Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Dec 29, 2008
Application Purpose
Original Equipment
Date of Application
Nov 13, 2008
Equipment Note
Cellular/PCS/AWS GSM/GPRS/EDGE/WCDMA USB Modem
Frequency Range
1851.25000000 - 1908.75000000
Company
Huawei Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

Attestation Statements

Cover Letter(s)

External Photos

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

UMG181 SECRET Page1, Total1 ID Label Location_UMG181

Internal Photos

UMG181 SECRET Page1,Total 12 Internal Photos of UMG181 UMG181 SECRET Page2,Total 12 UMG181 SECRET Page3,Total 12 UMG181 SECRET Page4,Total 12 UMG181 SECRET Page5,Total 12 UMG181 SECRET Page6,Total 12 UMG181 SECRET Page7,Total 12 UMG181 SECRET Page8,Total 12 UMG181 SECRET Page9,Total 12 UMG181 SECRET Page10,Total UMG181 SECRET Page11,Total UMG181 SECRET Page12,Total

RF Exposure Info

Caution: See manual for RF Exposure compliance requirements

RF Exposure Info

© 2008 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 2867 Progress Place, Suite 4D • Escondido, CA 92029 • U.S.A. TEL (760) 737-3131 • FAX (760) 737-9131 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Huawei Corp. Dates of Test: Sept. 17-23, Oct. 30, Nov. 21, 2008 1700 Alma Drive, Suite 100 Test Report Number: SAR.20080907 Plano, TX 75075 Revision F This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1999 and had been tested in accordance with the measurement procedures specified in IEEE Std 1528-2003, OET Bulletin 65 Supp. C, RSS-102 and Safety Code 6 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Certificate # 2387.01 FCC ID: QISE181 Model(s): UMG181 Test Sample: Production Unit Serial No.: GA2AA1089300027 Equipment Type: Wireless Modem Classification: Portable Transmitter Next to Body TX Frequency Range: 824.2 – 848.8 MHz, 826.4 – 846.6 MHz, 1712.4 – 1752.6 MHz, 1850.2 – 1909.8 MHz, 1852.4 – 1907.6 MHz Frequency Tolerance: ± 25 ppm Maximum RF Output: 835 MHz (GSM) – 32.86 dBm, 835 MHz (GPRS) – 30.78 dBm, 835 MHz (EDGE) – 27.13 dBm, 835 MHz (WCDMA) – 22.31 dBm, 1700 MHz (WCDMA) – 22.02 dBm, 1900 MHz (WCDMA) – 21.52 dBm, 1900 MHz (GSM) – 29.96 dBm, 1900 MHz (GPRS) – 27.63 dBm, 1900 MHz (EDGE) – 24.65 dBm Conducted Signal Modulation: GSM, WCDMA Antenna Type (Length): Internal Application Type: Certification FCC Rule Parts: Part 22, 24, 27 FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 2 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction...........................................................................................................................................3 SAR Definition [5] .....................................................................................................................................4 2. SAR Measurement Setup.....................................................................................................................5 Robotic System.........................................................................................................................................5 System Hardware .....................................................................................................................................5 System Description ...................................................................................................................................5 E-Field Probe ............................................................................................................................................6 3. Robot Specifications.............................................................................................................................8 4. Probe and Dipole Calibration ...............................................................................................................9 5. Phantom & Simulating Tissue Specifications..................................................................................... 10 SAM Phantom.........................................................................................................................................10 Brain & Muscle Simulating Mixture Characterization.............................................................................. 10 Device Holder .........................................................................................................................................10 6. Definition of Reference Points............................................................................................................11 Ear Reference Point ...............................................................................................................................11 Device Reference Points ........................................................................................................................11 7. Test Configuration Positions ..............................................................................................................12 Positioning for Cheek/Touch [5]..............................................................................................................12 Positioning for Ear / 15 ̊ Tilt [5] ...............................................................................................................13 Body Worn Configurations......................................................................................................................14 8. ANSI/IEEE C95.1 – 1999 RF Exposure Limits [2] .............................................................................15 Uncontrolled Environment ......................................................................................................................15 Controlled Environment ..........................................................................................................................15 9. Measurement Uncertainty ..................................................................................................................16 10. System Validation ..........................................................................................................................17 Tissue Verification .....................…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 262 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Appendix C – SAR Test Setup Photos System Body Configuration Body Tissue Depth FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 263 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Top With USB Cable Bottom Installed In HP Laptop FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 264 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Vertical - Right Side With USB Cable Vertical - Left Side Installed In IBM Laptop FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 265 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Front of Device Back of Device FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 266 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Internal Photo Of Antenna FCC ID: QISE181 © 2008 RF Exposure Lab, LLC Page 267 of 339 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Appendix D – Probe Calibration Data Sheets NCL CALIBRATION LABORATORIES Calibration File No.: CP-840 Client.: RFEL C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized procedures and using transfer standards traceable to NRC/NIST. Equipment: Miniature Isotropic RF Probe 835 MHz BODY Calibration Manufacturer: APREL Laboratories Model No.: E-020 Serial No.: 217 Calibration Procedure: SSI/DRB-TP-D01-032-E020-V2 Project No: RFEB-ALS-E-020-5318 Calibrated: 3 rd December 2007 Released on: 3 rd December 2007 NCL CALIBRATION LABORATORIES 51 SPECTRUM WAY Division of APREL Lab. NEPEAN, ONTARIO TEL: (613) 820-4988 CANADA K2R 1E6 FAX: (613) 820-4161 NCL Calibration Laboratories Division of APREL Laboratories. Page 2 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Introduction This Calibration Report reproduces the results of the calibration performed in line with the SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure. The results contained within this report are for APREL E-Field Probe E-020 217. References SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure IEEE 1528 “Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body Due to Wireless Communications Devices: Experimental Techniques” SSI-TP-011 Tissue Calibration Procedure IEC 62209 “Human exposure to radio frequency fields from hand-held and body- mounted wireless communication devices – Human models, instrumentation, and procedures –Part 1 & 2: Procedure to determine the Specific Absorption Rate (SAR) for hand-held devices used in close proximity of the ear (frequency range of 300 MHz to 3 GHz)” IEEE 1309 Draft Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9kHz to 40GHz Conditions Probe 217 was a re-calibration. Ambient Temperature of the Laboratory: 22 °C +/- 0.5°C Temperature of the Tissue: 21 °C +/- 0.5°C NCL Calibration Laboratories Division of APREL Laboratories. Page 3 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Calibration Results Summary Probe Type: E-Field Probe E-020 Serial Number: 217 Frequency: 835 MHz Sensor Offset: 1.56 mm Sensor Length: 2.5 mm Tip Enclosure: Ertalyte* Tip Diameter: <5 mm Tip Length: 60 mm Total Length: 290 mm *Resistive to recommended tissue recipes per IEEE-1528 Sensitivity in Air Channel X: 1.2 μV/(V/m) 2 Channel Y: 1.2 μV/(V/m) 2 Channel Z: 1.2 μV/(V/m) 2 Diode Compression Point: 95 mV NCL Calibration Laboratories Division of APREL Laboratories. Page 4 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Sensitivity in Body Tissue Measured Frequency: 835 MHz Epsilon: 55.2 (+/-5%) Sigma: 1.05 S/m (+/-10%) ConvF Channel X: 6.1 Channel Y: 6.1 Channel Z: 6.1 Tissue sensitivity values were calculated using the load impedance of the APREL Laboratories Daq-Paq. Boundary Effect: Uncertainty resulting from the boundary effect is less than 2% for the distance between the tip of the probe and the tissue boundary, when less than 2.44mm. Spatial Resolution: The measured probe tip diameter is 5 mm (+/- 0.01 mm) and therefore meets the requirements of SSI/DRB-TP-D01-032 for spatial resolution. NCL Calibration Laboratories Division of APREL Laboratories. Page 5 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Receiving Pattern 835 MHz (Air) Receiving Pattern Probe s/n 217 835MHz 0 0.2 0.4 0.6 0.8 1 1.2 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 Ch1Ch2Ch3Tot NCL Calibration Laboratories Division of APREL Laboratories. Page 6 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Isotropy Error 835 MHz (Air) Isotropy Error Probe s/n 217 835MHz -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 0100200300 Error [dB] Isotropy Plot Probe s/n 217 835MHz 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0100200300 Degrees (x10) Voltage (mV) Ch1Ch2Ch3 Isotropicity Tissue: 0.10 dB NCL Calibration Laboratories Division of APREL Laboratories. Page 7 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Dynamic Range Probe 217 Dynamic Range 0.01 0.1 1 10 100 1000 10000 1.0010.00100.001,000.0010,000.00100,000.001,000,000.0010,000,000.00 Electric Field [(V/m)^2] Voltage [microV] Uncompensated Compensated NCL Calibration Laboratories Division of APREL Laboratories. Page 8 of 10 This page has been reviewed for content and attested t…

Text truncated - open the document above for the full version.

