PartNoS0811011 Description: InstallingaBudderflyadaptertransformsyourbuilding’sexistingwiringintothe“BudderflyOpenNetwork”andallowsthe adaptertomonitorenergyconsumptionandcommunicatethedatatoafacilitycontroller. BudderflyadaptorswillusetheexistingpowerlineandtheRFforcommunicationandthusrequirenoreͲwiring. Usingour Budderflysoftware,youcanvisualizeconsumptiondataandmanageeachindividualadapter. TheBudderflyMultiͲWaylightswitchisacomponentoftheBudderflysystemanddesignedtoworkwithallother Budderflydevices.ItisaplugͲandͲplayreplacementforyourexistinglightswitch.Onceinstalled,theBudderfly switches alsoactasrepeaterstoextendtherangeofthenetworkandincreaseefficiency. Thisdeviceisdesignedforuseonlywithpermanentlyinstalledfixtures. Installation: TheBudderflyMultiͲWaylightswitchmaybeusedinnewinstallationsortoreplaceanexistingwallswitch.Itcouldbeusedeitherasa2Ͳwayswitch,orasa3Ͳwayswitch.Thewiring stepsforbothconfigurationsareexplainedinthefollowingdiagrams: 2ͲWayConfiguration: 3ͲWayConfiguration: 1. Atthecircuitbreakerorfusepanel,disconnectthepowerforallofthecircuitsin theswitchjunctionbox. 2. DoubleCheckthatthepowerisOFFtotheswitchboxbeforecontinuingby tryingtoturnonthecontrolledload. 3. Removethewallplatefromtheswitchyouarereplacing. Then,unscrewthe switchitselfandpullitoutfromthejunctionbox. 4. Disconnectthewiresfromtheswitchyouarereplacing. 5. Followthewiringinformationprovidedbelowtoconnectthewiresasfollows: oConnecttheGROUNDwire(usuallyBareCopperorGreen)totheGroundwire ofBudderflySwitch (Yellow&Green). o2ͲWayconfiguration: ConnecttheLOADwire(usuallyBlack)thatgoestothelighttothe Traveler#1(Red)wireofBudderflySwitch. o3ͲWayconfiguration: ConnecttheTraveler#1(UsuallyRed)andTraveler#2(UsuallyBlue)wires oftheStandardMultiͲWaySwitchtotheTraveler#1 (Red)andTraveler#2 (Blue)wiresofBudderflySwitchrespectively. ConnecttheLOADwire(usuallyBlack)thatgoestothelighttotheLOAD wire(usuallyBlack)oftheStandardMultiͲWaySwitch. oConnecttheLINEwire(usuallyBlack)thatcomesfromtheelectricalservice paneltotheHOTwireof BudderflySwitch(Black). oConnecttheNEUTRALwire(usuallyWhite)totheNeutralwireofBudderfly Switch(White). 6. Afteryouhaveconnectedallofthewires,ensurethatallofthewireconnectors arefirmlyattachedandthatthereisnoexposedcopperexceptfortheGROUND wire. 7. GentlyplaceBudderfly switchintothejunctionbox,orientingtheunitwiththe LEDbarontheleft.Then,screwtheswitchintoplace. 8. Reinstallthewallplate 9. Enablepowertotheswitchfromthecircuitbreakerorfusepanel 10. AfterthePowerLEDcomeson,testthattheswitchisworkingproperly by turningthelightonandoff 11. AddthedeviceaddresstotheBudderflywebapplication. WARNING–ELECTRICALSHOCKHAZARD xTheBudderflyMultiͲWaylightswitchisintendedforinstallationinaccordancewiththeNationalElectricCodeand localregulationsintheUnitedStates. xIfyouarenotknowledgeableorcomfortablewithelectricalcircuitry,youshouldhaveaqualifiedelectricianinstall theBudderflyMultiͲWaylightswitchforyou. Warning RISKOFFIRE/ELECTRICALSHOCK/BURNS ExerciseextremecautionwhenusingBudderflyswitchingdevicestocontrolappliances. ToavoidtheriskofFire,ElectricalShock,Burnsorotherhazardswerecommendthefollowing: xInstalltheBudderflyswitchesindooronly. xNeverusetheBudderflyswitchestocontrolmedicaland/or lifesupportequipment. xDonotusetheBudderflyswitchestocontrolelectricheatersoranyotherapplianceswhichmaypresenta hazardousconditionduetounattendedorunintentionalpoweroncontrol. NeverusetheBudderflyswitcheswithloadsthatexceedthemaximumratingspecified. WiringInformation xImportant:Budderflyswitchesareratedforandintendedtobeusedonlywith copperwires. xUse12AWGorlargerwiressuitablefor80 o. xRemove3/4"(1.9cm)ofinsulationfromeachwire. xConnectasfollows:Twiststrandsofeachendtightlytogether.Holdbareends ofwirestogetherandpushfirmlyintowireNut.ScrewNutclockwisemaking surethatnobareconductorshowsbelowtheconnector. WARNING–ELECTRICALSHOCKHAZARD xTurnOFFthepowertothebranchcircuitfortheswitchandlightingfixtureat theservicepanel. xAllwiringconnectionsmustbemadewiththePOWEROFFtoavoidpersonal injuryand/ordamagetotheswitch. Features: ͲRemoteOn/Offcontrol ͲManualOn/Offcontrol ͲAbilitytocreateagroupofdevices ͲAbilitytomonitorpowerconsumption ͲLEDindicatorstoshowthestateoftheswitch On/OffControl: ͲRemoteControl: oTheBudderflyswitchescanbecontrolledremotelythrutheBudderflysoftware. oTheBudderflysoftwarewillinform youthattheactionwassuccessful.Incasetheaction failed,pleaserepeattheprocedure ͲManualControl:InadditiontotheRemotecontrol,theBudderflyswitchescanbe controlledmanually.Tapthetoporbottomoftherockertogglethestateconnectedload. DeviceGrouping: ͲUsingtheBudderflywebapplication, itispossibletocreateaGroupofdevicesthatcanbe controlledremotelysimultaneouslywithjustoneclick. ͲBudderflyswitchescanjoin/disjoingroupsatanytime. Powerconsumption: Budderflyswitcheswillmeasurethecurrent,voltage,powerandenergyconsumedbythe connectedload,andwillstorethecumulativeenergy consumption. ThedatacanbeaccessedatanytimethrutheBudderflysoftware.Theusercangenerate reports,monitortheconsumptionorcheckexpenses. LEDIndicators: TheBudd…
