FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Huawei Technologies Co.,Ltd/
  3. QISEC321

QISEC321CDMA Data Card

Huawei Technologies Co.,Ltd

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Jan 24, 2006
Application Purpose
Original Equipment
Date of Application
Jan 24, 2006
Equipment Note
CDMA Data Card
Frequency Range
824.70000000 - 848.31000000
Company
Huawei Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wonderful Communication, Mobile Life Welcome to use EC301/321/351 Data Card from Huawei HUAWEI EC301/321/351 Data Card User Manual Copyright © 2005 Huawei Technologies Co., Ltd. All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and HUAWEI are trademarks of Huawei Technologies Co., Ltd. All other trademarks mentioned in this manual are the property of their respective holders. Notice The information in this manual is subject to change without notice. Every effort has been made in the preparation of this manual to ensure accuracy of the contents, but all statements, information, and recommendations in this manual do not constitute the warranty of any kind, expressed or implied. Safety Precautions Before using the wireless data card, please read the safety precautions carefully and also let your children know these, so that you can use your wireless data card correctly and safely. For details, see the section “Warnings and Precautions”. Do not switch on your wireless data card when it is prohibited to use wireless device or when the wireless data card may cause interference or danger. Do not use your wireless data card while driving. Follow any rules or regulations in hospitals and health care facilities. Switch off your wireless data card near medical apparatus. Switch off your wireless data card in aircraft. The wireless data card may cause interference to control signals of the aircraft. Switch off your wireless data card near high-precision electronic devices. The wireless data card may affect the performance of these devices. Do not attempt to disassemble your wireless data card or its accessories. Only the qualified personnel is allowed to service or repair the wireless data card. Do not place your wireless data card and its accessories in containers with strong electromagnetic field. Do not place magnetic storage media near your wireless data card. Radiation from the wireless data card may erase the information stored on them. Do not put your wireless data card in a high-temperature place or use it in a place with flammable gas such as a gas station. Keep your wireless data card and its accessories away from children. Do not allow children to use your wireless data card without guidance. 2 Observe any laws or regulations on the use of wireless data cards. Respect others’ privacy and legal rights when using your wireless data card. HUA WEI i Contents 1 Overview ............................................................................................................1 2 What is in Your Packing Box? ............................................................................3 3 Getting to Know Your EC301/321/351...............................................................5 4 Getting Started....................................................................................................9 Computer Configuration Requirements........................................................9 Preparing the EC301/321/351......................................................................9 5 Installation Guide .............................................................................................11 Installing the EC301/321/351 Manager......................................................11 Installing the EC301/321/351 Hardware Driver.........................................12 Removing the EC301/321/351 ...................................................................12 Uninstalling the EC301/321/351 Manager .................................................13 6 The EC301/321/351 Manager GUI Description ...............................................15 Accessing the EC301/321/351 Manager GUI ............................................15 Introduction to the Main Screen .................................................................16 7 Menu ................................................................................................................19 8 Internet Service ................................................................................................21 Network Connection Settings.....................................................................21 Accessing the Internet ................................................................................22 Volume Statistic..........................................................................................23 9 Call Service ......................................................................................................25 Making Calls ..............................................................................................25 C C o o n n t t e e n n t t s s HUA WEI ii Answering Calls .........................................................................................27 Supplementary Services .............................................................................28 Volume Adjustment and Mute ....................................................................28 Shortcut Keys for Call Service ...................................................................29 10 SMS................................................................................................................31 Sending and Receiving Messages ..............................................................31 Message Storage Management ...................................................................40 SMS Settings..............................................................................................41 11 Managing Your Contacts ................................................................................43 Managing the Items in the Contacts ...........................................................43 Importing/Exporting Contacts ....................................................................46 12 Call Logs ........................................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518128, P.R China Post ZIP:518129 Page :1/1 To: EMCC Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89641014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Section 0.457(d) (2) (i) pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISEC321 to be kept confidential: 1. Schematic diagram & PCB layout. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Tune-up procedure. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager

Cover Letter(s)

Klaus Knoerig Von: "Generic Office of Engineering Technology" <[email protected]> An: <[email protected]> Gesendet: Samstag, 14. Januar 2006 00:26 Betreff: Response to Inquiry to FCC (Tracking Number 244611) Seite 1 von 1 2006-01-24 Inquiry: Dear Sir/Madam We are a TCB and we have received an application for Certification of a CDMA 2000 PCMCIA data card. The current FCC policy requires a TCB to ask for advice from FCC prior to certifying a CDMA 2000 device. We hereby ask for guidance regarding SAR review procedures. Sincerly EMCC DR. RASEK Klaus Knoerig Response: Thank you for your inquiry - please see attached and below. Investigations by FCC Lab into 3G technologies and SAR measurement systems issues are continuing. Oct05 TCB training notes included the following: - 3G technologies - 1) TCBs must request advice from FCC prior to certifying a device. Preferably a KDB correspondence should be used for this communication. 2) Current advise that we will give for CDMA-2000 and UMTS is: to digest preliminary info documents provided by OET/Lab (CDMA-2000 or WCDMA), then perform reviews of tests to best extent possible. TCBs in their review should apply good engineering judgment and current procedures such as Supplement C to the exten! t applicable. Additional guidance information is under development. Info documents for other technologies have not been developed at present. 3) When unsure how to address a particular point in their review, TCB should again contact OET/Lab for specific advise. 4) Request-for-info correspondence and FCC response should be included as EAS cover-letter exhibit in the filing, to demonstrate that TCB has requested and reviewed info prior to certification. FYI: CDMA-2000 = IS-2000 = 3GPP2 WCDMA = UMTS = 3GPP Do not reply to this message. Please select the Reply to an Inquiry Response link from the OET Inquiry System to add any additional information pertaining to this inquiry.

External Photos

HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 1 Photo documentation of External of product HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 2 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 3 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 4 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 5 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 6 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 7 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 8 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 9 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 10 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 11 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 12 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 13 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 14 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共15页 15

ID Label/Location Info

EC321 Label Location

Internal Photos

HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共3页 1 Photo documentation of interior of product HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共3页 2 HUAWEI EC321 DATA CARD SECRET 2005-10-14 第1页, 共3页 3

RF Exposure Info

Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 2 of 97 Notes 1. . The test report shall be invalid if there is no “specified stamp for the test report” or the stamp of the test organization on it. 2. Copies of the test report shall be invalid if there is no “specified stamp for the test report” or the stamp of the test organization on it. 3. The test report shall be invalid if there are no signatures of the testing person, reviewing person and approving person on it. 4. The test report shall be invalid if it is altered. 5. Any demurral about the test shall be put forward to the testing organization within 15 days after the receiving of the test report. 6. This test report standalone dose not constitute or imply by its own an approval of the product by any Certification Authorities or Competent Bodies. 7. This report is only valid if complete, and test report shall not be reproduced except in full, without written approval of the laboratory. 8. This report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of Telecommunication Metrology Center of MII and the Accreditation Bodies, if it applies. Address: No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China (Telecommunication Metrology Center of MII) Post code: 100083 Telephone: +86 10 62302041 Fax: +86 10 62304793 Web site: http://www.emcite.com E-mail: [email protected] Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 3 of 97 TABLE OF CONTENT 1 COMPETENCE AND WARRANTIES ............................................................................................................ 5 2 GENERAL CONDITIONS................................................................................................................................ 5 3 DESCRIPTION OF EUT................................................................................................................................... 5 3.1 ADDRESSING INFORMATION RELATED TO EUT............................................................................................... 5 3.2 CONSTITUENTS OF EUT ................................................................................................................................. 6 3.3 GENERAL DESCRIPTION.................................................................................................................................. 6 4 OPERATIONAL CONDITIONS DURING TEST .......................................................................................... 6 4.1 SCHEMATIC TEST CONFIGURATION................................................................................................................. 6 4.2 SAR MEASUREMENT SET-UP........................................................................................................................ 10 4.3 DASY4 E-FIELD PROBE SYSTEM................................................................................................................... 11 4.4 E-FIELD PROBE CALIBRATION...................................................................................................................... 11 4.5 OTHER TEST EQUIPMENT............................................................................................................................. 12 4.5.1 DEVICE HOLDER FOR TRANSMITTERS....................................................................................................... 12 4.5.2 PHANTOM.................................................................................................................................................. 12 4.6 EQUIVALENT TISSUES................................................................................................................................... 13 4.7 SYSTEM SPECIFICATIONS.............................................................................................................................. 13 4.7.1 ROBOTIC SYSTEM SPECIFICATIONS........................................................................................................... 13 5 CHARACTERISTICS OF THE TEST .......................................................................................................... 13 5.1 APPLICABLE LIMIT REGULATIONS................................................................................................................ 13 5.2 APPLICABLE MEASUREMENT STANDARDS.................................................................................................... 14 5.3 CHARACTER OF THE TEST............................................................................................................................. 14 6 LABORATORY ENVIRONMENT ................................................................................................................ 14 7 TEST RESULTS ............................................................................................................................................... 14 7.1 DIELECTRIC PERFORMANCE......................................................................................................................... 14 7.2 SYSTEM VALIDATION.................................................................................................................................... 15 7.3 SUMMARY OF MEASUREMENT RESULTS....................................................................................................... 15 7.4 CONCLUSION................................................................................................................................................ 16 8 MEASUREMENT UNCERTAINTY .............................................................................................................. 17 9 MAIN TEST INSTRUMENTS........................................................................................................................ 19 10 TEST PERIOD ...................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 50 of 97 Position 4, Whole Antenna, Middle of Laptop 2 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Position 4, Whole Antenna, Middle/Area Scan (61x61x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.020 mW/g Position 4, Whole Antenna, Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.02 V/m; Power Drift = -0.045 dB Peak SAR (extrapolated) = 0.024 W/kg SAR(1 g) = 0.019 mW/g; SAR(10 g) = 0.014 mW/g Maximum value of SAR (measured) = 0.020 mW/g 0 dB = 0.020mW/g Fig. 29 Laptop 2, Test Position 4, whole Antenna, CH384 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 51 of 97 Fig. 30 Z-Scan at power reference point (Laptop 2, Test Position 4, whole Antenna, CH384) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 52 of 97 Position 5, Whole Antenna, Middle of Laptop 2 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Positon 5, Whole Anenna, Middle/Area Scan (61x71x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.094 mW/g Positon 5, Whole Anenna, Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.88 V/m; Power Drift = -0.165 dB Peak SAR (extrapolated) = 0.119 W/kg SAR(1 g) = 0.086 mW/g; SAR(10 g) = 0.063 mW/g Maximum value of SAR (measured) = 0.092 mW/g 0 dB = 0.092mW/g Fig. 31 Laptop 2, Test Position 5, whole Antenna, CH384 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 53 of 97 Fig. 32 Z-Scan at power reference point (Laptop 2, Test Position 5, whole Antenna, CH384) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 54 of 97 Position 6, Whole Antenna, Middle of Laptop 6 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Positon 6, Whole Antenna, Middle/Area Scan (61x61x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.145 mW/g Positon 6, Whole Antenna, Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.56 V/m; Power Drift = -0.134 dB Peak SAR (extrapolated) = 0.189 W/kg SAR(1 g) = 0.126 mW/g; SAR(10 g) = 0.079 mW/g Maximum value of SAR (measured) = 0.133 mW/g 0 dB = 0.133mW/g Fig. 33 Laptop 2, Test Position 6, whole Antenna, CH384 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 55 of 97 Fig. 34 Z-Scan at power reference point (Laptop 2, Test Position 6, whole Antenna, CH384) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 56 of 97 Position 7, Whole Antenna, High of Laptop 2 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 848.31 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Position 7, Whole Antenna, High/Area Scan (61x61x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.329 mW/g Position 7, Whole Antenna, High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 16.4 V/m; Power Drift = 0.054 dB Peak SAR (extrapolated) = 0.417 W/kg SAR(1 g) = 0.304 mW/g; SAR(10 g) = 0.207 mW/g Maximum value of SAR (measured) = 0.326 mW/g 0 dB = 0.326mW/g Fig. 35 Laptop 2, Test Position 7, whole Antenna, CH777 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 57 of 97 Fig. 36 Z-Scan at power reference point (Laptop 2, Test Position 7, whole Antenna, CH777) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 58 of 97 Position 7, Whole Antenna, Middle of Laptop 2 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Positon 7, Whole Antenna, Middle/Area Scan (61x61x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.478 mW/g Positon 7, Whole Antenna, Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 20.3 V/m; Power Drift = 0.114 dB Peak SAR (extrapolated) = 0.562 W/kg SAR(1 g) = 0.415 mW/g; SAR(10 g) = 0.285 mW/g Maximum value of SAR (measured) = 0.440 mW/g 0 dB = 0.440mW/g Fig. 37 Laptop 2, Test Position 7, whole Antenna, CH384 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 59 of 97 Fig. 38 Z-Scan at power reference point (Laptop 2, Test Position 7, whole Antenna, CH384) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 60 of 97 Position 7, Whole Antenna, Low of Laptop 2 Electronics: DAE3 Sn536 Communication System: CDMA 1X-new Frequency: 824.7 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.45, 6.45, 6.45) Low Antenna Out Position 7/Area Scan (61x61x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.388 mW/g Low Antenna Out Position 7/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 16.5 V/m; Power Drift = 0.200 dB Peak SAR (extrapolated) = 0.494 W/kg SAR(1 g) = 0.362 mW/g; SAR(10 g) = 0.247 mW/g Maximum value of SAR (measured) = 0.388 mW/g 0 dB = 0.388mW/g Fig. 39 Laptop 2, Test Position 7, whole Antenna, CDMA CH1013 Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 61 of 97 Fig. 40 Z-Scan at power reference point (Laptop 2, Test Position 7, whole Antenna, CDMA CH1013) Telecommunication Metrology Center of Ministry of Information Industry No. 2005E00355-1 Page 62 of 97 Position 7, Half Antenna, Middle of Laptop 2 Electronics: DAE3 Sn…

Text truncated - open the document above for the full version.

Test Report

FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page1, Total7 Appendix A Channel Power Measurement According to CFR 47 (FCC) part 2.1046 & 22.913 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page2, Total7 Channel 1013 (RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page3, Total7 Channel 1013 (RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page4, Total7 Channel 283 (RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page5, Total7 Channel 283 (RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page6, Total7 Channel 777 (RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page7, Total7 Channel 777 (RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page1, Total7 Appendix B Modulation Characteristic Measurement According to CFR 47 (FCC) part 2.1047 & 22.901 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page2, Total7 Channel 1013(RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page3, Total7 Channel 1013(RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page4, Total7 Channel 283(RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page5, Total7 Channel 283(RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page6, Total7 Channel 777(RC1/1) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page7, Total7 Channel 777(RC3/3) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page1, Total4 Appendix C Occupied Bandwidth Measurement According to CFR 47 (FCC) part 2.1049 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page2, Total4 Channel 1013 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page3, Total4 Channel 283 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page4, Total4 Channel 777 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page1, Total53 Appendix D Spurious Emission at Antenna Terminal According to CFR 47 (FCC) part 2.1051 & 22.917(e) FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page2, Total53 1 Measurement Results at Block Edges 1.1 Band Subclass 0 1.1.1 RC1 Block A” and A, Left Edge (824.025MHz) Channel 1013 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page3, Total53 Block A” and A, right Edge (835.005MHz) Channel 311 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page4, Total53 Block B, Left Edge (835.005MHz) Channel 356 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page5, Total53 Right Edge (844.995MHz) Channel 644 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page6, Total53 Block A’, Left Edge (844.995MHz) Channel 689 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page7, Total53 Block A’, Right Edge (846.495MHz) Channel 694 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page8, Total53 Block B’, Left Edge (846.495MHz) Channel 739 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page9, Total53 Block B’, Right Edge (848.985MHz) Channel 777 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page10, Total53 1.1.2 RC3 Block A” and A, Left Edge (824.025MHz) Channel 1013 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page11, Total53 Block A” and A, right Edge (835.005MHz) Channel 311 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page12, Total53 Block B, Left Edge (835.005MHz) Channel 356 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page13, Total53 Block B, Right Edge (844.995MHz) Channel 644 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page14, Total53 Block A’, Left Edge (844.995MHz) Channel 689 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page15, Total53 Block A’, Right Edge (846.495MHz) Channel 694 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page16, Total53 Block B’, Left Edge (846.495MHz) Channel 739 FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page17, Total53 Block B’, Right Edg…

Text truncated - open the document above for the full version.

Test Report

Report No: CSBG (R) 82112005 FCC ID: QISEC321 FCC TEST REPORT OF HUAWEI EC321 CDMA DATA CARD M/N: EC321 Nov. 28, 2005 Reliability Laboratory of Huawei Technologies Co., Ltd. All Right Reserved Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page2, Total40 Huawei Technologies Co Ltd Huawei Industrial Base, Bantian Longgang Shenzhen 518128, P.R China Tel: +86 755 89653414 Fax: +86 755 89653384 REPORT ON FCC Test of HUAWEI EC321 CDMA Data Card M/N: EC321 Report No: CSBG (R) 820112005 Nov. 28, 2005 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22: Subpart H; FCC CFR47 Part 15: Subpart B; CONCLUSION There are 7 items need to be tested, 7 items have been tested. The sample of the model completely meets the requirements Final Judgement: Pass General Manager 2004.12.16 Tang Shuanli Date Name signature Technical Responsibility For Area of Testing 2004.12.15 Zhang Xinghai Date Name signature Test Lab Engineer 2004.12.13 Deng Jiang Date Name signature FCC ID: QISEC321 Report No: CSBG (R)82112005 Confidential Information of Huawei. No Distribution without Permission Page3, Total40 CONTENTS 1 Summary.......................................................................................4 2 Product Description......................................................................5 3 Test Site Description.....................................................................6 3.1 Testing Period.................................................................................................................6 3.2 General Set up Description............................................................................................6 4 Product Description......................................................................7 4.1 Technical Characteristics...............................................................................................7 4.2 EUT Identification List....................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Xinghai
[email protected]+86-755-2897-0299Fax: +86-755-8965-0226

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122H824.7 MHz - 848.31 MHz290.00 mW1M25F9W0.5000000000 ppm
Confidentiality
Long Term
Grant Notes
Output is ERP. SAR compliance has been established in the host products with PCMCIA slot configurations side near the rear as tested in this filing, and can be used in host products with substantially similar physical dimensions, construction, and electrical and RF characteristics. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn 0.929 W/kg

Other Applications from Huawei Technologies Co.,Ltd

Solar Inverter - FCC ID QISSUN2000 - Huawei Technologies Co.,Ltd
QISSUN2000

Solar Inverter

Jun 27, 2021

Equipment Class

DTS - Digital Transmission System
Watch Wireless Charger - FCC ID QISCP81-1 - Huawei Technologies Co.,Ltd
QISCP81-1

Watch Wireless Charger

Oct 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit - FCC ID QISRRU3278 - Huawei Technologies Co.,Ltd
QISRRU3278

Remote Radio Unit

Sep 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Indoor Router - FCC ID QISR2561 - Huawei Technologies Co.,Ltd
QISR2561

Indoor Router

Jul 11, 2020

Equipment Class

DTS - Digital Transmission System
Solar Smart Monitor & Data Logger - FCC ID QISSMARTLOGGER310 - Huawei Technologies Co.,Ltd
QISSMARTLOGGER310

Solar Smart Monitor & Data Logger

Mar 23, 2020

Equipment Class

DTS - Digital Transmission System