel Riscalla Vice-President of Engineering Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com

Cover Letter(s)

Correspondence by Project Project Number: Correspondence NumberMemo QCVR0710021-1 1) Please provide a new sample label. The sample label incorrectly has the FCC logo which is only allowed for Declaration of Conformity [(JH)] see attached corrected label 2) The user manual mentions that the device is a repeater. Is this device an RF repeater? If so, was the device verified for compliance in this mode of operation as well? [(JH)] (Customer provided) QCVR0710021 uses INSTEON communication protocol, One of INSTEON features is that each message can be repeated for a limited number of times (4 times maximum) We don't have the ability to control this feature, it is always working and thus the devices that were tested were already repeating any message they capture 3) Please confirm compliance to the 15.31(e) requirements. [(JH)] Section 4.1 of the test report. 4) Please describe the type of modulation used in the device. [(JH)] (Customer provided) The RF communication is modulated onto 915 MHz using Frequency-Shift Keying (FSK) 5) Please provide an additional photo showing the entire antenna. [(JH)] section 7.2 of the test report describes the antenna as two 5.8cm long wires soldered to the PCB. If you need photos of the antenna let me know and I can obtain them.

ID Label/Location Info

FOR INDOOR USE ONLYVERSION 5.10 Part No R0710021 Plug Rated: www.budderfly.com U.S.Patent No.8,140,279 Made in China 14 Dec 2012 - 120VAC, 60 Hertz - 20A (max) - 2400Watts Dual Band (APPLIANCE CONTROL) 4NE7 FCC ID: QCVR0710021 12345678 12345678 A B C D E F A B C D E F ANY DISCREPANCIES BETWEEN THE DRAWING AND THE ASSOCIATED MODEL WHEN SUPPLIED TO BE DISCUSSED WITH BNUDDERFLY DENOTES UL QUALITY CHECK U L - 35 1 21 1 15 5 A3 BUDDERFLY 1 OF 1 SHEET NO: THE INFORMATION DISCLOSED IN THIS DOCUMENT IS PROPRIETARY TO BUDDERFLY AND MAY NOT BE USED FOR MANUFACTURE OR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF BUDDERFLY. NA HPGL FILE NAME: NA ALL RIGHTS RESERVED CAD FILE NAME: SWITCH + PLUG LABEL NA DWG NO: NADWG REPL:TITLE: NASURFACE AREA:MASS:NA FREE TOLERANCE NASURFACE FINISH:NA TY868-125MATL DESCP:APVD BY: NATOOL SERNO:MATL NO:CHK BY: DIMENSIONS ARE IN mm INCLUDING FINISH A.Olleik07-Feb-13DWN BY: SCALE:NAMEDATE A.Olleik07-Feb-13NADRAWING RELEASED00ANA DOC NAMEDATESPRTAMENDMENTSIDXZONE LABEL SPECIFICATIONS - MANUFACTURER: FOSHAN SHUNDE TIAN YUE PACKING PRINTING CO LTD - MATERIAL NUMBER: TY868-125 - MAX TEMPERATURE ON POLY CARBONATE (PC): 80C - INDOOR USE ONLY - UL NUMBER: MH25987 - UL CATEGORY: PGDQ2 BUDDERFLY LABEL

