
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Wonderful Communication, Mobile Life. Thank you for choosing B160 Fixed Wireless Terminal. B160 Fixed Wireless Terminal User Guide Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. The product described in this manual may include copyrighted software of Huawei Technologies Co., Ltd and possible licensors. Customers shall not in any manner reproduce, distribute, modify, decompile, disassemble, decrypt, extract, reverse engineer, lease, assign, or sublicense the said software, unless such restrictions are prohibited by applicable laws or such actions are approved by respective copyright holders under licenses. Trademarks and Permissions , HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned are the property of their respective owners. Notice Some features of the product and its accessories described herein rely on the software installed, capacities and settings of local network, and may not be activated or may be limited by local network operators or network service providers, thus the descriptions herein may not exactly match the product or its accessories you purchase. Huawei Technologies Co., Ltd reserves the right to change or modify any information or specifications contained in this manual without prior notice or obligation. NO WARRANTY THE CONTENTS OF THIS MANUAL ARE PROVIDED “AS IS”. EXCEPT AS REQUIRED BY APPLICABLE LAWS, NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY OR CONTENTS OF THIS MANUAL. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO CASE SHALL HUAWEI TECHNOLOGIES CO., LTD BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, OR LOST PROFITS, BUSINESS, REVENUE, DATA, GOODWILL OR ANTICIPATED SAVINGS. Import and Export Regulations Customers shall comply with all applicable export or import laws and regulations and will obtain all necessary governmental permits and licenses in order to export, re-export or import the product mentioned in this manual including the software and technical data therein. i Table of Contents 1 Introduction ....................................................................................................................... 1 Appearance ................................................................................................................ 1 Installation ................................................................................................................. 3 Text Input ................................................................................................................... 6 2 Basic Operations ................................................................................................................ 7 Using the Menu .......................................................................................................... 7 Making or Answering Calls ........................................................................................ 7 3 Contacts ............................................................................................................................. 8 Making Calls from Contacts ....................................................................................... 8 Searching for a Contact .............................................................................................. 8 Groups ........................................................................................................................ 8 4 Messages ......................................................................................................................... 10 Creating a Text Message .......................................................................................... 10 Viewing a Text Message ........................................................................................... 10 Message Settings ...................................................................................................... 11 Delete All ................................................................................................................. 11 5 Call log ............................................................................................................................ 12 Viewing the Call Records ......................................................................................... 12 Other Operations ...................................................................................................... 12 6 Tools ................................................................................................................................ 13 Alarms ...................................................................................................................... 13 Calendar ................................................................................................................... 13 Calculator ................................................................................................................. 13 World Time .............................................................................................................. 13 7 Profiles ............................................................................................................................ 14 Selecting a Profile .................................................................................................... 14 Editing a Profile ....................................................................................................... 14 8 Settings ........................................................................................................................…
Text truncated - open the document above for the full version.
Huawei Technologies Co., Ltd. Address:Huawei Industrial Base, Bantian, Longgang, Shenzhen, P.R China Post ZIP:518129 Page :1/1 To: Jiangsu TÜV Product Service Ltd. – Shenzhen Branch Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Authorization 2011-02-28 FCC ID:QISB160 To whom it may concern: We the undersigned, hereby authorize Louis Lin of Jiangsu TÜV Product Service Ltd. – Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Louis Lin of Jiangsu TÜV Product Service Ltd. – Shenzhen Branch on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from Huawei Technologies Co., Ltd. . Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager
Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518129, P.R China Post ZIP:518129 Page :1/1 To: TUVPS Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISB160 to be kept confidential: 1. Schematic diagram. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Turn-up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager
Huawei B160 Fixed Wireless Terminal SECRET Page1, Total4 Photo documentation of external of product Huawei B160 Fixed Wireless Terminal SECRET Page2, Total4 Huawei B160 Fixed Wireless Terminal SECRET Page3, Total4 Huawei B160 Fixed Wireless Terminal SECRET Page4, Total4
Huawei B160 Fixed Wireless Terminal SECRET Page1, Total 1 B160 Label:
Huawei B160 Fixed Wireless Terminal SECRET Page1, Total 1 B160 Label Location
Huawei B160 Fixed Wireless Terminal SECRET Page1, Total8 Photo documentation of interior of product Huawei B160 Fixed Wireless Terminal SECRET Page2, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page3, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page4, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page5, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page6, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page7, Total8 Huawei B160 Fixed Wireless Terminal SECRET Page8, Total8
HUAWEI B160 Electromagnetic Radiation Exposure Estimation 1 Maximum Permissible Exposure (MPE) Estimation for B160 1 Introduction HUAWEI B160 is Wireless Module equipments in the GSM/GRPS/WCDMA system, for B160, the frequency band is GSM850 PCS1900 and WCDMA850M. The Wireless Module implement such functions as RF signal receiving / Transmitting, GSM/GRPS/WCDMA protocol processing, SMS service etc. 2 Limits and Guidelines on Exposure to Electromagnetic Fields According to the FCC Part 2.1091, we know: mobile device (transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitters radiating structure(s) and the body of the user or nearby persons). And the Cellular radiotelephone service and PCS services are subject to routine environmental evaluation for RF exposure prior to equipment authorization or use if they operate at frequencies of 1.5 GHz or below and their effective radiated power (ERP) is 1.5 watts or more, or if they operate at frequencies above 1.5 GHz and their ERP is 3 watts or more. The radiated power of 850MHz for B160 is 1W, so the B160 are excluded from routine environmental evaluation for RF exposure according to the requirement of FCC Part 2.1091. The present document is given just only for reference. Uncontrolled limits are used for general public. General population/uncontrolled exposure apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure. The exposure levels can be expressed in terms of power density, electric field strength, or magnetic field strength, as averaged over 30 minutes for the general public and 6 minutes for trained personnel. The exposure criterion is frequency dependent, and a chart covering the range from 3 kHz to 100 GHz can be found in NCRP No.86 (references IEEE C95.1-1999). Below are the limits. Limits for Occupational/Controlled Exposure HUAWEI B160 Electromagnetic Radiation Exposure Estimation 2 Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm2) 0.3-3.0 3.0-30 30-300 300-1500 15,00-100,000 614 1842/f 61.4 -- -- 16.3/f 16.3/f 0.163 -- -- (100)* (900/f2)* 1.0 f/300 5 Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm2) 0.3-1.34 1.34-30 30-300 300-15,00 15,00-100,000 614 824/f 27.5 -- -- 1.63 2.19/f 0.073 -- -- (100)* (180/f2)* 0.2 f/1500 1.0 For mostly safe in the extreme condition, we take the lowest frequency to calculate, here, the lowest TX frequency of US cellular (824MHz) is taken. Power density S [mW/cm2] for controlled area at 824 MHz 75.2 300 248 300 )( MHzf S mW/cm 2 Power density S [mW/cm2] for uncontrolled area at 824 MHz 55.0 1500 248 1500 )( MHzf S mW/cm 2 S= 0.55 mW/cm 2 = 5.5 W/m 2 for uncontrolled exposure Power density S [mW/cm2] for uncontrolled area at 1900/2400 MHz S=1 mW/cm 2 Reference levels are provided for exposure assessment to determine whether the basic restrictions on exposure of humans to electromagnetic fields are exceeded. The basic restrictions on exposure to electromagnetic fields are based directly on established health effects and biological considerations. HUAWEI B160 Electromagnetic Radiation Exposure Estimation 3 3 Location of EUT The EUT uses one monopole antenna. The source of the radiation is mounted on terminal; generally the direction of the antenna position is uprightness tabletop. The highest level of emission would be expected in close vicinity of the antenna and in line of sight to the antenna. 4 Prediction of the Exposure to Electromagnetic Fields Calculations can be made on a site by site basis to ensure the power density is below the limits given above, or guidelines can be done beforehand to ensure the minimum distances from the antenna is maintained through the site planning. The calculations are based on FCC OET 65 Appendix B. 4.1 Calculation of the Safe Distance Below method describes a theoretical approach to calculate possible exposure to electromagnetic radiation around a base station transceiver antenna. Precise statements are basically only possible either with measurements or complex calculations considering the complexity of the environment (e.g. soil conditions, near buildings and other obstacles) which causes reflections, scattering of electromagnetic fields. The maximum output power (given in EIRP) of a base station is usually limited by license conditions of the network operator. A rough estimation of the expected exposure in power flux density on a given point can be made with the following equation. The calculations are based on FCC OET 65 Appendix B. )(4 )( 2 mr GWP S numeric Whereas: P = Maximum output power in W of the site G numeric = Numeric gain of the antenna relative to isotropic antenna R = distance between the antenna and the point of exposure in meters 4.2 Technical Description B160 Technical Specification: HUAWEI B160 Electromagnetic Radiation Exposure Estimation 4 Cellular Band ERP: 32.78dBm for GSM850MHz 23.49dBm for WCDMA850MHz Transmitter frequency band GSM850 WCDMA850 Frequency range: 850M: Uplink:824 M~849M; Downlink:869 M~894M 850M: Uplink:824 M~849M; Downlink:869 M~894M PCS Band EIRP: 28.90 dBm for GSM1900MHz Transmitter frequency band GSM1900 Frequency range: 1900M: Uplink:1850 M~1910M; Downlink:1930M~1990M 4.3 Estimation of compliance boundary for indoor antenna 1) Cellular Band: GSM850 For the final determination of the compliance boundary the model for far-field calculation is used since this overestimates the field strength in the near-field region. Thus the calculated compliance boundary should be rather more conservative and on the s…
Text truncated - open the document above for the full version.
FCC RF Test Report Product Name: Fixed Wireless Terminal Model Number: B160 Report No: SYBH(Z-RF)007032011-2001 FCC ID: QISB160 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total35 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 4. The test report is invalid if not marked with "exclusive stamp for the test report". 5. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 8. Normally, the test report is only responsible for the samples that have undergone the test. 9. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total35 Notice 2 Modification Information: Modification Information Modification Information 1 2 3 4 5 6 7 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total35 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22 : Subpart H; START OF TEST Feb.26, 2011 END OF TEST Feb.28, 2011 Final Judgement: Pass Approved By Mar.07, 2011 Chenxiaohong Date Name Signature Reviewed By Mar.07, 2011 Xuguangyi Date Name Signature Operator Mar.07, 2011 luxiaoguang Date Name Signature FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total35 Contents 1 Summary .....................................................................................................................................................6 2 Product Description ...................................................................................................................................7 2.1 PRODUCTION INFORMATION ....................................................................................................................7 2.2 MODIFICATION INFORMATION ..................................................................................................................7 3 Test Site Description ..................................................................................................................................8 3.1 TESTING PERIOD ....................................................................................................................................8 3.2 GENERAL SET UP DESCRIPTION ..............................................................................................................8 4 Product Description ...................................................................................................................................9 4.1 TECHNICAL CHARACTERISTICS ................................................................................................................9 4.2 EUT IDENTIFICATION LIST .....................................................................................................................11 5 Main Test Instruments .............................................................................................................................12 6 Transmitter Measurements .....................................................................................................................13 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP) .........................................................................13 6.2 CONDUCTED POWER OF TRANSMITTER .................................................................................................17 6.3 MODULATION CHARACTERISTICS ...........................................................................................................20 6.4 OCCUPIED BANDWIDTH .........................................................................................................................22 6.5 BAND EDGES COMPLIANCE ...................................................................................................................25 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL .........................................................................................27 6.7 FREQUENCY STABILITY .........................................................................................................................30 7 System Measurement Uncertainty ..........................................................................................................34 8 Appendices ...............................................................................................................................................35 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page6, Total35 1 Summary The table below summarizes the measurements and results for the Fixed Wireless Terminal. Det…
Text truncated - open the document above for the full version.
FCC RF Test Report Product Name: Fixed Wireless Terminal Model Number:B160 Report No: SYBH(Z-RF)007032011-2002 FCC ID: QISB160 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total35 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 4. The test report is invalid if not marked with "exclusive stamp for the test report". 5. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 8. Normally, the test report is only responsible for the samples that have undergone the test. 9. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total35 Notice 2 Modification Information: Modification Information Modification Information 1 2 3 4 5 6 7 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total35 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 24: Subpart E; START OF TEST Feb.26, 2011 END OF TEST Feb.28, 2011 Final Judgement: Pass Approved By Mar.07, 2011 Chenxiaohong Date Name Signature Reviewed By Mar.07, 2011 Xuguangyi Date Name Signature Operator Mar.07, 2011 luxiaoguang Date Name Signature FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total35 Contents 1 Summary .....................................................................................................................................................6 2 Product Description .................................................................................................................................7 2.1 PRODUCTION INFORMATION ....................................................................................................................7 2.2 MODIFICATION INFORMATION ..................................................................................................................7 3 Test Site Description ..................................................................................................................................8 3.1 TESTING PERIOD ....................................................................................................................................8 3.2 GENERAL SET UP DESCRIPTION ..............................................................................................................8 4 Product Description ...................................................................................................................................9 4.1 TECHNICAL CHARACTERISTICS ................................................................................................................9 4.2 EUT IDENTIFICATION LIST .....................................................................................................................11 5 Main Test Instruments .............................................................................................................................12 6 Transmitter Measurements .....................................................................................................................13 6.1 EFFECTIVE ISOTROPIC RADIATED POWER OF TRANSMITTER (EIRP) ........................................................13 6.2 CONDUCTED POWER OF TRANSMITTER .................................................................................................17 6.3 MODULATION CHARACTERISTICS ...........................................................................................................20 6.4 OCCUPIED BANDWIDTH .........................................................................................................................22 6.5 BAND EDGES COMPLIANCE ...................................................................................................................25 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL .........................................................................................27 6.7 FREQUENCY STABILITY .........................................................................................................................30 7 System Measurement Uncertainty ..........................................................................................................34 8 Appendices ...............................................................................................................................................35 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-RF)007032011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page6, Total35 1 Summary The table below summarizes the measurements and results for the Fixed Wireless Terminal. Detailed resu…
Text truncated - open the document above for the full version.
Report No: SYBH(Z-EMC)005032011 -2 Confidential Information of Huawei. No Distribution without Written Permission Page1, Total17 EMC Test Report Product Name: Fixed Wireless Terminal Model Number: B160 Report No: SYBH(Z-EMC)005032011-2 FCC ID: QISB160 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-EMC)005032011 -2 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total17 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The test report is invalid if not marked with "exclusive stamp for the test report". 4. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 5. The test report is invalid if there is any evidence of erasure and/or falsification. 6. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 7. Normally, the test report is only responsible for the samples that have undergone the test. 8. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-EMC)005032011-2 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total17 Notice 2 Modification Information: Table 1 Modification Information Modification Information 1 2 3 4 5 6 7 FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-EMC)005032011-2 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total17 REPORT ON EMC Test Of Fixed Wireless Terminal M/N: B160 REGULATION FCC CFR47 Part 15: Subpart B; START OF TEST Feb.28, 2011 END OF TEST Mar.12, 2011 Final Judgement: Pass Approved By 2011-03-13 Liuchunlin Date Name Signature Reviewed By 2011-03-13 Dailinjun Date Name Signature Operator 2011-03-13 heyong Date Name Signature FCC Test Report of B160 FCC ID: QISB160 Report No: SYBH(Z-EMC)005032011-2 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total17 REPORT BODY CONTENT 1 Status ............................................................................................................................................... 6 1.1 Product Information ......................................................................................................................... 6 1.2 Applied Standard ................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 24E | 1.85 GHz - 1.91 GHz | 260.00 mW | 5M00F9W | 2.5 ppm |

Solar Inverter
Equipment Class
DTS - Digital Transmission System
Watch Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit
Equipment Class
CBD - Citizens Band Category A and B Devices
Indoor Router
Equipment Class
DTS - Digital Transmission System
Solar Smart Monitor & Data Logger
Equipment Class
DTS - Digital Transmission System