Text truncated - open the document above for the full version.
Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com November 29, 2013 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: QCVS0811011 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Schematics - Multi-Way Switch.pdf Block Diagram Block Diagram - Multi-Way Switch.pdf Operational Description Operational Description - Multi-Way Switch.pdf User Manual User Manual - Multi-Way Switch.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. We, Budderfly LLC, would like to request that the above materials submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457 (d) of the Commission’s Rules, and Section552 (b)(4) of the Freedom of Information Act. These sections authorize the withholding from public inspection, those materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any questions, please do not hesitate to contact us at (714)921-1210 or at (203)513-8634. Sincerely, Daniel Riscalla Vice-President of Engineering (714)921-1210
Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com November 29, 2013 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: POWER OF ATTORNEY, FCC ID: QCVS0811011 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Nov 29, 2014. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Budderfly LLC, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Daniel Riscalla Vice-President of Engineering (714)921-1210
Reference No. WTS13S1109471E Page 21 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 12 Photographs - Constructional Details 12.1 EUT - Appearance View Reference No. WTS13S1109471E Page 22 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No. WTS13S1109471E Page 23 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn
FCC Label Location for model: S0811011 The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Budderfly LLC Model No.: S0811011 FCC ID: QCVS0811011 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Label FCC Label Sample for model: S0 811011 FCC ID: QCV S0811011 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Reference No. WTS13S1109471E Page 23 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No. WTS13S1109471E Page 24 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 12.2 EUT - Open View Reference No. WTS13S1109471E Page 25 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No. WTS13S1109471E Page 26 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn ==End of Test Report== ANT
TEST REPORT Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Page 1 of 26 Reference No. .................... : WTS13S1109471E FCC ID ................................ : QCVS0811011 Applicant ............................ : Budderfly LLC Address .............................. : 2 Trap Falls Road, Suite 507 Shelton, CT 06484 USA Manufacturer .................... : CME Electronics Technology Co., LTD Address .............................. : Suite B, 18th Floor, Jingwangem No. 303, Qinglv Road South, Gongbei, Zhuhai 519020,Guangdong Province, China Product Name .................... : Budderfly Multi-Way Switch Model No. ........................... : S0811011 Standards ........................... : FCC CFR47 Part 15 Section 15.249: 2012 Date of Receipt sample .... : Dec.01,2013 Date of Test ........................ : Dec.02~06,2013 Date of Issue ...................... : Dec.23,2013 Test Result ......................... : Pass * *Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Testing location: The same as above Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Tiger Ye / Project Engineer Philo Zhong / Manager Reference No. WTS13S1109471E Page 2 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Test Summary Test Items Test Requirement Result Outside of Band Emission 15.249 15.205 15.209 PASS 20dB Bandwidth 15:215(c) PASS Conducted Emissions 15.207 PASS Radiated Emission 15.249(a) 15.209 15.205(a) PASS Antenna Requirement 15.203 PASS Reference No. WTS13S1109471E Page 3 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY .................................................................................................................................................... 