Test Report

Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 1 of 17 FCC PART 15, SUBPART B & SUBPART C TEST REPORT For DUAL BAND OUTLET Model: R0710021 Prepared for BUDDERFLY LLC 2 TRAP FALLS RD., SUITE 507 SHELTON, CT 06484 Prepared by: _____________________ JOEY MADLANGBAYAN Approved by: ____________________ JOSH HANSEN COMPATIBLE ELECTRONICS INC. 20621 PASCAL WAY LAKE FOREST, CALIFORNIA 92630 (949) 587-0400 DATE: MARCH 27, 2013 REPORT APPENDICES TOTAL BODY A B C D E PAGES 17 2 2 2 15 18 56 This report shall not be reproduced, except in full, without the written approval of Compatible Electronics. Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 2 of 17 TABLE OF CONTENTS Section / Title PAGE GENERAL REPORT SUMMARY 4 SUMMARY OF TEST RESULTS 4 1. PURPOSE 5 2. ADMINISTRATIVE DATA 6 2.1 Location of Testing 6 2.2 Traceability Statement 6 2.3 Cognizant Personnel 6 2.4 Date Test Sample was Received 6 2.5 Disposition of the Test Sample 6 2.6 Abbreviations and Acronyms 6 3. APPLICABLE DOCUMENTS 7 4. DESCRIPTION OF TEST CONFIGURATION 8 4.1 Description of Test Configuration - EMI 8 4.1.1 Photograph of Test Configuration - EMI 8 4.1.2 Cable Construction and Termination 9 5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 5.1 EUT and Accessory List 10 5.2 EMI Test Equipment 11 6. TEST SITE DESCRIPTION 12 6.1 Test Facility Description 12 6.2 EUT Mounting, Bonding and Grounding 12 7. TEST PROCEDURES 14 7.1 RF Emissions 14 7.1.1 Conducted Emissions Test 14 7.1.2 Radiated Emissions (Spurious and Harmonics) Test 15 7.1.3 Fundamental Field Strength 16 7.1.4 Emissions Radiated Outside of the Fundamental Frequency Band 16 7.1.5 Peak Radiated EMI 16 8. TEST PROCEDURE DEVIATIONS 17 9. CONCLUSIONS 17 Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 3 of 17 LIST OF APPENDICES APPENDIX TITLE A Laboratory Accreditations B Modifications to the EUT C Additional Models Covered Under This Report D Diagrams, Charts and Photos  Test Setup Diagrams  Antenna and Amplifier Gain Factors  Radiated and Conducted Emissions Photos E Data Sheets LIST OF FIGURES FIGURE TITLE 1 Conducted Emissions Test Setup 2 Plot Map And Layout of Test Site below 1 GHz 3 Plot Map & layout of test site Above 1 GHz Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 4 of 17 GENERAL REPORT SUMMARY This electromagnetic emission report is generated by Compatible Electronics Inc., which is an independent testing and consulting firm. The test report is based on testing performed by Compatible Electronics personnel according to the measurement procedures described in the test specifications given below and in the "Test Procedures" section of this report. The measurement data and conclusions appearing herein relate only to the sample tested and this report may not be reproduced in any form except in full, without the written permission of Compatible Electronics. This report must not be used to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. Device Tested: Dual Band Outlet Model: R0710021 S/N: None Product Description: The EUT is an outlet that replaces ordinary outlets and is capable of sensing the current/voltage on the Power Line. This device also supports both power-line and RF communication using the INSTEON Protocol Modifications: The EUT was modified in order to comply with specifications. Please see the list of modifications in Appendix B. Manufacturer: Budderfly LLC 2 Trap Falls Road, Suite 507 Shelton, CT 06484 Test Date: February 08, 2013 Test Specifications: EMI requirements CFR Title 47, Part 15 Subpart B sections 15.107 and 15.109, Subpart C Sections 15.205, 15.207, 15.209 and 15.249 Test Procedures: ANSI C63.4 and ANSI C63.10 SUMMARY OF TEST RESULTS TEST DESCRIPTION RESULTS 1 Conducted RF Emissions, 150 kHz - 30 MHz. Complies with the limits of CFR Title 47 Part 15 Subpart B Section 15.107, Subpart C Section 15.207 2 Radiated RF Emissions & Harmonics, 9 kHz – 10,000 MHz. Complies with the limits of CFR Title 47 Part 15 Subpart B Section 15.109 and Subpart C Section 15.205, 15.209 3 Fundamental Field Strength Complies with CFR Title 47 Part 15 Subpart C Section 15.249(a) 4 Emissions Radiated Outside of the Fundamental Frequency Band Complies with CFR Title 47 Part 15 Subpart C Section 15.249(d) Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 5 of 17 1. PURPOSE This document is a qualification test report based on the Electromagnetic Interference (EMI) tests performed on the Dual Band Outlet Model: R0710021. The EMI measurements were performed according to the measurement procedure described in ANSI C63.10 and ANSI C63.4 . The tests were performed in order to determine whether the electromagnetic emissions from the equipment under test, referred to as EUT (equipment under test) hereafter, are within the specification limits defined by the Code of Federal Regulations Title 47, Part 15 Subpart B 15.107 and 15.109, Subpart C sections 15.205, 15.207, 15.209 and 15.249. The power line carrier emissions tests were not performed by Compatible Electronics. Report Number: D30208R1 FCC ID: QCVR0710021 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476 Page 6 of 17 2. ADMINISTRATIVE DATA 2.1 Location of Testing The EMI tests described herein were performed at the…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chris DeBenedictis(Vice-President of Technology)
[email protected](855) 659-4190Fax: (855) 659-4190

Technical Contact

Compatible Electronics, Inc.Josh B Hansen
[email protected]949-587-0400

20621 Pascal Way · Lake Forest, California · United States

Test Firm

Compatible Electronics, Inc.Michael Christensen
[email protected]714-579-0500Fax: 714-579-1850

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915 MHz - 915 MHz-
Confidentiality
Long Term

Other Applications from Budderfly INC

BUDDERFLY RF DUALBAND OUTLET - FCC ID QCVR1010021 - Budderfly INC
QCVR1010021

BUDDERFLY RF DUALBAND OUTLET

Jan 14, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Budderfly Multi-Way Switch - FCC ID QCVS0811011 - Budderfly INC
QCVS0811011

Budderfly Multi-Way Switch

Dec 23, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
BUDDERFLY RF MULTI-WAY SWITCH - FCC ID QCVS0911011 - Budderfly INC
QCVS0911011

BUDDERFLY RF MULTI-WAY SWITCH

Dec 23, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Controllable Outlet - FCC ID QCVR0610400 - Budderfly INC
QCVR0610400

Controllable Outlet

Sep 29, 2013

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Power Meter - FCC ID QCVM0021501 - Budderfly INC
QCVM0021501

Power Meter

Sep 29, 2013

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified