Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
C3308 CDMA 1X Mobile Phone Copyright © 2007 Huawei Technologies Co., Ltd. and other Huawei trademarks are the trademarks or registered trademarks of Huawei Technologies Co., Ltd. in the People’s Republic of China and certain other countries. All other trademarks mentioned in this manual are the property of their respective holders. The information in this manual is subject to change without notice. Every effort has been made in the preparation of this manual to ensure accuracy of the contents, but all statements, information, and recommendations in this manual do not constitute the warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base, Bantian, Longgang, Shenzhen 518129, People's Republic of China Tel: +86-755-28780808 Global Hotline: +86-755-28560808 E-mail: [email protected] Website: www.huawei.com 1 Your Phone Screen Earpiece Navigation Keys Left Soft Key Talk/Send Key Right Soft Key End / Power Key # Key * Key Number Keys Charger Interface / Data Cable Connector Confirm Key Microphone /Headset jack Clear Key 2 Keys and Functions Press... To... z View All calls in the standby mode. z Make a call or answer an incoming call. z Power on or off the phone (by pressing and holding it). z End a call. z Return to the standby mode. OK z Display the Menu interface in the standby mode. z Select an item. z Perform the function shown on the lower right corner of the screen. z Display Menu in the standby mode. z Select the highlighted item. z Perform the function shown on the lower right corner of the screen. z View the Contacts in the standby mode. z Return to the previous menu. z In the standby mode, access Profiles ( ); Brew ( ); Alarms ( ); Messages ( ) or Create Message ( ) (by pressing and holding it). z During a call, increase volume ( ) ; or decrease the volume ( ) . 3 Press... To... - z Enter numbers and letters. z Access Voice mail in the standby mode (by pressing and holding the 1 key). z Speed-dial a phone number in the standby mode (by pressing and holding the 2-9 keys). z Select a submenu item labeled with the corresponding number. z Enter the * , +, P, T symbols. z Activate or deactivate the Meeting profile (by pressing and holding it). z Provide different functions according to the phone features being used. z Enter the # symbol. z Provide different functions according to the phone features being used. In the editing mode, z Delete a letter on the left of the cursor. z Clear all the letters at a time (by press and hold it). Screen Icons Icon Meaning Icon Meaning Network signal strength The My Profile is activated No network signal Message received 4 Icon Meaning Icon Meaning CDMA 1X 2000 network is activated Memory for messages full(Icon blinks) Domestic roaming A new voice mail is received Overseas roaming A new emergent message is received Calling... Alarm clock on Voice privacy function is activated Battery power level The General profile is activated Open Hands-free The Silence profile is activated The Meeting profile is activated The Outdoor profile is activated - - 5 Menu Tree Radio 1 Creat Message2 Inbox3 Outbox4Drafts5Voice Mail6 Templates7 Recipient List 8 My Folder9 Settings0 Delete All Brew 1 Display Settings2 Date & Time3 Call Settings4 Phone Settings5 Security Settings6 Restore FactorySettings 1 Search2 Search By Location 3 Add New4 Groups5 Speed Dail6 My Number7 Management 1 Recorder2Alarms3 Schedules4Calculator5 Stopwatch6 World Clock7 Gallery8X Kid9 Gulper Settings 1 All Calls2 Missed Calls3 Received Calls4 Dialled Calls5Call Memo6 Call Duration Call Log Messages Tools Contacts (Options when no channel saved)1 Automatic Turning2 Manul Turning3 Fine Turning4 Set Frequency (Options when some channels saved) 1Switch Off 4Turning 2 Speaker On 5 Delete Channel 3 Start Record 6 Rename Channel 1 General 2 Silence 3Meeting4 Outdoor5My Profile 1 6My Profile 2 Profiles Consult your service Provider for more Information about This function. 6 Installing the Battery 1. 2. 3. a b b a External Screen Your phone has an external screen on the outside of the flip. When you close the phone, the external screen indicates the following: z Time and date z Incoming calls and message received z Alarm clock on z Battery power level z Network signal strength z Current profile Charging the Battery 1. Connect the travel charger to the charger interface at the bottom of your phone. 2. Connect the charger to an AC power socket. During the charging, the icon on the upper right corner of the screen is in an animated status. If the phone is powered off during charging, the icon is displayed on the external screen of the phone. 7 3. Wait until the phone is fully charged. If becomes static, the battery is fully charged. 4. Disconnect the charger from the AC power socket. 5. Disconnect the travel charger from your phone. Using the Function Menu To use the function menus, do as follows: 1. In the standby mode, press ( Menu ). 2. Press , to select the desired function menu. 3. Press ( Select )or OK to display the selected menu. Display the submenu in either of the ways: z Press to select a submenu and then press ( Select ) or OK to display the selected submenu. z Press the number key corresponding to the serial number of a submenu to display the submenu. 4. Press ( Back )to return to the previous menu or quit the function menu. 5. Press to return to the standby mode. Making a Call 1. In the standby mode, enter a phone number. z To make an international call, press twice to enter the international long distance code of "+". Then enter the number to be dialed, in the format of "country code + region code + phone number". 8 z To call a number with an extension, press three times to insert "P" or press four times to insert "T" between the phone number and the extension. 2. Press to dial the number. 3. Press or ( End ) to end the call. Note z In the standby mode, press to view the All Calls. Select a record and press to dial. z Select a contact from the Conta…
Text truncated - open the document above for the full version.
Huawei Technologies Co., Ltd. AddressHuawei Industrial Base,Bantian Longgang,Shenzhen 518129, P.R China Post ZIP518129 Page 1/1 To: EMCC Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com SubjectLetter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISC3308 to be kept confidential: 1. Schematic diagram & PCB layout. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Turn-up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager
Huawei C3308 CDMA Handset SECRET Page1,Total 6 External Photo of Huawei C3308 Huawei C3308 CDMA Handset SECRET Page2,Total 6 Huawei C3308 CDMA Handset SECRET Page3,Total 6 Huawei C3308 CDMA Handset SECRET Page4,Total 6 Huawei C3308 CDMA Handset SECRET Page5,Total 6 Huawei C3308 CDMA Handset SECRET Page6,Total 6
Huawei C3308 CDMA Handset SECRET Page1, Total 1 Label C3308 Label Location_C3308
Huawei C3308 CDMA Handset SECRET Page1,Total 4 Internal Photo of Huawei C3308 Huawei C3308 CDMA Handset SECRET Page2,Total 4 Huawei C3308 CDMA Handset SECRET Page3,Total 4 Huawei C3308 CDMA Handset SECRET Page4,Total 4
No. 2007EEE01606Page 2 of 68 Notes 1. . The test report shall be invalid if there is no “specified stamp for the test report” or the stamp of the test organization on it. 2. Copies of the test report shall be invalid if there is no “specified stamp for the test report” or the stamp of the test organization on it. 3. The test report shall be invalid if there are no signatures of the testing person, reviewing person and approving person on it. 4. The test report shall be invalid if it is altered. 5. Any demurral about the test shall be put forward to the testing organization within 15 days after the receiving of the test report. 6. This test report standalone dose not constitute or imply by its own an approval of the product by any Certification Authorities or Competent Bodies. 7. This report is only valid if complete, and test report shall not be reproduced except in full, without written approval of the laboratory. 8. This report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of Telecommunication Metrology Center of MII and the Accreditation Bodies, if it applies. Address:No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China (Telecommunication Metrology Center of MII) Post code: 100083 Telephone: +86 10 62302041Fax:+86 10 62304793 Web site: http://www.emcite.com E-mail: [email protected] No. 2007EEE01606Page 3 of 68 TABLE OF CONTENT 1 COMPETENCE AND WARRANTIES.................................................................................................... 5 2 GENERAL CONDITIONS ....................................................................................................................... 5 3 DESCRIPTION OF EUT .......................................................................................................................... 5 3.1 A DDRESSING INFORMATION RELATED TO EUT ......................................................................................... 5 3.2 C ONSTITUENTS OF EUT............................................................................................................................. 6 3.3 G ENERAL DESCRIPTION............................................................................................................................. 7 4 OPERATIONAL CONDITIONS DURING TEST ................................................................................. 7 4.1 SCHEMATIC TEST CONFIGURATION............................................................................................................ 7 4.2 SAR M EASUREMENT SET-UP..................................................................................................................... 8 4.3 D ASY4 E-FIELD PROBE SYSTEM................................................................................................................ 9 4.4 E- FIELD PROBE CALIBRATION................................................................................................................. 10 4.5 O THER TEST EQUIPMENT......................................................................................................................... 10 4.5.2 P HANTOM............................................................................................................................................. 10 4.6 E QUIVALENT TISSUES.............................................................................................................................. 11 4.7 S YSTEM SPECIFICATIONS......................................................................................................................... 11 5 CHARACTERISTICS OF THE TEST .................................................................................................. 12 5.1 A PPLICABLE LIMIT REGULATIONS........................................................................................................... 12 5.2 A PPLICABLE MEASUREMENT STANDARDS.............................................................................................. 12 6 LABORATORY ENVIRONMENT........................................................................................................ 13 7 CONDUCTED OUTPUT POWER MEASUREMENT ....................................................................... 13 7.1 S UMMARY................................................................................................................................................ 13 7.2 C ONDUCTED POWER................................................................................................................................ 13 8 TEST RESULTS....................................................................................................................................... 14 8.1 D IELECTRIC PERFORMANCE.................................................................................................................... 14 8.2 S YSTEM VALIDATION............................................................................................................................... 14 8.3 S UMMARY OF MEASUREMENT RESULTS.................................................................................................. 15 8.4 C ONCLUSION........................................................................................................................................... 15 9 MEASUREMENT UNCERTAINTY ..................................................................................................... 16 10 MAIN TEST INSTRUMENTS ............................................................................................................. 17 11 TEST PERIOD ....................................................................................................................................... 17 12 TEST LOCATION ................................................................................................................................. 17 ANNEX A MEASUREMENT PROCESS..............................................................................…
Text truncated - open the document above for the full version.
FCC TEST REPORT OF Huawei CDMA Mobile Station M/N: C3308 Jun. 19, 2007 Reliability Laboratory of Huawei Technologies Co., Ltd. All Right Reserved Report No: SYBH(E)22062007 FCC ID: QISC3308 Report No: SYBH(E)22062007 Confidential Information of Huawei. No Distribution without Permission Page2, Total39 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Committee for Laboratories (CNAL), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is C1758, R1672, and T153. 5. The test report is invalid if not marked with "exclusive stamp for the test report". 6. Any copy of the test report is invalid if not re-marked with the "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. Report No: SYBH(E)22062007 Confidential Information of Huawei. No Distribution without Permission Page3, Total39 REPORT ON FCC Test of Huawei CDMA Mobile Station M/N: C3308 Report No: SYBH(E)22062007 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22: Subpart H; FCC CFR47 Part 15: Subpart B; CONCLUSION There are 9 items need to be tested, 9 items have been tested. The sample of the model completely meets the requirements Final Judgement: Pass General Manager 2007.06.10 Guo Xiaoqi Date Name signature Technical Responsibility For Area of Testing 2007.06.09 Zhang Xinghai Date Name signature Test Lab Engineer 2007.06.08 HuJun Huawei Technologies Co Ltd Huawei Industrial Base, Bantian Longgang Shenzhen 518128, P.R China Tel: +86 755 89651014 Fax: +86 755 89652518 Report No: SYBH(E)22062007 Confidential Information of Huawei. No Distribution without Permission Page4, Total39 Contents 1 Summary.................................................................................................................................................... 5 2 Product Description................................................................................................................................ 6 2.1 PRODUCTION INFORMATION................................................................................................................... 6 2.2 MODIFICATION INFORMATION................................................................................................................. 6 3 Test Site Description................................................................................................................................. 7 3.1 TESTING PERIOD................................................................................................................................... 7 3.2 GENERAL SET UP DESCRIPTION............................................................................................................. 7 4 Product Description.................................................................................................................................. 8 4.1 TECHNICAL CHARACTERISTICS............................................................................................................... 8 4.2 EUT IDENTIFICATION LIST.................................................................................................................... 10 5 Main Test Instruments............................................................................................................................ 11 6 Transmitter Measurements.................................................................................................................... 12 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP) ........................................................................ 12 6.2 CONDUCTED OUTPUT POWER............................................................................................................... 15 6.3 MODULATION CHARACTERISTICS.......................................................................................................... 17 6.4 OCCUPIED BANDWIDTH........................................................................................................................ 19 6.5 BAND EDGES COMPLIANCE.................................................................................................................. 21 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL........................................................................................ 23 6.7 RADIATED SPURIOUS RADIATION.......................................................................................................... 25 6.8 FREQUENCY STABILITY........................................................................................................................ 29 7 EMC Test................................................................................................................................................. 33 7.1 CONDUCTED EMISSION AT POWER PORT.............................................................................................. 33 7.2 RADIATED EMISSION OF ENCLOSURE IN IDLE MODE........................................…
Text truncated - open the document above for the full version.
FCC ID: QISC3308 Report No: SYBH (E) 22062007 Confidential Information of Huawei. No Distribution without Permission Page1, Total4 Appendix H Photos of Test Setup FCC ID: QISC3308 Report No: SYBH (E) 22062007 Confidential Information of Huawei. No Distribution without Permission Page2, Total4 1 Radiated Emissions Radiated Disturbance 2 Radiated Spurious Emissions FCC ID: QISC3308 Report No: SYBH (E) 22062007 Confidential Information of Huawei. No Distribution without Permission Page3, Total4 Radiated Spurious Emission (below 2GHz) FCC ID: QISC3308 Report No: SYBH (E) 22062007 Confidential Information of Huawei. No Distribution without Permission Page4, Total4 Radiated Spurious Emission (above 2GHz) 3 Conducted Emissions Conducted Emissions for AC Ports
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22H | 824.7 MHz - 848.31 MHz | 187.00 mW | 1M25F9W | 300.0000000000 Hz |

Solar Inverter
Equipment Class
DTS - Digital Transmission System
Watch Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit
Equipment Class
CBD - Citizens Band Category A and B Devices
Indoor Router
Equipment Class
DTS - Digital Transmission System
Solar Smart Monitor & Data Logger
Equipment Class
DTS - Digital Transmission System