Test Report

Report No: SYBH(R)035082008EB-1 Confidential Information of Huawei. No Distribution without Written Permission Page1, Total38 EMC Test Report Product Name: HUAWEI HSPA Rotate USB Stick Model Number: UMG181 Report No: SYBH(R)035082008EB-1 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 Report on EMC Test of HSPA Rotate USB Stick Report No: SYBH(R)035082008EB-1 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total38 Notice 1 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 5. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is R2364, C2583, and T256. 6. The test report is invalid if not marked with "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. Report on EMC Test of HSPA Rotate USB Stick Report No: SYBH(R)035082008EB-1 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total38 Notice 2 Modification Information: Table 1 Modification Information 1 2 3 4 5 6 Modification Information 7 Report on EMC Test of HSPA Rotate USB Stick Report No: SYBH(R)035082008EB-1 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total38 REPORT ON HUAWEI HSPA Rotate USB Stick M/N: UMG181 REGULATION FCC CFR47 Part 15: Subpart B; FCC CFR47 Part 22: Subpart H; FCC CFR47 Part 24: Subpart E; START OF TEST Aug.05, 2008 END OF TEST Aug.20, 2008 Final Judgement: Pass Approver 2008-09-15 张兴海 Date Name Signature Reviewer 2008-09-15 余 辉 Date Name Signature Operator 2008-09-15 张 飞 Date Name Signature Report on EMC Test of HSPA Rotate USB Stick Report No: SYBH(R)035082008EB-1 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total38 REPORT BODY CONTENT 1 Status ............................................................................................................................................6 1.1 Product Information.......................................................................................................................6 1.2 Applied Standard ..........................................................................................................................6 1.3 Test Site ........................................................................................................................................7 1.4 Test environment condition...........................................................................................................7 2 Summary of Results......................................................................................................................8 3 Equipment Specification ...............................................................................................................9 3.1 General Description ......................................................................................................................9 3.2 Sub-Assembly Identity ..................................................................................................................9 4 System Configuration during EMC Test .....................................................................................10 4.1 Cables Used during Test ............................................................................................................10 4.2 Associated Equipment Used during Test ...................................................................................10 4.3 Test Configurations and Test Mode............................................................................................10 4.4 Test conditions and test Connections.........................................................................................11 5 Electromagnetic Interference (EMI) ............................................................................................13 5.1 Radiated Disturbance 30MHz to 1000MHz................................................................................13 5.2 Conducted Disturbance 0.15 MHz to 30MHz.............................................................................14 5.3 Radiated Spurious Emissions.....................................................................................................15 6 Main Test Instruments ................................................................................................................17 7 System Measurement Uncertainty..............................................................................................18 8 Graph and Data of Emission Test...............................................................................................19 8.1 R…

Text truncated - open the document above for the full version.

Test Report

FCC Test Report Product Name: HSPA Rotate USB Stick Model Number: UMG181 Report No: SYBH(R) 006092008EB-3 FCC ID: QISE181 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total38 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 5. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is R2364, C2583, and T256. 6. The test report is invalid if not marked with "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total38 Huawei Technologies Co Ltd Huawei Industrial Base, Bantian Longgang Shenzhen 518128, P.R China Tel: +86 755 89651014 Fax: +86 755 89652518 REPORT ON FCC Test of HSPA Rotate USB Stick M/N: UMG181 Report No: SYBH(R) 006092008EB-3 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 24: Subpart E; CONCLUSION Pass General Manager Oct. 10, 2008 Date Name signature Technical Responsibility For Area of Testing Oct. 10, 2008 Date Name signature Test Lab Engineer Oct. 10, 2008 Date Name signature FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total38 Contents 1 Summary.................................................................................................................................................... 5 2 Product Description................................................................................................................................6 2.1 PRODUCTION INFORMATION................................................................................................................... 6 2.2 MODIFICATION INFORMATION.................................................................................................................. 6 3 Test Site Description................................................................................................................................. 7 3.1 TESTING PERIOD................................................................................................................................... 7 3.2 GENERAL SET UP DESCRIPTION............................................................................................................. 7 4 Product Description.................................................................................................................................. 8 4.1 TECHNICAL CHARACTERISTICS............................................................................................................... 8 4.2 EUT IDENTIFICATION LIST.................................................................................................................... 10 5 Main Test Instruments............................................................................................................................. 11 6 Transmitter Measurements..................................................................................................................... 12 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (EIRP)........................................................................ 12 6.2 CONDUCTED POWER OF TRANSMITTER................................................................................................. 17 6.3 MODULATION CHARACTERISTICS.......................................................................................................... 20 6.4 OCCUPIED BANDWIDTH........................................................................................................................ 22 6.5 BAND EDGES COMPLIANCE.................................................................................................................. 25 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL........................................................................................ 28 6.7 FREQUENCY STABILITY........................................................................................................................ 31 7 System Measurement Uncertainty......................................................................................................... 37 8 Appendices.............................................................................................................................................. 38 FCC Test Repor…

Text truncated - open the document above for the full version.

Test Report

FCC Test Report Product Name: HSPA Rotate USB Stick Model Number: UMG181 Report No: SYBH(R) 006092008EB-2 FCC ID: QISE181 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total38 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 5. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is R2364, C2583, and T256. 6. The test report is invalid if not marked with "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total38 Huawei Technologies Co Ltd Huawei Industrial Base, Bantian Longgang Shenzhen 518128, P.R China Tel: +86 755 89651014 Fax: +86 755 89652518 REPORT ON FCC Test of HSPA Rotate USB Stick M/N: UMG181 Report No: SYBH(R) 006092008EB-2 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22: Subpart H; CONCLUSION Pass General Manager Oct. 10, 2008 Date Name signature Technical Responsibility For Area of Testing Oct. 10, 2008 Date Name signature Test Lab Engineer Oct. 10, 2008 Date Name signature FCC Test Report of UMG181 FCC ID: QISE181 Security Level: Public Report No: SYBH(R) 006092008EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total38 Contents 1 Summary.................................................................................................................................................... 5 2 Product Description.................................................................................................................................. 6 2.1 PRODUCTION INFORMATION................................................................................................................... 6 2.2 MODIFICATION INFORMATION.................................................................................................................. 6 3 Test Site Description................................................................................................................................. 7 3.1 TESTING PERIOD................................................................................................................................... 7 3.2 GENERAL SET UP DESCRIPTION............................................................................................................. 7 4 Product Description.................................................................................................................................. 8 4.1 TECHNICAL CHARACTERISTICS............................................................................................................... 8 4.2 EUT IDENTIFICATION LIST.................................................................................................................... 10 5 Main Test Instruments............................................................................................................................. 11 6 Transmitter Measurements..................................................................................................................... 12 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP)......................................................................... 12 6.2 CONDUCTED POWER OF TRANSMITTER................................................................................................. 17 6.3 MODULATION CHARACTERISTICS.......................................................................................................... 20 6.4 OCCUPIED BANDWIDTH........................................................................................................................ 22 6.5 BAND EDGES COMPLIANCE.................................................................................................................. 25 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL.......................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Xinghai
[email protected]+86-755-2897-0299Fax: +86-755-8965-0226

Technical Contact

RF Exposure Lab, LLCJay Moulton
[email protected]760-737-3131

2867 Progress Place, Suite 4D · Escondido, California · United States

Non-Technical Contact

RF Exposure Lab, LLCJay Moulton
[email protected]760-737-3131

Test Firm

Huawei Technologies Co., LTDZhou Fengyum
[email protected]86-755-28782917Fax: 86-755-89650226

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
724E1.85 GHz - 1.91 GHz160.00 mW4M20F9W2.5 ppm
Confidentiality
Long Term

Other Applications from Huawei Technologies Co.,Ltd

Solar Inverter - FCC ID QISSUN2000 - Huawei Technologies Co.,Ltd
QISSUN2000

Solar Inverter

Jun 27, 2021

Equipment Class

DTS - Digital Transmission System
Watch Wireless Charger - FCC ID QISCP81-1 - Huawei Technologies Co.,Ltd
QISCP81-1

Watch Wireless Charger

Oct 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit - FCC ID QISRRU3278 - Huawei Technologies Co.,Ltd
QISRRU3278

Remote Radio Unit

Sep 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Indoor Router - FCC ID QISR2561 - Huawei Technologies Co.,Ltd
QISR2561

Indoor Router

Jul 11, 2020

Equipment Class

DTS - Digital Transmission System
Solar Smart Monitor & Data Logger - FCC ID QISSMARTLOGGER310 - Huawei Technologies Co.,Ltd
QISSMARTLOGGER310

Solar Smart Monitor & Data Logger

Mar 23, 2020

Equipment Class

DTS - Digital Transmission System