2 3 CONTENTS .............................................................................................................................................................. 3 4 GENERAL INFORMATION ................................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T. ............................................................................................................. 4 4.2 DETAILS OF E.U.T........................................................................................................................................ 4 4.3 TEST FACILITY .............................................................................................................................................. 4 4.4 TEST LOCATION ............................................................................................................................................ 4 4.5 GENERAL CONDITION ................................................................................................................................... 5 4.5.1 Test Mode ................................................................................................................................................... 5 5 EQUIPMENT USED DURING TEST .................................................................................................................... 6 5.1 EQUIPMENTS LIST ........................................................................................................................................ 6 5.2 MEASUREMENT UNCERTAINTY .................................................................................................................... 6 5.3 TEST EQUIPMENT CALIBRATION .................................................................................................................. 6 6 CONDUCTED EMISSION TEST ........................................................................................................................... 7 6.1 E.U.T. TEST CONDITION .............................................................................................................................. 7 6.2 EUT SETUP .................................................................................................................................................. 7 6.3 CONDUCTED EMISSION TEST RESULT ......................................................................................................... 8 7 RADIATION EMISSION TEST ............................................................................................................................ 10 7.1 EUT OPERATION: ...................................................................................................................................... 10 7.2 TEST SETUP ............................................................................................................................................... 11 7.3 SPECTRUM ANALYZER SETUP ................................................................................................................... 12 7.4 TEST PROCEDURE ..................................................................................................................................... 13 7.5 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................. 13 7.6 RADIATED EMISSIONS TEST RESULT ......................................................................................................... 13 7.7 RADIATED EMISSION DATA .........................................................................…
Text truncated - open the document above for the full version.
Reference No. WTS13S1109471E Page 19 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 11 Photographs of Testing 11.1 Conducted Emissions Test View 11.2 Radiation Emission From 30MHz-1GHz Reference No. WTS13S1109471E Page 20 of 26 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 11.3 Radiation Emission From 30MHz-1GHz 11.4 Radiation Emission Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915 MHz - 915 MHz | 1.00 mW |

BUDDERFLY RF DUALBAND OUTLET
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BUDDERFLY RF MULTI-WAY SWITCH
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Controllable Outlet
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Power Meter
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Power Pack
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified