Part No S0311010 Description: Installing a Budderfly adapter transforms your building’s existing wiring into the “Budderfly Open Network” and allows the adapter to monitor energy consumption and communicate the data to a facility controller. The Budderfly RF switch presents a battery powered solution to replace installed switches that lack the presence of a neutral , for operation it will use the RF to communicate with the installed the plug and play Budderfly RF outlet that uses the power line communication and thus require no re-wiring. The RF switch requires to be installed within a range of 15 meters of Budderfly RF outlet. The Budderfly RF switch is designed with battery saving features to prolong the battery life. The Budderfly lighting RF switch is a component of the Budderfly system and designed to work with all other Budderfly devices. It is a plug-and-play replacement for your existing lighting switch. NOTE: For remote control applications using the Budderfly software, the Budderfly RF switch needs to installed in a range of 15 meter of a Budderfly RF outlet This device is designed for use only with permanently installed fixtures. WARNING –ELECTRICAL SHOCK HAZARD The Budderfly RF Light Switch is intended for installation in accordance with the National Electric Code and local regulations in the United States. If you are not knowledgeable or comfortable with electrical circuitry, you should have a qualified electrician to install the Budderfly Switch for you. Installation: The Budderfly switch may be used in new installations or to replace an existing wall switch. It is intended to be used only as a 2- way switch. The wiring schematic will be as per below: Warning RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS Exercise extreme caution when using Budderfly switching devices to control appliances. To avoid the risk of Fire, Electrical Shock, Burns or other hazards we recommend the following: Install the Budderfly switches indoor only. Never use the Budderfly switches to control medical and/or life support equipment. Do not use the Budderfly switches to control electric heaters or any other appliances which may present a hazardous condition due to unattended or unintentional power on control. Never use the Budderfly switches with loads that exceed the maximum rating specified. WARNING –ELECTRICAL SHOCK HAZARD Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the switch. 1. Before installing the Budderfly RF switch make sure that a Budderfly RF plug will be installed within range 15 meter. 2. At the circuit breaker or fuse panel, disconnect the power for all of the circuits in the switch junction box. 3. Double Check that the power is OFF to the switch box before continuing by trying to turn on the controlled load. 4. Remove the wall plate from the switch you are replacing. Then, unscrew the switch itself and pull it out from the junction box. 5. Disconnect the wires from the switch you are replacing. 6. Follow the Wiring information provided below to connect the wires as follows: o Connect the GROUND wire (usually Bare Copper or Green) to the Ground wire of Budderfly Switch (Yellow & Green). o Connect the LOAD wire (usually Black) that goes to the light to the LOAD wire of Budderfly Switch (Red). o Connect the LINE wire (usually Black) that comes from the electrical service panel to the HOT wire of Budderfly Switch (Black). 7. After you have connected all of the wires, ensure that all of the wire connectors are firmly attached and that there is no exposed copper except for the GROUND wire. 8. Gently place Budderfly switch into the junction box, orienting the unit with the LED bar on the left. Then, screw the switch into place. 9. Place the batteries in the battery compartment and close it: a. Remove the rocker b. Insert the batteries as shown in the picture c. Put the rocker back on 10. Reinstall the wall plate 11. Enable power to the switch from the circuit breaker or fuse panel 12. After the Enabling the power wait for 1 min, the Statues LED will turn ON for 10 seconds then is turned OFF indicating that a connection with RF plug was established 13. Add the device address to the Budderfly web application. “Power Cut-Off” mode: - The Budderfly switches have the ability to completely disconnect the power from the load. - Pressing the top of the rocker for 15 seconds will activate the “Power Cut-off” feature; the load will be turned off. - The Status LED will start blinking to indicate that the load is disconnected and the switch is in the Power Cut-off mode. - When the “Power Cut-off” mode is activated, the switch cannot be turned on through software and cannot be turned on physically. - Pressing the Bottom of the rocker again for 15 seconds will de-activate the “Power Cut-off” mode, and the device will go back to the normal state. Wiring Information Important: Budderfly Switch is rated for and intended to only be used with copper wire. Use 12 AWG or larger wires suitable for 80 o. Remove 3/4" (1.9 cm) of insulation from each wire. Connect as follows: Twist strands of each end tightly together. Hold bare ends of wires together and push firmly into wire Nut. Screw Nut clockwise making sure that no bare conductor shows below the connector. WARNING –ELECTRICAL SHOCK HAZARD When replacing the Bulbs, make sure to enable the “Power Cut-off” mode. If the power LED does not start blinking, please consult a qualified electrician. WARNING: If you are not sure about any part of the above instructions, consult a qualified electrician. Features: - Remote On/Off control - Manual On/Off control - No neutral required On/Off Control: - Remote Control: o The Budderfly switches can be controlled remotely thru the Budderfly software. o The Budderfly software will inform you that the action was successful. In case the action failed…
Text truncated - open the document above for the full version.
February 06, 2013 CETCB 114 Olinda Drive Brea, CA 92823 Gentlemen: This is a letter of authorization to accept Compatible Electronics, Inc., specifically including the employees of Compatible Electronics, as an Agent for Budderfly LLC (FRN# 0022045272) 2 Trap Falls Road Suite 507, Shelton CT 06484 for a period of one year, to sign applications before the Commission on our behalf, to make representations to you on our behalf, and to receive and exchange data between our company and the Commission in connection with certification of the following Budderfly product: Dual band Switch Dual band plug (double outlets) No Neutral Switch MIWI Plug (double outlets) under FCC Docket Number 20780 and General Docket Number 80-284 pursuant to Part l5 of FCC Rules and Regulations. Please also accept this letter as an attestation that neither Budderfly nor any of its officers, directors, or persons holding 5% or more of the outstanding stock or shares, voting or non-voting, have been denied federal benefits under section 5301 of the Anti-Drug-Abuse act of 1988,21 U.S.C. 853(a). In addition, Budderfly will notify the Federal Communications Commission if, at any time, the situation changes causing Budderfly to be denied federal benefits. If you have any further questions or need additional information, please feel free to give me a call at 714-921-1210. Sincerely, Daniel Riscalla Vice-President Engineering, Budderfly (714)921-1210 Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com
February 06, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: TCB application submittal Gentlemen: We, Budderfly, would like to declare that the application being submitted for the No Neutral RF switch with FCC ID: QCVS0311010 has not been submitted to another TCB or FCC for certification. If you have any further questions or need additional information, please feel free to give me a call at 714-921-1210. Sincerely, Daniel Riscalla Vice-President Engineering, Budderfly (714)921-1210 Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com
Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com July 19, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: Modifications to the device Gentlemen: This letter is to formally notify you that the following modifications had been completed by Compatible Electronics, Inc. to our (RF Switch S0311010) during FCC certification, and will be implemented in production. Modifications: - The transmit power was set to 4dBm. Sincerely, Daniel Riscalla Vice-President Engineering, Budderfly (714)921-1210
February 06, 2013 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: Request for withholding from public disclosure the schematics, block diagrams, and operational description pursuant to an application for certification Gentlemen: We, Budderfly LLC, would like to request that all schematics, block diagrams, and operational descriptions submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457 (d) of the Commission’s Rules, and Section 552 (b)(4) of the Freedom of Information Act. These sections authorize the withholding from public inspection, those materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any questions, please do not hesitate to contact us at (714)921-1210 or at (203)513-8634. Sincerely, Sincerely, Daniel Riscalla Vice-President of Engineering Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 203-513-8634 www.Budderfly.com
Correspondence by Project Project Number: Correspondence NumberMemo QCVS0311010-1 1) Please provide an updated block diagram. The block diagram provided does not give all the frequencies used in the device. A: Updated Block Diagram uploaded 2) Please provide updated schematics. The schematics provided do not show the location of the antenna. A: Updated Schematics uploaded 3) Please provide an updated operational description. The operational description does not provide details regarding the type of modulation used. A: Updated Operational Description uploaded 4) Please provide additional external pictures showing all sides of the device. A: Updated External Photos uploaded 5) Please provide additional internal photos. The internal photos do not show the location of the antenna, batteries and battery compartment. A: Updated Internal Photos uploaded Untitled Documenthttp://www.celectronics.com/CorrespondenceByProject.asp?ProjectNum... 1 of 17/18/2013 5:07 PM
FOR INDOOR USE ONLYVERSION 1.30 Part No S0311010 RF Switch Rated: www.budderfly.com U.S.Patent No.8,140,279 Made in China 14 Dec 2012 - 120V, 60 Hertz: 1600W for Tungsten. 1400W for electronic ballast. 800W for standard ballast - 277V, 60 Hertz: 3300W for electronic ballast - 1200W for standard ballast. (APPLIANCE CONTROL) 4NE7 FCC ID: QCVS0311010
12345678 12345678 A B C D E F A B C D E F ANY DISCREPANCIES BETWEEN THE DRAWING AND THE ASSOCIATED MODEL WHEN SUPPLIED TO BE DISCUSSED WITH BNUDDERFLY DENOTES UL QUALITY CHECK U L - 35 1 21 1 15 5 A3 BUDDERFLY 1 OF 1 SHEET NO: THE INFORMATION DISCLOSED IN THIS DOCUMENT IS PROPRIETARY TO BUDDERFLY AND MAY NOT BE USED FOR MANUFACTURE OR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF BUDDERFLY. NA HPGL FILE NAME: NA ALL RIGHTS RESERVED CAD FILE NAME: SWITCH + PLUG LABEL NA DWG NO: NADWG REPL:TITLE: NASURFACE AREA:MASS:NA FREE TOLERANCE NASURFACE FINISH:NA TY868-125MATL DESCP:APVD BY: NATOOL SERNO:MATL NO:CHK BY: DIMENSIONS ARE IN mm INCLUDING FINISH A.Olleik07-Feb-13DWN BY: SCALE:NAMEDATE A.Olleik07-Feb-13NADRAWING RELEASED00ANA DOC NAMEDATESPRTAMENDMENTSIDXZONE LABEL SPECIFICATIONS - MANUFACTURER: FOSHAN SHUNDE TIAN YUE PACKING PRINTING CO LTD - MATERIAL NUMBER: TY868-125 - MAX TEMPERATURE ON POLY CARBONATE (PC): 80C - INDOOR USE ONLY - UL NUMBER: MH25987 - UL CATEGORY: PGDQ2 BUDDERFLY LABEL
Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 1 of 17 FCC PART 15, SUBPART B & SUBPART C TEST REPORT For RF SWITCH Model: S0311010 Prepared for BUDDERFLY LLC 2 TRAP FALLS RD., SUITE 507 SHELTON, CT 06484 Prepared by:_____________________ JOEY MADLANGBAYAN Approved by:____________________ JOSH HANSEN COMPATIBLE ELECTRONICS INC. 20621 PASCAL WAY LAKE FOREST, CALIFORNIA 92630 (949) 587-0400 DATE: MAY 8, 2013 REPORT APPENDICES TOTAL BODY A B C D E PAGES 17 2 2 2 12 18 53 This report shall not be reproduced, except in full, without the written approval of Compatible Electronics. Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 2 of 17 TABLE OF CONTENTS Section / Title PAGE GENERAL REPORT SUMMARY 4 SUMMARY OF TEST RESULTS 5 1. PURPOSE 5 2. ADMINISTRATIVE DATA 6 2.1 Location of Testing 6 2.2 Traceability Statement 6 2.3 Cognizant Personnel 6 2.4 Date Test Sample was Received 6 2.5 Disposition of the Test Sample 6 2.6 Abbreviations and Acronyms 6 3. APPLICABLE DOCUMENTS 7 4. DESCRIPTION OF TEST CONFIGURATION 8 4.1 Description of Test Configuration - EMI 8 4.1.1 Photograph of Test Configuration - EMI 8 4.1.2 Cable Construction and Termination 9 5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 5.1 EUT and Accessory List 10 5.2 EMI Test Equipment 11 6. TEST SITE DESCRIPTION 12 6.1 Test Facility Description 12 6.2 EUT Mounting, Bonding and Grounding 12 7. CHARACTERISTICS OF THE TRANSMITTER 13 7.1 Channel Number and Frequencies 13 7.2 Antenna 13 8. TEST PROCEDURES 14 8.1 RF Emissions 14 8.1.1 Conducted Emissions Test 14 8.1.2 Radiated Emissions (Spurious and Harmonics) Test 15 8.1.3 Fundamental Field Strength 16 8.1.4 Emissions Radiated Outside of the Fundamental Frequency Band 16 8.1.5 Peak Radiated EMI 16 8. TEST PROCEDURE DEVIATIONS 17 9. CONCLUSIONS 17 Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 3 of 17 LIST OF APPENDICES APPENDIX TITLE A Laboratory Accreditations B Modifications to the EUT C Additional Models Covered Under This Report D Diagrams, Charts and Photos Test Setup Diagrams Antenna and Amplifier Gain Factors Radiated and Conducted Emissions Photos E Data Sheets LIST OF FIGURES FIGURE TITLE 1 Conducted Emissions Test Setup 2 Plot Map And Layout of Test Site Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 4 of 17 GENERAL REPORT SUMMARY This electromagnetic emission report is generated by Compatible Electronics Inc., which is an independent testing and consulting firm. The test report is based on testing performed by Compatible Electronics personnel according to the measurement procedures described in the test specifications given below and in the "Test Procedures" section of this report. The measurement data and conclusions appearing herein relate only to the sample tested and this report may not be reproduced in any form except in full, without the written permission of Compatible Electronics. This report must not be used to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. Device Tested: RF Switch Model: S0311010 S/N: None Product Description: The EUT is a Switch that replaces ordinary light switches and is capable of communicating with a Budderfly RF Outlet in proximity using the MiWi RF Protocol. Modifications: The EUT was modified in order to comply with specifications. Please see the list of modifications in Appendix B. Manufacturer: Budderfly LLC 2 Trap Falls Rd., Suite 507 Shelton, CT 06484 Test Date: February 15, 2013 Test Specifications: EMI requirements CFR Title 47, Part 15 Subpart B section 15.107 and 15.109 CFR Title 47, Part 15 Subpart C Sections 15.205, 15.207, 15.209 and 15.249 Test Procedure: ANSI C63.4 and ANSI 63.10. Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 5 of 17 SUMMARY OF TEST RESULTS TEST DESCRIPTION RESULTS 1 Conducted RF Emissions, 150 kHz - 30 MHz. The EUT is a battery power device; therefore this test was not performed. 2 Radiated RF Emissions & Harmonics, 9 kHz – 10,000 MHz. Complies with the limits of CFR Title 47 Part 15 subpart B section 15.109 and subpart C Section 15.205, 15.209 and 15.249. 3 Fundamental Field Strength Complies with CFR Title 47 Part 15 Subpart C Section 15.249(a). 4 Emissions Radiated Outside of the Fundamental Frequency Band Complies with CFR Title 47 Part 15 Subpart C Section 15.249(d) and 15.205. 1. PURPOSE This document is a qualification test report based on the Electromagnetic Interference (EMI) tests performed on the RF Switch Model: S0311010. The EMI measurements were performed according to the measurement procedure described in ANSI C63.4 and C63.10. The tests were performed in order to determine whether the electromagnetic emissions from the equipment under test, referred to as EUT (equipment under test) hereafter, are within the specification limits defined by the Code of Federal Regulations Title 47, Part 15 Subpart B section 15.109, Subpart C sections 15.205, 15.209 and 15.249. Report Number: D30214R1 FCC ID: QCVS0311010 FCC Part 15 Subpart C Section 15.249 Test Report 20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630 PH: (949) 587-0400 FX: (949) 587-0476 Page 6 of 17 2. ADMINISTRATIVE DATA 2.1 Location of Testing The EMI tests described herein were performed at the test facility of Compatible Electronics 20621 Pascal Way Lake Forest, California 92630. 2.2 Traceability Statement The cal…
Text truncated - open the document above for the full version.
SAR TEST EXCLUSION This device, FCC ID: QCVS0311010, is excluded from SAR testing by the following justification. The power level setting of the transmitter is 2.5 mW. By using the following formula from section 4.3.1 of KDB 447498: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]*[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR and using the minimum test separation distance of 5 mm, the resulting calculated SAR value is: (2.5 mW)/5 mm) * (√.92135 GHz) = 0.48 This value is below the exclusion threshold for both the 1-g SAR and 10-g extremity SAR requirements.
20621 Pascal Way · Lake Forest, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915.38 MHz - 921.35 MHz | - |

BUDDERFLY RF DUALBAND OUTLET
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Budderfly Multi-Way Switch
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BUDDERFLY RF MULTI-WAY SWITCH
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Controllable Outlet
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Power Meter
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified